EVALUATION REPORT
Tarco Roofing
One Information Way, Suite 225
Little Rock, AR 72202
(254)913-7750
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203) 262-9245
Evaluation Report 10880.07.08-119
FL10450-R9
Date of Issuance: 07/11/2008
Revision 9:10/03/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6ch Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
x"W,trrrrz^,,r—
41
_ y .
41,
Robert J.M. Nieminen, P.E.
`°c r dao;''
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/03/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Tarco Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance
with the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set
forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1507.1.1, T1507.1.1
Physical Properties
ASTM D226
2009
1507.1.1, T1507.1.1
Physical Properties
ASTM D4869
2016
1507.1.1, T1507.1.1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.2.9.2
Physical Properties
ASTM D3909
2012
1507.2.9.2, FRSA/TRI April 2012
Physical Properties
ASTM D6380
2013
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
FRSA/TRI April 2012
Physical Properties
ASTM D6164
2011
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
FRSA/TRI April 2012 (04-12)
T33190.08.10
08/06/2010
ERD (TST6049)
ASTM D1970
T32530.08.10
08/17/2010
ERD (TST6049)
ASTM D1970
T30160.08.09-111
10/12/2010
ERD (TST6049)
FM 4474
T37610.07.11
06/29/2011
ERD (TST6049)
ASTM D3909
T40780.04.12
04/06/2012
ERD (TST6049)
ASTM D6380
T40790.04.12
04/06/2012
ERD (TST6049)
ASTM D6164
T35410.04.12
04/18/2012
ERD (TST6049)
ASTM D1970
T45250.04.13-R2
04/23/2013
ERD (TST6049)
FRSA/TRI April 2012 (04-12)
T43930.09.13-R2
09/11/2013
ERD (TST6049)
ASTM D226 & D4869
SC4950.02.14-R2
06/25/2014
ERD (TST6049)
ASTM D1970'
TAR-SC9480.15
07/02/2015
ERD (TST6049)
FM 4474
TAR-SC8020.14
12/03/2015
ERD (TST6049)
FM 4474
TAR-SC5670.03.16
03/21/2016
ERD (TST6049)
FM 4474
T6460.06.07-R2
05/26/2017
ERD (TST6049)
ASTM D226
TAR-SC13965.02.17-R1
05/17/2017
ERD (TST6049)
FBC 1507.1.1 (Exception)
TAR-SC16115.17
10/02/2017
ERD (TST6049)
FRSA/TRI April 2012 (04-12)
TAR-SC16115.17
10/02/2017
PRI(TST5878)
ASTM D1970
BRY-018-02-01
08/11/2003
PRI(TST5878)
ASTM D1970
BRY-017-02-01
08/11/2003
PRI(TST5878)
ASTM D226
TOT-614-02-02
05/18/2004
PRI(TST5878)
ASTM D226
TOT-015-02-02
05/24/2004
PRI(TST5878)
ASTM D4869
TOT-009-02-01
09/14/2004
PRI(TST5878)
ASTM D4869
TOT-009-02-02
09/14/2004
PRI(TST5878)
ASTM D226
TOT-041-02-01
05/24/2006
Miami -Dade (CER1592)
FBC HVHZ Certification
16-1116.09
01/12/2017
Tarco Roofing
Adhesive compound
Affidavit
12/15/2015
UL, LLC. (QUA9625)
Quality Assurance
Service Confirmation
Exp. 06/28/2020
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9
Certificate of Authorization #9503 eH EDITION (2017) FBC NON-HVHZ EVALUATION FL104S0-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 2 of 10
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
e
Leak S300 Ice and Water Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS
odified roof unde yment; meets ASTM D1970.
LeakBarrier PS200"T I e and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS
odified roof underl ent; meets ASTM D1970 and FRSA/TRI April 2012 (04-12).
LeakBarrier PS200mu Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film
surfaced, SBS modified roof underlayment; meets ASTM D1970.
LeakBarrier NR500"T is a self -adhering, plastic film surfaced, modified underlayment; meets ASTM D1970.
m
LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced
modified underlayment; meets ASTM D1970.
4.2 Mechanically Fastened Underlayments:
Tarco 15 is an asphalt -saturated organic felt; meets ASTM D226, Type I.
Tarco 30 is an asphalt -saturated organic felt; meets ASTM D226, Type II.
Tarco NO 30 is an asphalt -saturated organic felt; meets ASTM D4869, Type Il.
e
LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment; meets physical
requirements of ASTM D226, Types I and ll.
4.3 Mechanically Fastened and/or Bonded Underlayments:
Fiberglass Mineral Surfaced Roll Roofing is a glass -fiber -reinforced, asphalt -coated, granule surfaced
underlayment used as a valley liner; meets ASTM D3909.
ASTM Organic Mineral Surface Tile Underlayment is an asphalt -saturated organic roll roofing sheet;
meets ASTM D6380, Class M.
0
LeakBarrier EasyMopT1 SBS is a polyester reinforced, SBS modified bitumen roofing underlayment; meets
FRSA/TRI April 2012 (04-12).
