Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEti FORM R405-2014 SCANNED Wy FL .ORIDA ENERGY EFFICIENCY CO CF69fty BUILDING CONSTRUCTION Florida Department of Business �' and Professional Regulation R esidential Performance Method Project Name: BELANGER Builder Name: Street: 64 AQUA RADRiVE 'Offl Permit ice: City, State, Zip: JENSEN BEACK, FL, Permit Number: Owner: Jurisdiction; PesignLocation: FL, West Palm Beach County:: MARTIN. COUNTY,(Florida Climate Zone 2) I. New.donstruction or existing Addition 9. Wall Types (368.0 soft.) Insulation Area 2. Single family or multiplefilmily Single-family a. Frame -Wood,. Exterior R=13.0 368-'00 ft2 3. Number of,units,'If multiple family 1 b. NIA c. N/A R= ft2 R= ft2 4. Number of BedvoomaPqdrms. In Addition) 1 (1) d. N/A R= ft2 5. Is this a worst'ca . se? -No 10. Ceiling Types (262.0 sqft.) Insulation Area a. Under Attic (Vented) R=jO;O 262.00ft2 6. Conditioned floor.alrea above grade (ft2) 262 b. N/A R= ft2 Conditioned floor area below grpde.(ft2) o G. NIA R= ft2. 11. Ducts R ft2 7. Windows(75.3 Description Area a. SUI6: Attic, Ret: Attic, AH: ADDITION 6 52 a. U-Factor: 661, U4,65 75.33* ft2 '.='0 SHGC: S HPC � 25, b. U-Factor: NIA ft2 12. Cooling systems kBtu/hr Effic.iengy SHGC: a. Central, Unit. 35.4 SEER:16.'00 q. U-Factor: N/A ft2 SHGC: 13. Heating systems kStu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area, Weighted Average -Overhang Depth: 2.000 ft. Area Weighted Average, SHGC: .0.250 14, Hot water systems - None required 8. Floor Types. (262.9 sqft.) insulation Area Cap: N/A 6. Slab -On -Grade Edge Insulation R=0!0 262.Q0 ft2 b. Conservation features EF:!0.000 b. N/A R= ft2 c. NIA R= ft2 15. Credits Pstat, Total Proposed Modified :Loads: 12.90 Glass/Floor Area.: i0,288 PASS Total _Baseline Loads: 1-31.5-13. I hereby,certify. that the.,.plans and specifications covered by Review of the plans and S. this calculti i n.are in compliance -with the Florida Energy to specifications covered by this Code. calculation -indicates compliance with thb. Florida Energy,Code.. PREPAIqD ELY-- Before poirstructiori,is completed W t fig, 44" DATE:' this building will ,be-Insp6cted for : , 1 01 , , C­ - pompliarIce withSection553.9Q8 ereby. certify -that this I; pliance jdd�ing,asdesigned,is.incom L Florida 84btutes. !th7the-FIori-da-Eher9_Yv1t_0 9.--- BUILPINGOFFICIAL: & rc W_NER/A(-,R DATE:- - 4 DATE` - Compliance reqpires.certification by the air handler unit manufacturer that -the -air handier enclosure qualifies as certified. factory-sealedwl_inadcordanic`�oi� "th R46.3.1-2,11. - Compliance requlres:an Air.Barner*and Insulation Inspection Checklist'in.a.coordprice with R402.4.1.1 and an envelope leakage test report'm,'acdbrdlarice with 940-2.4.1.2.. j",07 =14N, 9115/2017 3:40 PM EnergypaugeO USA- FlaRes2014 Section,R405-4A Comp A Iiant,Software Page 1 of 4 F.O.RM.R405-2014. PROJECT. Title: BELANGER Bedrooms: 1 Address, Type: Street Address Building Type: User. ' ,Contlitioned Area: .262 Lot# Owner: Total Stories: 1 Block/Subpivision: # of Units: 1 Worst Case: No PlatBook: Builder Name:. Rotate Angle: p Street: ti4 AQUA RA. DRIVE Permit Office: Cross Ventilation: Cou.nty: MARTIN COUNTY Jurisdiction: Whole House.Fan: _ City, State, Zip: JENSEN"BEACH , Family Type:, Single,family FL , New/Existirq Addition Comment: CLIMATE, I Design Location IECC Design .Temp TMY Site Zone 97:5 %_. 2.5 %. Int: Design Temp Heating . Winter Summer Degree Days Design :Daily Temp Moisture Range FL, West Palm 'Beach. ' FL WEST PALM_BEAC;, 2 44 go 70. 