Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOWS MULLIONS3/30/2018 Florida Building Code Online GCANNEU €3Y susiness t. e ' e s C v iF 4 ti. BCIS Home Log In I User Registration Hot Topics I Submit Surcharge l Stats & Facts I 'Publications FBC Staff BCIS Site Map Links Search Florida r�^��� a &�lsicru��t� 411 Product Approval USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail Fl- # FL15353-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Archived 0 Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz, PA 17030 (717)365-3300 Ext2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitfinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Mullions APES 0 4 2.018 ST. Lucie C!aunty, Permitting Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Luis R Lomas, PE PE-62514 National Accreditation and Management Institute 12/31/2018 Steven M. Urich, PE 91 Validation Checklist - Hardcopy Received FL15353 R3 COI FLCOI.pdf Standard AAMA 450 Year 2010 File Copy Product Approval Method Method 1 Option D https://floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWISXrzuhnEtBQs8TPfy5iOGhEwd"rixFT5Q%3d%3d 1/3 3/30/2018 Florida Building Code Online 11 Date Submitted Date Validated Date Pending FBC Approval Date Approved 10/16/2017 10/23/2017 10/26/2017 12/12/2017 FL # Model, Number or Name Description 15353.1 5764 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01448B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3_AE_512072B.pdf span: 104-1/4". Created by Independent Third Party: Yes 15353.2 5764 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01439B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE_5120638.pdf span: 83" Created by Independent Third Party: Yes 15353.3 5765 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II_08-01449B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PEPE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE_512073B.pdf span: 156-3/8" Created by Independent Third Party: Yes 15353.4 5765 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II_08-01440B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512064B.pdf span: 83". Created by Independent Third Party: Yes 15353.5 CM-18514 Vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II_08-01442B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84". Max mullion FL15353 R3 AE 512066B.pdf length - 83". Created by Independent Third Party: Yes 15353.6 CM-18520 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01451B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512075B.pdf span - 156-3/8" Created by Independent Third Party: Yes 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R3 II 08-01452B.pdf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PEPE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size - 52-1/8" x 84". Max mullion FL15353 R3 AE 512076B.pdf span - 104-1/4". Created by Independent Third Party: Yes 15353.8 I CM-18531 I Vertical Aluminum Mullion https:/tfloridabuilding.org/pr/pr app_ U.aspx?param=wGEVXQwtDgtHB572gvdWiSXrzuhnEtBQs8TPfy5iOGhEwdHrixFT5Q°/`3d%3d 2/3 A NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULUON VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W1 + W2 2 RE ONS pFSC oN CAM APPROWD REVISED INSTALLATION DETAILS 06/10/15 R.L. REVISED ANCHORING NOTES 06/07/17 R.L. ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8' MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 3/16" ELCO ULTRACON TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4' MINIMUM EMBEDMENT WITH 1' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 4. 3) FOR ANCHORING INTO METAL FRAMING USE #10 SMS OR SELF DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KSI/FU=52KSI OR ALUMINUM 6063-T5 FU=30KSI .048" THICK MINIMUM. 6) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12' MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. TABLE OF CONTENTS 7 NO. DESCRIPTION 1 NOTES 2 CONFIGURATIONS AND DP CHART 3 INSTALLATION DETAILS 4 COMPONENTS MI WINDOWS AND DOORS, LLC 650 WEST MARKET STREET GRATZ. PA 17030-0370 CM-18514 - VERTICAL MULLION 83" MULLION SPAN NOTES V.L IOB-01442 Oa NTS — 01/11/12 1-1 OF 4 L ROBERTO LOMAS RE 11V WDOOFORD RO LEMSVUL& NC27W3 434L98.0M dbmas@k m&Voo- SIGNED: 1011612017 E Nd' �i r. •v\ SF 9. '0E6 OF( *' Lu, ���'FS'cZ0R10P G�i'\� NA n�a\ Luis R. Lomas P.E. FL No.: 62514 A �C,B�rIDZHI 'B `DZHJ ;B `DHIWWWTWZ FRAME ( 'H7NOOW FRAM 'w,NDOW WINDOW HEIGHT WINDOW WINDOW . HEIGHT WINDOW HEIGHT (MULLION (MULLION (MULLIONSPA' 1 1 SPA' 1 1 SPA' 1 1 F_ 107 3/8' 107 3/8" W1 COMBINEDW2Hq F_ W7 COMBW2 83" J I J WINDOW J B� J WINDOW J FRAME /WINDO ` ! WINDO FRAME HEIGHT / HEIGHT WINDO1 WINDO (MULLION f (MULLION SPAN) SPAN) W2�073/-�COMBINE�� OM8DTH W2 107 3/8" COMBINED WIDTH "I�" !W7 W2 ! B3" FRAME J I I WINDOW J HEIGHT / /WNDQW `s1 1 1 W7 107 3/8" COMBINED WIDTH APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBEMULLED TOGETHER AS LONGAS COMBINED WIDTH DOES NOT EXCEED 107318'AS SHOWNHEREIN. R ONS DESCRIPTION MTE ARFROlED REVISED INSTALLATION DETAILS OB/10/15 R.L REVISED ANCHORING NOTES 06/07/17 1 R.L. Design pressure re6n9 (P.0 Units anchored Into wood Naming Mullion span (in) 18.13 Tributarywidth 25.50 136.00 1 4200 Qn 48.00 SZ13 25.00 120.0 120.0 1 120.9 1120.0 120.0 120.0 37.38 120.0 120.0 1120.01120.0 120.0 120.0 49.63 120.0 98.3 81.2 76.9 75.2 75.1 62.00 95.1 70.0 53.2 48.1 44.8 43.3 65.63 79.9 58.6 44.2 39.7 36.7 35.3 72.00 60.2 43.9 32.7 29.2 26.7 25.5 84.00 37.7 27.3 20.1 17.7 16.0 15.1 Design pressure rating with rebar option (pst) Units anchored Into wood IramIng Mullion span (In) 18.13 T 25.50 butary 136.00 width 4200 in 48.00 5213 25.00 120.0 120.0 120.0 1200. 120.0 120.0 37.38 120.0 1 20.0 120.0 120.0 120.0 120.0 49.63 120.0 98.3 1 81.2 76.9 75.2 75.1 6200 96.4 73.6 58A 53.7 50.7 49.4 65.63 90.2 68.6 53.9 49.3 46.3 44.8 7200 81.0 61.2 45.8 40.1 37.3 35.6 84.00 52.7 38.1 28.0 24.7 22.3 21.1 Design pressure rdtln8 (PstJ Units anchored Into masonry/comet. Mullion span (in) 18.13 Tributary 25.50 36.00 width (in) 4200 48.00 5213 25.00 120.0 120.0 120.0 12DO 120.0 37.38 120.0 120.0 120.0 120.0 120.0 49.63 120.0 109.2 90.2 85.4 83.5 6200 95.1 