HomeMy WebLinkAboutCONSTRUCTION PLANGENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION 2. THE DESIGN & CONSTRUCTION OF THIS STRUCTURE MUST FULLY COMPLY WITH THE 2020 FLORIDA BUILDING CODE (7TH EDITION), LATEST EDITIONS OF ACI 318, NCMA, NATIONAL FOREST PRODUCT ASSOC., NDS, TPI, AND ANY OTHER NATIONALLY RECOGNIZED ORGANIZATIONS THAT GOVERN THIS BODY OF WORK. 3. TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS FOR BUILDERS APPROVAL. THE SE DRAWINGS SHALL BE SEALED BY A FLORIDA REGISTERED ENGINEER AND REVIEWED BY THE ENGINEER OF RECORD. THE ENGINEER OF RECORD RESERVES THE RIGHT TO MAKE ANY NECESSARY CHANGES TO THE LAYOUT AND OR DESIGN OF SAID DRAWINGS, AND SHALL NOTIFY THE TRUSS M.ANUFACTURERITRUSS ENGINEER OF SAID CHANGES WITHIN 1 WEEK OF RECEIVING THE SUBMITTED SHOP DRAWINGS. 4. ALL WORK SHALL COMPLY WITH ALL LOCAL AND REGIONAL ORDINANCES. DESIGN PARAMETERS FOR WIND LOAD COMPLIANCE Q CD 1. RISK CATEGORY: II T 2. CODE REFERENCE: 2020 FLORIDA BUILDING CODE-R (7TH EDITION) & ASCE 7-16 Lo 3. BUILDING DESIGN: ENCLOSED 66 4. MEAN ROOF HEIGHT: <=15.0' 5. ROOF PITCH: 6/12 uj 6. GCpi: t 0.18 7. WIDTH OF END ZONE: A = 5.4' ~ 8. WIND SPEED: 160 MPH (Vult) 3-SECOND GUST 124 MPH (Vasd) 3-SECOND GUST (USED FOR ANALYSIS) 9. WIND EXPOSURE: C 10. ADJUSTMENT FACTOR: 1.21 11. SUPERIMPOSED LOADS: FLOOR (DEAD) 20 PSF FLOOR (LIVE) 40 PSF ROOF (TOP CHORD DEAD) 7 PSF ROOF (TOP CHORD LIVE) 20 PSF ROOF (BOT. CHORD DEAD) 10 PSF WALL 55 PSF (REINF. CMU) 118 PSF (FRAMED) 12. SHEAR WALLS WERE CONSIDERED 13. A CONTINUOUS LOAD PATH WAS PROVIDED 14. COMPONENT & CLADDING DETAILED N 15. MINIMUM SOIL BEARING PRESSURE IS 2,000 PSF PRESUMPTIVE N CONCRETE NOTES: 1. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF ACI 301 "SPECIFICATION FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. W 2. STRUCTURAL CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ACI 301 AND SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH IN Q 28 DAYS OF 3,000 PSI. UNLESS NOTED OTHERWISE. p 3. CONCRETE, WHEN PLACED, SHALL HAVE A SLUMP OF 4 INCHES PLUS OR MINUS ONE INCH. 4. PROVIDE A MINIMUM OF 6 MIL VAPOR BARRIER AT ALL AIR CONDITIONED SPACES & GARAGES. HOLES IN VAPOR BARRIER ARE NOT PERMITTED. TAPE AROUND ALL SEAMS AND CUT-OUTS. 5. ALL REINFORCING SHALL CONFORM TO ASTM A615 FOR GRADE 60 STEEL/WELDED WIRE MESH TO CONFORM TO ASTM A-185 5.1. PROVIDE CHAIRS AND BOLSTERS 5.1.1. BOLSTERS TO HAVE PLASTIC COATED LEGS AND FEET (IF EXPOSED TO EXTERIOR ELEMENTS) 5.2. ENSURE MESH IS EMBEDDED 1" FROM THE TOP OF THE SLAB. LAP JOINTS AT 8" & TIE. 6. WELDED WIRE FABRIC SHALL BE IN ACCORDANCE WITH ASTM A-185 AND SHALL BE ADEQUATELY SUPPORTED @ 3'-0" O.C. EACH WAY rn 7. THE MINIMUM CONCRETE COVERAGE SHALL BE AS FOLLOWS: -D'p 7.1. CAST AGAINST EARTH: 3" tt1 7.2. EXPOSED TO EXTERIOR ELEMENTS: 1" 7.3. FORMED SURFACES: 1" (a 8. CONSTRUCTION JOINTS DESIGN AND LOCATION SHALL CONFORM STRICTLY TO THE REQUIREMENTS OF THEPLANS AND SPECIFICATIONS. ANY CONSTRUCTION OR CONTROL DESIRED OR PREFERRED BY THE CONTRACTOR SHALL BE APPROVED BYTHE ENGINEER PRIOR TO O CONSTRUCTION OF THOSE AREAS INVOLVED. 0 9. CHECK ALL DRAWINGS AND APPLICABLE MANUFACTURER'S SHOP DRAWINGS FOR LOCATION OF ALL EMBEDDED ITEMS, SUCH AS PIPE SLEEVES, ANCHOR BOLTS, ETC PRIOR TO PLACING CONCRETE. N 10. REINFORCEMENT FOR CONTINUOUS FOOTINGS SHALL BE CONTINUOUS AND SPLICED WITH A FULL 0 INCH LAP. PROVIDE CORNER BARS. Q 11. CONTRACTOR SHALL PROVIDE SAWCUTS IN SLAB @ A MAX. SPACING OF 20 FEET ON CENTER EACH WAY OR WO S.F. AND AT ALL RE-ENTRANT CORNERS. SAW CUT SHALL BE 1/4 OF THE SLAB DEPTH AND SHALL BE PERFORMED AS SOON A3 THE CONCRETE HAS o HARDENED SUFFICIENTLY ENOUGH TO CONTROL THE STRESSES, AN INHERENT PROPERTY OF CONCRETE MICH SOMETIMES RESULTS IN m CRACKS (WHICH IS NOT UNCOMMON) D_ 12. CONCRETE FOR SLABS ON GRADE AND ELEVATED SLABS SHALL HAVE 3/4" LARGE AGGREGATE. "PEAROCK" IA NOT PERMITTED FOR SLABS. 10 13. CONCRETE PORCH OUTRIGGERS, EXTERIOR FORMED AND POURED COLUMNS, AND REINFORCED EXTERIOR SLABS SHALL CONTAIN Co W.R.GRACE DCI-S CORROSION INHIBITOR AT THE RATE OF 2-1/2 GALLONS PER YARD, CONCRETE SHALL HAVL A MAX. W/C RATIO OF 0.04 AND A MIN. DESIGN STRENGTH OF 5000 PSI @ 28 DAYS. 13.1. ELEVATED SLABS SHALL BE TEMPORARILY SHORED UNTIL FULLY CURED. 14. ALL CONCRETE THAT IS ALTERED (WATER, ADDITIVES, ETC) SHALL BE TESTED TO ENSURE STRENGTH REQUIREMENTS ARE MET. CU 15. TERMINATE ALL VERTICAL REINFORCING AT THE TOP AND BOTTOM WITH 10" ACI HOOKS. CD 16. SOILS SHALL BE TREATED. - - N rn FOUNDATION NOTES: 1. SOIL TO BE COMPACTED TO AT LEAST 95% OF MAX. DRY DENSITY AS DETERMINED BY ASTM-1557 (MODIFIED PROCTOR). 0 2. FOUNDATIONS ARE DESIGNED BASED ON PRESUMPTIVE SAFE MINIMUM SOIL BEARING PRESSURE OF 2000 PEF. •v 3. FOOTINGS SHALL BE PLACED ON COMPACTED SOIL FREE OF ORGANIC DEBRIS. a WINDOW AND DOOR NOTES: O 00 1. WINDOWS, DOORS, SHUTTERS, AND ALL COMPONENTS SHALL BE DESIGNED AND INSTALLED PER THE MINIMLM DESIGN PRESSURES AS CD PRESCRIBED IN THESE PLANS. 