75 316. 60 Medium BLOCKS Number Name. Area,. Volurne 1 Block1 262 2096 SPACESll ': Number Name Area, Volume Kitchen Occupants Bedrooms Infl ID• „ Finished; Cooled_ Heated, 1. ADDITION- 262. • 2096: No t 1 1 Yes. Yes Yes FLOORS:.` #:.. Floor Type Space ,-,... Perimeter. RValue Area- ;; Tile -; U11ood :Carpet . _ _ _ 1 Slab On -Grade Edge Insulatio ADDITION 72 ft 0. 262 ft2 _ D 0. 1 ROOF' / V # Type Roof Gable Roof Materials Area .Arbat Color Solar SA Absor., Tested Emitt: Emitt Deck Tested Insul. Pitch (deg) 7 •Gable :or shed. : 284 ft2 54 ft2 g Composition•Light, 0.6 No. 0.9 No 0 22.6_shingles ATTIC V # Type Ventilation Vent Ratio (1 in) Area _ ,RBS IRCC _ 1 Full;attic Vented 300,.____ 262ft?:•. N N CEILING, # . Ceiling Type;; Space . R-Value Ins,Type . Area , Framing Frac .. , .Truss 1 ype 1. Under Attic (Vented) ADDITION 30 Blown 262 ft2 0.11 Wood 9/15/2017 3:40,PM Ene.rgyGaugeB.USA.= FlaRes2014.Sectiom.R405.4.1 Compliant: Software Page 2 of 4 FORM R405-2014 WALLS Adjacent#611 'Cavity Width Height Sheathing Framing, $ola.r Below. Space' _ _ o 1 N Exterior , Frame - WoOd __ . ADDITION: 13 26 8: 208,0-ft? 0.23, 0 6< ,,. __. 0 ^,.2 E Exterior Frame - Wood: ADDITION: 13 1' 0: t3 80A_ft? 0.23 0:6 0 3 W Exterior Frame Wood ADDITION. 13 10 8 80;012 0.23 0`6 0 WINDOW5. ,.Orientation showivis the .entered,. -Pro osed orientation - Wall C6perhang' V # Ornt ID :Frame .. Panes . NFRC U-Factor: SHGC Area Depth. Seporat,on.. Iht Shade Screening • . ow1. N Mule- Y7i17 ft? 2.ft 0 •in 1-AA' in Drapes/blinds: " None 2 NI 1� ' Metal, Low-E. Double:_ Yes 0,65 015, 17.712 2 ft'0.iri ' 1.'ft 4'In ' Qrapeslblinds. None 3 N 1 Metal. Low-E Double Yes 0.65 0.25 40 O,itZ_ 2 ft 0 in 1 ft.4 in Drapes/blinds None INFILTRATION Scope Method SLA, - CFM 50 ELA.. E -LA ACH_ ACH;5Q 1 Wholehouse. Proposed ACH(50). :000356 2445 " 13.42 2525 2455; 7 HEATING; SYSTEM system Type . ; _ Subtype; ; Efficiency Capacity Block Ducts' 1 ,..._ Electric'Std Heat None COP 1: 27 kBtu/hr 1 sys#1 CO,OLING;SYSTEM ... #. SystemType SUbtype; Efficiency. -Capacity Air Flow: SHR Block :._• _Ducts ' 1t Central Unit None '`. SEER 16 ;35 4 kBtulhr 1.062 cfm 0:75 1 sys#1 SOLAR HOT WATER SYSTEM -it EC Collector Storage Cert # Company Name 'System Model,# Collector Model#" Area Volume FEF , ft2 DUGTS.. - ---Supply -= Return ,; " Air, CFM' 45 CFM25 HVAC # V # Location R Value 'Area, Location Area Leakage Type . Handler. TOT OUT QN RLF Heat Cool 1- Attic >6 , 52 ftz Attic,,. ." 15;ftz." " ," Default Leakage-_,.ADDlTt0N "(Default)," (Default) 1 1 9/15/2017 3:40,PK Energ90auge®`USA FlaRes2Q14 Section R405.4.4 Compliant Software Page 3 of 4 l=ORM R405-2014 TEMPERATURES Programable Thermostat. Y Ceiling Fans: Cooling Jan Heating f Xj Jan Feb f Xj Feb Mar NlarX] [Xj Apr Ape May May' X Jun X Jul X Aug. X Sep Oct Nov Dec [ j Jan [ ]Feb X Mar Jun' Jul Aug Sep X� Oct X Nov DecVenting Thermostat Schedule.: HERS 2006 Reference. Hours Schedule Type 1 Z 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78: 78 78 78 78 78 78 78 80.80 80 80: PM 80 80 78 78 78 78. 78 78. 78 78 78 78 Cooling'(WEH) AM 78 78 78„ 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating_(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68. 68. 68 68' 88. 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM. 68. 68 68 68 _68 68 681. 68 -68. .68 66 66 9/15/2017 3:40 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant",Software. Page 4 of 4 FORM'R405-2014 TABLE 402.4.