Project Name: LEONHARD RESIDENCE
Builder Name: HARRY BLUE BUILDER
b-bti
Mp� 0
Street: 9710 RUSSOS ROAD
Permit Office: ST LUCIE COUNTY
Ga ogo
City, State, Zip: FORT PIERCE, FL, 34951
Permit Number: 1801-0616
`,%V;
Owner: ERIC LEONHARD
Jurisdiction: ST LUCIE COUNTY
St•�'�
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2182.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 2182.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (2463.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2463.00 ft2
6. Conditioned floor area above grade (ft2) 2463
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(222.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AHU
6 150
a. U-Factor: Sgl, U=0.58 150.00 ft2
SHGC: SHGC=0.24
b. U-Factor: Sgl, U=0.32 72.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.23
a. Central Unit
42.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.237
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2463.0 sqft.) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2463.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 70.93
PASS
Total Baseline Loads: 79.27
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
04,tIlE,S7'9?c�
Code.
calculation indicates compliance
``'a)S•
with the Florida Energy Code.
�' rNlli'9;: %'s522`? „
PREPARED BY: ` �'.�d
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
x �I'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Ener y Code.
COb,W. B.
OWNER/AGENT-
BUILDING OFFICIAL:
'DATE:
DATE:
.s
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
ALL PROJECTS require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1"2).
3/16/2018 10:35 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software File C op
crone oenCZ e)n!n
PROJECT
Title:
LEONHARD RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2463
Lot #
Owner Name:
ERIC LEONHARD
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
HARRY BLUE BUILDER
Rotate Angle:
0
Street:
9710 RUSSOS ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design
Temp
Heating Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2463
25508
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
MASTER BEDROO
351
3861
No
0
1
1
Yes
Yes
Yes
2
CABANA
42
420
No
0
1
Yes
Yes
Yes
3
WIC
36
360
No
0
1
No
Yes
Yes
4
M W IC 1
35
350
No
0
1
Yes
Yes
Yes
5
M WIC 2
42
420
No
0
1
No
Yes
Yes
6
LAUNDRY
61
610
No
0
1
No
Yes
Yes
7
HALL
24
240
No
0
1
No
Yes
Yes
8
MASTER BATH
144
1440
No
0
1
Yes
Yes
Yes
9
OFFICE
140
1400
No
1
1
Yes
Yes
Yes
10
OFFICE CLST
16
160
No
0
1
Yes
Yes
Yes
11
FOYER
91
910
No
0
1
Yes
Yes
Yes
12
CLST 2
24
240
No
0
1
No
Yes
Yes
13
BEDROOM 2
204
2040
No
0
1
1
Yes
Yes
Yes
14
BATH 2
88
880
No
0
1
Yes
Yes
Yes
15
BEDROOM 3
204
2040
No
0
1
1
Yes
Yes
Yes
16
CLST 3
24
240
No
0
1
Yes
Yes
Yes
17
'
HALLWAY
64
640
No
0
1
No
Yes
Yes
18
KITCHEN
337
3370
Yes
0
1
Yes
Yes
Yes
19
GREAT ROOM
527
5797
No
0
1
Yes
Yes
Yes
V 20
AHU
9
90
No
0
1
No
Yes
Yes
3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood' Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO 36 ft
0
351 ftZ
__-_
1
0
0
2 Slab -On -Grade Edge Insulation
CABANA
6 ft
0
42 ftZ
----
1
0
0
3 Slab -On -Grade Edge Insulation
WIC
1 ft
0
36 ftZ
1
0
0
4 Slab -On -Grade Edge Insulation
M W IC 1
7 ft
0
35 ftZ
___-
1
0
0
5 Slab -On -Grade Edge Insulation
M W IC 2
1 ft
0
42 ftZ
___-
1
0
0
6 Slab -On -Grade Edge Insulation
LAUNDRY
1 ft
0
61 ftZ
___-
1
0
0
7 Slab -On -Grade Edge Insulation
HALL
1 ft
0
24 ftZ
_--_
1
0
0
8 Slab -On -Grade Edge Insulation
MASTER BATH
24 ft
0
144 ftZ
--__
1
0
0
9 Slab -On -Grade Edge Insulation
OFFICE
lift
0
140 ftZ
____
1
0
0
10SIab-On-Grade Edge Insulation
OFFICE CLST
2 ft
0
16 ftZ
____
1
0
0
11SIab-On-Grade Edge Insulation
FOYER
7ft
0
91 ftZ
__--
1
0
0
12SIab-On-Grade Edge Insulation