70.0 53.2 48.1 44.8 g25.5 65.63 79.9 58.6 44.2 39.7 36.7 7200 60.2 43.9 32.7 29.2 26.7 84.00 37.7 27.3 20.1 17.7 16.0 Design pressure rating with robar option (pso Units anchored Info masonry/concreto Mullion span (in) 18.13 Tributary 25.50 36.00 width 4200 In 48.00 15Z13 25.00 120.0 120.0 120.0 120.0 120.0 120.0 37.31 1 20.01 120.0 120.0 120.0 120.0 120.0 49.63 120.0 109.2 90.2 85.4 83.5 83.4 62.00 167.1 81.8 84.8 59.7 56.3 54.8 6S.63 100.2 76.2 59.9 54.8 51.3 49A 7200 84.2 61.4 45.8 40.8 37.3 35.6 84.00 52.7 38.1 28.0 24.7 22.3 21.1 LARGEAND SMALL MISSILE IMPACT, LEVEL D. WIND ZONE 3 DIMENSIONS IN CNARTARE FRAMEDIMENSIONS AND DO NOT INCLUDE FLANGE SIGNED: 10/16aO17 MI WINDOWS LLC OSTTR II�IIIC1� 650 WEST MARDKET ET GRATZ, PA 17030-0370 `v•�VOENSF••��' _ *•6 'k� CM-18514 - VERTICAL MULLION BRA MULLION SPAN CONFIGURATIONS AND DP CHARTS �p STATE OF ty� • '�5;:70R% V' G\� DRAWN: Dec No. REV V.L.08-0011442 8 �NA 11EaVV�\ R.ls Luis NoLomas P.E. .: 62514 aA C NTS 01/11/12 2 OF 4 L ROBERTO LOMAS RE 1432WOODFORDRDLEWSWLL&NC270M 434488-0609 dbmasgkbmmMp 1" MIN. EDGE DISTANCE MASONRY/CONCR ,. BY OTHERS °' •• 1 1/4' •° 'e •' MIN. EMBEDMENT _J II II I 1/4" ELCO ULTRACON TAPCON SECT5796 CLIP SECT CM-18514 MULLION SECT5796 CLIP #10 WOOD SCREW 1 3/8" MIN T WOOD FRAMING/ I 2X BUCK 1/2' MIN. I BY OTHERS EDGE DISTANCE VERTICAL CROSS SECTION MASONRY/CONCRETEAND WOOD FRAMING INSTAUARON .EMBEDMENT REVISIONS REV DESCRIPOON DATE APPROVED A REVISED INSTALLATION DETNLS 06/10/15 R.L. 8 REVISED ANCHORING NOTES 06/07/17 R.L. <6�> SECT5796 CUP _ _ #10 SMS OR —, SELF DRILLING I I I I SCREW METAL STRUCTURE 1 /2' MIN. BY OTHERS EDGE DISTANCE VERTICAL CROSS SECTION METAL INSTALLATION CLIP INSTALLATION SIGNED: 1011612017 MI 650DWESS MARDKETCOSTREET LLC \\`\J\5 iR IIlI0�i GRATZ. PA 17030-0370 ` v,•�VGENS�.gU+ CM-18514 — VERTICAL MULLION *• 0 5 83" MULLION SPAN INSTALLATION DETAILS7E oRArN: oxc No. RLv %'�s F<ORiOP' G��\� 6ruc NTS ogre 01/11/12 08 —32 OF 4 8 LROBERTOLOMASP.E Luis R. Lomas P.E. 1432 WOODFORD ROLEMSYRIE, NC2ND FL No.: 62514 43"88.060s Iftmo &b—pAFL - —{ 2 3,16" r 1 7/32° SECT CM-18514 MULLION ALUMINUM 6005-T5.125• THICK 3 3/4° 1" 3/8" 13/32" 2 1/32" 2 7/8" 27/3J 2- SECT5796 CLIP FOR CONCRETE INSTALLATION ALUMINUM 6063-75.125•THICK 2X 07/32° 1 13/16" RF-185-1 REBAR 16 GA (063 % GALVANIZED STEEL 3 3/4" 3/8• 13/32" 2 X 07/32" I 2 1/322 7/8" 27/31 2. T SECT5796 CLIP FOR CONCRETE INSTALLATION ALUMINUM 6063-75.125•THICK 3 3/4" --{I 2 3/16" 3/6• 27/32" 1 9/16" 2X 07/32° 1 9/16- 1 SECT5796 CLIP FOR WOOD FRAMING INSTALLATION ALUMINUM 6063-T5.125• THICK RMON9 DESCRIPRON M0: APPRWFD REVISED INSTALLATION DETAILS 06/10/15 R.L REVISED ANCHORING NOTES 06/07/17 R.L SIGNED: 1011612017 MI ANDOSOTREET LLC 650DWE5OWS 5 MARKET t..LL���''/' ENs�•�+ GRATZ, PA 17030-0370 ` �,••��G D 6 *= — �1a��frc�° CM-18514 — VERTICAL MULLION*• 83" MULLION SPAN COMPONENTS E OF �iOR\OP DMWN: M NO. REV 08 8 ,SLON1Ai110?\\\� Luis R. Lomas P.E. FL No.: 62514 swc NTS wre 01 /11/12 sNm 42 OF 4 L ROBERTO LOMASP.E 1432 WOODFORD RDLEMSVILLE.NC27023 d8 434 0 09 ,Ikma @kk asPamm .