2. ALL EXTERIOR GLAZING SHALL BE IMPACT RESISTANT OR HAVE PROTECTION PER SECTION R301.2.1.1 OF THE 2020 FBC RESIDENTIAL CODE. PROTECTION SHALL BE DESIGNED FOR THE SAME WIND DESIGN PRESSURES AS THE WINDOWS OR D0ORS THEY ARE COVERING. DI 3. ALL WINDOWS AND DOORS ARE TO BE INSTALLED ON 1X OR 2X PRESSURE TREATED DUCKS, AND AS PER MANUFACTURERS N SPECIFICATIONS UNLESS OTHERWISE NOTED. O CONCRETE MASONRY NOTES: N 1. ALL MASONRY BLOCK SHALL CONFORM TO THE REQUIREMENTS OF ASTM C90 FOR LOAD BEARING CONCRETI. MASONRY. n' 1.1. MIN. PRISM STRENGTH OF 1,900 PSI W/ 3/8" MORTAR JOINTS. O 4. 2. ALL MORTAR SHALL BE A MINIMUM TYPE M OR S MORTAR CL 3. UNLESS SPECIFICALLY SHOWN OTHERWISE PROVIDE "DUR-O-WALL" TRUSS TYPE REINFORCING IN EVERY OTHER COURSE (16" O.C.) 4. ALL LAP SPLICES MUST BE 48 BAR DIAMETERS. d 5. WHERE INDEPENDENT CONCRETE COLUMNS ARE ABUTTED BY MASONRY WALLS, PROVIDE DOVETAIL ANCHORS FOR THE FULL HEIGHT OF p THE COLUMNS. 0 6. ALL CONCRETE MASONRY CONSTRUCTION SHALL CONFORM WITH ACI 530.1/ASCE 7-10/TMS 602, SPECIFICATION FOR CONCRETE MASONRY U STRUCTURES AND ACI 530/ASCE 7-10/TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES ALL CONCRETE MASONRY UNITS SHALL COMPLY WITH ASTM C-90 WITH TYPE M OR S MORTAR COMPLYING TO ASTM II C-270. MASONRY UITS SHALL HAVE A MINIMUM w + COMPRESSIVE STRENGTH OF 2,000 PSI ON THE NET AREA. N 7. ALL 8" EXTERIOR CMU WALL SHALL BE REINFORCED WITH #5 VERTICAL REINFORCING BARS WHERE SHOWN CN ARCHITECTURAL PLANS AT E CENTER OF GROUTED CELL, PROVIDE 9 GA. TRUSS TYPE HORIZONTAL JOINT REINFORCING AT 16" O.C. IN ALL NEW WALLS. PROVIDE ADDITIONAL REINFORCING ON EACH SIDE OF OPENING GRATER THAN 24" WIDE & AT CORNERS & INTER- SECIONS OF WALLS. CARE SHALL 0 BE TAKEN DURING THE CMU WALL ERECTION TO ENSURE THAT CELLS TO BE GROUTED LINE UP PROPERLY,1,ROVIDING A MINIMUM CLEAR AREA OF 10 SQUARE INCHES & MIN. CLEAR DIM. OF 3" PROVIDE SAW -CUT CLEAN -OUT HOLE IN BOTTOM COURSE & REMOVE MORTAR c DROPPINGS FROM CELLS AT END OF EACH DAY. PROVIDE FOOTING DOWELS TO MATCH WALL REINFORCING IIZE & SPACING. LAP SPLICE O REINFORCING 48 BAR DIA. (OR AS SHOWN ON PLANS) & TERMINATE REINFORCING WITH STANDARD ACI HOOFS TO PROVIDE CONTINUOUS E REINFORCING FROM FOOTING TO UPPERMOST TIEBEAMS. TIE VERTICAL REINFORCING TO INSURE PLACEMED'T IS IN CENTER OF WALL. EO 7.1. WHERE 2 VERTICAL BARS ARE SHOWN IN 1 CELL, INSTALL 1 BAR ON THE INTERIOR FACE OF THE WALL &' BAR ON THE EXTERIOR FACE OF THE WALL, 2" FROM THE EXPOSED FACE OF THE BLOCK. 8. PROVIDE BOND BEAM PER PLANS AROUND PERIMETER OF THE BUILDING @ THE TOP OF ALL WALLS AND AT DIST BEARING. N 8.1. BOND BEAM TO HAVE A MINIMUM OF (2) #5 BARS OR (1) #7 BAR TOP AND BOTTOM (UNLESS OTHERWISE K)TED). N 8.2. H-BLOCK TIE BEAM STEEL TO STOP 8" FROM CORNERS WITH (1) #5 CORNER BAR (OR 1 #7) TOP & BOTTON 32" MIN. LAP. U 9. VERTICAL REINFORCEMENT STEEL TO HAVE A 1/2" MIN. CLEARANCE FROM MASONRY. y 10. GROUTED CELLS SHALL NOT EXCEED A 12' CONTINUOUS POUR. Q 11. PROVIDE "CAST-CRETE" (OR APPROVED EQUAL) PRECAST CONCRETE LINTELS AT ALL MASONRY OPENINGS, W LESS NOTED OTHERWISE. 12. ANY EPDXY SHOWN SHALL BE EITHER "HILTI HIT RE 500" WITH "HAS-E" THREADED RODS FOR MASONRY OR "SMPSON XP22' WITH THREADED ROD. 0 12.1. ALL THREADED ROD HOLES TO BE 1/8" DIA. LARGER THAN REINFORCING STEEL OR THREADED ROD FOR IASE OF INSTALLATION. TIMBER NOTES: y 1. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY A FLORIDA REGISTERED ENGINEER FOR ALL LOADS PRESCRIBED. ROOF c`0 TRUSS ENGINEERING SHOP DRAWINGS SHALL INCLUDE TRUSS LAYOUT, DESIGN LOADS, TRUSS REACTION, (0:AD LOAD & LIVE LOAD AND F- DEAD LOAD & WIND LOAD), AND ALL OTHER INFORMATION REQUIRED FOR PROPER TRUSS INSTALLATION, ERECTION AND BRACING CRITERIA. DESIGN OF ROOF TRUSSES SHALL INCLUDE THE UPLIFT EFFECTS OF 160 MPH DESIGN WIND LOADBASED ON THE 2020 FLORIDA Lo BUILDING CODE, 7TH EDITION. rn 1.1. ROOF TRUSSES SHALL NOT BE DELIVERED TO THE CONSTRUCTION SITE MORE THAN 3 DAYS PRIOR TO INSTALLATION, AND SHALL BE STORED IN ACCORDANCE WITH TPI-95. U 1.2. TRUSS ENGINEER SHALL PROVIDE A WEB MEMBER AT ANY AND ALL PITCH CHANGES OF THE TOP AND BOTTOM CHORD, EXTENDING TO PANEL POINT ON OPPOSITE CHORD. MAX. LENGTH OF BOTTOM PANEL SHALL NOT EXCEED 9 FT. EXCEPT k2 SHORT TRUSS HEELS 111 WHERE REQUIRED HURRICANE STRAP WILL BEND OVER TOP CHORD. PROVIDE VERTICAL WEB OVER ALL TRUSS BEARING LOCATIONS. J 1.3. ALL MEMBERS SHALL BE A MINIMUM OF 2 X 4 #2 SYP. LL 1.4. ALL VALLEY SETS SHALL BE FRAMED WITH VALLEY SET TRUSSES AND ATTACHED TO TRUSSES BELOW PER SPECIFIED STRAPPING @ 6' O.C. MAX. ROOF PLYWOOD SHALL EXTEND ON TRUSSES BENEATH ALL OVER FRAMING. OMIT PLYWOOD AID VALLEY SET BOTTOM CHORD BETWEEN TWO TRUSSES FOR ACCESS. 1.5. IN ADDITION TO THE DESIGN LOADS LISTED, THE TRUSSES SHALL BE DESIGNED FOR ADDITIONAL LOADS WHERE APPLICABLE (LE, A/C EQUIPMENT, ETC.) 1.6. DESIGN BOTTOM CHORDS FOR ATTIC TRUSSES FOR LIVE LOAD PER 2020 FBC R301.5. TRUSSES SUPPORTNG MECHANICAL EQUIP. SHALL BE DESIGNED FOR (2) 100 LB POINT LOADS T APART LOCATED ANYWHERE ON THE TOP CHORD. 1.7. TRUSSES MUST BE CONFIGURED TO PROPERLY ATTACH ALL HANGERS SHOWN ON PLANS OR IN SHOP DRAWINGS. TRUSS ENGINEER MUST SPECIFY ALL TRUSS TO TRUSS CONNECTIONS. 1.8. ALL ROOF TRL SSES AND RAFTERS SHALL BE ANCHORED WITH A TRUSS CONNECTOR STRAP AS PER PLAN OR SCHEDULE & A VAPOR BARRIER MUS BE PROVIDED BETWEEN TRUSSES AND CONCRETE. 