Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE:y FORM R405-2014 SCANNED BY St Lucie County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performpag lAethod Project Name: LEONHARD RESIDENCE Builder Name: HARRY BLUE BUILDER b-bti Mp� 0 Street: 9710 RUSSOS ROAD Permit Office: ST LUCIE COUNTY Ga ogo City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: 1801-0616 `,%V; Owner: ERIC LEONHARD Jurisdiction: ST LUCIE COUNTY St•�'� Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2182.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 2182.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (2463.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2463.00 ft2 6. Conditioned floor area above grade (ft2) 2463 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(222.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: AHU 6 150 a. U-Factor: Sgl, U=0.58 150.00 ft2 SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.32 72.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.237 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2463.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2463.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.090 Total Proposed Modified Loads: 70.93 PASS Total Baseline Loads: 79.27 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 04,tIlE,S7'9?c� Code. calculation indicates compliance ``'a)S• with the Florida Energy Code. �' rNlli'9;: %'s522`? „ PREPARED BY: ` �'.�d Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 x �I' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Ener y Code. COb,W. B. OWNER/AGENT- BUILDING OFFICIAL: 'DATE: DATE: .s - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 ALL PROJECTS require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1"2). 3/16/2018 10:35 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software File C op crone oenCZ e)n!n PROJECT Title: LEONHARD RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2463 Lot # Owner Name: ERIC LEONHARD Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HARRY BLUE BUILDER Rotate Angle: 0 Street: 9710 RUSSOS ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2463 25508 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 351 3861 No 0 1 1 Yes Yes Yes 2 CABANA 42 420 No 0 1 Yes Yes Yes 3 WIC 36 360 No 0 1 No Yes Yes 4 M W IC 1 35 350 No 0 1 Yes Yes Yes 5 M WIC 2 42 420 No 0 1 No Yes Yes 6 LAUNDRY 61 610 No 0 1 No Yes Yes 7 HALL 24 240 No 0 1 No Yes Yes 8 MASTER BATH 144 1440 No 0 1 Yes Yes Yes 9 OFFICE 140 1400 No 1 1 Yes Yes Yes 10 OFFICE CLST 16 160 No 0 1 Yes Yes Yes 11 FOYER 91 910 No 0 1 Yes Yes Yes 12 CLST 2 24 240 No 0 1 No Yes Yes 13 BEDROOM 2 204 2040 No 0 1 1 Yes Yes Yes 14 BATH 2 88 880 No 0 1 Yes Yes Yes 15 BEDROOM 3 204 2040 No 0 1 1 Yes Yes Yes 16 CLST 3 24 240 No 0 1 Yes Yes Yes 17 ' HALLWAY 64 640 No 0 1 No Yes Yes 18 KITCHEN 337 3370 Yes 0 1 Yes Yes Yes 19 GREAT ROOM 527 5797 No 0 1 Yes Yes Yes V 20 AHU 9 90 No 0 1 No Yes Yes 3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood' Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 36 ft 0 351 ftZ __-_ 1 0 0 2 Slab -On -Grade Edge Insulation CABANA 6 ft 0 42 ftZ ---- 1 0 0 3 Slab -On -Grade Edge Insulation WIC 1 ft 0 36 ftZ 1 0 0 4 Slab -On -Grade Edge Insulation M W IC 1 7 ft 0 35 ftZ ___- 1 0 0 5 Slab -On -Grade Edge Insulation M W IC 2 1 ft 0 42 ftZ ___- 1 0 0 6 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 61 ftZ ___- 1 0 0 7 Slab -On -Grade Edge Insulation HALL 1 ft 0 24 ftZ _--_ 1 0 0 8 Slab -On -Grade Edge Insulation MASTER BATH 24 ft 0 144 ftZ --__ 1 0 0 