- A, Wood:
I. All lumber on or below grade shall be ACQ Pressure Treated Southern Yellow Pine 02 Grade (Fb = 1,000 psi min,)
2. All lumber above grade (non -decking) shall be Southern Yellow Pine 02 Grade
3, All framing lumber shall be hem -fir 02 grade or equivalent
4. Wood structural panels shall be !F" Min, thickness, exposure I structural sheathing
5, In all instances where aluminum comes Into contact with pressure treated wood, provide dielectric separation
B. Concrete (See Site Preparation for Existing Concrete)
C. Masonry: N/A
D, Aluminum
I, All structural aluminum conforms to the minimum requirements of 6005 - T5 for alloy and temper:
2. All structural aluminum work conforms to "Part I -A - specificatione for aluminum structures - allowable stress design:
or "Part 1-5 - Specifications for aluminum structures - building load and resistance factor design" of The Aluminum
Association, Inc, Seventh Edition, Effective January 2000
3, In all instances where aluminum comes into contact with steel, or pressure treated lumber provide dielectric separation
E. Glass
I. Glass units consist of two panes of 1/8" thick tempered glass with an argon fill
2. Glass conforms to ASTM E1300
3, All clear Argon roof glass has the following min. properties, Ashrae Winter U Value = .25 Ashrae Winter R Value = 4,0
Solid Wall Panels
1, Aluminum panel skin is Alloy 3105 - H14/H25 and Is 0.024" thick min,
2, Panel Core Foam is Preformed Expanded Polysterene Board (EPS).
F, Sealant ., 1, All sealant conforms to TT - S - 001543 - A, TT - 8 - 002306, ASTM C - 920 Type S, Grade INS, Class 25.
Sealant to be used for structural adhesion 4 to prevent water Intrusion,
G. Gaskets ,. I, All gaskets are co -extruded and are non -migratory,
H. Fasteners
I, All lag bolts shall conform to stainless steel type 300 18 - 8, with standard flat washer
unless manufacturer galvanized bolts specifies for use with ACQ pressure treated wood
2. Hex bolts has be ASTM A325, plated with standard flat washers and nuts
3. All concrete screws shall be ia" x 2 142" min„ Simpson, Hilti, Rawl, Tapcon, Redhead, Dynabolt,
or approved equal
4, All metal ties and associated accessories shall be hot dipped galvanized
5, All lag bolts shall have a minimum embedment of Sx bolt diameter into structural framing (G = .42 min,)
6, Lag bolts and screws into wood framing shall be provided with pilot holes having a diameter
not greater than 10 percent of the thread diameter of the bolt or screw. All lag bolts and
screws shall be Inserted in pilot holes by turning and under no circumstances by driving with a hammer.
1. All expansion anchors shall be designed in accordance with the specific manufacturers requirements
and allowable loads and shall only be applied in conditions acceptable to manufacturer
8. All fasteners connecting aluminum components or pressure treated lumber are stainless steel
type 300 18 - 8 unless manufacturer galvanized bolts specifies for use with ACQ pressure
I JOB SPEL.IFIC NOTES
GENERAL NOTES
I: CONSTRUCTI ION TO FOLLOW THE REQUIREMENTS OF THE FLORIDA
BUILDING COD
E 2014 5TH EDITION 4 WIND CRITERIA PER ASCE 1-10,
2: NO EGRE65 OPENINGS FROM ANY BEDROOM / SLEEPING ROOM
HAS BEEN COMPROMISED BY PROPOSED SUNROOM
3: ELEVATIONS ARE REPRESENTATIVE ONLY
SU�IROOM
CATEGORY "II" REQUIREMENTS
I, PER
(AAMA/NPEA/NSA 2100-02 THIS STRUCTURE MEETS
CATEGORY
"IW" REQUIREMENTS
2: CATEGORY
"II" SUNROOMS PER AAMA/NPEA/NSA 2100-02
SECTION
10 GENERAL REQUIREMENTS FOR SUNROOMS
SUBN
TE 1.1 ELECTRICAL REQUIREMENTS
SUBNOTE
1.1.1 : (EGRESS LIGHTING REQUIRED ONLY)
SUBNOT£
-L7.2 : EXCEPTIONS: CATEGORY II SUNROOMS ARE
EXE
PT FROM REQUIREMENTS FOR RECEPTACLE OUTLETS.