-1.1 AIR -BARRIER-AND INSULATION, INSPECTION COMPONENT '' CRITERIA Project Name: BELANGER Builder Name: Street: 64 AQUARA DRIVE Permit Office: City, State, Zip: JENSEN BEACH., FL, Permit Number:. Owner Jurisdiction: Design Location: FL., West Palm Beach COMPONENT CRITERIA, CHECK Air barrier and-thermal'barrier A continuous air barrier shall,be installed -in the'lzuilding,. envelope. Exterior thermal envelope contains. a- continuous barrier. . I 6reaks orjoints:in-thi�alr barrier. shall -be'$qale d Air -permeable insulation shall not be used as a, sealing, material. Ceilin: g/attic The air barder.in any dicipp'ecl' deiling/s6frit shall be aligned with the insulation and any gaps in the'air barrier shall. be sealed. Access openings, 'drop down stairs -or- knee Wall doors to unconditioned attic spaces shall: be sealed. Corners and headers shall be insulated and, the junction',of the foundation Walls and: sill ;plate shall be sealed. The. junction of the top plate -and the top or exterior walls shall,be sealed. Exterior thermal envelope insulation for framed walls shall be installed in . substantial co Mact.'and continuous. alignment -with . rimerii-witli the ,air- barrier.' Kne'ewalls shall be -sealed. Windows, skylights and doors The spacebetween window/doorjambs and framing and skylights and framing shall,be -sealed. Rim joists- Rim joists ,are ,insulated and inclUde,an, -.air barrier. Floors (including above -garage InsQlatiorishall.be:installed to mairitain,pqrmanent contact with underside and cantilevered floors) of.subfidor decking. Theairbarrier shall be installed at any exposed edg6 of insulation. Crawl space walls Where .provided Jn.lieu of floor insulation,, insulation: shall' be' permanently attached to the crawlspace walls. Exposed earth in unv nhad, crawl spaces, shall be covered with a Class'I vapor ret6.rder. with. ove.rlappi n g joints taped. Shafts, penetrations. Duct shafts, utility penet,ra tions, and flue shaft openings to exterior or unconditioned .space ,shall be:sealed.. Narrow: cavities Batts: in narrow cavities shall be cut, to fit, or -narrow cavities shall be filled by insulation. that on installation readily conforms to the :available cavity spaces. Garage separation Air sealing shall, be provided between the garage and conditioned spaces. Recessed lighting Recessed d light fixtures installed in the building thermal -envelope shall be airtight, IC rated, and sealed tothe dryw6tl.. Plumbing and-wir Ing Batt-insulation,Batt-insulation,shall be.cut neatly -to fit around wiring and,plumbing in exterior walls, or insulation that on installation readily. conforms to available space sh.al - I. . e,xt6n:d1b6hind..piping and wiring. Shower/tub on exterior wall Exterior, walls adjacent to shower,s'and tubs shall.be..insulated, and the air, barrier installed rr r insta e separating them from the,showers'and tubs. Electrical/phone.b.ox on The air. barrier- shall, be installed. I behind electrical or communication boxes or air sealed bokei shall be insteilled. HVAC register boots HVAC register boots that penetrate building thermal envelopeshall'be sealed to the sub -floor or -drywall; Fireplace , An.aiir barrier shal,l,be,:instaII6,d,on,firepl6.ce walls.. Fireplaces shall'have gasketed doors A 9/15/201.7 3:40PM EnergyGauge@) USA,- FIaRes20,14 Section R465.4.1 Compliant software Page 1 of 1 FORM .R405-2014 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number.of Bedrooms 5. Is this a worst;case? 6, .Conditioned. floor area (ft2) T Windows** Description a. U-Factor; Dbl, U,=0:65 SHGC: SHGC=0.25 b. U-Factor: NIA. SHGC: c. U-Factor: N/A SHGC: d. U-Factor: NIA SHGC: Area Weighted Average'Overhang Depth Area Weighted Average SHGC:.. 