CLST 2
1 ft
0
24 ftZ
__--
1
0
0
13SIab-On-Grade Edge Insulation
BEDROOM 2
17 ft
0
204 ftZ
--__
1
0
0
14SIab-On-Grade Edge Insulation
BATH 2
8 ft
0
88 ftZ
---_
1
0
0
15SIab-On-Grade Edge Insulation
BEDROOM 3
29 ft
0
204 ft'
----
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
24 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
64 ftZ
____
1
0
0
18SIab-On-Grade Edge Insulation
KITCHEN
15 ft
0
337 ftZ
__--
1
0
0
19SIab-On-Grade Edge Insulation
GREAT ROOM
46 ft
0
527 ftZ
__--
1
0
0
20SIab-On-Grade Edge Insulation
AHU
1 ft
0
9 ftZ
____
1
0
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area
Color
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 2668 ftZ
0 ftZ
Light
0.6
No 0.9
No
20
22.6
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0
2463 ft-
N N
3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) MASTER BEDRO 20
Blown
351 ft2
0.1
Wood
2
Under Attic (Unvented) CABANA
20
Blown
42 ft2
0.1
Wood
3
Under Attic (Unvented) WIC
20
Blown
36 ft2
0.1
Wood
4
Under Attic (Unvented) M WIC 1
20
Blown
35 ft2
0.1
Wood
5
Under Attic (Unvented) M W IC 2
20
Blown
42 ft2
0.1
Wood
6
Under Attic (U nvented) LAUNDRY
20
Blown
61ft2
0.1
Wood
7
Under Attic (Unvented) HALL
20
Blown
24 ft2
0.1
Wood
8
Under Attic (Unvented) MASTER BATH
20
Blown
144 ft2
0.1
Wood
9
Under Attic (Unvented) OFFICE
20
Blown
140 ft2
0.1
Wood
10
Under Attic (Unvented) OFFICE CLST
20
Blown
16 ft2
0.1
Wood
11
Under Attic (Unvented) FOYER
20
Blown
91ft2
0.1
Wood
12
Under Attic (Unvented) CLST 2
20
Blown
24 ft2
0.1
Wood
13
Under Attic (Unvented) BEDROOM 2
20
Blown
204 ft2
0.1
Wood
14
Under Attic (Unvented) BATH 2
20
Blown
88 ft2
0.1
Wood
15
Under Attic (Unvented) BEDROOM 3
20
Blown
204 ft2
0.1
Wood
16
Under Attic (Unvented) CLST 3
20
Blown
24 ft2
0.1
Wood
17
Under Attic (U nvented) HALLWAY
20
Blown
64ft2
0.1
Wood
18
Under Attic (Unvented) KITCHEN
20
Blown
337 ft2
0.1
Wood
19
Under Attic (Unvented) GREAT ROOM
20
Blown
527 ft2
0.1
Wood
20
Under Attic (Unvented) AHU
20
Blown
9 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
0
_ 1
N
Exterior Concrete Block - Ext InsLMASTER BE
4.1
19
0 11
0
209.0 ft2
0
0
0.6
0
_ 2
W
Exterior Concrete Block - Ext InsiWIASTER BE
4.1
17
0 11
0
187.0 ft2
0
0
0.6
0
• _ 3
N
Exterior Concrete Block - Ext Insul CABANA
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
_ 4
W
Exterior Concrete Block - Ext Insul M W IC 1
4.1
7
0 10
0
70.0 ft2
0
0
0.6
0
_ 5
S
Exterior Concrete Block - Ext InsLMASTER BA
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_ 6
W
Exterior Concrete Block - Ext InstWIASTER BA
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_ 7
S
Exterior Concrete Block - Ext Insul OFFICE
4.1
11
0 10
0
110.0 ft2
0
0
0.6
0
_ 8
S
Exterior Concrete Block - Ext InsdDFFICE CLS
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
_ 9
S
Exterior Concrete Block - Ext Insul FOYER
4.1
7
0 10
0
70.0 ft2
0
0
0.6
0
_ 10
S
Exterior Concrete Block - Ext Insi9EDROOM 2
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
_ 11
W
Exterior Concrete Block - Ext InstSEDROOM 2
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
_ 12
S
Exterior Concrete Block - Ext Insul BATH 2
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
_ 13
E
Exterior Concrete Block - Ext InsSEDROOM 3
4.1
17
0 10
0
170.0 ft2
0
0
0.6
0
_ 14
S
Exterior Concrete Block - Ext InstBEDROOM 3
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
•_ 15
E
Exterior Concrete Block - Ext Insul CLST 3
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
_ 16
N
Exterior Concrete Block - Ext Insul KITCHEN
4.1
15
0 10
0
150.0 ft2
0
0
0.6
0
_ 17
N
Exterior Concrete Block - Ext InstBREAT ROO
4.1
24
0 11
0
264.0 ft2
0
0
0.6
0
18
E
Exterior Concrete Block - Ext InstOREAT ROO
4.1
22
0 11