2. ROOF SHEATHING 3HALL BE A MIN. OF 1/2" (MIN.) CDX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR T D ROOF FRAMING WITH 8d RING SHANK NAILS 6" O.C. AT PANEL EDGES AND 6" O.C. IN THE FIELD. PROVIDE 2" X 4" BLOCKING AT HIPS AND VALLEYS. SPACE NAILS AT 4" O.C. AT BLOCKING. 3. EXTERIOR FRAMEWALLS SHEATHING TO BE SHEATHED WITH A MIN. OF 1/2" (MIN.) APA SHEATHING, SPECIES GROUP 1, SPAN RATING OF 24/0 OR BETTER. U 41LESS OTHERWISE NOTED, INSTALL WITH FACE GRAIN HORIZONTAL. PLY,�OOD SHALL BE 4 PLY MINIMUM. NAIL TO STUDS USING 8d N ILS @ 6" O.C. AT PANEL EDGES AND 8" O.C. IN THE FIELD. DECREASE SPACING PER PLAN. AT SHEAR WALLS, NAIL TO EACH STUD AT THq END OF THE WALLS FOLLOWING THE EDGE SPACING. BACK OUT AND REMOVE ALL NAILS THAT DO NOT FULLY PENETRATE/MISS RAMING MEMBERS.. 4. FLOOR SHEATHING TO BE 3/4" T & G COX SPAN RATED STRUCTURAL PLYWOOD, INSTALLED WITH FACE GRAIN PERPENDICULAR TO FLOOR FRAMING GLUED &NAILED WITH 10d NAILS 6" O.C. AT PANEL EDGES AND 12" O.C. IN THE FIELD. 5. THE MINIMUM LUMI IER GRADES SHALL BE AS SUCH: INT. & EXT. BEARING WALLS, TOP PLATES, WINDOW BUCKS, & HEADERS: SOUTHERN YELLOW PINE #2 O 1 BETTER BOTTOM PLATES A AINST CONCRETE: PRESSURE TREATED SOUTHERN YELLOW PINE #2 OR BETTER 6. ALL TIMBER IN COP TACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED OR HAVE AN APPROVED SEPARATING MATERIAL. 7. ALL NAILS AND METAL HARDWARE EXPOSED TO THE ELEMENTS SHALL BE GALVANIZED. ALL NAILS SHALL BE COMMON WIRE NAILS. SPACE NAILS AT STRAPS S TO NOT SPLIT THE WOOD. \A/INIM I f1Ar% rlChl!'"AI /lr3ITCMIA. 1. DESIGN WIND LOA ON INDIVIDUAL ROOF TRUSSES BASE UPON TRIBUTARY AREA SHALL BE AS FOLLOWS. 2. SEE ROOF PLAN FC R ZONE LOCATIONS. 3. OVERHANGS SHALI. INCLUDE PORCHES, BALCONY ROOFS, ETC. 4. MAXIMUM DEADLO D RESISTING UPLIFT SHOWN BELOW SHALL BE 8 PSF. F R 6:12 OR LESS ROOF PITCH ZONE AREA PRESSURE PRESSURE OVERHANG 1 10 46 26 N.A. 1 20 1 40 22 N.A. 1 50 34 18 N.A. 1 100 28 14 N.A. 2E 10 63 26 75 2E 20 56 22 73 2E 50 47 18 69 2E 100 41 14 66 2R 10 63 26 N.A. 2R 20 56 22 N.A. 2R 50 47 18 N.A. 2R 100 41 14 N.A. 3 10 63 26 89 3 20 56 22 80 3 50 47 18 67 3 100 41 14 58 EXTERIOR COMPONENTS ATTACHED TO THE WALL (SIDING 1. EXTERIOR WALL MEET THE WIND 2. END ZONE IS AT NTS SHALL BE ATTACHED PER MANUFACTURERS REQUIREMENTS TO :S SHOWN. CORNER, UNDER ROOF ZONE 3. INTERIOR ZONE IS REMAINDER. WALL ZONE PRESSURE PRESSURE END 38 PSF 30 PSF INTERIOR 33 PSF 30 PSF ROOFING NOTES: 1. ROOFING MATERIA�S SHALL BE ATTACHED PER MANUFACTURES SPECIFICATIONS TO MEET THE DESIGN CRITERIA I THESE PLANS. 2. ASPHALT SHINGLE SHALL CONFORM TO ASTM D-3161 CLASS "F", ASTM D-7158 CLASS "H" OR TAS 107. OVER ENCLOSED AREAS ROOF ZONE ROOF SLOPE 6:12 OR LESS ROOF SLOPE 7:12 OR MOIRE 2 73 PSF N.A. 3 73 PSF N.A. SOFFITS: ZONE DESIG 4 PRESSURE 2 +3 /-34 PSF 3 +3 /-42 PSF PRODUCT APPROVAL INFORMATION PRODUCT MANUFACTURER MODEL NO. FLORIDA PRODUCT DESIGN MAX. DESIGN APPROVAL NO. PRESSURE PRESSURE SINGLE HUNG PRODUCTS INC.FL 8153.1 134/-36 PSF +50/-50 PSF IMPACT OPAQUE SWING DOORS THERMA TRU DOORS FIBERGLASS FL 20468.1 a31/40 PSF +67/-67 PSF COMPOSITE EDGE GARAGE DOOR RAYNOR IMPACT - FL 15212.4 +29/-35 PSF +37.4/-41.7 PSF BUILDMARK SOFFIT PLY GEM SIDING GROUP VARIFORM FL 32502.1 -42 PSF +157/-54.9 PSF ROOF OWENS CORNING ASPHALT FL 10674.1 +26/-89 PSF OFF -RIDGE VENTS LOMANCO, INC. 770-D FL 3792.2 +Q6/46 PSF HEIGHTS < 33' UNDERLAYMENT TAMKO BUILDING PRODUCTS TAM -FELT FL 12328A +261-89 PSF 2e (2r 9 9 I / \ ------------- I - - - - / - - - - - - - - - - - - - - ;� I 2r _3 I 2e 3 I I ROOF ZONES 3 I ze SCALE: N T.S. O rr II \\ II , FF_- r = r- II I II I II I II I J I� II I I II I I I I i III III III III III II EXISTING -DEMO PLAN SCALE: 3/16" = 1'-0" I 0 2e I 3 I \ / I 2r Zr I --�\ 2r -2�1---- - 2r - i --- I 2e I 3 I Q 5CANNE!, BY St Lucie County REVIEWE FOR CODE CO LIANCE -sr.._-LUCIE COUNTY BOCC N 0 C3 Ln No O � V) > `1 0) rn M U Ui U m 0 qt N O r N N r /"t N .....n r- w di O m:m LU a� =q T G Q E O v a N N N LU N N a o r 00 0 M 0 Z N Ln w > - (L LU aaa I_ LU W I U) a LU of U) oNp a) M a W ❑ m ° a U) OIt U) o J W W W C W U � m w � W a L) D_ H Z U U0 W LU Z 06 w LU 0 O Z (6 .L U J Q a w W m Co o N 0W Z g 0 N (.9 o H PROJ. NO, 21-700 DATE 04/30/2021 SHEET NO. S-1 SHEET 1 OF 5 75 0_ Ln O L(s 0 W i N O N N 00 W 3 6 i lOS V Q1 0 O > Q a U 03 ti 0 00 ca L 03 0 Q) N O N Q a U OS C) O N N O O I r N N CD N _N c Q n. W D_ n 0 Q U_ U) W J n t4" THICK CONCRETE FLOOR SLAB CAP TO ALIGN WITH EXISTING HOUSE, 3,000 P.S.I. MIN. WITH TROWEL SMOOTH FINISH REINFORCED WITH 6" X 6" - W1.4/W1.4 W.W. MESH OR FIBER MESH W/ 8 MIL VAPOR BARRIER X X�a tO 4 4 4 EXISTING FOUNDATION AND SLAB TO REMAIN FOOTING REBAR (2) #5 BARS CONT. QEXTERIOR MONO. FTG. @ NEW CMU WALL SCALE: 1"= V-0" #4 X 12" BAR DOWEL & EPDXY 6" INTO EXISTING FOOTING/SLAB & @ 24" O.C. EXISTING CONCRETE FOUNDATION AND SLAB TO REMAIN V.I.F. OVER POUR SLAB DETAIL Q SCALE: 1" = V-0" � I11T• ra 1 EXIST. CONCRETE BEAM (FIELD VERIFY SIZE & CONDITION)(SIZE TO BE SIMILAR TO DESIGN BASED ON EXIST. DRAWING -SITE INSPECTION REVIEW/IF NOT CONTACT E.O.R. IMMEDIATELY) 14" THICK CONCRETE FLOOR SLAB CAP TO ALIGN WITH EXISTING HOUSE, 3.000 P.S.I. MIN. WITH TROWEL SMOOTH FINISH REINFORCED WITH 6" X 6" - W1.4/W1.4 W.W. MESH OR FIBER MESH W/ 6 MIL VAPOR BARRIER "QUIKRETE" OR EQUAL BONDING AGENT DOWEL & EPDXY (2) #5 X 36" BARS (MIN.) 6" INTO EXISTING BEAM (30" LAP SPLICE)(EA, SIDE WHERE NEW BEAM MEETS OLD) / a° k d r . 