Loading...
HomeMy WebLinkAboutPERMIT WORKSHEETx C•T% BY PERR7i1Y �1�fl�BR �...... ". ` N`=. `:' ......«.:<.. . �\\tip : :h\•\.`.�.v.s.l ,' •'i •�4 + 4 ram• InstallerLicense# Address of home j-7Gt. being installed PERMIT WORK�sHEET I page 1 of 2 New Home �sed Home ❑ Home installed to the Manufacturer's Installation Manual Home is installed in accordance with Rule 15-0 �7 7 7J Single wide ❑ Wind Zone II Wind Zone III Manufacturer xT ,6 �S`C_i Length x width �i'(Y . �ouble wide rq-`� Installation Decal 4 NOTF_ ' 'It home Is a single wide fill out one half of the blocking plan WrelpleVOuad * ❑ Serial If home is a triple or quad wide sketch In temalnder of home v v I understand Lateral Arm Systems cannot be used on any home (new o ig ZIP Mare the sidewall ties exceed 5 ft 4 in: `r"i' � - Installet's initials o �.oaci Footer wring sloe Typical pier spacing $` %pacity (sq in) lateral 2' m 1000 S Sfiow locations of Longitudinal and Lateral System 1 0.0 s lerpltudlnal (use dark lines to show these locations) ca 000 s 2500 pst m :.qnnn ne marriage wall pleri within Y' of and of home PIER SPACING TABLE FOR USED HOMES 16' x 16' 18 1/2' x is 112 20' x 20' 1 22' x 22• 24' X 24' 26' x 26' (266) 1 (342) 1 (400) 1 (484)' 1 (576)' 1 (576) ' interpolated from Rule i5C-1 pier spaclrip table. PIER PAD SIZE$ I-beam pier pad size /,V�[ l� Perimeter pier pad size C ea ad sizes / % K2 the mfg.) �cn5�m raw the approximate locations of marriage C �,Ibol o! show thetor pie sreater. Use this tsc m -c Co _j > i i�iage wall openings greater than 4 foot §n jEgLer pad sizes below. POPULAR PAD SIZES Had ize n. 16 x1 x1 1x1.5 16 x 22.5 1•x-974- 13 1/4 X X x 25 717- 17 112x 4x 24 26x26 ANc ,rE__-�V- ter_ g Pier pad -.size RS � X3 -mq MIV �M� a / 2 � Oft 5 fi Z; °D FRAME TIES =si,= ZN�'+ �`?i� within 2' of end of home spaced at 5' 4" oc TIEDOWN COMPONENTS 1 OTHER TIES Number L.ongltudlnal Stabjllzlr;gDey,Le (LSD) Manufacturer ;L LL �i .�� IV-4ib Longltud/na1 Sidewali itU'dinal Stabll#z ng De v wl Lateral Arms 4; a iaggswau Manufacturer__ i0 _.,.Shearwall N PERMIT NUMBER ... .. �., POCKET PENETROMETER TEST The pbcket penetrometer tests are rounded down to psf or check hereto declare 1000 lb. soil without testing. X X X POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the.footer. S. Using 500 lb, increments, take the lowest reading and round down to that increment. X X .X TORQUE PROBE TEST The results of the torque probe test isInch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors, Note: A state approved lateral arm system is being used and 4 ft. .anchors are allowed at -the sidewall locations, i understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275•or less and w ere the mobile home manufacturer may requires anchors with 40 ing capacity. Installer's initials ALL TESTS MUST7 PERFORIAED BY A Lt ENNSED INSTALLER Installer Name Gat /Ge G�-1 Date Tested Electrical 1onnect electrical conductors between multi -wide units, but not to the main power ource. This•ingludes the bonding wire between mutt -wide units. Pg. Plumbina ;onnect all sewer drains to an existing sewer tap or septic tank Pg. onnect all potable water supply piping to an existing water meter, water tap, or other dependent water supply systems, Pg, PERMIT WORKSHEET ( Page 2 of 2 1 I Site Preparation Debris and organic material removed Water drainage: Natural Swale Pad Other Fastening multi wide units �s Floor. Type Fastener.ZC- • Length: Spacing: l Walls: Type Fastener: Length: Spacing: Roof: Type Fastener. Length: Spacing: For.used homes a n. 30 gauge, 8" wide, galvanized metal 'strip will be centered over the peak of the -roof and fastened with gals. roofing nails at 2" on center on both sides of the centerline, Gasket (w=therprooting requ)rcn*nq I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I u erstand a strip of tape will not serve as a gasket. Installer's initials Type gasketInstalled: Pg. Between Floors Yes v Between Walls Yes Bottom of ridgebeam Yes Weatherproofing The bottomboard will be repaired and/or taped. Yes . Pq. Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney Installed so as not to allow intrusion of rain water. Yes ecus Skirting to be installed. Yesy No Dryer vent installed outside of skirting. Yes _�N/A Range_downflow vent installed' outside of skirtin N/A Drain lines supported at 4 foot intervals Electrical crossovers protected. -`Yes Other: Installer verifies all information given with this permit Worksheet is accurate and true based on the mannfar_turPr's installation instructions and or Rule 15C-1 & 2 Installer /�7 e