Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE4 4. SCANNED BY FORM R405-2014 St Lucie County ;i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Depaitii *4 t"!6F 6M6'S'-s-and Professional Regulation - Rbsfd60fiWfP&Kffi6fice Method Project Name: Standard Pacific RB Fairfield Model Lot 9 Builder Name: Standard Pacific Homes Street: '3 0,30 /V L, J (2-AVC Permit Office: City, State, Zip: Port St. Lucie, FL , Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (4146.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3730.70 ft2 b. Frame - Wood, Adjacent R=11.0 416.13 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10. Ceiling Types (2651.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2651.00 ft2 6. Conditioned floor area above grade (ft2) 4086 b. N/A R= ft2 c. R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(558.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640 a. U-Factor: Dbl, U=0.60 363.14 ft2 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 420 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.40 175.23 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.31 a. Central Unit 44.5 SEER:14.00 b. Central Unit 30.0 SEER:14.00 c. U-Factor: Dbl, U=0.77 20.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 45.0 HSPF:8.20 SHGC: b. Electric Heat Pump 29.6 HSPF:8.20 Area Weighted Average Overhang Depth: 3.077 ft. Area Weighted Average SHGC: 0.307 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2651.0 sqft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 2651.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.137 Total Proposed Modified Loads: 107.53 PASS Total Baseline Loads: 108.40 I hereby certify that the plans and specifications covered by Review of the plans and ST,q?, this calculation are in compliance with the Florida Ener�q�r specifications covered by this It 1�� _ 0�, iif1 •c Digitally sign y Chris Wildroudt Code. Chris DN: cn=Chris Wildroudt, c=US, calculation indicates compliance ? a �� '�o=Engineered Air, LLC, ou=New Sales and with the Florida Energy Code. it /lril:'� , •:;.r'``;:.�'P„ O PREPARED BY: If ,censtruccion Before construction is completed building be inspected for DATE: eou=-�h' this will `°y COm compliance with Section 553.908 t * Date: 2015.09.0916:25:01 -04'00 1 hereby certify that this building, as designed, is in compliances Florida Statutes. c� with the Florida Energy Code. OOD {yE� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 9/9/2015 4:23 PM I EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 CEILING # •; „ Ceiliq T pe . ',Space R-Value' a . y Framing Frac Truss Type 1 Under Attic (Vented) AC 1� First Floor - 30 1119 ft2 0.11 Wood 2 Under Attic (Vented) AC 2 Second Flo 30 1532 ft2 0.11 Wood WALLS Adjacent CavRXaity Width Height Sheathing Framing Solar Belo w # nrnt In Space Wall Type 1 E Exterior Concrete Block - Int•Ins9C 1 First Flo 4.1 23 0 10.67 0 245.4 ft2 0.4 0 0.4 0 2 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 50 0 10.67 0 533.5 ft2 0.4 0 0.4 0 3 W Exterior Concrete Block - Int Ins&C 1 First Flo 4.1 46 0 10.67 0 490.8 ft2 0.4 0 0.4 0 4 W Exterior Concrete Block - Int InshIC 1 First Flo 4.1 19 0 10.67 0 202.7 ft2 0.4 0 0.4 0 5 S Exterior Concrete Block - Int Ins9C 1 First Flo 4.1 28 0 10.67 0 298.8 ft2 0.4 0 0.4 0 6 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7 ft2 0.4 0 0.4 0 7 E Garage Frame - Wood AC 1 First Flo 11 33 0 10.67 0 352.1 ft2 0.4 0.4 0 8 S Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.0 ft2 0.4 0.4 0 9 E Exterior Concrete Block - Int InsiNC 1 First Flo 4.1 8 0 10.67 0 85.4 ft2 0.4 0 0.4 0 10 E Exterior Concrete Block - Int Ins6IC 2 Second 4.1 52 0 9.33 0 485.2 ft2 0.4 0 0.4 0 11 S Exterior Concrete Block - Int InsAC 2 Second 4.1 41 0 9.33 0 382.5 ft2 0.4 0 0.4 0 12 W Exterior Concrete Block - Int Ins9C 2 Second 4.1 52 0 9.33 0 485.2 ft2 0.4 0 0.4 0 13 N Exterior Concrete Block - Int Ins9C 2 Second 4.1 41 0 9.33 0 382.5 ft2 0.4 0 0.4 , 0 1 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Wood AC 1 First Flo None .39 2.7 8 21.4 ft2 2 E Wood AC 1 First Flo None .39 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.6 0.31 32.3 ft2 2 ft 0 in 12 ft 0 in None None 2 E 1 Metal Low-E Double Yes 0.4 0.31 12.3 ft2 2 ft 0 in 10 ft 0 in None None 3 N 2 Metal Low-E Double Yes 0.6 0.31 22.7 ft2 2 ft 0 in 12 ft 0 in None None 4 N 2 Metal Low-E Double Yes 0.4 0.31 23.2 ft2 2 ft 0 in 12 ft 0 in None None 5 N 2 Metal Low-E Double Yes 0.4 0.31 8.0 ft2 2 ft 0 in 2 ft 0 in None None 6 W 3 Metal Low-E Double Yes 0.6 0.31 48.5 ft2 2 ft 0 in 12 ft 0 in None None 7 W 3 Metal Low-E Double Yes 0.6 0.31 27.3 ft2 2 ft 0 in 2 ft 0 in None None 8 W 3 Metal Low-E Double Yes 0.4 0.31 28.1 ft2 2 ft 0 in 2 ft 0 in None None 9 W 3 Metal Low-E Double Yes 0.77 0.22 20.0 ft2 2 ft 0 in 2 ft 0 in None None 10 W 