4. 4 _ 4, CUTBACK EXIST. CONCRETE BEAM 4" TO ALLOW FOR BEARING J BEAM TIE—IN DETAIL S-2 SCALE: 1" = V-0" (1) #5 BARS CONT. X— v X - v III— I 6" eTYP. THICKENED EDGE S-2 SCALE: 1" = V-0" (1) #5 BARS CONT. 3" MIN. COVER FIBERMESH OR WELDED WIRE MESH. SEE FOUND. NOTES 4 SLOPE CONC, TO DRAIN �s SHOWER RECESS DETAIL S-2 SCALE: 1" = V-0" 3/16" DIA. STAINLESS GABLE TO BE PULLED TIGHT OVE R A/C COMPRESSOR A/C COMPRESSOR SECURE EA. END TO ONC. PAD W/ 5/8" X 3" EMBE EXP. ANCHOR & HOLD-DOWN TAB CRIMP ENDS OF CABLE W/ LEAD SLEEVES OR CABLE CLAMPS 4" CONCRETE PAD a 4 4 Q A/C TIE —DOWN DETAIL SCALE: 1" = V-0" FILL-IN TRENCHES W/ 3000 PSI CONCRETE W1.41WI A W W M W/ 6 MIL VAPOR BARRIER ON WELL COMPACTED, TERMITE TREATED FILL NEW PIPING (BY OTHERS) t d A $ a p e 4 ° d d e. - d ` U d a ad d e NEW FILL-IN OPENING (VARIOUS SIZES - v SEE PLAN) a a 4 e ° 4. n v PRE -CAST SILLS d (CAST-CRETE OR EQ.) SEE SCHEDULE W/ 10" c. ACI HOOKS EA, SIDE TIED TO VERT. STEEL (TYP.) Z IJJ —1N 11 A 5 a e V 4 4 — TIE -BEAM OR DOUBLE BOND BEAM e 10" ACI HOOKS @ EACH BAR 4' #5 VERTICAL BAR IN FULLY GROUTED CELL (EA. SIDE OF OPENING) 4 d. a n y 4 n. °. )TYPICAL CMU (BLOCK) OPENING REINFORCE )TYPICAL F- A/A" = 1'_n" CUT PLUMBING TRENCHES TO INSTALL NEW PLUMBING @ LOCATIONS AS INDICATED ON THE ARCHITECTURAL PLANS DOWEL & EPDXY #5 X 12" BAR 6" INTO EXISTING STRUCTURAL SLAB @ 24" O.C. (AT ALL LOCATION) - EA. SIDE OF TRENCHES EXIST. 4" CONC. SLAB PLUMBING TRENCH CUT —IN REPAIR DETAIL 7 SCALE: 1/2" = V-0" D W THICK BEADS OF POLYURETHANE YX P.T. BUCK SEALANT BEHIND BUCKS (BY BUCK (2) 3L0' THICK BEADS OF POLYURETHANE INSTALLER) M P.T. BUCK SEALANT BEHIND BUCKS (BY SUCH CONTINUOUS BEAD OF POLYURETHANE INSTALLER) SEALANT (INSTALLED BY WINDOW CONTINUOUS BEAN OF WATER CONTINUOUS BEAD OF POLYURETHANE INSTALLER) RESISTANTSERIOR AT SEALANT (INSTALLED BY WINDOW CONTINUOUS BEAD OF WATER RIOR MIYIBGCK JOINT AT INTERIORIEXTENORAND INSTALLER) RESISTANT SEALANT AT MASONRWJBUCK SOLID INFILL OF STUCCO CORNER JOINTS (BY BUCK INSTALLER) JOINT AT INTERIORIEXTERIOR AND SOLID INFILL OF STUCCO CORNER JOINTS (BY SUCK INSTALLER) CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY CONTRACTOR) CMU WATER RESISTANT COATING ON MASONRY OPENING JAMBS (BY POLYURETHANE SEALANT CONTRACTOR) (BY CONTRACTOR) POLYURETHANESEALANT (BY CONTRACTOR) CONTINUOUS BEAD OF SEALANT CONTINUOUS BEAD OF SEALANT ARMATER DAM 0 SHIM GAP (BY AIFhVATER DAM ®SHIM GAP (BY CONTRACTOR) CONTRACTOR) CONTINUOUS BEAD OF POLYURETHANE POLYURETHANE SEALANT SEALANT (INSTALLED BY WINDOW (BY CONTRACTOR) FINISH FLOOR INSTALLER) °" CONTINUOUS BEAD OF WATER RESISTANT SEALANT AT MASONRWBUCK JOINT AT INTERIORIEXTERIOR AND EXTERIOR SILL NOSING FINISH MATERIAL, PITCH SOLID INFILL OF STUCCO CORNER JOINTS (BY BUCK INSTALLER) SILLAWAY FROM DOOR SLAB RECESS 2X P.T. BUCK CMU WATER RESISTANT COATING CMU WATER RESISTANT COATING (2) 318' THICK BEADS OF POLYURETHANE ON MASONRY OPENING JAMBS (BY CONTRACTOR ON MASONRY OPENING dAMB9 (BY CONTRACTOR) MASONRYSILL SEALANT BEHIND BUCKS (BY BUM). INSTALLER) NOTES: • WATER RESISITANT SEAANT AT MASONRY & WOOD BUCKS TO SE'TYVEK FLUID APPLIED FLASHING S JOINT COMPOUND' OR EQUAL NOTES: • WATER RESISTANT SEALANT AT MASONRY &WOOD BUCKS TO BE'TVEK FLUID APPLIED FLASHING&JIQRNT • POLYURETHANE SEALANT UNDER BUCKS & AT WINDOW FRAME TO BE'OYNOMIC I OP BY TREMCO OR EQUAL COMPOUND' OR EQUAL INTERIOR AMATER SEALANT AT WINDOW FRAME IS TO BE'TREMFLEX 834" SILICONRED ACRYLIC LATEX POLYURETHANE SEALANT UNDER BUCKS& AT WINDOW FRAME TO BE TYNOMIC IOB'BY TREMCO OR EO VIAL BY TREMCO OR EQUAL • INTERIOR ARAVATER SEALANT AT WINDOW FRAME IS TO BE'TREMFLEX SW SILICONI2E0 ACRYLIC LATExx • CONSULT WITH WINDOW MANUFACTURER TO DETERMINE ACTUAL SILL RECESS DIMENSIONS AND BY TREMCO OR EQUAL RESULTING BEAM HEIGHTS • ALL EXTERIOR DOORS MUST BE SET IN A RECESS. • VERIFY FINISH FLOOR MATERIAL AND RECESS DEPTH MD BEAM HEIGHT ELEVATION$PRIOR TO POURING SLAB WINDOW WATERPROOFING DETAIL DOOR WATERPROOFING DETAIL SCALE: P - V-0' SCALE: V-1'-0" ■ SILL REINFORCING SCHEDULE OPENING WIDTH SILL DEPTH REINFORCING STEEL WIDTH TO LESS B:: (1)#5 THAN 7' WIDTHS 7' TO B" (2) #3 SIDE BY SIDE LESS THAN 10' WIDTHS 10' TO 12" (4) #3 SIDE BY SIDE LESS THAN 15' CMU W/BGA. LADDER BLOCKING @ EVERY OTHER COURSE 1 OF ACI HOOKS @ EACH BAR SECURE UNDERNEATH BOTTOM CONT. STEEL SLAB/FOUNDATION - SEE DETAILS FILL EXISTING SHOWER W/ CONCRETE TO ALIGN WITH EXISTING HOUSE, 3,000 P.S.I. MIN. WITH TROWEL SMOOTH FINISH REINFORCED WITH 6" X 6" - W1.4/W1.4 W.W. MESH OR FIBER MESH W/ 6 MIL VAPOR BARRIER ■) BS16 im ■ ■ d a TIE;BEAM OR DOUBLE BOND BEAM v .e 7 d. • .d� d' c. � a e 4" 12"O.C. d' MAX. ° ° ,MAX. A a 4. 