ELECTRICAL NOTES
I: ANY ELECTRICAL
WORK SHALL BE DONE IN ACCORDANCE WITH THE 2011
NATIONAL ELECTRIC
CODE 4 CONFORM WITH THE FBC 4 ALL LOCAL CODES.
2: ALL ELECTRIC
COMPONENTS SHALL BE TIED TO EXISTING
ELECTRIC SERVICE
4 PANEL SPARES
3. PLACEMENT
OF ALL ELECTRIC COMPONENTS BY
LICENSED ELECTRICAL
CONTRACTOR
4, EGRESS LIGHT
REQUIREMENT: (NEW LIGHT 4 SWITCH OR EXISTING LIGHT
OR SOLAR POWEREV
LIGHT MAY BE USED)
5. ENGINEER Off
RECORD NOT RESPONSIBLE FOR ELECTRICAL WORK,
THE EXISTING VERTICAL LOADING/UPLIFT HAS
NOT CHANGED WITHIN THE SCOPE OF THIS PROJECT
THEREFORE ONLY SHEAR LOADING WILL BE ADDED
TO TH EXISTING SLAB/FO
UNDATION. THE ADDITIONAL
ALUMINUM COLUMNS WITH THE CONNECTION TO THE
SLAB A E STRUCTURALLY SOUND FOR THE ADDITIONAL
WIND LOADING FOR THIS PROJECT AND THEREFORE
REQUIRE NO ADDITIONAL FOUNDATION.
treated wood, or otherwise noted on plans
AN�i1-u.
9. All fasteners shall comply with ASTM A153
3
10. All connectors shall comply with ASTM A653 Class G - IS
LUCiQ
ST. LUCIE COUNTY
I. Site Preparation
_
BUILDING DIVISION
1, Foundation systems must be placed on clean, compacted,
=
REVIEWED
termite -treated fill/soil with vapor barrier.
FOR COMPL
REVIEWED BY
2, Existing Foundation, footing and slab IF noted on the
PATE -22-
Floor Plan have been evaluated 4 found acceptable
PLAN9 A�;D PE MIT
for this application,
MUS i BE KEPT ON JOB OR
NO INSPECTION WILL L'.2 M4^E
J. Reference Standards. ASTM E Ile... ASTM E 1300...
ASCE 1-10,.. AAMA/NPEA 2100-02
3,0: Use and occupancy category 2
CONCFAIEDFASTEIiE
4,0: All fenestration products comply
5,0: All wall and roof panels and assemblies comply
ARE THERESPOF
lb.o: Does not apply to category 2
- - L 1
1,0: All applicable provisions raompiy
K, Florida Product Approvals (provided by contractor):
"SEE PRODUCT APPROVAL AFFIDAVIT"
All listed product approvals have been reviewed
and accepted by the engineer of record.
L. DESIGN LOADS:
This structure has been designed in accordance with, 4 meets
the requirements of the Florida Building Code, Residential
2014 5th Edition 4 Amendments 4 ASCE 1-10 per Section
R301,2,1.1, 4 all applicable sections of R301 design criteria.
Design Criteria:
Design Roof Load: Dead Load (Addition): 10 PSF
Live Load (Roof): 20 PSF
Wind Velocity (ULT): 165MPW (3 sec gust) Exposure: C
Risk Category: II Building Height: < 30'
Mean Roof Height: <15'
Enclosure Type: Sunrooms - Enclosed
/
THESE PLANS AND ALL BROPOSFD WORK
ARE SULIIE.CT'PU AN' C",!`1F.TION8
REQUIRED Cf PIG; D INVTU^ r( iu Tf,AT
MAY FEE NECESSARY I-N OROFN Ii)
COMPLY WITH AU APPLICAbLI CCHS,
>ORAiTACHMENTS SLEEPING ROOMS PROVIDE AN EGRESS
WINDOW WITH A NET CLEAR OPENING
I8104FINE OF 5 $0. FT. FOR GROUND FLOOFS.
UPPER PL00'RS. OPENINGU
�� SHALL NOT BE LESS THAN 24'H OR 20AV
SiLL NOT MORE THAN 44" ABOVE FLOOR.