9 Slab -On -Grade Edge Insulation OFFICE lift 0 140 ftZ ____ 1 0 0 10SIab-On-Grade Edge Insulation OFFICE CLST 2 ft 0 16 ftZ ____ 1 0 0 11SIab-On-Grade Edge Insulation FOYER 7ft 0 91 ftZ __-- 1 0 0 12SIab-On-Grade Edge Insulation CLST 2 1 ft 0 24 ftZ __-- 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 2 17 ft 0 204 ftZ --__ 1 0 0 14SIab-On-Grade Edge Insulation BATH 2 8 ft 0 88 ftZ ---_ 1 0 0 15SIab-On-Grade Edge Insulation BEDROOM 3 29 ft 0 204 ft' ---- 1 0 0 16SIab-On-Grade Edge Insulation CLST 3 2 ft 0 24 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 64 ftZ ____ 1 0 0 18SIab-On-Grade Edge Insulation KITCHEN 15 ft 0 337 ftZ __-- 1 0 0 19SIab-On-Grade Edge Insulation GREAT ROOM 46 ft 0 527 ftZ __-- 1 0 0 20SIab-On-Grade Edge Insulation AHU 1 ft 0 9 ftZ ____ 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2668 ftZ 0 ftZ Light 0.6 No 0.9 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2463 ft- N N 3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 20 Blown 351 ft2 0.1 Wood 2 Under Attic (Unvented) CABANA 20 Blown 42 ft2 0.1 Wood 3 Under Attic (Unvented) WIC 20 Blown 36 ft2 0.1 Wood 4 Under Attic (Unvented) M WIC 1 20 Blown 35 ft2 0.1 Wood 5 Under Attic (Unvented) M W IC 2 20 Blown 42 ft2 0.1 Wood 6 Under Attic (U nvented) LAUNDRY 20 Blown 61ft2 0.1 Wood 7 Under Attic (Unvented) HALL 20 Blown 24 ft2 0.1 Wood 8 Under Attic (Unvented) MASTER BATH 20 Blown 144 ft2 0.1 Wood 9 Under Attic (Unvented) OFFICE 20 Blown 140 ft2 0.1 Wood 10 Under Attic (Unvented) OFFICE CLST 20 Blown 16 ft2 0.1 Wood 11 Under Attic (Unvented) FOYER 20 Blown 91ft2 0.1 Wood 12 Under Attic (Unvented) CLST 2 20 Blown 24 ft2 0.1 Wood 13 Under Attic (Unvented) BEDROOM 2 20 Blown 204 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 2 20 Blown 88 ft2 0.1 Wood 15 Under Attic (Unvented) BEDROOM 3 20 Blown 204 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 3 20 Blown 24 ft2 0.1 Wood 17 Under Attic (U nvented) HALLWAY 20 Blown 64ft2 0.1 Wood 18 Under Attic (Unvented) KITCHEN 20 Blown 337 ft2 0.1 Wood 19 Under Attic (Unvented) GREAT ROOM 20 Blown 527 ft2 0.1 Wood 20 Under Attic (Unvented) AHU 20 Blown 9 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 0 _ 1 N Exterior Concrete Block - Ext InsLMASTER BE 4.1 19 0 11 0 209.0 ft2 0 0 0.6 0 _ 2 W Exterior Concrete Block - Ext InsiWIASTER BE 4.1 17 0 11 0 187.0 ft2 0 0 0.6 0 • _ 3 N Exterior Concrete Block - Ext Insul CABANA 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 _ 4 W Exterior Concrete Block - Ext Insul M W IC 1 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 5 S Exterior Concrete Block - Ext InsLMASTER BA 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 6 W Exterior Concrete Block - Ext InstWIASTER BA 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 7 S Exterior Concrete Block - Ext Insul OFFICE 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 _ 8 S Exterior Concrete Block - Ext InsdDFFICE CLS 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 9 S Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext Insi9EDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 _ 11 W Exterior Concrete Block - Ext InstSEDROOM 2 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 12 S Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 13 E Exterior Concrete Block - Ext InsSEDROOM 3 4.1 17 0 10 0 170.0 ft2 0 0 0.6 0 _ 14 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 •_ 15 E Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 16 N Exterior Concrete Block - Ext Insul KITCHEN 4.1 15 0 10 0 150.0 ft2 0 0 0.6 0 _ 17 N Exterior Concrete Block - Ext InstBREAT ROO 4.1 24 0 11 0 264.0 ft2 0 0 0.6 0 18 E Exterior Concrete Block - Ext InstOREAT ROO 4.1 22 0 11 0 242.0 ft2 0 0 0.6 0 3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 1--, Ct-%MRA onnG OnIA DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 N S Insulated Insulated CABANA FOYER None .27 None .27 2 3 8 8 16 ft2 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Area Overhang Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 9 N 1 Metal W 2 Metal S 5 Metal S 7 Metal S 10 Metal S 14 Metal N 16 Metal N 17 Metal N 17 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes Yes 0.32 0.23 24.0 ft2 0.58 0.24 20.0 ft2 0.58 0.24 16.0 ft2 0.58 0.24 15.0 ft2 0.58 0.24 30.0 ft2 0.58 0.24 30.0 ft2 0.58 0.24 9.0 ft2 0.58 0.24 30.0 ft2 0.32 0.23 48.0 ft2 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft 4 in 2 ft 0 in 1 ft4 in None None None None None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000461 2975.9 163.37 307.25 .3363 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 / Cnone onnXZ'3n4n DUCTS -- Supply -- — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ftz Attic 15 ft2 Default Leakage AHU (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling[[ ]] Jan Heatin[X] Jan [ ] Feb Feb [[ ]] Mar [X] Mar f Apr Apr f ] May ] May 4 X] Jun ] Jun [X] Jul ] Jul [X] Aug [ ] Aug [X] Sep [ ] Sep [ j [ ] Oct Oct [ ] Nov [X] Nov Dec Dec Venting[[ ]]Jan 4X] ]Feb [[XX]] Mar [X] Apr (] May [ ]Jun E ]Jul [ ] Aug [ ] Se p [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH) AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 3/16/2018 10:35 AM EnergyGaugeB USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 / FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LEONHARD RESIDENCE Builder Name: HARRY BLUE BUILDER Street: 9710 RUSSOS ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: 1801-0616 Owner: ERIC LEONHARD Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to.the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/16/2018 10:35 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. r 9710 RUSSOS ROAD, FORT PIERCE, FL, 34951 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Sgl, U=0.58 SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.32 SHGC: SHGC=0.23 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) Single-family 1 3 No 2463 Area 150.00 ft2 72.00 ft2 ft2 ft2 2.000 ft. 0.237 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2463.00 ft2 b. N/A R= ft2 c. N/A R= ft2 9. Wall Types a. Concrete Block - Ext Insul, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Roof Deck (Unvented) b. N/A c. N/A 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:_ Date: ty*4T Address of New Hom=�� �p, City/FL Zip: Insulation R=4.1 R= R= R= Insulation R=20.0 R= R= Area 2182.00 ft2 ft2 ft2 ft2 Area 2463.00 ft2 ft2 ft2 R ft2 6 150 kBtu/hr Efficiency 42.0 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 Cap: 40 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 DOIMP Customer Name: Address: Phone: Fax: Customer Information: Quote Date: 3/8/2018 Manning Building Supplies 3315 Oleander Ave Ft. Pierce, FL 34982 Project Name: LEONHARD RESIDENCE Quote Name: HARRY BLUE BLDRS Quote Number: 2034205 Order Date: Quote Not Ordered PO Number: Comments: RO size for Flange is for standard 1x buck with precast sill. Please contact your supplier for other Flange opening RO's. Does not apply to Western Region. I'EM & SIZES LOCATION / TAG PRODUCT DESCRIPTION UNIT PRICE / EXTENDED PRI Line ttem: 10d-1 None Assigned Quantity: 