8. Floor Types a. Slab -On -Grade; Edge Insulation b: NIA c. N/A 64 AQUA RAI DRIVE, JENSEN BEACH, FL, Addition 9. Wall Types Insulation Area Single-family a. Frame - Wood; Exterior R=13.0 368.00 ft2 b.. N/A R= ft2 C. N/A R= ft2 d: N/A R= ft2 No 10-Ceiling Types Insulation Area a. Under Attic (Vented) R=jd.6 262:00 ft2 262 b. N/A .R= ft2 Area- c. N/A R= ft2 75.33.ft? 11.,Ducts, R ft2 a. Sup: Attic, Ret: Attic, AH: ADDITION 6 52 ft2 12-Cooling systems kBtu/hr Efficiency ft2' . a: Central;Unit 35.4. SEER:16;00. ft2 13. Heating systems kBtu/hr, Efficiency, a, Electric Strip Heat 21.0 COP:1.60 2:000 ft. 0.250 Insulation Area U. Mot water systems - None; required R=O.Q 262.00ft2 a Cap: N/A R= ft2 R= ft2 b. Conservation features. 15. Credits IRstat I certify that this home has, complied with the Florida Energy _Efficiency Code: for Building Construction throughahe above,energy saving.features'which w.ill,be installed.(or exceeded) in this home before final inspection. Otherwise; a new EPL Display Card will be completed based on installed Code gpmpliant-features. Builder Signature: Date: Address of.New Home: City/FL Zip: *Note: This is not,a Building Energy Rating. If your Index is below 70, your -home may qualify for energy efficient mortgage (EENI) incentives if you obtain a Florida EnergyGauge.Rating., ;Contact the Energy.Qauge, Hotline at (321) 638=1492 or see the.EnergyGauge web site at-energygauge.com for.information and a list of certified Raters. For information about the,Florida Ruilding-Code, Energy Conservation; contact the Florida Building Commission's support staff. **Label required by Section R303.1.3.afthe Florida::Building:Code, Energy:Conservation, if not DEFAULT. 9/16/2017 300 PM EnergyGauge®:U$A - MaRes2014 . Section R405.4.1 Compliant Software Page 1 of 1 SsuN.:ra.xa o„m.Nmc SELANGERAIMMON kW� r - Wrightsoftx Project j �mmary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772 466.6799 Fax: 772466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: Sep 15, 2017 By: For: BELANGER ADDITION 64 AQUA RS DRIVE, JENSEN BEACH, FL �V J AN Q A 9018 I Notes: j......................... 0 Weather: West Palm Beach IAP, FL, US Winter Design Conditions Summer Design Conditions Outside db Inside db Design TD 45 OF Outside db 70 OF Inside db 25 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 13925 Btuh Ducts 5189 Btuh Central vent (72 cfm) 1985 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 21099 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 1384 1384 Volume (fP) 12456 12456 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 93 48 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 17448 Btuh 13 OF 1200 cfm 0.063 cfm/Btuh 0 in H2O 91 OF 75 OF 16 OF L 50 % 60 gr/lb Sensible Cooling Equipment Load Sizing Structure 15141 Btuh Ducts 8565 Btuh Central vent (72 cfm) 1271 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swin multiplier 0.96 Equipmen? sensible load 23977 Btuh -Latent Cooling Equipment Load Sizing Structure 3141 Btuh Ducts 2229 Btuh Central vent (72 cfm) 2937 Btuh Outside air Equipment latent load 8308 Btuh Equipment total load 32285 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1436AJl NA Coil RBHP-21J07SH2 AHRI ref 7493646 Efficiency 13.0 EER, 15.5 SEER Sensible cooling 25200 Btuh Latent cooling 