-i:, copy
EXISTING PORCH
ROOF TO REMAIN
�t CUSTOM
I FIXED GLASS
Max Components and Cladding Pressures:
Worst Case Wall Zone 5: +34.1/-40.6 psf EXISTING
2 STORY TYp•
M. Abbreviations RESIDENCE SOLID
The following Itst of abbreviations is not Intended to represent 4 OPENINGS PANEL -►
all those used on these drawings, but to supplement the more TO REMAIN WALL
common abbreviations used: TYP, - Typical SIM. - Similar ill-L
UNO. - Unless Noted Otherwise CONT. - Continuous
V•I,F - Verify In Field
N. Responsibility LEFT ELEVATION
1. All site work shall be performed by a licensed contractor in SCALE: 1/4" I'-O"
accordance with applicable building codes, local ordinances, etc,
2. Contractor shall verify all dimensions and details, notifying engineer
of any discrepancies between drawings, fabricated items, or actual
field conditions
3. These drawings represent the acceptability of the "Sunroom" room
addition elements as provided by the contractor
4. All details on these drawings are engineered based on information
provided by the contractor
5. Refer to the manufacturers shop drawing for further details
to, Any details not shown are to be engineered in
accordance with standard engineering Practices,
O, Miscellaneous
I, This structure conforms with Catagory II Sunroom requirements•
2: Catagory II Sunrooms per AAMA/NPEA/NSA 2100-02
Section 1.0 General Requirements for Sunrooms
Subnote 11 Electrical Requirements
Subnote 1,1,1 (Egress Lighting required only)
Subnote 1.1.2 : Exceptions: Catagory II Sunrooms are
exempt from requirements for receptacle outlets,
?�1
+
014A S.M.S. SCREW w/ 1 f/2" S,S,
NEOPRENE GASKET WASHER
(1) SCREW a MAX 3" FROM EA SIDE 4
a MAX 1" O.C. - TTL OF Cu PER POLY -PANEL
e FRONT EDGE w/ MIN, 1" EMBEV INTO BEAM
e GABLE END SIDES MAX 12" O.C.
EXISTING PANEL ROOF
e SEE WALL SECTION
0 FOR AD01770N4L
DEr,4/LS
EXTR'D ALUMINUM
1.45" x 2.10" x 4" x .25"
L - SHAPED CLIPS
EXTR'D ALUMINUM
3" x 3" x 0.125" COL.
EAVE / BEAM / COL.
NOT TO SCALE
APPLY STRUCTURAL
SEALANT
EXTR'D ALUMINUM
3" x 3" x 0.125" BEAM
"14 x I" TEK SCREW
C3) PER L- SHAPED CLIF
TO BEAM TTL OF (6)
(8) INTO COL. (4) EA
_ SIDE - 2 ROWS OF 2
CONNECTION SECTION
14" (2) ANCHOR CLUSTER - MAX 4" SPACING
e MEETING RAIL FOR NON -IMPACT
MAX O,C, 511 4 (4) ANCHOR CLUSTER FOR IMPACT
MAX 5" MAX
-�� X X 13 1/4"
MAX
5" MAX
ANCHORS SAME AS HEAD REQUIRED SILL
ANCHORS - 012 SMS OR EQUAL INTO 1/8" 6063-T5 ALUM
PROVIDE 5 PITCHES MIN. PAST THREAD PLANE
TYP. WRZ. WINDOW ANCHOR DETAI,
TYP. ANCHOR INFO FOR FIXED GLASS
012 SMS OR EQUAL INTO 1/8" 6063-TB ALUM MIN,
PROVIDE 5 PITCHES MIN. PAST THREAD PI-ANE
1/4" TAPCOINS INTO CONCRETE MIN, 1 1/4" EMBED
6" MAX FROM CORNERS 4 12" MAX O.C.
FRAME HEAD / SILL / JAMBS
TYP. ANCHOR INFO FOR SLIDING GLASS DOOR
"14 SMS OR EQUAL INTO 1/6" 6063-T5 ALUM MIN, STRUCTURE
4 012 SMS OR EQUAL INTO 1/8" ALUM MULLIONS MIN,
PROVIDE 5 PITCHES MIN. PAST THREAD PLANE
I/4 TAPCONS INTO CONCRETE MIN, 1 I/4 EMBED
TYP. ANCHORS IN PAIRS - 6" MAX FROM CORNERS
4 18" MAX O.G. a FRAME HEAD / SILL
- _ 4 13 3/4" MAX r .inM.a
(4) ANCHOR CLUSTER - MAX 6" SPACING e C/L OF STILES
EXISTING PORCH
ROOF TO REMAIN
CUSTOM f I x
>e FIXED GLASS u
x " EXISTING
TYP, 2 STORY
SOLID - RESIDENCE
it '� WALL PANEL
S
_ 4 OPENING
TO REMAIN
TYP:
.- ,SOLID -PANEL.
