Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED BY FORM R405-2014 St Lucie Ccluniy FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: JAAR ENTERPRISES, LLC Builder Name: JC AND SONS HOME BUILDERS, INC. Street: 5807 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: 1801-0555 Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1747.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - EXt Insul, Exterior R=4.1 1499.00 ft2 b. Frame - Wood, Adjacent R=11.0 248.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bsdrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1781 0 sgfQ Insulation Area a. Roof Deck (Unvented) R=20.0 1781.00 ft2 6. Conditioned floor area above grade (ft2) 1781 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA . R= ft2 11. Ducts R ft2 7. Windows (216.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, U=0.58 126.33 ft2 SiiGC: SHGC=0.24 b. U-,=actor: Sgl, U=0,65 60.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 30.0 SEER:16.00 c. L-=actor: Sgl, U=0.62 30.00 ft2 S.HGC• SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: ,ores W eighled Average Overhang Depth: 1.500 ft. Area 1^; sighted Average SHGC: 0.229 14. Hot water systems 8, t=loc;�,. Tes (1781.0 sgfLInsulation Area a. Electric Cap: 40 gallons) a. S:Gc-On-Grade Edge Insulation R=0.0 1781.00 ft2 b. Conservation features EF:0.980 b. N,,A R= ft2 None R= ft2 15. Credits None Glass/Floor Area:' 0.121 Total Proposed Modified Loads: 59.32 PASS Total Baseline Loads: 63.10 I haret)y certify that the plans and specifications covered by Review of the plans and -f%E ST,gT this ara in ccn;pliarca with the Florida Energy specifications covered by this Rr 80�, Code. calculation indicates compliance ii�,�' �_�,.-',.����� PRF; with the Florida Energy Code. DATE: Before construction is completed this building will be Inspected for compliance with Section 553.908 * ° I hera_y ccut;fy that this building, as designed, Is in compliance Florida Statutes. 1� wit(^ the Florida Energy Code. G'OD W v O%A' R!fiGENT BUILDING OFFICIAL: DAY:=: - DATE: - Comol;arce �,aquires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certifled factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection checklist in accordance with R402.4.1.1 and starting July 1, 2017 ALL FiRO =CT5 require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1.2). RECEIVED APR 0 4 2018 File Copy ST. L'01O �Ob 3,2•o2J:o 7.-iy ASV �, I 9�ll �S - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: JAAR ENTERPRISES, LLC Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1781 Lot # Owner Name: Total Stories: 1 Block/SubDivision: ff of Units: 1 Worst Case: No PlatBook: Builder Name: JC AND SONS HOME BUILD Rotate Angle: 0 Street: 5807 SPRUCE DRIVE Permr:O`fi�-a: ST LUCIE COUNTY Cross Ventilation: No County. St. Lucie Jurisdiction: ST LUCIE COUNTY Whale House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34982 Nev:/Existing: New (From Plans) i Ceniment: CLIMATE Design Temp lnt Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5 % Winter Summer Degree Days Moisture Range r^~_ FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume i Entire House 1781 19328 SPACES N arna Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 2 188 1504 No 0 1 1 Yes Yes Yes `) 2 CLST 2 20 160 No 0 1 Yes Yes Yes 3 BATH 2 50 400 No 0 1 Yes Yes Yes CLST 3 20 160 No 0 1 Yes Yes Yes 5 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes 6 LIVING ROOM 300 4200 No 0 1 Yes Yes Yes 7 FOYER DINING RO 240 3360 No 0 1 Yes Yes Yes ii NOOK 130 1820 No 0 1 Yes Yes Yes 9 KITCHEN 130 s 1820 Yes 0 1 No Yes Yes -0 LAUNDRY 70 560 No 0 1 Yes Yes Yes -1 MASTER BEDROO 280 2520 No 0 1 1 Yes Yes Yes s 2 M WIC 54 432 No 0 1 No Yes Yes i -,3 NI BATH 109 872 No 0 1 Yes Yes Yes 1 HALL 21 168 No 0 1 No Yes Yes FLOORS. j K Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -Or, -grade Edge Insulation BEDROOM 2 27 ft 0 188 ftz 1 0 0 i 2 S!�b-Or.-Grsda Edge Insulation CLST 2 2 ft 0 i 20 ftz __� 1 0 0 _^ 2 S'sb-Cn-Grade Edge !nsulation BATH 2 5 ft 0 i 50 ft2 1 0 0 A S!ab-On-Grade Edge Insulation CLST 3 2 ft 0 20 f? ---- 1 0 0 3/2.2r2018 ::-49.Atv! EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R=Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation BEDROOM 3 26 ft 0 169 ft2 1 0 0 6 Slab -Or. -Grade Edge Insulation LIVING ROOM 15 ft 0 300 ft2 ____ 1 0 0 7 S!nb-On-Grade Edge Insulation FOYER DINING 15 ft 0 240 ft2 1 0 0 8 Slab -On -Grade Edge Insulation NOOK loft 0 130 ft2 _-- 1 0 0 9 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 130 ft2 ____ 1 0 0 10Slab-Or.