HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVALi
BY
St Lucie County
APPLICATION #:AP12149.54
STATE OF FLORIDA PERMIT #:56-SF-1645927
!" M1 DEPARTMENT OF HEALTH DOCUMENT # : F11079187
Q• ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:12/03/20'15
•�°" FEE PAID:400.00
RECEIPT #:56-PID-28.5.5434
APPLICANT: Standard Pacific of Florida GP; Inc
AGENT: The Milcor Group, Inc.
PROPERTY ADDRESS: 3030 NW Radcliffe Way Palm City, FL 34990
LOT: 9
BLOCK:
SUBDIVISION:
Riverbend ID#: 4425-703-0014-000-6
CHECKED (X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE'OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [1] 900.00 [2] 750.00
[ ]
[27] SURFACE WATER FT
[ ] [021
TANK MATERIAL Concrete
[ ]
[28] DITCHES FT
[ ] [03]
OUTLET DEVICE
[ ]
[29] PRIVATE WELLS FT
[ ] [04]
MULTI -CHAMBERED CL2�2 N ]
[ ]
[301 PUBLIC WELLS FT
[ ] [Ob]
OUTLET FILTER Polylok.PL-68
[ ]
[31] IRRIGATION WELLS FT
[ ] [06]
LEGEND 1. 28-015-04SC3 2. 28-015-01SC3
[ ]
[321 POTABLE WATER 50 FT
[ ] [071
WATERTIGHT
[ ]
[33] BUILDING FOUNDATIONS 5 FT
[ ] [08]
LEVEL
[ ]
[34] PROPERTY LINES 12 FT
[ ] [09]
DEPTH TO LID
[ ]
[35] OTHER FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [101
AREA [1] 656.66 [21 SQFT
[ ]
[36] DRAINFIELD COVER
[ ] [11]
DISTRIBUTION BOX HEADER X
[ ]
[37] SHOULDERS
[ ] [121
NUMBER OF DRA--INLINES 1. 4.00 2,
[ ]
[38] SLOPES
[ ] [131
DRAINLENE SEPARATION
[ ]
1391 STABILIZATION 10/19/2016
] [14]
DRAINLENE SLOPE
[ ] [151
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [16]
ELEVATION [ AaovE / BELOW ]BM 17,00
[ ]
[401 UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION
[ ]
[411 STORMWATER,RUNOFF
[ ] [18]
DOSING PUMPS 1.00
[ ]
[42] ALARMS
[ ] [19]
AGGREGATE SIZE
[ ]
[43] MAINTENANCE AGREEMENT
[ ] [201
AGGREGATE EXCESSIVE FINES
[ ]
[441 BUILDING AREA
[ ] [21]
AGGREGATE DEPTH
[ ]
[45] LOCATION CONFORMS WITH SITE PLAN
[ ]
[4,61 FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ ]
[47] CONTRACTOR Brian. Davis.(Brian Davis Sep
[ ] 1221
FILL AMOUNT
( ]
[481 OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [231
FILL TEXTURE
[ ] [24]
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED
[ ]
[491 TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL
[ 1
(50] TANK CRUSHED & FILLED
Comments: Comments are on page 2.
/
St.. Lucie CHD DATE: 08/16/2016
CONSTRUCTION
[ APPROVED DISAPPROVED ] ° Environmental SpeTIan
J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM
C APPROVED / 'DISAPPROVED ];,
St. Lucie CHD DATE: 10120/2016
Environmental. pe list
Bran
ngram. E R MESA H E LTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (obsoletes all. previous editions which may not be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Databaso •v 1.0.1 AP1214954
EID;1645927
RECEIVED OCT-212016
e�
DEPARTMENT OF
STATE OF FLORIDA
F HEALTH
'trey ONSITE :SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Gommen
Comments
APPLICATION #':/4P1214.964
PERMIT #:56-SF-1'645927
DOCUMENT #': F11079187
"DATE PAID.,12103/2015
FEE, PAID:400.00
RECEIPT; #:56-PID-2855434
The system'is sized4or 5 bedrooms with a maximum occupancy of 1:0 persons (2 per bedroom), for a total estimated`flow of
520 gpd 483gai DT installed: after 2 STs. 70-143-54SC4. 2x14+2x15' chambers=58 chambers.
No violations,. system ok to cover. Contractor notified onsite.
Needs final inspection for mound system.
Final system approved. Contractor and building department emalled final approval.
DH 4016, 08/06 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v1.0.1 A01214964 EID1646927