Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 4-25-22i. SCAN N U RECEIVED BY FORM''K405-2020 9 5 2Q� St Lucie County FLORIDA ENERGY EFFI'�IN CODE FOR BUILDING CONSTRUCTION St. Lucie County Florida Department of Business eft& Wafessional Regulation - Residential Performance Method Project Name: 2807 Placid Ave Renovation Builder Name: Street: 2807 Placid Ave Permit Office: St Lucie County City, State, Zip: Fort Pierce , FL, 34982 Permit Number:2202-0026 Owner: Jurisdiction: 611000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1532.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1532.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (1992.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1992.00 ft2 6. Conditioned floor area above grade (ft2) 1992 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(262.7 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 300 a. U-Factor: Dbl, U=0.45 262.67 ft2 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 54.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.200 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (1992.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1992.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.132 Total Proposed Modified Loads: 60.37 PASS Total Baseline Loads: 62.09 1 hereby certify that the plans and specifications covered by Review of the plans and 4-TKE STA?, this calculation are in compliance with the Florida Energy specifications covered by this y0��} • ' _ ;FO�� '__,�;,�•�� Code. calculation indicates compliance yk�` r�,,r�J- PREPAR B � with the Florida Energy Code. Before construction is completed _ _ _ DATE: ��� 2 this buildingwill be inspected for P c� i. , a GZ�f compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Energy Code. Florida Statutes. CAD with the WE'T¢� OWNER/AG BUILDING OFFICIAL: DATE: 02 DATE: - Compliance re wires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). U PN _-� 4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliarit Software Page 1 of 4 FORM R40,rj1,t2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 2807 Placid Ave Renovation Bedrooms: 4 User Conditioned Area: 1992 Total Stories: 1 1 Worst Case: No Rotate Angle: 0 St Lucie County Cross Ventilation: 611000 Whole House Fan: Detached New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2807 Placid Ave County: St. Lucie City, State, Zip: Fort Pierce , FL, 34982 CLIMATE / v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Block1 1992 15936 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1992 15936 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 192 ft 0 1992 ft2 _--_ 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Concrete 2227 ft2 0 ft2 Medium N 0.96 No 0.9 No 0 26.57 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1992 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1992 ft2 0.11 Wood 4/24/2022 11:48 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R40f=2020 INPUT SUMMARY CHECKLIST REPORT WALLS t Adjacent To IA/All Typp Space Cavity Width Height R_Value Et In Et In Sheathing Framing Solar Below Area R--Value-Eraction-Absor_ -Grad ° 1 2 3 4 N E S W Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main Exterior Concrete Block - Int Insul Main 4.1 39 9 8 4.1 56 8 4.1 39 9 8 4.1 56 8 318.0 ft2 448.0 ft2 318.0 ft2 448.0 ft2 0 0.75 0 0.75 0 0.75 0 0.75 0 0 0 0 WINDOWS Orientation shown is the entered, Proposed orientation. V/ # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Overhang Depth Separation Int Shade Screening 1 2 3 4 5 N 1 Vinyl Low-E Double Yes E 2 Vinyl Low-E Double Yes W 4 Vinyl Low-E Double Yes W 4 Vinyl Low-E Double Yes W 4 Vinyl Low-E Double Yes 0.45 0.2 Y 21.7 ft2 0.45 0.2 Y 120.0 ft2 0.45 0.2 Y , 75.0 ft2 0.45 0.2 Y 6.0 ft2 0.45 0.2 Y 40.0 ft2 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in 1 ft 4 in 1 ft 0 in None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1328 72.86 136.78 .0902 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Sing] SEER: 16 54 kBtu/hr 1620 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.95 50 gal 68.13121 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R4052020 INPUT SUMMARY CHECKLIST REPORT DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 300 ft2 Main 99.6 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating f Jan f Feb Jul Aug X� Sep Oct Nov Dec X X� Mar ki I j May �XjJun rl rl i �i Oct �X� Nov HDecVenting [ Jan [ Feb Mar Apr Jun Jul Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 4/24/2022 11:48 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM, R445-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 2807 Placid Ave, Fort Pierce, FL, 34982 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1532.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1992.00 ft2 6. Conditioned floor area (ft2) 1992 b. N/A R= ft2 7. Windows— Description Area c. R= ft2 a. U-Factor: Dbl, U=0.45 262.67 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 300 SHGC: SHGC=0.20 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 54.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 34.0 COP:1.00 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.200 8. Skylights Description Area 15. Hot water systems Cap: 50 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.95 SHGC(AVG): N/A b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1992.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature le� Date: Address of New Home: 4VIFL Zi . *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/24/2022 1:40 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1