Loading...
HomeMy WebLinkAboutFLOOR PLAN1 v Planning & Development Services Department nt Planning & Development Services Department 1 Building & Regulations Division SCOPE OF WORK.." — — - - a Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462d553 Product Review Affidavit &REAR ADDITION PER PLANS AS SHOWN CONSTRUCT NEW CARPORT DDIT _may THIS IS AN ALTERATION LEVEL 2 AND MUST COMPLY WITH THE FBC 2017 FOR Certification for Design Load Compliance Building Permit # Owners Name BELANGER ADDITION Applicant: EXISTING BUILDINGSy - Project Name: BELANGER ADDITION Project Address: 64 AQUA RA DR. Permit#: Occupancy Type: R Construction Type: V INSTRUCTIONS FOR USE: at This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTI NS USED com late all that a I 1. DESIGN CODE: Florida Buildin Code 2013'•EcjIt on with 2017_Supplements using ASCE 7-10 2. Structure Designed as (check one): End Ple _Partially Enclosed _Open 3 Risk Category: I X 11 III IV Exposure Category: B C X D NOTES: 1) THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. 2) STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3) ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4) ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE (FBC) 2017, FBC 2017 RESIDENTIAL, FBC 2017 PLUMBING CODE, FBC 2017 MECHANICAL CODE, FBC 2017 ENERGY CONSERVATION, AND THE NEC (NFPA' 70) 2014 EDITION. 5) RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC 301. giv \ 6) ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 201`7 FOR EXISTING BUILDINGS. ' I 4. Design Wind Velocity 165 mph 128 ASD N/A LRFD End Zone Width: 5 ft -• — -- Revised 0 01""-�...:..,:,...�,:�.,�...,,,�"`-9....,..,,.V..""-,"."4,.._.,,.m.._.•,..-•�•. �"� S. Mean Roof Height: 15 ft Roof Pitch: :12 3 Parapet: N/A ft Zone 1: 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): �/sIZG�lA�7 25.0 Zone 2: 25.0 Zone 3: 25.0 Zone 4: 43.3 Zone 5: 43.3 Garage: N/A I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the r! y ) l ✓ �✓ 39.7 69.0 102.1 47.0 58.0 N/A wind loads and forces spa hied by current code provisions. 7. Design Loads: Floor: 40 PSF Roof/Dead: 5 PSF Roof/Live: 20 Balcony:, N/A PSF ofl�PA LMLCmd by H1ftC�"PF, _ PAUL WELC P.E. PAUL WELCH P.E'M °-PAULWMX"`E DeName: n Praf: Cart No, Signature: Date:160a;9150 ® aoM "=Ue � L to Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF /CONCENTRATED (n'� 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: g PAUL WELCH INC. 29945 ON PLANT o 9. Is A Conti un,-ogs ad Path Provided? X Yes, Not Applicable Explain Why Not: 10 Design Sod Bearing Pressure: _'100 -PS Soil Test Reports Submitted? _Yes - N�i14hJ l /�1E51`GNPROFE9SIONAL ST EMENT: �ylb*f APE I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to n G p� comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie '+"_ _ - -W WAS -m --� o w-- ii " q County. I also certify that structural elements depicted on these plans provide adequate resistance to the design - � - - U forcers specified: � ����b�� `- p WINDOW / DOOR SCHEDULE t�X14T. 1 IYi+Jts Paul Welch P.E. 29945 / 5115 YIT. li���� Print Name Cert # & Co. Cart Auth.5115 MARK SIZE / TYPE 1 52" WIDE X 49" HIGH HORZ. ROLLER WINDOW Paul Welch Inc. ON PLAN 8/15/20172 72" WIDE X 80" HIGH SLIDING GLASS DOOM Signature, Date, and Seal 1984 S.W. Biltmore St. Suite #114 Port St. Lucie, Ft. 3 72" WIDE X: 80" HIGH CASED OPENING Company Name & Address 4 140" WIDE X 80" HIGH CASED OPENING \ Product opening I Pressu esign es Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows SEE EL VS. +60/-70 P.G.T. HR-510 NOA# 15-0612.14 IMPACT # 43 X 1 3/8" MIN. EMBED SCREWS AT 4" / 15" O.C. MAX Mullions N/ Fixed Glass Block Glass Skylights Sliding Glass Doors SEE EL VS. +/-60 P.G.T. SGD-770 Nf16O629 IMPACT #12 X 1 1/4" MIN. EMBED SCREWS AT 3" / 14" O.C. MAX Swing Type Doors rl/ _ French Doors Gara a Doors __....- �. ,."'".'""--.,•^^-°"""'•.-b^^"'•"'"' '��'.^^^-.m-.+ Hurricane Protection k NT Ni .. NT T'e9 r41 (a0%iS+l R F46FATTACI-UlFtJTSlkeeT� oN l AN ng Material Roofing zr. oj."}XiRBwteT go -eel•S METAL- NJA �tZ e�P ATA-rGFII�L"NT \ 5 DBL 24" WIDE X 80" HIGH SLIDING BARN DOOR E EXISTING WINDOW OR DOOR go -_ M,��c�l Ef�l�"T•1tJG-. �.'oc•F [.salsa. � \ �oe,l= 19L*2f-605a1 t�x l s T l r•._IG, i•T r3T LIT(,Tr r T TT n REVLx'tti tU JIt CUJ RIVIS[ON - -- �I EV[E't{ D BYCE DATE PLANS AND PE MU T BE KEPT ON J 1 OR NO ITSPECTION WILL BE rq t,DE. ------------- [ E\l\\ f Ll�t*oliso V44 in if t I \\ Ir, i'ddii'y. Fl6Tfr' �tN1yHe'7 W 4 ti+by+r w4. fJb'T `7 �LIa.wN ✓ I I v c . PL.BOIC gL6 V.6'hON - '0 0 %sX1S% IEs!(iPAIL( j — — > N a c LU .�i y L� W7 ID°``J ,�°si ALE e 1�C L\/ 7 io 3 i "S�aLe z w._ _. U CONCEITH FASTENERS ORA17ACHMRNTS THE'RESPONSIBILITY OF THE IV GQNTR4CTOROFRECORO 9) - (�1 Iv it, Vq17 , THESE PLANS AND ALL PROPOSED WORK 0 ARE SUBJECT TO ANY CORRECTIONS To F5 V ' C"T`rp� o EOUIRED BY FIELD INSPECTORS THAT - .� ONIPLYWITH ALL APPLICAILACODIp, , V*1D�I�®hY. (7'fP) l5xlsr O �' atLu,r" 3Ul);i1 NON' _ ,J hLoJrJ t?Fu rG0 ` C�✓� �. L �1/ � 'N I f'/9w`SCctlfi - _ \ t'es Asot/4WAIL 1j�r 'lL PFE 4- A� .L'r•t of TABULATION EXIST. LIVING 1,176 Sq. Ft. NEW LIVING - 262 Sq. Ft. CARPORT 480 Sq. Ft. Sq. Ft. TOTAL 1,438 Sq. Ft, PAL11. WELCH INC MECHANICAL ,ELL°'CMICAL CIVIL ENG1A1, E'R/NG / 1984 S. W. 811- MORES': SU/TE# ,f f4 PORTS7' LUC/E FL 34984 PHONE(772)785-9888 EMAIL PWELCHIAfC@AOL.COM PAUL MEL CH, P.E. FLA REG NO.29945 JUN 0 6 2018 FILE POPY