4 .. ae e 1 b 1 f 1 ROWS OF (2) 1/4" TAPCONS INTO GROUTED MASONRY W/2"EMBED (TYP.) - MIN. (3) ALL SIDES P.T. BUCK AS REQ. BY MANUFACTURER CMU MASONRY WINDOW BUCK ATTACHMENT S-4 SCALE: 3/4' = 1'-0" "NOTE: DOORS & WINDOWS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS TO WITHSTAND THE MINIMUM DESIGN PRESSURES REQUIRED (AS NOTED IN THESE PLANS). MASONRY DOOR BUCK ATTACHMENT SCALE: 3/4' = 1'-0" *NOTE: DOORS & WINDOWS SHALL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS TO WITHSTAND THE MINIMUM DESIGN PRESSURES REQUIRED (AS NOTED IN THESE PLANS). EXISTING FOUNDATION AND SLAB TO REMAIN S-2 d . o TIEpBEAM OR DOUBLE BOND BEAM ° 4 de e d O e 4" 12" O.C. . d.d MAX ° MAX. . a 4' 4"= L eEa ROWS OF (2) 1/4" O TAPCONS INTO GROUTED MASONRY W/ 2" EMBED (TYP.) -MIN. (3) ALL SIDES P.T. BUCK AS REQ. BY MANUFACTURER CMU BB16 1■ ■ BB16 IN I ■I■ it _BB16__ .,,-�.■ ■ I I DOWEL & EPDXY #4 X 12" BAR 8" I INTO EXIST. @ 24" O.C. MAX. I 1 { EXISTING FOUNDATION AND SLAB TO REMAIN I BEAM SCHEDULE MARK TOP SIZE REINFORCING SPACING ELEVATION WIDTHXDEPTH SOT. MID. TOP BB16 8'-0" CASTCRETE OR EQUAL 1 #5 t #7 #5 CORNER BARS LINTEL 8F16 1T/1 B 1. EE = EACH END BAI - BALANCE 2. TYPICAL TIE BEAM IS (2) COURSES OF 8"X16" U-BLOCK. U-BLOCK WITH (1) #5 BAR IN EACH, UNLESS SHOWN OTHERWISE. 3. ALL HEADERS ARE PRECAST LINTELS, UNLESS SHOWN OTHERWISE. 4. LINTELS SHALL HAVE A MINIMUM 4" BEARING ON EACH END (CONTRACTOR/MASONRY CONTRACTOR TO VERIFY ALL LINTELS) EXISTING FOUNDATION AND SLAB TO REMAIN BB16 I ■ JI. l ) On On 5 D • r�lr U Il ( r co ! N 07 N 0 O o m n• > 01 (D E 0 c M c U U c U a t N c L N coLn ti ® I LL wF- ZV OL = LL n. 5 N .. .. I ( ■ 00 O) .... ..... .... _L.. . .. M OQ U) �d 82 CCf p ■ O LL 0 W °� W Q t4" THICK CONCRETE FLOOR SLAB d. d CAP, 3,000 P.S.I. MIN. WITH TROWEL ■ I Z SMOOTH FINISH REINFORCED WITH !, Q 6" X 6" - W1.4/W1.4 W.W. MESH OR O FIBER MESH W/ 6 MIL VAPOR c: Q BARRIER ON COMPACTED TREATED I SOIL - BROOM FINISH Q% W z 0 ■ Z W LL ,wU) 1 QO N ■ BY-V a U N it m. WCIF C[11.1f1`{' n C:, 00 f1) ■ - ■I BB16 _ I■ ■':■ ■ BB16 ■ ■ PROD. NO. 214 — . REVIEWED OR DATE D4/: SHEET NO. CODE COMP ANCE � __ SM LUCIE (� NTY S-104 SHEET 2 OF G a 0) O Lb O W i N O N N CO W OR n OS 0) to O M U Co a ti O 00 Co L fd 0 O a1 Q U Co 0- I­ O 00 N 'o O ti r N CD (n 0) 0) a O a Co a 0 0 Q U <n W J LL FRONT ELEVATION SCALE: 1/4" = V-0" RIGHT SIDE ELEVATION SCALE: 1/4" = V-0" REAR ELEVATION SCALE: 1/4" = V-0" LEFT SIDE ELEVATION SCALE: 1/4" = V-0" El El CD U x0 m0 0 � o O.H. TYR O.H. TYR EXISTING 13'-8" (V.I.F.) MASONRY TIE-IN DETAIL 3/S-2 (2) 36" X 60" SH, V.I.F. EXISTING MASONRY IN -ILL DETAIL 1/S-5 OPENING +32/-43 PSF BEDROOM #2 QSD/CMD (1) 36" X 24" FIXED +33/-44 PSF TH WC CLST 2668 B I-FOI X6 LING 56'-0" (V.LF.) 17 4X4#2 PT SYP 4X4#2 PT SYP COLUMNS COLUMNS (2) 2 X 12 PT #2 SYP BEAM III W/ 1/2" CDX FLITCH PLATE 0 18'-6" 0 u'^ SIMPSON HUC410 k�XiSTEN(" 4'd8" (V.I,F. 1j SIMPSON HUC410 1 jj BATH #2 BATH #1 e N Mfl > 6068 BI-FOLD i+> 3.4. , SD/ry CLST i? z m Z ---------- z Y 2068 w BI-FOLD 9 6 3 10, 2'-4 `T BEDROOM #1 QS /CMD MASONRY TIE-IN DETAIL 3/S-2 IN -ILL DETAIL 1/S-5 ro (n 36" X 60" SH, V.I.F. U(2) EXISTING MASONRY g OPENING +32/-43 PSF I— �D EXISTING WALL TO BE REMOVED ® EXISTING WALL TO REMAIN NEW WALL (WOOD FRAME) L NEW WALL (CMU) NOTE: ALL DIMENSIONS TO BE VERIFIED IN FIELD NOTE: ■ PROVIDE VERTICAL #5 BAR AT ALL CORNERS, EA. SIDE OF WINDOWS & DOORS & @ 4' O.C. MAX. ARCHITECTURAL FLOOR PLAN SCALE: 1/4" = V-0" LINEN 2668 QSD/CMD DEN (1)36"X60"SH +321-35 PSF MASONRY TIE-IN DETAIL 3/S-2 BEDROOM #3 QSD/CMD r � DW w � 10'-10" i KITCHEN I� I REF. ATTIC ACCESS MASONRY TIE-IN c (2) 36" X 60" SH, V.I.F. EXISTING MASONRY r " DETAIL 3/S-3 OPENING ------- I ---+32/-43 PSF I I . I I r FAMILY ROOM ir 2'-0" 13' 10" 1 2, 0" I I I I I G QSD/CMD 5 2'-11" L 6' 0" iv i. 8'-11" G — — — qIr ®" WH/7 �W D GREAT ROOM LAUNDRY IN -ILL DETAIL 3/S-5 MASONRY TIE-IN DETAIL 3/S-2 - LINEN ( SINK�r WC m 2668 BI-FOL o 3'-5 BATH #4 n CLST / 4068 BI-FOLD BEDROOM #4 (2) 36" X 60" SH, V.I.F. (2) 36" X 60- SH, V.I.F. O50/CMD .� EXISTING MASONRY EXISTING MASONRY OPENING OPENING (2) 36" X 60" SH +32/-35 PSF +31/-35 PSF +32/-35 PSF +321-43 PSF l% -- 1, l9' 12: > (2) 12 PT #2 SYP BEA SIMPSON HUC410 ATTACHED X CDX FLITCH PLATE --- _-- 6'-4" W/ (18) 1/4" X 2-3/4" TAPCONS & (10) 10d X 1-1/2" NAILS @ THE 4 X 4 #2 PT SYP " JOIST (TYP.) COLUMNS SIMPSON HUC410 REVIEWED FOILd CODE. -COMPLIANCE 4X4#2 PT SYP r-, o" __. 7'-10" ST. LUCIE COUNTY COLUMNS SQUAREFOOTAGE A/C NON A/C TOTAL MAIN HOUSE 1992 1992 FRONT PARCH 71 71 REAR POFCH 300 300 TOTAL - PROPOSED 1992 371 2363 BOCC :3CANW BY �t Lucie Count/ 7 N O ` • ........ . e-yap Q�$- N IS 6� y�® 0.% C � c d' C v a Yq 3N�" 9 E9 F 3 �q m o S ov d x � Z N w N Q 0 O (n a aaa W w U) a W W 0 On U) m J A 00 L~L1 > D0' O Q 0. M C M C46 Oo N p O o LL > W W W� m Nm0 111 W I Z W > UO c w (D LLJ LL a z w O 0 ��f// m U L d �� w V m rM r0 CO m W 3 Q V V) o {- PROJ. NO. 21-700 DATE 04/30/2021 SHEET NO. S-3 SHEET 3 OF 5 0_ LO L6 0 Lri W 75 i N 0 N N 00 W ro •L (6 C7 0) N O Q .D U c6 O CD N 0 03 (1) 0 O 0) Q U CS ti 0 O N O O ti N N O N 0) d) ,s O d 06 0_ 0 0 Q U_ W J LL R-30 INSULATION SIMPSON HUC410 W/ (18) 1/4" X 3" EMBED. TAPCONS @ THE WALL & (10) 16d NAILS @ THE BEAM ALL GYPSUM BOARD TO CONFORM TO ASTM C5, C22, C28, C35, C59, 061, C587, C631, C847, C933, C1032 AND C1047 AND SHALL BE INSTALLED IN COMPLIANCE WITH ASTM C843/44 3/4" PT FURRING STRIPS @ 16" O.C. (TYP.) W/ R4.1 INSULATION 1/2" DRYWALL (TYP.) EXISTING CMU WALL TO REMAIN EXISTING SLAB AND FOOTING TO REMAIN 2 X 4 LEDGER ATTACHED W/ 1/4" X PORCH CEILINGS TO HAVE A MIN, OF 318" COX (OR EQUAL) ATTACHED TO 1 2" EMBED. TAPCON @ 24" O.C. MAX. THE BOTTOM OF THE TRUSSES USING 8d RING SHANK NAILS @ 4" O.C. AT THE PANEL EDGES AND 8" O.C. IN THE FIELD WITH FINISH (TBD). 