1 RO Size: 53.875" X 50.625" Unit Size: 52.125" X 49.625" 185 Single Huna - Vent - F34 "* PRODUCT — Row 1 185 Single Hung - Vent -1 Units - 52.125W x 49.625H **' DIMENSIONS *** 52.125W x 49.625H **" FRAME **' South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color - White *** GLASS Glazing Type - Insulated, Glass Tint - Clear, Low-E 366 and Obscure, Obscure Placement - Full, Argon Gas, Tempered Location - Full *** SCREEN * Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - Yes *'* NFRC *** Series 185::SingleHung, U-Factor: a SHGC::0.24, VT::0.52 *** Performance "" Series 185::SingleHung, Calculated Positive DP Rating::60.15, Calculated Negative DP Rabng::60.15, DP Rule ID::1851MPACT SH, Rating Type::DesignPressure, Structural Rating::R-PG60, Water Rating::9.19, FL ID::17499, STC Rating::33 Unit Price: $595.23 Extended Price: $595.23 ITEM S SIZES LOCATION) TAG -PRODUCT DESCRIPTION UNIT PRICE /:EXTENDED PRICE Line Item: 20D-1 None Assigned **'PRODUCT` Quantity: 7 RO Size: 37.75" X 63" Unit Size: 36" X 62" 35 Row 1 185 Single Hung - Vent -1 Units - 36W x 62H **' DIMENSIONS 36W x 62H *"* FRAME South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color - White "*' GLASS'"* Glazing Type - Insulated, Glass Tint - Clear, Low-E 366, Argon Gas *** SCREEN **' Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed Separately - Yes * " NFRC '** Series 185::SingleHung U-Factor.:0.58, HGC:.0.24, VT::0.52 *** Performance " Series 185::SingleHung, Calculated Positive DP Rating::60.15, Calculated Negative DP Rating::60.15, DP Rule ID::1851MPACT SH, Rating Type;:DesignPressure, Structural Rating::R-PG60, Water Rating::9.19, FL ID::17499, STC Rating::33 Unit Price: $384.58 185 Single Hung - Vent - F25 Extended Price: $2,692.06 Quoted by: Laura,Hammonds Quote Number, 2034205 Pages: 1 of 3 Print Date: 31141201811:35:52 Manning Building Supply -�J ITEM I>i SIZES; LOCATION /,TAG PRODUCT DESCRIPTION Line Item: 600-1 None Assigned "* PRODUCT — Quantity: 2 Row 1 185 Single Hung - Vent -1 Units - 25.5W x 62H *** DIMENSIONS *** RO Size: 27.25" X 6Y 25.5W x 62H Unit Size: 25.5" X 62" "` FRAME **' i South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color - White GLASS *** Glazing Type - Insulated, Glass Tint - Clear, Low-E 366, Argon Gas SCREEN *'* Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed .I Separately - Yes NFRC Series 185::SingleHung,-Factoc:0.58 SHGC::0.24, VT::0.52 Performance *** { Series 185::SingleHung, Calculated Positive DP Rating::60.15, ;.; Calculated Negative DP Rating::60.15, DP Rule ID::1851MPACT SH, Rating Type::DesignPressure, Structural Rating::R-PG60, Water Rating::9.19, FL ID::17499, STC Rating::33 Submitted By: Signature: Date: Accepted By: Signature: Date: Unit Price: $294.78 . Extended Price: $589.56 Sub Total: -$4,643.64 Freight: $0.00 Labor: $0.00 Sales Tax: $301.84 Total Order Price: $4,945A8 Product information and ratings in our Paradigm quoting tool are as accurate as possible from the latest release. We strive to have 100Waccuracy between our quoting tool and order acknowledgements. However, the acknowledgment is the FINAL RATING for all products. Customers are responsible for verifying ratings on their acknowledgment. Differences should be immediately reported to paradigmsupport@miwd.com. All ratings are for individual windows and doors only. For information regarding mulled or stacked units, please contact your sales representative. Quoted by: Laura Hammonds Manning Building Supply Quote Number. 2034205 Pages: 3 of 3 Print Data: 3/14/2018 11:35:52 i