HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
BY
FORM R405-2014 St Lucie Ccluniy
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: JAAR ENTERPRISES, LLC
Builder Name: JC AND SONS HOME BUILDERS, INC.
Street: 5807 SPRUCE DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34982
Permit Number: 1801-0555
Owner:
Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1747.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - EXt Insul, Exterior
R=4.1 1499.00 ft2
b. Frame - Wood, Adjacent
R=11.0 248.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bsdrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1781 0 sgfQ
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1781.00 ft2
6. Conditioned floor area above grade (ft2) 1781
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA .
R= ft2
11. Ducts
R ft2
7. Windows (216.3 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
a. U-Factor: Sgl, U=0.58 126.33 ft2
SiiGC: SHGC=0.24
b. U-,=actor: Sgl, U=0,65 60.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
30.0 SEER:16.00
c. L-=actor: Sgl, U=0.62 30.00 ft2
S.HGC• SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
,ores W eighled Average Overhang Depth: 1.500 ft.
Area 1^; sighted Average SHGC: 0.229
14. Hot water systems
8, t=loc;�,. Tes (1781.0 sgfLInsulation Area
a. Electric
Cap: 40 gallons)
a. S:Gc-On-Grade Edge Insulation R=0.0 1781.00 ft2
b. Conservation features
EF:0.980
b. N,,A R= ft2
None
R= ft2
15. Credits
None
Glass/Floor Area:' 0.121 Total Proposed Modified
Loads: 59.32
PASS
Total Baseline
Loads: 63.10
I haret)y certify that the plans and specifications covered by
Review of the plans and
-f%E ST,gT
this ara in ccn;pliarca with the Florida Energy
specifications covered by this
Rr 80�,
Code.
calculation indicates compliance
ii�,�' �_�,.-',.�����
PRF;
with the Florida Energy Code.
DATE:
Before construction is completed
this building will be Inspected for
compliance with Section 553.908
* °
I hera_y ccut;fy that this building, as designed, Is in compliance
Florida Statutes.
1�
wit(^ the Florida Energy Code.
G'OD W v
O%A' R!fiGENT
BUILDING OFFICIAL:
DAY:=: -
DATE:
- Comol;arce �,aquires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certifled factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection checklist in accordance with R402.4.1.1 and starting July 1, 2017
ALL FiRO =CT5 require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1.2).
RECEIVED
APR 0 4 2018 File Copy
ST. L'01O �Ob
3,2•o2J:o 7.-iy ASV �, I 9�ll �S - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title: JAAR ENTERPRISES, LLC
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1781
Lot #
Owner Name:
Total Stories: 1
Block/SubDivision:
ff of Units: 1
Worst Case: No
PlatBook:
Builder Name: JC AND SONS HOME BUILD
Rotate Angle: 0
Street:
5807 SPRUCE DRIVE
Permr:O`fi�-a: ST LUCIE COUNTY
Cross Ventilation: No
County.
St. Lucie
Jurisdiction: ST LUCIE COUNTY
Whale House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Single-family
FL, 34982
Nev:/Existing: New (From Plans)
i Ceniment:
CLIMATE
Design Temp
lnt Design Temp
Heating
Design Daily Temp
Design Location TMY Site
97.5%
2.5 %
Winter
Summer Degree Days Moisture
Range
r^~_ FL, Fort Pierce FL VERO BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
i Entire House 1781
19328
SPACES
N arna Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 BEDROOM 2 188
1504 No
0
1
1
Yes
Yes
Yes
`) 2 CLST 2 20
160 No
0
1
Yes
Yes
Yes
3 BATH 2 50
400 No
0
1
Yes
Yes
Yes
CLST 3 20
160 No
0
1
Yes
Yes
Yes
5 BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
6 LIVING ROOM 300
4200 No
0
1
Yes
Yes
Yes
7 FOYER DINING RO 240
3360 No
0
1
Yes
Yes
Yes
ii NOOK 130
1820 No
0
1
Yes
Yes
Yes
9 KITCHEN 130
s
1820 Yes
0
1
No
Yes
Yes
-0 LAUNDRY 70
560 No
0
1
Yes
Yes
Yes
-1 MASTER BEDROO 280
2520 No
0
1
1
Yes
Yes
Yes
s 2 M WIC 54
432 No
0
1
No
Yes
Yes
i -,3 NI BATH 109
872 No
0
1
Yes
Yes
Yes
1 HALL 21
168 No
0
1
No
Yes
Yes
FLOORS.
