HomeMy WebLinkAboutTIE-DOWN DETALSj SETUP AND INSTALLATION OF SINGLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUND IS ESTABLISHED, THE BUILDING IS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 S-6" 13'-8" 280 S-6" 1 V-8" 240 3'-6" 10'-0" 200 S-6" 8'-0" 160 S-6" 6'-0" 120 S-6" TABLE 2 SKID RUNNER SPACING* SHED WIDTH X1 X2 X3 13'-8" 1'-1q" 1'-104" 1'-104" 11'-8" 2'-8" 6'-4" - 10'-0" V-7" 6'-ton - 8'-0" 0'-9" 6'-6" - 6'-0" 0'-ton 51" - -VALUES ARE FROM END OF JOIST TO CENTERS OF (2) 4"x4" SKIDS ONLY. 13'-8" WIDE SHEDS HAVE (4) SETS OF SKIDS. SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)1"x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD* MATERIAL I 2"xB"x16" 1778LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"xB"x16" 3500LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16'k16" 3950LBS ABS PLASTIC PADS IV 8"x8"x16" 1900LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACITY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SO I C CRETE BLOCKS 8"xB"x16') MAY BE STACKED ON PADS FOR HIGH SETS E RCI . 12 ABS PADS REQ RED .ON 11'-8" I Li ��DSToY . BUILDING DIVISI RE"91e F� S F0i �°®6Y:f°" � TYPE REVIEWEDY 1DATE�1 TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHED SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD SHED WIDTH TYPE - LW*(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" SW/DW 4.15/332 0" TO 6" 6'-0" 1936LB I, II, III, OR IV 1879LB I, II, III, OR IV 11'-8" SW/DW 6.00/480 0" TO 6" 6'-0" 2558LB I, II, III, OR IV 2558LB I, II, III, OR IV 10'-0" SW/DW 5.00/400 0" TO 6" 5'-0" 2400LB I, II, III, OR IV 2400LB I, II, III, OR IV 8'-0" SW 4.00/320 0" TO 6" 6'-0" 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0" SW 3.00/240 Cr TO 6" 6'-0" 1658LB I, II, III, OR IV 1866LB I, II, III, OR IV • LUAU WIDTH OF UPLIFT ON RUNNER NOTES I. PAD SPACING 15 END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. C icRALFD FASTENERS OR ATTACHMENTS AnE THE RESPONSISILITI' OF THE PLANS AND PgRMIT MUST BE KEPT ON JOB OR NO INSPECTION W!!-L UE F.01ADE THESE FL11*1 AP40 ALL PROPOSED WORK ARE SURJRCT I d ANY CORRECTIONS Et�CIR�D 5 FIELD INSPECTORS THAT MAY BE IINEC bSARY IN ORDER TO COMM WITM A" Ate eiG-A&E CODES: GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 4B. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. • LOAD WIDTH OF UPLIFT ON RUNNER ::.LOCATION FROM END WALL OF AUGER ANCHOR ••* MAXIMUM SPACING BETWEEN ANCHORS NOTES 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ARE REQUIRED IF SPACING IS MORE THAN 10'-0" BETWEEN ANCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE AS POSSIBLE. TABLE 4A 30" AUGER ANCHOR SPACING -SINGLE WIDE SHED WIDTH LW* UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** -7;OQr� �243•r 0-0T0*3�-0� --1,p` 11'-8" 6.00 208 0'-0" To 3'-0" t0'-o" 10'-0" 5.00 174 0'-0" TO 3'-0" 10'-0" 8'-0" 4.00 138 0'-0" TO 3'-0" 10'-0" 6'-0" 3.00 104 0'-0" TO 3'-0" 10'-0" TABLE B 30" AUGER ANCHOR SPACING -DOUBLE WIDE SHED WIDTH LW UPLIFT (PLF) END ANCHOR** MAX. INTERIOR SPACING*** 20'-0" 10.00 400 0'-0" TO 3'-0" 5'-0" 8C1L`lNNE" ' BY 2"x2" GALVANIZED WASHER Gi Lucie County 2"x2" GALVANIZED WASHER 'rr`>.- WITH 1/2" NUT 1/2" THREADED ROD r s�� WITH 1/Y NUT .r»�'- r� OPTIONAL FOR "HIGH SET" NOTCH OR COUNTERSINK BOLT 1/2" THREADED ROD _ OPTIONAL FOR "HIGH SET"- '�fy EYES BOLTED TOGETHER WITH 1/2"x2" BOLT &NUT WITH 2 2"x2" GALVANIZED O 1 2" COUPLER / THRU 2"x4" BOTTOM PLATE 2"x4" BOTTOM PLATE NAILED 1/2" COUPEER�+ • = �?." +�- _- • .-- Vy.• �`. WASHERS (2.000LB SHEAR CAPACITY) :_: �; 1/ "x5" 400 LB. CONCRETE TO 2"x6" P.T. BASE 1/2"z12" FORGED EYEBOLT = /9 - 3GRADE 4" MIN. a EDGE ANCHOR INTO SLAB THRUSEE xTAB ----___-� 4" MIN. �.T� EYES BOLTED TOGETHER WITH 1%2 x�'¢ ET1 FORSPACING)L4----- -- BOLT & NUT WITH 2 2"x2" GALVANIZED, -�T PiE I, II, III, OR IV PAD WITH O -, -' ;'�i, '% WASHERS 2.000LB SHEAR C,APl�CI %`- BLOCKING AS REQUIRED (SEE TABLE 3). ( TY)vf y r 1/2"x3" 400 LB.) CONCRETE WEDGE ANCHOR SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CLIP OR EQUAL LOCAL CODES AND JURISDICTION CONCRETE SLAB BY OTHERS THROUGH LOCAL CODES AND JURISDICTION (SEE TABLE 1 FOR SPACING) 30" EARTH AUGER ANCHOR _fan (SEE TABLE 4 FOR SPACING):; ��f� �_. WITH SKID SHED WITH SKID SHED. WITH 'NO FLOOR' OPTION TOSHED AD..OR�BLOCKING" ANCHORED TO CONCRETE ANCHORED TO CONCRETE f_ TIE -DOWN DETAILS CODE VERSION FBC 2017 6th Edition, ASCE-7 MANUFACTURER SUPERIOR SHEDS BUILDING TYPE IUF CTURED BUILDI (f) _ MTB 0 Date: W 4/26/16 Seale: (n N A otlel LJJ ALL � GENERAL NOTES 1. FOUNDATION PLANS ARE NOT PART OF THIS PLAN SET AND ARE GOVERNED BY LOCAL JURISDICTION. LLI 2. THIS BUILDING IS EXEMPT FROM THE FBC ___I ENERGY CONSERVATION CODE PER SECTION 1015.22. m 3. REFER TO TIE -DOWN DETAILS FOR PROPER :D INSTALLATION REQUIREMENTS TO MEET CODE. 0 Cn o •• CENSF •• •. ���i 0 U' i �•�.• STATE OF : 44/ � J lllllll ___I `Matthe T. Baldwin Q `Florida License 84608 z Sheet: AD- 1 OF 1 I- -