RIGHT ELEVATION
SCALE: 1/4" = I'-O"
.)
d)
Q
SEE PRODUCT APPROVAL / NOA
FOR TYP. CONNECTIONS FOR OPENING
APPLY STRUCTURAL SEALANT AS
NEEDED FOR WATERPROOFING
GABLE -END WALLS
CONNECT SILL DIRECTLY
TO ROOF PANEL U.N.O.
FRONT WALL SECTIONS
SEE EAVE DETAIL
- 014 x 3/4
TEK SCREW
BEAM
OR STAGGERED
MULLION (TYP.)
- - - -
I
SOLID PANEL li
SILL FILLER l -
\ " AS NEEDED (4) #14 x 1/4"
APPLY BEAD TEK SCREWS
STRUCTURAL
SEALANT TYP (2) EA SIZE a
- BTM OF PANEL
(TYP,)
MULLION
MULLION 014 x 3/4'
TEK SCREW
a 16" O,C
STAGGERED
(TYP.)
'/' FIXES (TYP.)
GLASS
012 S,T,S, IF NOTED
PER N,O,A, SEE PLAN
I n, n I
MULLION I-tn�-t�- f1
4 CLIP I
•14 x 3/4"
TEK SCREW
r !
a 16" O,C,
I �
STAGGERED
(TYP.)
I
�uI
"
(TYP,)
wit
U L.-.Jl.JI
S,T,S,
PER N,O.A,
SLIDER V 11
WINDOW I-FF"--7TE
OR
��
SEE
FLOOR
II
PLAN
F
"
(TYP.)
- ----
PER N,O,A.
wl4 x 3/4"
TEK SCREW
MULLION
a 16" O,C.
- - - -�
STAGGERED
(TYP.)
_
SILL SOLID
PANEL
KICK
APPLY BEAD, I _ _ - _ _
STRUCTURAL _ �- _ _
SEALANT TYP. �` -T(4) 0I4 x 3/4"
TEK SCREWS
SILL (2) EA SIDE a
\ BTM OF PANT
(TYP )
OUTSIDE
EDGE
,
------- - -
SEE SILL CONNECTION DETAIL
WALL SECTION
NOT TO SCALE
\EXISTING 2 STORY REST
\ I �4OPENINGS TO REM �A�
CONTRACTOR TO /ERIFY TYPICAL ALUMINUM COL, SYMBOL KEY
EXACT WINDOW SIZES A 3 x 3 x .125 HOLLOW ALUMINUM
❑$ 2 x 3 x .125 HOLLOW ALUMINUM
ELECTRICAL
SYMBOL
OUTLET
dl
LIGHT
C
SWITCH
EXISTING
CONCRETE SLAB 4 FTG.
TO REMAIN
NON -HABITABLE
UN-AIRCONDITIONED
+/- 5' 8" U +/- 5' 8" U +/- 5' 8" U +/- 5' 8" U +/- 5' 8"
SL W SL W SL W SL W SL W
FLOOR PLAN
SCALE: 1/4" - 1'-0"
1/4" x 2 1/2" FASTENERS
OUTSIDE FACE 011: INTO EXISTING STRUCTURE
EXISTING STRUCTURE /COLS, a 16" O,C, MAX, VERTICALLY
APPLY CAULKING
BETWEEN SILL 4 WALL
TAPCONS FOR CONC.