j K Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -Or, -grade Edge Insulation BEDROOM 2 27 ft 0
188 ftz
1 0
0
i
2 S!�b-Or.-Grsda Edge Insulation CLST 2 2 ft 0
i
20 ftz
__�
1 0
0
_^ 2 S'sb-Cn-Grade Edge !nsulation BATH 2 5 ft 0
i
50 ft2
1 0
0
A S!ab-On-Grade Edge Insulation CLST 3 2 ft 0
20 f?
----
1 0
0
3/2.2r2018 ::-49.Atv! EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R=Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulation
BEDROOM 3 26 ft
0
169 ft2
1
0
0
6 Slab -Or. -Grade Edge Insulation
LIVING ROOM 15 ft
0
300 ft2
____
1
0
0
7 S!nb-On-Grade Edge Insulation
FOYER DINING 15 ft
0
240 ft2
1
0
0
8 Slab -On -Grade Edge Insulation
NOOK loft
0
130 ft2
_--
1
0
0
9 Slab -On -Grade Edge Insulation
KITCHEN 1 ft
0
130 ft2
____
1
0
0
10Slab-Or.-Grade Edge Insulation
LAUNDRY 7 ft
0
70 11:2
__e
1
0
0
11Sleb-Or.-Grade Edge Insulation
i
MASTER BEDRO 35 ft
0
280 ft2
1
0
0
12Slah-On-Grade Edge Insulation
M W IC 1 ft
0
54 ft2
1
0
0
f
Ii 13S!ab-On-Grade Edge Insulation
M BATH 9 ft
0
109 ft2
____
1
0
0
! 14S!ab-On-Grade Edge Insulation
HALL 1 ft
0
21 ft2
1
0
0
l
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
r
Area
Color
Absor. Tested
Tested
Insul.
(deg)
". Hip Composition shingles 1992 ft2
0 ft2
Medium
0.6
No
0.9
No
20
26.6
E
ATTIC
V
it; Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
- ? Full attic
Unvented
0
1781 ft2
N
N
CEILING
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
? Under Attic (Unvented)
BEDROOM 2
20
Blown
188 ft2
0.1
Wood
2 Under Attic (Unvented)
CLST 2
20
Blown
20 ft2
0.1
Wood
3 Under Attic (Unvented)
BATH 2
20
Blown
50 ft2
0.1
Wood
Ender Attic (Unvented)
CLST 3
20
Blown
20 ft2
0.1
Wood
Under Attic (Unvented)
BEDROOM 3
20
Blown
169 ft2
0.1
Wood
i 6 Under Attic (Unvented)
LIVING ROOM
20
Blown
300 ft2
0.1
Wood
7 Under Attic (Unvented)
FOYER DINING
20
Blown
240 ft2
0.1
Wood
i 8 Under Attic (Unvented)
NOOK
20
Blown
130 ft2
0.1
Wood
I 9 Unoer Attic (Unvented)
KITCHEN
20
Blown
130 ft2
0.1
Wood
I UneerAttic (Unvented)
LAUNDRY
20
Blown
70112
0.1
Wood
11 Under Attic (Unvented)
MASTER BEDRO
20
Blown
260 ft2
0.1
Wood
I 12 Unoer Attic (Unvented)
MWIC
20
Blown
54ft2
0.1
Wood
13 Unoer Attic (Unvented)
M BATH
20
Blown
109 ft2
