Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WIND SPEED & EXPOSURE
CONTRACTOR: South Florida Alumin : ` roducts Inc. DESIGN CRITERIA: Applicable Codes Regulations, and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the . AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category 1. 3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: Vw7 =150 MPH, V� =116 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure B 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Screen Room: Non -Habitable, Unconditioned Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" x 48" x 0.024" composite panel Elite 2000, 2.0 # density foam Florida Product Approval Number FL 7561-R4. Foundation Design Existing concrete No additional concrete footing or slab is required to resist the loads imposed by the proposed construction if the existing slab is a minimum 4" thick with an 8" x 8" thickened slab edge and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved. 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400". 5. All Self Mating Beam Sections are to be stitched with either #14 screws 6" from ends and 24" center to center or # 12 screws 6" from ends and 12" center to center. 6. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: i. Portland Cement Type I, ASTM C 150 ii. Aggregates - Large Aggregate 3/4" max - ASTM C 33 iii. Air entraining +/- 1%- ASTM C 260 iv.Water reducing agent - ASTM C 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: i. Reinforcing Bars - ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All flashing and weatherproofing shall be provided by the contractor. 8. Door location shall be determined by contractor in the field. 9. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. 2X2 2X3XO.070P 2X3XO.070PB 2X3XO.070PB 2X3XO.070PB 2X3XO.070PB 2X2GIRT X X N N (TYP) 1X2 WIND SPEED V EXPOSURE HAVE BEEN DETERMEvED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. -HGSE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS M!'QUIRED BY FIELD INSPECTORS THAT .AY BE NECESBARY IIeN ORDER TO 000661 ST. LI'C7 970UNTY BL n .. _ REVIFIN LD FOR COMP - SIOv 1'2L6'I'`:WE BY D ATE 5. i PLAtI S AND PER1 IIT MUST BE KEPT ON JOB OR -NO L'i1SPECTION WILL BE rdADE. CONCEALED FASTENERS ORATTACHMEM ARE THE RESPONSIEILITyOF THE CONTRACTOR OF RECORD 3'X48'XO.024' 2.0# DENSITY FOAM COMPOSITE PANEL • I■ � o 1 lV A-2 A-2 A-2 A-2 5'-11 S'-11 S'-11 S'-11 S'-11 V-11i' /-2X2 fB'-5' 11 N M' LL o o J_ x IPR \�` IONALSEAL o El❑ CC La Lit OV a d W k p� cc W I i $ LL Z GC W OC am Wm L u d j '-+ ZLLI �z pz �z Qz Z == 0 w W- Z U ., C C J QZ0 N� riim r3� QLLIW O W mm V Z Z C7 0 3 Z Ln LU N N W � p Q i U WLLJ N n. 00 w��c�n IYNOJ tZ Y L0 LL LL DRAWN BY MC DATE DRAWN Aft 11/20/17 REVISION 0 LE1 z 12/28/17 U F y 02/05/18 © - ELITE 2000 COMPOcITE PANEL (FPA:FL7561-R4) SHEET NO: 150MPH/EXP B 3'x48'xO.024' (2.0# DENSITY FOAM) A 1 MAX SPAN:q-q = 17'-4i _ c ILL.' c C a IL LL a LL c z