Loading...
HomeMy WebLinkAboutSPECIFIC PURPOSE SURVEYSCANNED LOT 37 BY BLOCK 3 St Lucie Cot. * N90'00'00"W 300.00' LOT 38 BLOCK 3 — — — — — — — — — — — — — — — — — — — — — — — Ld w 112. 5' 0 w 0 o EXISTING �o F- w LOT 39 o- 0 0 �O Of C6 FORMBOARDS Xa X o BLOCK 3 0 P- o o (DECK) w � z �- o m 112.8' Q 0) Do LOT 40 BLOCK 3 N90°00'00"E 300.00' LOT 41 BLOCK 3 N St.kugle Co. FL oat -p jt� v LEGEND A = CENTRAL ANGLE �P'P���/e� �..� R = CURVE RADIUS L = CURVE LENGTH (C) = CALCULATED (P) = PLAT ` / vV r t FND = FOUND P.E. = PRESERVE EASEMENT IR = 5/8" IRON ROD j"") f E RM T�s FPL = FLORIDA POWER AND LIGHT FFE = FINISH FLOOR ELEVATION !/ ND = NAIL AND DISK P.L.S.= PROFESSIONAL LAND SURVEYOR DESCRIPTION SCALE : 1 "=50' LB = LICENSED BUSINESS P.B. =PLAT BOOK LOTS 38, 39 & 40, BLOCK 3, PLAT OF INDIAN RIVER ESTATES UNIT 5 WMT = WATER MANAGEMENT TRACT R/W = RIGHT-OF-WAY ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 10, DUE = DRAINAGE & UTILITY EASEMENT PAGE 58 OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA U.E. = UTILITY EASEMENT Q$ = SEWER MANHOLE SURVEY NOTES ® = ELECTRIC SERVICE BOX ® =CATCH BASIN 1. This survey is not valid without a signature and original embossed seal of a 0 = SET #5 IR & CAP LB 7056 Florida Professional Land Surveyor. ® = CABLE BOX �c =LAMP POST 2. Description provided by client and/or their agent. ® - WATER METER 3. The last date of field work was April 24, 2018. = BELLSOUTH SERVICE BOX 4. Underground improvements and foundations were not located as part of this -0, = WOOD POWER POLE survey. (— = GUY WIRE 5. All boundary information is based on Boundary Survey provided. C.E. = CONSERVATION EASEMENT 6. The purpose of this survey is to Show existing pool deck formboard locations D.E. = DRAINAGE EASEMENT relative to property lines. P P Y NAVO = EL = ELEVATION NORTH AMERICAN VERTICAL DATUM (1988) 7. Additions or deletions to survey maps or reports by other than the signing = GROUND ELEVATION party or parties is prohibited without written consent of the signing party or parties. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR RIGHT OF WAYS, RESERVATIONS, AGREEMENTS, AND/OR EASEMENTS OF RECORD. SUCH INFORMATION, IF DESIRED, SHOULD BE OBTAINED AND CONFIRMED BY OTHERS THROUGH APPROPRIATE TITLE VERIFICATION. REVISION DESCRIPTION RICHARD C. LAVENTU&E, FLORIDA P.L.S. #5209 DATE REF. JOB NO. DRAWN BY DATE DRAWING NO. 18.0041-585 JOE M 4/25/18 18.0041-585 F.B.,PG. CALCULATED BY SCALE SHEET NO. SKETCH RCL 1"=50' 1 OF 1 SPECIFIC PURPOSE SURVEY PREPARED FOR LOUDEN BONDED POOLS " LAVENTURE & ASSOCIATES, INC. W E PROFESSIONAL SURVEYING AND MAPPING 2552 PETERS ROAD SUITE D LB 7056 (772) 398 R6430 PHONT PIERCE, E FLORIDA774 2)396-6426 FAX