3 Metal Low-E Double Yes 0.4 0.31 9.2 ft2 2 ft 0 in 2 ft 0 in None None 11 W 4 Metal Low-E Double Yes 0.6 0.31 39.0 ft2 10 ft 0 in 2 ft 0 in None None 12 W 4 Metal Low-E Double Yes 0.4 0.31 28.1 ft2 10 ft 0 in 2 ft 0 in None None 13 S 5 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 2 ft 0 in 2 ft 0 in None None 14 S 6 Metal Low-E Double Yes 0.6 0.31 16.2 ft2 6 ft 0 in 2 ft 0 in None None 15 E 10 Metal Low-E Double Yes 0.4 0.31 8.0 ft2 2 ft 0 in 2 ft 0 in None None 9/9/2015 4:23 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 .FORM R405-2014 i WINDOWS Orientation shown is the entered, Proposed orientation. V # :Wall Ornt ID Frame Panes r NFRC a •,�� �. ,.;. __•�.. , .. Overhang •. U-Factor SHGC Area Depth Separation Int Shade Screening 16 17 18 19 20 21 22 23 E 10 Metal S 11 Metal S 11 Metal W 12 Metal W 12 Metal N 13 Metal N 13 Metal N 13 Metal Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.6 0.31 58.5 ft2 2 ft 0 in 2 ft 0 in 0.4 0.31 4.0 ft2 2 ft 0 in 2 ft 0 in 0.6 0.31 14.6 ft2 2 ft 0 in 2 ft 0 in 0.4 0.31 44.3 ft2 2 ft 0 in 2 ft 0 in 0.6 0.31 58.5 ft2 2 ft 0 in 2 ft 0 in 0.4 0.31 6.0 ft2 2 ft 0 in 2 ft 0 in 0.6 0.31 29.3 ft2 2 ft 0 in 2 ft 0 in 0.4 0.31 4.0 ft2 2 ft 0 in 2 ft 0 in None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 600 ft2 600 ft2 102 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 IELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000323 3464.9 190.22 357.73 .2905 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump None Electric Heat Pump None HSPF:8.2 45 kBtu/hr HSPF:8.2 29.6 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Central Unit Split Split SEER: 14 44.5 kBtu/hr 1600 elm SEER: 14 30 kBtu/hr 1000 cfm 0.75 1 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 50 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 9/9/2015 4:23 PM., - • Energy.Gauge® USA - FlaRes2014 Section' R405.4.1 Compliant Software Page 4 of 5 -FORM R405-2014 PROJECT Title: •StarLdar 4Aac�ifip:RB�Fairfielcl, Bedrooms: 5 „ , ,.rr�c} rest Type: Lot Information Building Type: User Conditioned Area: 4086 Lot #• 9 Owner: Standard Pacific Homes Total Stories: 2 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 2579 27517.9 2 Block2 1507 14060.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 First Floor 2579 27517.9 No 7 2 1 Yes Yes Yes 2 AC 2 Second Floor 1507 14060.3 No 3 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 226 ft 0 2651 ft2 ___ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 2872 ft2 0 ft2 Medium 0.6 No 0.9 No 30 22.6 ATTIC V # Type Ventilation Vent Ratio•(1 in) Area RBS IRCC 1 Full attic Vented 150 2651 ft2 N N 9/9/2015 4:23 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page'2 of 5 FORM R405-2014 DUCTS y --- Supply — -- Return --- Type Air Handler CFM 25 TOT CFM25 OUT QN RLF HVAC# , Heat MI # Location R-Value Area Location Area eakage 1 Attic 6 640 ftz Attic 102 ftZ Default Leakage AC 1 First F (Default) (Default) 1 1 2 Attic 6 420`ft' Attic 96 ftZ Default Leakage AC 2 Secon (Default) (Default) 2 2 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin [[ ]]Jan Heating [X] Jan [[ jj Feb [X] Feb Mar Mar [ j j A r Apr f May May Jun Jul rl Jun rl Jul AuSep rl Au Se Oct Oct Nov Nov Dec Dec Ventin [[ ]] Jan [[ ]] Feb X Mar X [X] _] A r [ Ma Jun Jul Aug Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I 9/9/2015 4:23 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software I, Page 5 of 51 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) D19PLAY CARP „..., : ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. Port St. Lucie, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3730.70 ft2 b. Frame - Wood, Adjacent R=11.0 416.13 ft2 3. Number of units, if multiple family 1 G. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2651.00 ft2 6. Conditioned floor area (ft2) 4086 b. N/A R= ft2 7. Windows** Description Area c. R= ft2 a. U-Factor: Dbl, U=0.60 363.14 ft2 11. Duuctct s a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor R ft 6 640 SHGC: SHGC=0.31 b. Sup: Attic, Ret: Attic, AH: AC 2 Second Floor 6 420 b. U-Factor: Dbl, U=0.40 175.23 ft2 SHGC: SHGC=0.31 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.77 20.00 ft2 a. Central Unit 44.5 SEER:14.00 SHGC: SHGC=0.22 b. Central Unit 30.0 SEER:14.00 d. U Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 45.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.077 ft. b. Electric Heat Pump 29.6 HSPF:8.20 Area Weighted Average SHGC: 0.307 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2651.00 ft2EF: a. Electric 0.92 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: �jp�8 ;uc,J (ZROC.,1%ft L, City/FL Zip: x *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. • 9/9/2015 4:24 PM 3- EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software IPage 1 of 1