HomeMy WebLinkAboutENERGY EFFICIENCY CODE 4-25-22i. SCAN N U
RECEIVED BY
FORM''K405-2020 9 5 2Q� St Lucie County
FLORIDA ENERGY EFFI'�IN CODE FOR BUILDING CONSTRUCTION
St. Lucie County
Florida Department of Business eft& Wafessional Regulation - Residential Performance Method
Project Name: 2807 Placid Ave Renovation
Builder Name:
Street: 2807 Placid Ave
Permit Office: St Lucie County
City, State, Zip: Fort Pierce , FL, 34982
Permit Number:2202-0026
Owner:
Jurisdiction: 611000
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1532.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1532.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (1992.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1992.00 ft2
6. Conditioned floor area above grade (ft2) 1992
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(262.7 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 300
a. U-Factor: Dbl, U=0.45 262.67 ft2
SHGC: SHGC=0.20
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
54.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.333 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.200
a. Electric Strip Heat
34.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1992.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1992.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.132 Total Proposed Modified Loads: 60.37
PASS
Total Baseline Loads: 62.09
1 hereby certify that the plans and specifications covered by
Review of the plans and
4-TKE STA?,
this calculation are in compliance with the Florida Energy
specifications covered by this
y0��} • ' _ ;FO��
'__,�;,�•��
Code.
calculation indicates compliance
yk�` r�,,r�J-
PREPAR B �
with the Florida Energy Code.
Before construction is completed
_ _ _
DATE: ��� 2
this buildingwill be inspected for
P
c� i. , a
GZ�f
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Energy Code.
Florida Statutes.
CAD
with the
WE'T¢�
OWNER/AG
BUILDING OFFICIAL:
DATE: 02
DATE:
- Compliance re wires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
U PN
_-�
4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliarit Software Page 1 of 4
FORM R40,rj1,t2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
2807 Placid Ave Renovation Bedrooms: 4
User Conditioned Area: 1992
Total Stories: 1
1 Worst Case: No
Rotate Angle: 0
St Lucie County Cross Ventilation:
611000 Whole House Fan:
Detached
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2807 Placid Ave
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34982
CLIMATE
/
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Block1
1992 15936
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1992 15936 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 192 ft 0
1992 ft2
_--_ 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Concrete 2227 ft2 0 ft2 Medium
N
0.96 No 0.9 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1992 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1992 ft2 0.11 Wood
4/24/2022 11:48 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R40f=2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
t
Adjacent
To IA/All Typp Space
Cavity Width Height
R_Value Et In Et In
Sheathing Framing Solar Below
Area R--Value-Eraction-Absor_ -Grad °
1
2
3
4
N
E
S
W
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
4.1 39 9 8
4.1 56 8
4.1 39 9 8
4.1 56 8
318.0 ft2
448.0 ft2
318.0 ft2
448.0 ft2
0 0.75
0 0.75
0 0.75
0 0.75
0
0
0
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
V/
#
Wall
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
4
5
N 1 Vinyl Low-E Double Yes
E 2 Vinyl Low-E Double Yes
W 4 Vinyl Low-E Double Yes
W 4 Vinyl Low-E Double Yes
W 4 Vinyl Low-E Double Yes
0.45 0.2 Y 21.7 ft2
0.45 0.2 Y 120.0 ft2
0.45 0.2 Y , 75.0 ft2
0.45 0.2 Y 6.0 ft2
0.45 0.2 Y 40.0 ft2
1 ft 4 in 1 ft 0 in
1 ft 4 in 1 ft 0 in
1 ft 4 in 1 ft 0 in
1 ft 4 in 1 ft 0 in
1 ft 4 in 1 ft 0 in
None
None
None
None
None
None
None
None
None
None
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254
1328 72.86 136.78
.0902
5
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1 34 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ None
Sing] SEER: 16 54 kBtu/hr 1620 cfm
0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use
SetPnt
Conservation
1
Electric None Main
0.95 50 gal 68.13121
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R4052020 INPUT SUMMARY CHECKLIST REPORT
DUCTS
---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1
Attic 6
300 ft2
Main
99.6 ft2
Default Leakage
Main
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating f Jan
f Feb
Jul
Aug
X� Sep
Oct
Nov
Dec
X
X�
Mar
ki
I
j May
�XjJun
rl
rl
i
�i Oct
�X� Nov
HDecVenting
[ Jan
[ Feb
Mar
Apr
Jun
Jul
Aug
Sep
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM, R445-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
2807 Placid Ave, Fort Pierce, FL, 34982
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1532.00 ft2
b. N/A
R=
ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
11. Ceiling Type and insulation level
Insulation
Area
5. Is this a worst case?
No
a. Under Attic (Vented)
R=30.0
1992.00 ft2
6. Conditioned floor area (ft2)
1992
b. N/A
R=
ft2
7. Windows— Description
Area
c.
R=
ft2
a. U-Factor: Dbl, U=0.45
262.67 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 300
SHGC: SHGC=0.20
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
54.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
34.0
COP:1.00
Area Weighted Average Overhang Depth:
1.333 ft.
Area Weighted Average SHGC:
0.200
8. Skylights Description
Area
15. Hot water systems
Cap:
50 gallons
a. U-Factor(AVG): N/A
ft2
a. Electric
EF: 0.95
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1992.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature le� Date:
Address of New Home: 4VIFL Zi .
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/24/2022 1:40 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1