2" X 4" RAT 2 X 4 FASTENED TO 2 X 4 LEDGER RUNS ARE TO BE INSTALLED @ 4' O.C. W/ (2)16d NAILS OR (2) #12 X 1-1/2" USING (3) 8d NAILS TOE NAILED (2 S.S. SCREWS @ EA. TRUSS ALONG THE BOTTOM ON 1 SIDE 1 ON THE OPPOSITE) 2 X 4 BLOCKING/ SOFFIT ASPHALT SHINGLES OVER PEEL & STICK NAILER @ 24" O.C. UNDERLAYMENT OVER 5/8" CDX SHEATHING, 12 8d RINK SHANK NAILS @ 6" O.C. AT SEAMS &" .� 6 6" O.C. IN FIELD PRE-ENGINEERED WOOD TRUSSES @ 24" O.C. 6" TRUSS HEEL (UNLESS �' ,�� 2 X 4 ATTACHED TO TRUSS TAIL DIRECTED OTHERWISE) WITH 8d (3) 8d NAILS MIN. (SPACED EVENLY - 4" O.C.) HURRICANE STRAP @ EA. TRUSS - PER SCHEDULE & LAYOUT VENTED SOFFIT to ALUM. DRIP EDGE OVER rVOP. 1 X 6 CEDAR FASCIA OVER 2 X 4 SUB -FASCIA ATTACHED TO TRUSSES W/(3) 16d NAILS EA. TRUSS VINYL VENTED SOFFIT (SEE PRODUCT APPROVAL) (2) 2 X 12 PT #2 SYP BEAM W/ 1/2" CDX FLITCH PLATE FULLY LAMINATED TOGETHER W/ "LIQUID NAIL" (OR EQ.) & ROWS OF (3) 12d NAILS @ EA. END & 12" O.C. THROUGHOUT BEAM ASSY. ATTACHED TO COLUMN W/ SIMPSON CC44 W/ (4) 5/8" S.S. THRU BOLTS @ THE BEAM & (2) 5/8" S.S. THRU BOLTS @ THE COLUMN W/ 2" X 1/4" WASHER & LOCKNUT (EA. SIDE) - NOTE: USE CORNER VERSION WHERE REQUIRED P.T. 4 X 4 WOOD POST, WRAPPED 4" CONCRETE SLAB W/6X6- W1.4/W1.4 WWM OR FIBERMESH ON 6 MIL. VAPOR BARRIER ON WELL COMPACTED, TREATED FILL SIMPSON ABU44 ATTACHED W/ 5/8" X 7" EMBED ALL THREAD W/ 2" X 1/4" WASHER @ EA. POST & (12) 16d NAILS @ THE POST Q WALL SECTION @ REAR PORCH (FRONT PORCH SIMILAR 4 SCALE: 3/4" = V-0" ASPHALT SHINGLES OVER PEEL-N-STICK UNDERLAYMENT OVER 5/8" CDX SHEATHING, 8d RINK SHANK NAILS @ 6" O.C. AT SEAMS & 6" O.C. IN FIELD PRE-ENGINEERED WOOD TRUSSES @ 24" O.C. HURRICANE STRAP @ EA. TRUSS - PER SCHEDULE & LAYOUT —� ICI ALUM. DRIP EDGE OVER 1 X 6 CEDAR FASCIA OVER 2 X 4 SUB -FASCIA ATTACHED TO TRUSSES W/ (3) 16d NAILS EA. TRUSS VINYL VENTED SOFFIT (SEE PRODUCT APPROVAL) DOUBLE BOND BEAM W/ (2) COURSES H-BLOCK WITH (1) 95 BARS CONT. EACH COURSE — VINYL INSULATED IMPACT WINDOWS — INSTALL ALL WINDOWS & DOORS PER FMA/AAMA 200-12 SPECIFICATIONS FOR WATER TIGHT INSTALLATION PRE -CAST SILLS (CAST-CRETE OR EQ.) - OPTION: FORMED AND POURED SILL, SEE DETAIL. 8" X 16" CMU BLOCK W/ 9 GA. LADDER BLOCKING @ EVERY OTHER COURSE STUCCO FINISH EXETRIOR STUCCO INSTALLED IN COMPLIANCE WITH ASTM C 926 & C 1063. 6" TERMITE INSPECTION STRIP REQUIRED R-30 INSULATION I I 1/2" GYP. BD. DRYWALL J STD. OR RECESSED PRE -CAST LINTELS ABOVE WINDOWS, DOORS & LARGER SPANNING OPENINGS W/ (1) #7 BAR TOP COURSE & #5 BAR IN PRE -CAST LINTEL POURED WITH BEAM (CAST-CRETE OR EQ.) ALL GYPSUM BOARD TO CONFORM = O TO ASTM C5, C22, C28, C35, C59, C61, LU C587, C631, C847, C933, C1032 AND x 9 C1047 AND SHALL BE INSTALLED IN Ao COMPLIANCE WITH ASTM C843144 3/4" PT FURRING STRIPS @ 24" O.C. (TYP.) W/ R4.1 MIN. INSULATION 1/2" DRYWALL (TYP.) 4" CONCRETE SLAB W/6X6 - R BARRIER ON WELL ON 6OML. P CTED, TREATED FILL �n Y � a FOOTING SEE DETAILS' �2 TYPICAL NEW WALL SECTION S_4 SCALE: 3/4" = T-0" (1) 2 X 416 #2 SYP. TOP PLATE ATTACHED TO EA. TRUSS USING 16d NAILS NON -LOAD BEARING FRAMED WALL 2 X 4/6 FIRE BLOCKING 2 X 4/6 WOOD STUD WALL @ 16" D.C. (1) P.T. 2 X 4/6 SYP. BOTTOM PLATE W/ 8d CASE HARDENED NAILS @ 18" O.C. CONCRETE SLAB/FLOOR FRAMING INTERIOR SCALE: 3/4" = V-0" SOFFIT ATTACHMENT @ CMU WALL W*NOTE: SCALE1"= V-0" ONLY IF LEVEL RETURN SOFFIT IS NOT USED` 0 0 J LL 0 ro 1/2" GYP. BD. DRYWALL (� CEILING 1/2" GYP. BD. DRYWALL EA. SIDE OF WALL BEARING WALL �d °v _ L L__ I II II ��' 11 II II II II II II --I�--_-III �--1�--�1-�---I�--�--�---I�--�--T--II T LLI --Il - II- ,,-4„ O.H. 6'-0"SETBACK TRUSS HTSM16 X2 VOLUME (CUBIC FEET) A/C BUILDING VOLUME 7 15936 ROOF AREA = 2.575 S.F. 1/300 OF AREA OF ROOF (ATTIC SPACE) EXCEPT. #2 "8.6 SQUARE FEET OF VENTILATION REQUIRED PER FBCR SECTION 806.2 EXCEPTION #2 W/ (40%) 2.56 SQ FT. COMING FROM UPPER VENTILATORS" ACHIEVED W/ "PLYGEM" TRIPLE 4 VINYL (5.87 INA2/FT) AROUND ENTIRE PERIMETER = 9.6 SQ. FT. (3) 2' X 3' "LAMANCO" 770-D OFF -RIDGE VENT = 2.91 SQ. FT. REQ. 8.6 SQ. FT. < 12.5 SQ. FT. PROVIDED STRUCTURAL ROOF FRAMING PLAN SCALE: 1/4" = V-0" 11 6 1'-4" O.H. : I I I I I I I I vxo' I I II II II II II II II II II I I � F_ TSu= : u= : III I III II =II =I' ro HETA16 V III U�jh� \ V / �Ily, Illl V IUI III H1 �/ TS16 III F I _ I :� :� . .. — i— - II II:_:_:_: ,,-4„ I I VAT - - - - - O.H. 6'-0" SETBACK TRUSS HTSM16 X2 PRE-ENGINEERED ROOF TRUSSES 24" O.C. MAX IL �� II II II II II III T - � I II II II II II II I II I II II II II II -1:1= _I I- � II II II II II II � � II II II I II II II -1:1- 1= � �I> II II I / T— I - 77 VENT � I V T II II II �// II II III I I � II II II II II II 1I- -�I II II II II II I II II If II II II II � _� I II II II II II II II II II II II _ II--_ =1:1= : �' II II II II II II II II II II II I II II I II I PRE-ENGINEEREDRIDOF II I II II II II' II: II .I III II L II I=1:I .. / TRUSSES 24" O.C. MAX .. .. .. .. �5^ry .. " Affix' .. .. I II 1I T II . -II-Li II II II II III 1'4" ° I I HETA1 V-0"SETBACK TRUSS O.H:..-_.