0.1
Wood
14 Unoer Attic (Unvented)
HALL
20
Blown
21 ft2
0.1
Wood
3/22/2018 5�:49 AM EnergyGaugel) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar
Below
t AI
_ 1
S
Exterior
Concrete Block - Ext InstBEDROOM 2
4.1
14
0
8
0
112.0 ft2
0
0
0.6
0
_ 2
W
Exterior
Concrete Block - Ext InsSEDROOM 2
4.1
13
0
8
0
104.0 ft2
0
0
0.6
0
3
S
Exterior
Concrete Block - Ext Insul CLST 2
4.1
2
0
8
0
16.0 ft2
0
0
0.6
0
_ 4
S
Exterior
Concrete Block - Ext Insul BATH 2
4.1
5
0
8
0
40.0 ftz
0
0
0.6
0
_ 5
S
Exterior
Concrete Block - Ext Insul CLST 3
4.1
2
0
8
0
16.0 ft2
0
0
0.6
0
_ 6
E
Exterior
Concrete Block - Ext InsEEDROOM 3
4.1
13
0
8
0
104.0 ft2
0
0
0.6
0
_ 7
S
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1
13
0
8
0
104.0 ft2
0
0
0.6
0
_ 8
W
Exterior
Concrete Block - Ext InsWIVING ROO
4.1
15
0
14
0
210.0 ft2
0
0
0.6
0
_ 9
E
Exteror
Concrete Block - Ext InstffOYER DINI
4.1
15
0
14
0
210.0 ft2
0
0
0.6
0
10
W
Exterior
Concrete Block - Ext Insul NOOK
4.1
10
0
14
0
140.0 ft2
0
0
0.6
0
11
E
Exterior
Concrete Block - Ext InsuILAUNDRY
4.1
7
0
8
0
56.0 ft2
0
0
0.6
0
12
N
Exterior
Concrete Block - Ext InsMASTER BE
4.1
17
0
9
0
153.0 ft2
0
0
0.6
0
! 13
W
Exterior
Concrete Block - Ext InsLWASTER BE
4.1
18
0
9
0
162.0 ft2
0
0
0.6
0
_ 14
N
Exterior
Concrete Block - Ext Insul M BATH
4.1
9
0
8
0
72.0 ft2
0
0
0.6
0
_15
E
Garage
Frame - Wood M BATH
11
21
8
168.0 ft2
0
0 0.600000
0
.16
N
Garage
Frame - Wood FOYER DIN[
11
10
8
80.0 ft2
0
0 0.600000
0
'
i
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Area,
Depth
Separation
Int Shade
Screening
i
1
W 2
Metal Low-E Single Yes
0.58
0.24
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
2
S 4
Metal Low-E Single Yes
0.58
0.24
6.0 ft2
1 ft6 in
1 ft 4 in
None
None
i
3
E 6
Metal Low-E Single Yes
0.58
0.24
15.0 ft2
1 ft 6 in
1 ft4 in
None
None
4
W 2
Metal Low-E Single Yes
0.65
0.21
60.0 ft2
1 ft 6 in
1 ft4 in
None
None
5
E 9
Meta! Low-E Single Yes
0.58
0.24
30.0 ft2
1 ft 6 in
1 ft 4 in
None
None
6
E 9
Metai Low-E Single Yes
0.58
0.24
6.7 ft2
1 ft 6 in
1 ft 4 in
None
None
j
7
E 9
Metal Low-E Single Yes
0.58
0.24
6.7 ft2
1 ft 6 in
1 ft4 in
None
None
f
E
E s
Metal Low E Single Yes
0.58
0.24
20.0 ft'
1 ft 6 in
1 ft 4 in
None
None
!