10800 Btuh Total cooling 36000 Btuh Actual air flow 1200 cfm Air flow factor 0.051 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.75 "a u LE "" upy Calculations approved by ACCA to meet all requirements of Maraual`J 2017-Sep-15 15:37:28 wriightsoft° Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ZCN ...ers\Quick CalcslDocuments\BELNAGER ADDITION.rup Calc = MA Front Door faces: N -�1- wrightsoft, Right-&-_Vorksheet __' Job: Entire House Date: Sep 15, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House EXISTING 2 Exposed wall 158.0 ft 113.0 ft 3 Room height 9.0 ft d 9.0 ft heat/cool 4 Room dimensions 27.0 x 42.0 ft 5 Room area 1384.0 ft2 1134.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VL 1213-0sw 0:097 n 2.43 2.k 243 184: 447 '538 18 16 44 53 4A5-20m 0.770 n 19.25 20.08 : 18, 0 347 361 0 : - 0 0 0 .4A'5-2om • 0.770 n ' 19.25 20:08 41 0 785 819 0 0 0 0 _ w 126-0sw 0.697 a 2.43 2.92 468 468 1135 1366 378 378 917 1104 11 VL12Msw 0:097 s 2 43. 2.92 243 198 480.. 578 _ 243 198 . 480` 578 G 1 A-cl orri 1.270 's 31.75 36.04 45 45 1429 :: 1622 45 45 1429 1622 yl 12B-0sw 0.097 w 2.43 2.92 468 448 1086 1308 378 358 868 1045 L G IA-clom 1.270 w 31.75 92.39 20 0 635 1848 20 0 635 1848 0 166-30ad, 0.032 M80 1.79 1384 1384 1107 2480 1134 1134 907 2032 F 22A-tpl 0.989 24.73 0.00 1384 158 3907 0 1134 113 2794 0 61 c) AED excursion 01 29 Envelope loss/gain 1135E 10921 8073 8311 12 a) Infiltration 2567 840 1836 601 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 5 1150 Appliances/other 2000 2000 Subtotal (lines 6 to 13) 13925 15141 1 9910 12061 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13925 15141 9910 12061 15 Duct loads 37% 57% 5189 8565 37% 57% 3693 6823 Total room load 19114 23705 13602 18884 Air required (cfm) 1200 1200 854 956 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrig�tetsoft' 2017-Sep-1515:37:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...ers%Quick CalcsXDocumentslBELNAGER ADDITION.rup Calc = MJ8 Front Door faces: N PF wrightsoft• Right-J - . !VOrksheet Job: Entire House Date: Sep 15, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name EXT. BED NEW FAMILY ROOM 2 Exposed wall 19.0 ft 26.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heatt000l 4 Room dimensions 9.0 x 10.0 ft 16.0 x 10.0 ft 5 Room area 90.0 ft' 160.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V 1213-0sw 4A5-2om 4A5-20m 1213-0sw 1213-0sw 1A-clom 12B-0sw 1A-clom 16B-30ad 22A-tpl 0.097 0.770 0.770 0.097 0 097 1.270 0.097 1.270 0:032 0.989 n n . n ': a s s w w - - 2.43 19.25 19.252, 2.43 2A3. - '31.75 2.43 31.75 0.60 24.73 2.92 20.08 20.01 , 2.92 2,92 36.04 2.92 92.39 1.79 0.00 81 0 : 0 0 0 0 90 0 90. 90 81 A 0 0. 0 0 90 0 90 19 196 0 '0 0 - 0 0` 218 0 72 470 2M .0 0 0 0 0' 263 0 161 .0 144 18: 41 90 . 0. .0 0 0 160 160 85 - 0 0 90 0 0 0 0 160 26 207 347 785 218 0 0 0 0 128 643 249. 361 819 263 0' 0 0 0 287 0 W V►/ t-G C F 61 c) AED excursion -9 1 -20 Envelope loss/gain 956 651 2328 1959 12 a) Infiltration 309 101 422 138 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1265 982 2750 2097 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1265 982 2750 2097 15 Duct loads 37% 57% 471 556 37% 57% 1025 1186 Total room load 1737 1538 3775 3283 Air required (cfm) 109 78 237 166 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vvri htsft` 2017-Sep-1515:37:28 �.- oRig ht-Suite® Universal 2017 17.0.14 RSU 08101 Page t ..ers\Quick Calcs\Documents\BELNAGER ADDITION.rup Calc = MJ8 Front Doorfaces: N