___._ kA 0 N p �(} 'U N V 0 O U(�(��� m LL a ins/ N 007 , ( N O •s o 2 V of 00 0 0 M O � N U o N O Ln s N N N V{ N tL Z /n Om W IL 3: p $ Q n a 6 y �va�v `o v eLy t=3i18o+e o�' w 0 F N a� 00 0 F CO W aaa LU Ld CO Lu a UJ co J LU CO oe$ a co z a0 O 0 I- .._... -. (0 p w o LL I I EE6 REVWWED FOR C: Lu ¢ ' CODE COMPLIANCE w a (� ST. LUCIE COUNTY _ W SCANW I z BY BOCC St Lucie County (_) OO LL TRUSS CONNECTION SCHEDULE UPLIFT VIAX. UPLIFT HARDWARE CONNECTION NOTES FASTENER SPECIFICATION 1052 1810 HETA16 COMMON TRUSS TO C.M.U. WALL (U.N.O.) (9) 10d X 1 1/2" NAILS 2147 2235 HHETA16 HIP GIRDER TRUSS TO C.M.U. WALL (U.N.O.) (10) 10d X 1 1/2" NAILS 758 1310 HTS16 COMMON TRUSS TO WOOD BEAM (U.N.O.) (16 TOTAL)/(8 EA. SIDE) 10d X 1-1/2" NAILS 964 1110 HTSM16 COMMON TRUSS TO EXIST. WALL (4) 1/4" X 2-1/4" TAPCONS & (8) 10d X 1-1/2" NAILS 1463 1665 HTSM16 X2 COMMON TRUSS TO EXIST. WALL (4) 1/4" X 2-1/4" TAPCONS & (8) 10d X 1-1/2" NAILS (EA.) 4872 4940 VGT HEAVY GIRDER TO C.M.U. WALL (1) 5/8" X 7" EMBED. GALV. OR S.S. ALL -THREAD & (16) 1/4" X 3" SDS 498 1000 MTS12 TRUSS TO VALLEY TRUSS TIE DOWN (U.N.O.) & (14) 10d NAILS (7 EA. SIDE) - TRUSS TO CRICKET FRAMING (1) @ EA. END & 4' O.C. NOTE: 1. ALL TRUSS CONNECTORS ARE SIMPSON STRONG -TIE Z-MAX. (WHERE AVAILABLE) (TYP.) INSTALLED WITH MAXIMUM NAILS, SCREWS, BOLTS AS PER MANUFACTURERS SPECIFICATIONS. 2. ALL TRUSS TO TRUSS CONNECTIONS ARE BY TRUSS ENGINEER (INCLUDING PIGGYBACK STRAPPING/TIE-IN). LL N w LL z in Lu Of �o (� U D h U d w U L m 00 0 3 Q LI� N o V U) F- PROD. NO. 21-700 DATE 04/30/2021 SHEET NO, S®4 4 5 SHEET OF n O) 77 L0 CD Li i W I, W m ro L ro D (n O 0) Q U ro a r O W N �U N 0 (1) (n O Q) Q U ro 0- r` O 00 N O O , N N 0 N U) (1) ro 0 O li 06 d r) Q U_ U) W J LL BLOCK INFILL DETAIL c SCALE: 3/4" = V-0" 2 X 416 DOUBLE TOP PLATE 'XISTING TIE -BEAM OR OUBLE BOND BEAM 5 VERTICAL BAR DOWEL EPDXY INTO EXIST. IE-BEAM 6" MIN. EMBED :A. SIDE OF OPENING) 5 VERTICAL BAR IN JLLY GROUTED CELL .A. SIDE OF OPENING) 5 VERTICAL BAR DOWEL & EPDXY ITO EXIST. FOUNDATION 6" MIN. MBED(EA. SIDE OF OPENING) XISTING FULLY ROUTED CELL (EA. IDE OF OPENING) V.I.F. XISTING CMU KISTING SLAB/FOUNDATION, V.I.F. WINDOW ATTACH HEADER TO TOP PLATES USING. SIMPSON SPH4/6 W/ (10) 10d X 1-1/2" NAILS 0 16" O.C. 0 (2/3) 2 X 12 #2 SYP HEADER W/ - 1/2" CDX FLITCH PLATES FULLY LAMINATED W/ "LIQUID NAIL" (OR EQ.) & NAILED TOGETHER W/ ROWS OF (3) 12d NAILS @ 12" O.C. THROUGHOUT NEW JACK/HEADER ATTACHED TO TOP PLATE USING SIMPSON MSTA24 W/ (8) 10d NAILS EACH SIDE OF STRAP (TYP.) SIMPSON SP4/6 @ 32" O.C. TO STUD, TOP & BOTTOM AND AT EA. KING STUD W/ (6) 10d X 1-1/2" NAILS @ EA. _/ DOOR OPENING 2 X 4/6 PT #2 SYP BOTTOM PLATE ATTACHED TO FOUNDATION W/ 5/8" X 5" EMBED. S.S. OR GALV. "J" BOLTS @ 24" O.C. a AFOUNDATION - SEE PLAN .° .4 r 'A v. C1 p O cl RoFRAMED BEARING WALL DETAIL SCALE: 1/2" = V-0" RESIDENTIAL LOAD CALCULATIONS PER NEC-220.82 A B C OXIMATE SQUARE FOOTAGE = 2,363 FOR ENTIRE HOUSE PANEL APP DESCRIPTION TOTAL LOAD GENERAL POWER & LIGHTING @ 2,363 SQ. FT. x 3 VA 7.1 KVA (2) SMALL APPLIANCE CIRCUITS @ 1,500 VA EACH 3.0 KVA (1) RANGE HOOD 1.2 KVA (2) BATH EXHUAST 0.2 KVA (1) REFRIGERATOR 0.8 KVA (1) MICROWAVE 1.6 KVA (1) RANGE/OVEN 12.0 KVA (1) DISH WASHER 1.8 KVA (1) DRYER 5.0 KVA (1) WASHER 1.5 KVA (1) DISPOSAL 0.9 KVA (1) WATER HEATER 5.0 KVA (1) WELL PUMP (OPTION) 2.0 KVA (1) IRRIGATION PUMP 2.0 KVA ' LAUNDRY SMALL APPLIANCE INCLUDED TOTAL 44.1 KVA 200A SERVICE FIRST 10 KVA @ 100% 10.0 KVA REMAINDER 34.1 KVA@ 40% 13.7 KVA OTHER MOTORS (0.1) @100% 0.1 KVA LARGEST MOTOR AHU (2.1 KVA) @ 125% 2.7 KVA HEAT STRIP 00 KVA) @ 100% 10.0 KVA RESERVED 0.0 KVA RESERVED 0.0 KVA TOTAL PANEL 38.5 KVA PANEL SIZE ( 36.5 KVA / 240V) = 152 AMPS 1. DO NOT SCALE THE ELECTRICAL DRAWING. RE FER TO THE ARCHITECTURAL PLAN AND ELEVATIONS FOR EXACT LOCATION OF ALL E UIPMENT AND CONFIRM WITH OWNERS REPRESENTATIVES. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH j ULL LOCAL RULES AND ORDINANCES. 3, UNLESS OTHERWISE NOTED, ALL CONDUCTOF S SHALL BE COPPER, WITH "THHN" INSULATION FOR SIZE #10 AND SMALLER. CONDUCTORS RGER THAN #10 SHALL HAVE "THWN" INSULATION. ALL CONDUCTORS #10 AND SMALLER MAYBE SOLID. ALL CONDUCTORS #8 AND LARGER SHALL BE STRANDED. 4, OUTLET BOXES SHALL BE RESIDENTIAL GRADE TAMPER RESISTANT IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET LC CATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. 5. DISCONNECT SWITCHES SHALL BE H.P. RATED, HEAVY DUTY, QUICK MAKE, QUICK BREAK, WITH ENCLOSURES AS REQUIRED BY EXPOSURE. 6. THESE PLANS DO NOT SHOW EVERY MINOR DETAIL OF CONSTRUCTION, THE CONTRACTOR IS EXPEC rED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND MEET kLL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKI 4G ORDER. 7. THE ELECTRICAL SYSTEM SHALL BE COMPILE LY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250, NATIONAL ELECTRICAL CODE. g_ ALL MATERIALS SHALL BE NEW AND SHALL BE kR U.L. LABELS WHERE APPLICABLE. 9. ALL WORK SHALL BE PERFORMED BY A LICEN ED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANSHIP MANNER. THE COMPILE rE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENGINEER/ARCHITECT MUSI BE A CONDITION OF THE SUBCONTRACTOR. 