-Grade Edge Insulation LAUNDRY 7 ft 0 70 11:2 __e 1 0 0 11Sleb-Or.-Grade Edge Insulation i MASTER BEDRO 35 ft 0 280 ft2 1 0 0 12Slah-On-Grade Edge Insulation M W IC 1 ft 0 54 ft2 1 0 0 f Ii 13S!ab-On-Grade Edge Insulation M BATH 9 ft 0 109 ft2 ____ 1 0 0 ! 14S!ab-On-Grade Edge Insulation HALL 1 ft 0 21 ft2 1 0 0 l ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area r Area Color Absor. Tested Tested Insul. (deg) ". Hip Composition shingles 1992 ft2 0 ft2 Medium 0.6 No 0.9 No 20 26.6 E ATTIC V it; Type Ventilation Vent Ratio (1 in) Area RBS IRCC - ? Full attic Unvented 0 1781 ft2 N N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type ? Under Attic (Unvented) BEDROOM 2 20 Blown 188 ft2 0.1 Wood 2 Under Attic (Unvented) CLST 2 20 Blown 20 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 2 20 Blown 50 ft2 0.1 Wood Ender Attic (Unvented) CLST 3 20 Blown 20 ft2 0.1 Wood Under Attic (Unvented) BEDROOM 3 20 Blown 169 ft2 0.1 Wood i 6 Under Attic (Unvented) LIVING ROOM 20 Blown 300 ft2 0.1 Wood 7 Under Attic (Unvented) FOYER DINING 20 Blown 240 ft2 0.1 Wood i 8 Under Attic (Unvented) NOOK 20 Blown 130 ft2 0.1 Wood I 9 Unoer Attic (Unvented) KITCHEN 20 Blown 130 ft2 0.1 Wood I UneerAttic (Unvented) LAUNDRY 20 Blown 70112 0.1 Wood 11 Under Attic (Unvented) MASTER BEDRO 20 Blown 260 ft2 0.1 Wood I 12 Unoer Attic (Unvented) MWIC 20 Blown 54ft2 0.1 Wood 13 Unoer Attic (Unvented) M BATH 20 Blown 109 ft2 0.1 Wood 14 Unoer Attic (Unvented) HALL 20 Blown 21 ft2 0.1 Wood 3/22/2018 5�:49 AM EnergyGaugel) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below t AI _ 1 S Exterior Concrete Block - Ext InstBEDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsSEDROOM 2 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 4 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ftz 0 0 0.6 0 _ 5 S Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 _ 6 E Exterior Concrete Block - Ext InsEEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.6 0 _ 8 W Exterior Concrete Block - Ext InsWIVING ROO 4.1 15 0 14 0 210.0 ft2 0 0 0.6 0 _ 9 E Exteror Concrete Block - Ext InstffOYER DINI 4.1 15 0 14 0 210.0 ft2 0 0 0.6 0 10 W Exterior Concrete Block - Ext Insul NOOK 4.1 10 0 14 0 140.0 ft2 0 0 0.6 0 11 E Exterior Concrete Block - Ext InsuILAUNDRY 4.1 7 0 8 0 56.0 ft2 0 0 0.6 0 12 N Exterior Concrete Block - Ext InsMASTER BE 4.1 17 0 9 0 153.0 ft2 0 0 0.6 0 ! 13 W Exterior Concrete Block - Ext InsLWASTER BE 4.1 18 0 9 0 162.0 ft2 0 0 0.6 0 _ 14 N Exterior Concrete Block - Ext Insul M BATH 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 _15 E Garage Frame - Wood M BATH 11 21 8 168.0 ft2 0 0 0.600000 0 .16 N Garage Frame - Wood FOYER DIN[ 11 10 8 80.0 ft2 0 0 0.600000 0 ' i WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area, Depth Separation Int Shade Screening i 1 W 2 Metal Low-E Single Yes 0.58 0.24 15.0 ft2 1 ft 6 in 1 ft 4 in None None 2 S 4 Metal Low-E Single Yes 0.58 0.24 6.0 ft2 1 ft6 in 1 ft 4 in None None i 3 E 6 Metal Low-E Single Yes 0.58 0.24 15.0 ft2 1 ft 6 in 1 ft4 in None None 4 W 2 Metal Low-E Single Yes 0.65 0.21 60.0 ft2 1 ft 6 in 1 ft4 in None None 5 E 9 Meta! Low-E Single Yes 0.58 0.24 30.0 ft2 1 ft 6 in 1 ft 4 in None None 6 E 9 Metai Low-E Single Yes 0.58 0.24 6.7 ft2 1 ft 6 in 1 ft 4 in None None j 7 E 9 Metal Low-E Single Yes 0.58 0.24 6.7 ft2 1 ft 6 in 1 ft4 in None None f E E s Metal Low E Single Yes 0.58 0.24 20.0 ft' 1 ft 6 in 1 ft 4 in None None ! 9 W 10 Metal Low-E Single Yes 0.62 0.22 30.0 ft2 1 ft 6 In 1 ft 41n None None 10 W 13 Meta! Low-E Single Yes 0.58 0.24 15.0 ft2 1 ft 6 in 1 ft 4 in None None 11 N 14 Me' ai Low-E Single Yes 0.58 0.24 12.0 ft2 1 ft 6 in 1 ft 4 In None None GARAGE i x Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 462 ft2 31 ft 8 ft 11 3l22, 2013 9:49 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 EI.A EgLA ACH ACH 50 1 Wnciehouse ProposedACH(50) .000483 2254.9 123.79 232.81 .3524 7 HEATING SYSTEM 77 # System Type Subtype Efficiency Capacity Block Ducts i 1 Electric Strip Heat i None COPA 27 kBtuthr 1 sys#1 COOLING SYSTEM System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 30 kBtulhr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM y/ 4 System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.98 40 gal 60.9 gal 120 deg None I SOLAR