",'/
LAG -BOLTS w/ WASHER
012 x 3/4" TEK SCREWS : 'R9ALL PANEL2 r:) FOR WOOD FRAME
a RECEIVER CHANNEL :'e; oN�Y ,•,,
TO WALL
a MAX 12" O.C. VERT, A• "
PLAN VIEW .090 RECEIVER CHANNEL
ATTACHMENT TO EXISTING STRUCTURE FOR SOLID PANELS
NOT TO SCALE
INSIDE ROOM
WALL
PANEL
U 3"x3"x0.
z ALUMINU
COL,
(3) 014 x 3/4" TEK SCREWS
EACH SIDE OF COLUMN
SEE SILL
CONNECTION
FOR DETAIL
PLAN VIEW
(3) 014 x 3/4" TEK SCREWS CONT, 1.5" x 3" x .090"
CLIP TO COLUMN EXTR'D ALUMINUM SILL
0 TYP 3" ALUM, COL, CONNECTIONS
NOT TO SCALE
PLAN VIEW
TYP
(3) 014 x 3/4"
TEK SCREWS `
CLIP TO COLUMN
WIN_
,
MULLION CLIP
TYP
(3) 014 x 3/4" TEK/ 3" x 3" x 0.125"
SCREWS SILL TO ALUMINUM
OUT SIDE CORNER COL, ❑
OF COLUMN A
INSIDE ROOM
CONT,
1,5" x 3" x 'OSO"
-EXTR'D ALUMINUM
SILL BELOW
_-
WALL
PANEL
TYP. 3" ALUM. CORNER COL. CONNECTION AT SILL
NOT TO SCALE
INSIDE w •TAPCON SCREWS is 2" MIN
OF = 4 ANCHOR BOLTS e 3" MIN
ROOM z FROM CONCRETE EDGE
I
SILL CONNECTION TO CONCRETE
2" - 3" s
MIN, (1) 3/8" x 2 1/2" TAPCON SCREWS
MIN.
ON EA SIDE OF UPRIGHT a 2" MAX
4 MAX 12" O.C. BETWEEN - OR -
(U 3/8" x 3 3/4" ANCHOR BOLT
ON EA SIDE OF UPRIGHT e 2" MAX
UNIT WIDTH / LENGTH 4 MAX 16" O.C. BETWEEN
SILL TO CONCRETE SLAB CONNECTION DETAIL
NOT TO SCALE
WALLS UNDER SUNROOM SYSTEM
PORCH ENCLOSURE SOLARIUM
PER AAMA/NPEA/NSA 2100-02
THIS STRUCTURE MEETS SUNROOM CATEGORY "II" REQUIREMENTS
PRODUCT APPROVAL SUBMITTAL AFFIDAVIT
THE FOLLOWING PRODUCTS WILL BE THE JENKINS RESIDENCE
INSTALLED IN THE STRUCTURE LOCATED AT: 124 PEPPER LANE
JENSEN BEACH, FL 34951
PROD, DESIGN
PRODUCT
PRODUCT
MANUF,
MODEL *
PRESSURES
APPROVAL
SLDING
GLASS DOOR
+16 -85.0 PSF
LAWSON
9200 IMPACT
FL 15441.4
HRZ, WINDOW
+/- 80 PSF
LAWSON
HS 8100 IMPACT
FL 15428,3
FIXED WINDOW
+/- 18,0 PSF
LAW50N
4200/6200 IMPACT
FL 15429.2
MULLIONS
+/- 54 PSF
LAWSON
I x 3 IMPACT Alum,
NCA 11-0222,13
STRUCTURAL
+ 4'3 -10 PSF
ELITE
3" x 0.032"x 2" EP5 IMPACT
FL 12225,1
WALL /KICKS
Aluminum Composite Panel
1 HAVE REVIEWED THE ABOVE
COMPONENTS AND CLADDING,
AND HAVE APPROVED THEIR
USE IN THE STRUCTURE TO
PROVIDE ADEQUATE RESISTANCE
TO THE WIND LOADS AND FORCES
SPECIFIED BY THE CURRENT CODE
PROVISIONS,
AS SIGNED, SEALED 4 DATED HERE,,. =
DEC 2 9 2017
PErMll-TING
St. Lucie Goimty, FL
Y�
1
a) b
O :4
�
O O a 0,
Q m
wd 00
Z U 00
ZC��:)a
°'3a�
w O 0o04
a
rn
Uj1-L
7
ZZ�
lu
�•1
LU`ZX'
Q
LL
111
1 �-t
LU
0-
'
LU
1-L
Z
Z
�
N
LU
Uj
z
V lil �Q
so a 01
J - 01
QC oMEDt�
Q- 3 U_ U ,i
Qj• to
Z to�m '"s
.,
U13
mom,
N J A
p�p-
1L- Q Q 0
a Copyright 2011
All rights reserved,
REVISION DATE
JOB M 11123
DATE : 12/5/11
SHEET
1 of 1