9
W 10
Metal Low-E Single Yes
0.62
0.22
30.0 ft2
1 ft 6 In
1 ft 41n
None
None
10
W 13
Meta! Low-E Single Yes
0.58
0.24
15.0 ft2
1 ft 6 in
1 ft 4 in
None
None
11
N 14
Me' ai Low-E Single Yes
0.58
0.24
12.0 ft2
1 ft 6 in
1 ft 4 In
None
None
GARAGE
i
x
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
462 ft2 462 ft2
31 ft
8 ft
11
3l22, 2013 9:49 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
INFILTRATION
# Scope Method
SLA
CFM 50 EI.A EgLA ACH ACH 50
1 Wnciehouse ProposedACH(50)
.000483
2254.9 123.79 232.81 .3524
7
HEATING SYSTEM
77 # System Type
Subtype
Efficiency Capacity
Block
Ducts
i 1 Electric Strip Heat
i
None
COPA 27 kBtuthr
1
sys#1
COOLING SYSTEM
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit
Split
SEER: 16 30 kBtulhr 900 cfm
0.8 1
sys#1
HOT WATER SYSTEM
y/ 4 System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Attic
0.98 40 gal 60.9 gal 120 deg
None
I
SOLAR HOT WATER SYSTEM
FSEC
i Cerz # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
i
None None
ft2
DUCTS
/ -- Supply - —
r Location R-Value Area
— Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Adic 6 140 ft2
Attic
14 ft2 Default Leakage Garage (Default) c(Default) c
1 1
"
TEMPERATURES
Prcgrmable Thermostat: N
I
Cmlino H Jan H Feb f Mar
Heating Jan Feb [X� Mar
Verrr-� Jan Feb[[fix)) Mar
Ceiling Fans:
Apr May [X] Jun [X� Jul Auge
f Apr f May [ ] Jun E ] Jul AuSep E
[X] Apr [ ]]] May [ ]Jun ]Jul Aug Se [X]
Oct Nov
Oct Nov
Oct Nov
Dec
Dec
Dec
312212018 9:49 AM EnergyGaugel) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6
i
FORM R405-2014
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling ONC)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cec,'.rg tWEH1
AM
78
78
78
78
78
78
78
78
80
80
80
80
PP11
80
80
80
80
78
78
78
78
78
78
78
78
Heating (WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
1
PM
68
68
68
68
68
68
68
68
68
68
68
68
3/22/2018 9:49 AM EnergyGauge® USA - RaRes2014 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:. JAAR ENTERPRISES, LLC Builder Name: JC AND SONS HOME BUILDERS, INC.
StrFe:: 5807 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: 1801-0555
Owner: Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air carder and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains ;a continuous barrier.
j
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Celiin•7/- sic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors .to unconditioned
�r
attic spaces shall be sealed.
4
#
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
I The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope Insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
i
p The space between window/doorjambs and framing and skylights and
P
t Rim E ioists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and Grdlevered floors)
of subfioor decking.
The air barrier shall be installed at any exposed edge of insulation.
Cra it space vialls
` Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
# Exposed earth in unvented crawl spaces shall be covered with a Class I
Slihafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narro.'Ar cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
i spaces.
garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
i
air tight, IC rated, and sealed to the drywall.
I :1urnbing and wiring
Bait insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shovier/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
i
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
€
! HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
3/22/2018 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
D I S P LAY CAR O
ESTIMATED ENERGY PERFORMANCE,INDE)C* = 94
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if muippie family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windm-s" Description
a. J-Facto-; SgI, U=0.58
SHGC: SHGC=0.24
b. 1,t-Factor. SgI, U=0.65
SHGC: SHGC=0.21
c. J-Fz^tor: SgI, U=0,62
Sr{Gi C: SHGC=0.22
d. NIA
S`r1CC:
Area Wekjhted Average Overhang Depth:
Arer. 111,s:ghted Average SHGC:
5.807 SPRUCE DRIVE, FORT PIERCE, FL 34982
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1499.00-ft2
b. Frame - Wood, Adjacent
R=11.0
248.06 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
No
10. Ceiling Types
Insulation
Area
a. Roof Deck (Unvented)
R=20.0
1781.00 ft2
1781
b. N/A
R=
ft2
Area
c, N/A
R=
ft2
126.33 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
60.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
30.00 ft2
a. Central Unit
30.0
SEER:16.00
ft2
1.500 ft.
0.229
8. Rocr T )pas Insulation Area
a. S:a4-0n Grade Edge Insalation R=0.0 1781.00 ft2
r. R= ft2
c. 'A R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this '-ome before final inspection. Otherwise, a new EPL Display Card will be completed
baser or. installed Code compliant features.
Builder Signature:
. Address :r t evt Home:
Date:
City/FL Zip:
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 40 gallons
EF: 0.98
None
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
',,�chs,upport@energygauge.com or see the EnergyGauge web site at energygaUge.com for information and a list of
certi`red Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
I-L bel required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/2212018 9:49 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1