Loading...
HomeMy WebLinkAboutPLAN VIEW/�/r3/(7 Shoot A/C DUCT LAYOUT_ PRODUCT APPROVALS — Product Opening Design Produot Ramd M"ufaetuMr Modal Numbm Produat Approval ikttthor Glass T Method of A0achmard Tied �FF�✓Y1�9 �/'�'oc- �.a-x. YSONnO.� � ,!. 2 i � ��f 6'.f�'2�'t� fc Z . / �SrF �'�/o WD�l� i.••,, � EIYIE� Syva-j s �-�� .tvtS ��'�X f�i/9�o5t z' �',f r✓ . ems` w-o��. li�l II IIII 1� III I) IIiI O II II GARAGE DOOR OPENING INFILL DETAIL II II I I I I a3"W,9I e,z4Ho,c. a 2 .0 4 7-0,P p4A! i 5, 4 siUtas �/lo'o.c. .rx INTERIOR WALL SECTION SIDE VIEW i �_�CANNEI BY Certification for Design load Compliance St Lucie County DESIGN PARAMMejAND ASSUMPTIMS USED: (complete all that apply) 1. DESIGN CODE: Florida 2-r7_ e 4 Code i ff .A3C.,ee 7 -/z^ 2. Structure Designed as (check one): Enclosed —Partially Enclosed —Open 3. Risk Category: —1 ✓11 _III — IV Exposure Category: _B TC —D 4. Design Wind Velocity o mph ✓ASD _,_,_LRFD End Zone Width: it 5. Mean Roof Height /r ft Roof Pitch: —�:12 Parapet: it 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 1S'MRH, clearly label on all plan openings): Zone 1: _ Zone 2: Zone 3: Ny/F Zone 4: -y L Zone 5:^J; Garage: 7. Design Loads: Floor: -PSF Roof/Dead: --PSF Roof/Live: Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? ✓Yes —Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? ✓Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure:Z�� PSF Soil Test Reports Submitted? Yes rLUIV101N%J 1'C10r-M AREA CALCULATIONS: ENCLOSED GARAGE 598 S.F. EXISTING RESIDENCE 2359 S.F. TOTAL A/C AREA 2957 S.F. 3 qP Sor�8 pf) — � N i t cl:L` i r A ENCLOSED GARAGE w/ ELECTRICAL PLAN VIEW EXISTING RESIDENCE ELECTRICAL LOAD CALC'S Existing Service Feeder Size: 200 AMP Existing Panel Size: 200 AMP Main Breaker Size: 200 AMP Number of Breakers: 24 Existine Loads 2359 Sq. Ft. X 3 watts per sq. ft........................... 7077 watts 2 Appliance cir. @1500 watts each ................... 3000 watts 1 Laundry cir. @ 1500 watts each ..................... 1600 watts 1 Range @ 8 kw.................................................8000 watts 1 Dishwasher and disposal @ 1500 watts each ...... 3000 watts '..� 1 Microwave @ 2000 watts ............................ 2000 watts 1 Water heater @ 4.5 kw ............................... 4500 watts 0 Tankless water heater..................................0 watts 1 Dryer @ 5 kw ................... :................ ....... 5000 watts 1 Refrigerator @ 1500 watts .......... I.............1500 watts 3.5 Bathroom 1 @ 1500 watts ......................... 5250 watts 1 Sprinkler Pump ....................................... 2500 watts 1 Other POOL PUMP 2500 watts 1 Other POOL LIGHT 2500 watts 1 Other598 SF ADD'N @3 WATTS 1794 watts Sub total 50,121 Watts 10,000 First 10 kw @ 100%....... - 10,000 watts 40,121 Remainder @ 40%...................... ............................. 16,048 watts 10,000 A/C heat @100%.................................................... 10,000 watts Total watts36,048 Divided by 240 volts =1 50.2 Amps Prepared by: RICHARD JEMISON Date: 12/10/17 GENERAL NOTES: 1. THE EXISTING GARAGE WAS ENCLOSED OVER (10) YEARS AGO BY THE PREVIOUS OWNER. 2. THE GARAGE DOOR WAS REMOVED AND THE OPENING INFILLED WITH 2X4 FRAMING. 3. (1) - (NON -IMPACT) EGRESS WINDOW WAS INSTALLED WITH STORM SHUTTERS. 4. GARAGE WALLS & CEILING WERE INSULATED. 5. THE ORIGINAL EXISTING HVAC SYSTEM WAS USED AND DUCTS WERE ADDED. WITH THE ADDITION IT MEETS THE 2014 FBC (5TH EDITION) ENVIRONMENTAL CODE. 6. ELECTRICAL WORK WAS DONE AND ADDITIONAL GFI, AR OUTLETS ADDED PER 2011 N.E.C. 7. THE LAUNDRY WAS MOVED WITHIN THE GARAGE TO 1 A NEW LOCATION. �Q 8. ALL WORK APPEARS TO BE DONE IN SUBSTANCIAL COMPLIANCE WITH THE 2004 FLORIDA BUILDING CODE IN EFFECT AT THE TIME. ,6CANNEt, BY St Lucie Count\ �\G!11HUII!// ON 7087E * f S F y Design bv: RICHARD A. JEMISON P.O. Box 5616 Ft. Pierce, Fl. 34954 (772)215-5623 BENCHMARK ENGINEERING OF THE TREASURE COAST 806 DELAWARE AVE. FT. PIERCE, FL. 34950 (772)772-267-1399 .5 r 12112//17 SEAL BOWDOIN GARAGE CONVERSION SHEET LATRECE PRESTON HUTCHINSON 4103 REDWOOD DRIVE P.E. #70878 FT. PIERCE, FLORIDA OF 1