HOT WATER SYSTEM FSEC i Cerz # Company Name Collector System Model # Collector Model # Area Storage Volume FEF i None None ft2 DUCTS / -- Supply - — r Location R-Value Area — Return -- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Adic 6 140 ft2 Attic 14 ft2 Default Leakage Garage (Default) c(Default) c 1 1 " TEMPERATURES Prcgrmable Thermostat: N I Cmlino H Jan H Feb f Mar Heating Jan Feb [X� Mar Verrr-� Jan Feb[[fix)) Mar Ceiling Fans: Apr May [X] Jun [X� Jul Auge f Apr f May [ ] Jun E ] Jul AuSep E [X] Apr [ ]]] May [ ]Jun ]Jul Aug Se [X] Oct Nov Oct Nov Oct Nov Dec Dec Dec 312212018 9:49 AM EnergyGaugel) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 i FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ONC) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cec,'.rg tWEH1 AM 78 78 78 78 78 78 78 78 80 80 80 80 PP11 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 1 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/22/2018 9:49 AM EnergyGauge® USA - RaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name:. JAAR ENTERPRISES, LLC Builder Name: JC AND SONS HOME BUILDERS, INC. StrFe:: 5807 SPRUCE DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34982 Permit Number: 1801-0555 Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air carder and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains ;a continuous barrier. j Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Celiin•7/- sic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors .to unconditioned �r attic spaces shall be sealed. 4 # Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. I The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors i p The space between window/doorjambs and framing and skylights and P t Rim E ioists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and Grdlevered floors) of subfioor decking. The air barrier shall be installed at any exposed edge of insulation. Cra it space vialls ` Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. # Exposed earth in unvented crawl spaces shall be covered with a Class I Slihafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narro.'Ar cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity i spaces. garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be i air tight, IC rated, and sealed to the drywall. I :1urnbing and wiring Bait insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shovier/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air i barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. € ! HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/22/2018 9:50 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) D I S P LAY CAR O ESTIMATED ENERGY PERFORMANCE,INDE)C* = 94 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if muippie family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windm-s" Description a. J-Facto-; SgI, U=0.58 SHGC: SHGC=0.24 b. 1,t-Factor. SgI, U=0.65 SHGC: SHGC=0.21 c. J-Fz^tor: SgI, U=0,62 Sr{Gi C: SHGC=0.22 d. NIA S`r1CC: Area Wekjhted Average Overhang Depth: Arer. 111,s:ghted Average SHGC: 5.807 SPRUCE DRIVE, FORT PIERCE, FL 34982 New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1499.00-ft2 b. Frame - Wood, Adjacent R=11.0 248.06 ft2 1 c. N/A R= ft2 3 d. N/A R= ft2 No 10. Ceiling Types Insulation Area a. Roof Deck (Unvented) R=20.0 1781.00 ft2 1781 b. N/A R= ft2 Area c, N/A R= ft2 126.33 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Garage 6 140 60.00 ft2 12. Cooling systems kBtu/hr Efficiency 30.00 ft2 a. Central Unit 30.0 SEER:16.00 ft2 1.500 ft. 0.229 8. Rocr T )pas Insulation Area a. S:a4-0n Grade Edge Insalation R=0.0 1781.00 ft2 r. R= ft2 c. 'A R= ft2 13. Heating systems a. Electric Strip Heat 14. Hot water systems a Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this '-ome before final inspection. Otherwise, a new EPL Display Card will be completed baser or. installed Code compliant features. Builder Signature: . Address :r t evt Home: Date: City/FL Zip: kBtu/hr Efficiency 27.0 COP:1.00 Cap: 40 gallons EF: 0.98 None 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at ',,�chs,upport@energygauge.com or see the EnergyGauge web site at energygaUge.com for information and a list of certi`red Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. I-L bel required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/2212018 9:49 AM EnergyGaugeO USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1