10. THE ELECTRICAL INSTALLATION SHALL MEET ILL STANDARD REQUIREMENTS OF POWER, LIGHT COMPANY AND TELEPHONE CC MPANY. 11. CIRCUITS SHOWN ON PLANS ARE TO DETERMI NE LOAD DATA AND PANEL SIZE. THE CONTRACTOR SHALL PROVIDE CIRCUITS TO S JIT JOB CONDITIONS. 12. SEE NOTES ON PLANS FOR OTHER REQUIREM ENTS. 13. FURNISH AND INSTALL LIGHTING FIXTURES AN D LAMPS AS SELECTED BY OWNER. 14. ALL WORK SHALL BE COORDINATED WITH OTF ER TRADES TO AVOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 15. CORRECTION OF ANY DEFECTS SHALL BE CO PLETED WITHOUT ADDITIONAL CHARGE BY CONTRACTOR AND SHALL INCLUDE REPLACEP ENT OR REPAIR OF ANY PHASE OF THE INSTALLATION WHICH MAY BE DAMAGED. 16. ALL REQUIRED INSURANCE SHALL BE PROVID D FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE D RATION OF THE WORK. 17. CHECK ALL EQUIPMENT FOR PROPER VOLT A E, PHASE, AND CURRENT BEFORE CONNECTION TO CIRCUITS. 18. ELECTRICAL CONTRACTOR SHALL CHECK ANC VERIFY EQUIPMENT FURNISHED AGAINST THOSE SPECIFIED OR INTENDED AND REVISE 13RANCH CIRCUITS AS MAY BE REQUIRED WITH PRIOR APPROVAL OF ENGINEERIARCHITECT. AIR CONDITIONING EQUIPMENT AND CONTROI S SPECIFICATION 1, ELECTRICAL CONTRACTOR SHALL INSTALL AL CONTROL RACEWAY (CONDUIT), WIRE INSTALLATION, CONNECTIONS ETC. IN ACCOR ANCE WITH WIRING DIAGRAMS ON AIR EQUIPMENT, 2. A/C / ELECTRICAL PLANS OR DIAGRAMS FURNI SHED BY MANUFACTURER OF THE EQUIPMENT. 3. ALL POWER WIRING FOR THE AIR CONDITIONII IG EQUIPMENT SHALL BE FURNISHED, INSTALLED AND CONNECTED UNDER THIS SECTION OF THE SPECIFICATION. 4. MECHANICAL CONTRACTOR SHALL PROVIDE h IOTOR STARTERS FOR ALL AIR CONDITIONING EQUIPMENT. ELECTRICAL CONTRACTOR SHA PROVIDE ALL CONECTIQNS TO AIR CONDITIONING EQUIPMENT PER MANUFACTUF ERS SPECIFICATIONS. 5. AIR CONDITIONING EQUIPMENT INCLUDES CO DENSOR, COMPRESSOR AND FAN, FAN COIL UNITS, ELECTRICAL STRIP HEATER, THERMOS rAT, ETC. ELECTRICAL NOTES: 1. NEW TYPEWRITTEN CIRCUIT IDENTIFICATION ML ST BE ON PANEL BOARDS A & C. 2. ALL 20 AMP SINGLE POLE BREAKERS SHALL BE ITHER GFCI OR AFCI TYPE OR COMBO. 3. ALL 120V RECEPTACLES IN LIVING/SLEEPING AREAS SHALL BE TAMPER RESISTANT. 4. EXTERIOR 120V RECEPTACLES SHALL BE WATER PROOF GFCL WIRE METHOD: 1. CONDUCTORS SHALL BE THHN/THWN. CONDUC ORS NO. 8 AWG AND LARGER SHALL BE JOINED BY AN APPROVED PRESSURE CONNECTOR. CO NECTION TO GROUND CONDUCTORS NO. 110 AWG AND LARGER SHALL BE CAST BY FUSIBLE ETAL PROCESS. NEW CONDUCTORS IN PANELS SHALL HAVE THEIR FACTORY LABELS VISIBLE TO A PERSON IN THE WORKING SPACE. 2. NO CONDUCTORS SMALLER THAN 12 AWG SHAL BE USED FOR POWER AND LIGHTING, 3. ALL NEW CONDUCTORS SHALL BE COPPER. ALL CONDUCTORS MUST BE INSTALLED IN CONDUIT. IN DRY LOCATIONS "NM" CABLE MAY BE USED IN ACCORDANCE WITH NEC RESTRICTIONS AND REQUIREMENTS. EXPOSED ABOVE GRADE CONDUIT MAY BE "RMC", "GRC", "IMC", "EMT" OR "FMC". "LFNC" SHALL BE USED FOR CU'S AND WATER HEATERS. 4. "FMC" AND "NM" LENGTHS IN EXCESS OF VSHAL L HAVE A SEPARATE GROUNDING CONDUCTOR, UNLESS UL LISTED AS APPROVED FOR GROUND NG AT THE INSTALLED LENGTH. HACR TYPE BREAKER FOR AHUs & CUs 150A METER g (3) 1/O CU IN 1-1/2" C. GRADE TO UTILI y XFMR EXTERIOR INTERIOR LAUNDRY 200A 3C0. PNL-A 120l240V 20/240V I 10 3W 200A GENERATOR 1#6 OONNE� CU BC.W.P.1 1 CU BOND TO 5/8"0x10FT FOOTER STEEL RISER DIAGRAM GND ROD 0 Scale: ELECTRICAL LEGEND TYPE DESCRIPTION DUPLEX RECEPTACLE Fl GROUND FAULT CIRCUIT DUPLEX RECEPTACLE er WEATHERPROOF GFI DUPLEX RECEPTACLE @200 220 VOLT RECEPTACLE SURFACE MOUNTED CEILING LIGHT I� WALL MOUNTED LIGHT O RECESSED CEILING LIGHT OWPCMD SMOKE DETECTOR (110 V) CATS/CABLE (COMPUTERTV) EXHAUSTFAN $ SWITCH 3-WAY SWITCH r=m ELECTRICAL PANEL -'- CEILING FAN \ BEDROOM #2 \ �� OSD/CMD ---- CLST -- -- 1/0 CU THWN 1)#6 GND 1-1/2" C. 0 CLST FRAME IN -FILL WALL SCALE: 3/4" = V-0" / EXISTING HEADER NEW 2 X 8 PT #2 SYP TOP 8, SIDE PLATES ATTACHED TO EXIST. W/ 1/4" X 3" EMBED LAG BOLTS @ 12" O.C. NEW 2 X 8 #2 SYP STUDS @ 16" O.C. EXISTING WOOD STUD WALL NEW IN -FILL 2 X 8 PT #2 SYP BOTTOM PLATE ATTACHED W/ 1/4" X 3" EMBED. TAPCONS @ EA. END & 16" O.C. MAX. .EXISTING SLAB/FOUNDATION r- - - - - - - - - - - - - - - - - � �I I \ FAMILY ROOM \ I BEDROOM #3 OSD/CMD L- i-----/-----------I OSD/CMD / I rz�._.WHO. GFI'le ..., __._ \ I \ �\ a LAUNDRY AT1 C? 0KITCHEN 1 / / / - GFI / 0- a GFI e / qp - I � 1 LL I I # BEDROOM #1 / OSD/CMD / / I I /� U I NOTE: ELECTRICAL LAYOUT ARE SUGGESTIONS ONLY. ALL ELECTRICAL TO BE PER 2020 FBC & 2017 NEC & PERFORMED BY A STATE REGISTERED ELECTRICAL - CONTRACTOR. ELECTRICAL SERVICE TO BE UNDERGROUND SUPPLY. II GREAT ROOM /I OSD/CMD DEN / / \ QSD/CMD ELECTRICAL PLAN SCALE: 1/4" = V-0" g -0 / BATH CLST BEDROOM #4 \ OSD/CMD ICANNEb BY 5t Lucie Count; REVIEWED FOR CODE COMPLIANI ST. LUCIE COUNT BOCC v 7 N p /1 1 U N 1+6„/ N 2 M N U O r rr"rN L_ ua N Co N O 0 `) o) 00 0 Co U Xk _y Q U 0 N N L Ln N '^ FE N 2 N H 2 T Z m OW D- 'S u�7o�F 8; a ; A- s Z �° UJ rt C ®. • •' a Co =q c .g i pt g w f .g a a y d 70 0 b0 3 69 v O � qtiO� o � ro 04 N N Q T O 7 00 0 Uj F K U) 1n a aaa F- W W = U) W U) m a ao O a (n S C') �r iL < 73 C: Oo 0 W 0 > o W w J cz) lY UO LL � W 06 Z z W Q �,� \y Q d ry O J (o Q U L a = Cr U M c� o 0 W 3 g c V N W o I- PROJ. NO. 21-700 DATE 04/30/2021 SHEET NO. S-5 SHEET 0F S