4.4 Mechanically Fastened Base Sheets:
LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top
surface; meets FBC 1507.1.1(Exception). Within this Evaluation Report, it is used as a base sheet in multi-
ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top
surface; meets FBC 1507.1.1(Exception). Within this Evaluation Report, it is used as a base sheet in multi-
ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment.
0
LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top
surface and a rubberized polymeric coating on the back surface; meets FBC 1.507.1.1 (Exception). Within
this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No.
FL16884 use as a stand-alone roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation. Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9
Certificate ofAutharization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 3 of 10
�Z_
Q0TR1N1.T'YjERD
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof
covering.
5.5 Allowable Roof Covers:
SABLE Zr ROOF.,COVER OPTIONS { '
Asphalt
Wood Shakes
Underlayment
Shingles
Nail -On Tile
Foam -On Tile
Metal
& Shingles
Slate
BarrierMS300
Yes„
�`NO=�� >.c`No
No
Yes-,,.
Yes,
LeakBarrier PS200"T
:Yes
Yes X
r
Yes,,
'
�Yes
er P5200" °
Yes
Lyo
No
Yes
Yes , r"
Yes
LeakBarrier NR500"T
Yes'
d No
No
Yes
Yes
Yes
" '
�£' r
S
(f�a copper orzinc)
LeakBarrierSS400
;Yes
_ ,a (Vo
No
ipa
Yes
Yes. ,
Yes
Yes
r'
EasyLay
""'Yes
a lies w�
Yes
„�
mUltf=ply,system)
�
N'mul{ply`sVitem).
a s
LeakBarrier EasyLay UDL 15'
Yes �'�Yes
;Yes
Yes
Yes
Yes
UDL Basic or UDL 50
(See FL16884
(as base sheet in
� (as bise sheet in
(See FLi6884)
'
(See F116884)
(See FL16884) wY
multi -ply system} ;-
.- multiply system)
,-V.
Tarco 15
Yes e
�N,o,
ri No _
Yes
Yes
z :Yes k`
;Yes ;`
t
Tarco 30
,YeS
(as�asesheetin
z
(as base sheet in
:x
Yes
Yes
Yes -
rnulticplysyetem)
muRi=ply'system)-
Tarco NO 30
Yes
No ;
No
Yes,_e
- _
es
Yes
Fiberglass Mineral Surfaced
Yes
;
a
Va�ey Uner peg.
��Io4
No '
No
Nos
'
Roll Roofing
19Q7:2.9.2.12)�r#
`
✓, °4
zNo
ASTM Organic Mineral
No
Surface Tile Underlayment
Yes
No
Np
No
LeakBarrier EasyMop SBS
Noy
Yes
Yes
No
No r'No
5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top
layer underlayments.
5.5.2 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
TABLE=� l� ALLOWABLE
TILE ADHESIVE i1NDERLAYMENT CON181NATIONSI ax
Florida Product
Adhesive
Underlayments
Approval
LeakBarrier PS200HT, ASTM Organic Mineral Surface Tile
ICP Adhesives Polyset® AH-160
FL6332
Underlayment or LeakBarrier EasyMop SBS
t Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
Exterior Research and Design, LLC.. Evaluation Report 30880.07.08-R9
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 4 of 10
Q0TR1NrrY1ERD
5.6 Allowable Substrates:
5.6.1 Direct -bond to deck:
LeakBarrier MS300, LeakBarrier PS200HT, LeakBarrier PS200Mu, LeakBarrier NR500"T or LeakBarrier SS400
self -adhered to:
➢ New untreated plywood (unprimed or primed with ASTM D41 primer);
➢ Existing plywood (unprimed or primed with ASTM D41 primer);
➢ New or existing OSB (unprimed or primed with ASTM D41 primer);
➢ Structural concrete (unprimed or primed with ASTM D41 primer).
Note: Torco does not require priming of new or existing plywood or OSB sheathing. New or existing
sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations
where the overlying roof cover is foam -on tile roofing.
5.6.2 Bond to Mechanically Attached Base Sheet:
LeakBarrier MS300, LeakBarrier PS20011T, LeakBarrier PS200mu, LeakBarrier NR500"T or LeakBarrier SS400
self -adhered to:
➢ ASTM D226, Type I or II felt;
➢ ASTM D4869 felt;
➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier
EasyLay UDL 50.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
➢ ASTM D226, Type I or II felt;
➢ ASTM D4601, Type II base sheet.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section
5.6.4 herein, or as tested in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
LeakBarrier MS300, LeakBarrier PS200"T, LeakBarrier PS200Mu, LeakBarrier NR500"T or LeakBarrier SS400
self -adhered to ASTM D41 primed metal (flashing metal, valley metal, etc.)
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for
determination of design wind loads.
#1 Maximum Design Pressure = -75.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered.
Underlayment: LeakBarrier PS200"T, self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9
Certificate afAuthoriration #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL30450-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 5 of 10
TRINITY IERD
#2 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction
Primer: (Optional) ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200MU or LeakBarrier EasyBase,
rolled into place to create continuous bond
Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered
Underlayment: LeakBarrier PS2001T, self -adhered.
