HomeMy WebLinkAboutPLAN VIEW 1-19-18Sheet 1
A/C DUCT LAYOUTl-
PRODUCT APPROVALS
Product
Opening Deatgn
i?raas_,�treR,_
Product Rated
Devi n Pnca
Manufacturer
MOAN Humber
Produd Approval
Hu erTval
GUM
Method of Atledtmant
C1tf'Wt'w
z;.r "C"
GARAGE DOOR
OPENING INFILL DETAIL
'" .
_ SIDE VIEW
• .zx•� i0/'PeL�1c
5)--6d saE-dd1L5
�- Z, dW > -revs
Certification for Design Load Compliance
DMN oeosu IRS AND ASSUMPTIDNS USED: (complete all that apply)
1. DESIGN CODE: 7--/b
2. Structure Designed as (check one): Enclosed _Partially Enclosed _Open
3. Risk Category: _1 ✓II 111 _ IV Exposure Category: _B _C _D
4. Design Wind Velocity /5�6 mph ✓ASD _LRFD End Zone Width: ft
5. Mean Roof Height /✓t ft Roof Pitch: _ 5— 12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft V 15'MRH, clearht label on all plan openings):
,��� *60.8 #
Zane 1: _Zone 2: —Zone 3: Zone 4: r_ Zone St • y�3 Garage:
7, Design Loads: Floor: !PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? ✓Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? ✓Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: Z SW PSF Soil Test Reports Submitted? _yes
r
,Z00 A-:
f�NEL
F'LUIYIC311V17 1'[I�CR'
AREA CALCULATIONS:
ENCLOSED GARAGE 598 S.F.
EXISTING RESIDENCE 2359 S.F.
TOTAL A/C AREA 2957 S.F.
73t--�a '
ENCLOSED GARAGE
w/ ELECTRICAL
PLAN VIEW
EXISTING RESIDENCE
ELECTRICAL
LOAD
CALC'S.
Existing
Service Feeder Size: 200 AMP Existing Panel Size: 200 AMP
Main Breaker Size: 200 AMP Number
of Breakers: 24
Existine
Loads
2359
Sq. Ft. X 3 watts per sq. ft............................7077
_watts
2
Appliance cir. @ 1500 watts each....................3000
watts
1
Laundry cir. @ 1500 watts each......................1500
watts
1
Range @ 8 kw.................................................8000
watts
1
Dishwasher and disposal @ 1500 watts each ......
3000
watts
1
Microwave @ 2000 watts ............................
2000
watts
1
Water heater @ 4.5 kw ...............................
4500
_watts
0
Tankless water heater..................................0
watts
1
Dryer @ 5 kw ................... :....................
...5000
watts
1
Refrigerator @ 1500 watts .....................1500
watts
3.5
Bathroom 1 @ 1500 watts .........................
5250
watts
1
Sprinkler Pump .....................................
2500
watts
1
POOL PUMP
Other ...........
2500
watts
1
Other POOL LIGHT
2500 ..
watts
1
Other598 SF ADD'N @3 WATTS '
1794
watts Sub total 60,121
10,000
First 10 kw @ 100% .................., ........10,000
watts
40,121
Remainder @ 40%...................................................16,048
watts
10,000
A/C heat @100%....................................................10,000
watts
Total watts 36,048
Divided by
240 volts =150.2
Prepared by: RICHARD JEMISON
Date: 12/10/17
Watts
Amps
.a'
GENERAL NOTES:
1. THE EXISTING GARAGE WAS ENCLOSED OVER (10)
YEARS AGO BY THE PREVIOUS OWNER.
2. THE GARAGE DOOR WAS REMOVED AND THE
OPENING INFILLED WITH 2X4 FRAMING.
3. (1) - (NON -IMPACT) EGRESS WINDOW WAS
INSTALLED WITH STORM SHUTTERS.
4. GARAGE WALLS & CEILING WERE INSULATED.
5. THE ORIGINAL EXISTING HVAC SYSTEM WAS USED
AND DUCTS WERE ADDED. WITH THE ADDITION IT
MEETS THE 2014 FBC (5TH EDITION) ENVIRONMENTAL
CODE.
6. ELECTRICAL WORK WAS DONE AND ADDITIONAL GFI,
AFI OUTLETS ADDED PER 2011 N.E.C.
7. THE LAUNDRY WAS MOVED WITHIN THE GARAGE TO
i A NEW LOCATION.
-,CANNEI ST.LUC'r roL'NTY°tit ^mac tern
3Y REVIEWED FOR C t' l C
31' Lucie Count) TR7ATE ICE BY
-
- -- -- C. F4 `tIT 11UST-BE ICr PT DXJOB
iC, NN E( OR NO INS. ECTION WILL BE 11ADE.
Lucie COUIlt1:
Design by:
RICHARD A. JEMISON THESSPB ECT TOANYCORRECTWORK
IONS
P.O. Box 5616 MAY BE NECESSARY IN ORDER Bytr R O HAT
\11IIFt. Pierce, Fl. 34954 COMPLY WITH ALL APPLICABLE CODES.
`EHUrC111 772) 215-5623
8
BENCHMARK ENGINEERING
E O �/ '
ST OF THE TREASURE COAST
0� 806 DELAWARE AVE.
FT. PIERCE, FL. 34950
NA<<dqr (772) 772-267-1399
REVISED
01/15/18
SEAL
BOWVOIN
GARAGE CONVERSION
SHEET
LATRECE PRESTON
HUTCHINSON
4103 REDWOOD DRIVE
P.E. #70878
FT. PIERCE, FLORIDA
OF 1
Cop