#3 Maximum Design Pressure = -217.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
#4 Maximum Design Pressure = -45.0 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
rolls); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
#5 Maximum Design Pressure = -60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
#6 Maximum Design Pressure = -60.0 DO:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
rolls); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
#7 Maximum Design Pressure = -82.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017
Page 6 of 10
T,TRINITYIERD
#8 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mu, self -adhered
Underlayment: LeakBarrier PS200"T, self -adhered.
5.6.4.1 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a
Maximum Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
LeakBarrier EasyLay, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS
shall not be left exposed for longer than 180-days after installation.
LeakBarrier PS200HT shall not be left exposed for longer than 120-days after installation.
LeakBarrier MS300, NR500"T, PS200'u or SS400 shall not be left exposed for longer than 30-days after
installation.
Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12))_
When loading roof tiles on the underlayment.in direct -deck tile assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
Underlayment Tile Profile Staging Method Maximum Slope
LeakBarrier PS200"r
Flat 10-tile stack or 6-tile stack (4 over 2) 6:12
Lugged 6-tile stack (4 over 2) 6:12
LeakBarrier EasyMop SBS Flat 6-tile stack (4 over 2) 5:12
Lugged 6-tile stack (4 over 2) 6:12
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9
Certificate of Autharization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-119
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 7 of 10
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6 3, . LeakBarrier® MS300 PS200"T, PS200Mu, NRS00"' or SS400 Ice and`Water Armor:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
Cut to manageable sections and allow to relax prior to application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8" over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges
➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out.
➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps
minimum 36".
➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner.
➢ Install capped or tin -tagged nails 6" D.C. along the centerline of the laps.
➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave
/ rake areas to ensure a complete bond.
6.3.3 Tile Applications (PS200"T only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top
sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Refer to Section 5.8 for tile staging limitations. If tiles are to be left in a staged condition for more than 30
days, Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to
slope, regardless of the allowance in Section 5.8.
6.3.4 Multi -Ply Underlayment Systems:
LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct -to -
deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically
attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not
a requirement, but is allowable if a multi -ply underlayment system is desired.
Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R9
Certificate ofAuthorization #9503. 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9
Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017
Page 8 of 10
6.4 Tarco 15 arid 30:
6.4.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type I (Tarco 15) or ASTM
D226 Type II (Tarco 30) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be
installed.
6.4.2 Tile Applications (Tarco 30 only):
Tarco 30 is limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI
April 2012 (04-12). Reference is made to Table 1 herein, coupled with FRSA/TRI April 2012 (04-12)
Installation Manual.
6.6.2 Non -Tile Applications:
Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay
lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or
1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center
of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to
avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding
laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water -
shedding side lap.
Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges.
At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point
and work to the high point, rolling the membrane from the center outward in each direction, ensuring no
wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos
free).
6.6.3 Tile Applications, base laver in multi -ply system:
LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the "Two Ply System" from
FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual
Exterior Research and Design, I.I.C. Evaluation Report 30880.07.08-R9
Certificate ofAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10450-119
Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017
Page 9 of 10
6.7.1 Shall be installed in compliance with current Tarco Roofing published installation requirements. For use in
tile applications:
✓ ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier'"" EasyMop SBS are for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from
FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically
fastened or adhered tile roof systems.
6.8 Tile Staging::
6.8.1 Tile shall be loaded and staged in a .manner that prevents tile slippage and/or damage to the
underlayment. Refer to Table 2 herein, and Tarco Roofing published requirements for tile staging.
6.8.2 Battens and/or Counter -battens, as required by the the manufacturer and FRSA/TRI April 2012 (04-12)
must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use
of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading
process.
6.8.3 Tarco Roofing specifies the minimum cure time after installation of self -adhering membranes and before
loading of roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 611320-3 CIA requirements.
The following plants have qualified products under their respective physical properties specifications.
.;Plant
h
Specification
Product s ..,
ASTM D226
LeakBarrier EasyLay, Tarco 15, Tarco 30
ASTM D4869
Tarco NO 30
ASTM D3909
Fiberglass Mineral Surfaced Roll Roofing
Greencastle,
ASTM D6380
ASTM Organic Mineral Surface Tile Underlayment
PA
ASTM D1970
LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice
and Water Armor, LeakBarrier SS400 Ice and Water Armor
ASTM D1970 & FRSA/TRI 04-2012
LeakBarrier PS200HI Ice and Water Armor
FRSA/TRI 04-2012
LeakBarrier EasyMop'" SBS
ASTM D226
LeakBarrier EasyLay, Tarco 15, Tarco 30
ASTM D4869
Tarco NO 30
Belton, TX
ASTM D1970
LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice
and Water Armor, LeakBarrier SS400 Ice and Water Armor
ASTM D1970 & FRSA/TRI 04-2012
LeakBarrier P5200HI Ice and Water Armor
Coshocton, OH
ASTM D1970
HI
LeakBarrier NR500
Gujarat, India
FBC 1507.1.1 (Exception)
LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic,
LeakBarrier EasyLay UDL 50
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3281
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report 30880.07.08-R9
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL104S0-R9
Tarco Roof Underlayments; (254) 913-77SO Revision 9:10/03/2017
Page 10 of 10