0
242.0 ft2
0
0
0.6
0
3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 1--,
Ct-%MRA onnG OnIA
DOORS
#
Omt
Door Type
Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1
2
N
S
Insulated
Insulated
CABANA
FOYER
None .27
None .27
2
3
8
8
16 ft2
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
#
Wall
Ornt ID Frame
Panes
NFRC
U-Factor SHGC Area
Overhang
Depth Separation
Int Shade
Screening
1
2
3
4
5
6
7
8
9
N 1 Metal
W 2 Metal
S 5 Metal
S 7 Metal
S 10 Metal
S 14 Metal
N 16 Metal
N 17 Metal
N 17 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
0.32 0.23 24.0 ft2
0.58 0.24 20.0 ft2
0.58 0.24 16.0 ft2
0.58 0.24 15.0 ft2
0.58 0.24 30.0 ft2
0.58 0.24 30.0 ft2
0.58 0.24 9.0 ft2
0.58 0.24 30.0 ft2
0.32 0.23 48.0 ft2
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft 4 in
2 ft 0 in 1 ft4 in
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse ProposedACH(50)
.000461
2975.9 163.37 307.25
.3363
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Split
SEER: 16 42 kBtu/hr 1260 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Exterior
0.98 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 /
Cnone onnXZ'3n4n
DUCTS
-- Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 150 ftz
Attic
15 ft2
Default Leakage
AHU
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling[[ ]] Jan
Heatin[X] Jan
[ ] Feb
Feb
[[ ]] Mar
[X] Mar
f
Apr
Apr f
] May
] May 4
X] Jun
] Jun
[X] Jul
] Jul
[X] Aug
[ ] Aug
[X] Sep
[ ] Sep
[ j
[ ]
Oct
Oct
[ ] Nov
[X] Nov
Dec
Dec
Venting[[ ]]Jan
4X]
]Feb
[[XX]] Mar
[X]
Apr (]
May [
]Jun
E ]Jul
[ ] Aug
[ ] Se p
[X]
Oct
[X] Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)
AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
3/16/2018 10:35 AM EnergyGaugeB USA - FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 /
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LEONHARD RESIDENCE Builder Name: HARRY BLUE BUILDER
Street: 9710 RUSSOS ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34951 Permit Number: 1801-0616
Owner: ERIC LEONHARD Jurisdiction: ST LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to.the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
3/16/2018 10:35 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 89
The lower the EnergyPerformance Index, the more efficient the home.
r
9710 RUSSOS ROAD, FORT PIERCE, FL, 34951
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows"
Description
a. U-Factor:
Sgl, U=0.58
SHGC:
SHGC=0.24
b. U-Factor:
Sgl, U=0.32
SHGC:
SHGC=0.23
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
Single-family
1
3
No
2463
Area
150.00 ft2
72.00 ft2
ft2
ft2
2.000 ft.
0.237
8. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 2463.00 ft2
b. N/A R= ft2
c. N/A R= ft2
9. Wall Types
a. Concrete Block - Ext Insul, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Roof Deck (Unvented)
b. N/A
c. N/A
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:_ Date: ty*4T
Address of New Hom=�� �p, City/FL Zip:
Insulation
R=4.1
R=
R=
R=
Insulation
R=20.0
R=
R=
Area
2182.00 ft2
ft2
ft2
ft2
Area
2463.00 ft2
ft2
ft2
R ft2
6 150
kBtu/hr Efficiency
42.0 SEER:16.00
kBtu/hr Efficiency
27.0 COP:1.00
Cap: 40 gallons
EF: 0.98
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/16/2018 10:35 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software
Page 1 of 1
DOIMP
Customer Name:
Address:
Phone:
Fax:
Customer Information:
Quote Date: 3/8/2018
Manning Building Supplies
3315 Oleander Ave
Ft. Pierce, FL 34982
Project Name:
LEONHARD RESIDENCE
Quote Name:
HARRY BLUE BLDRS
Quote Number: 2034205
Order Date:
Quote Not Ordered
PO Number:
Comments:
RO size for Flange is for standard 1x buck with precast sill. Please contact your supplier for other Flange opening RO's. Does
not apply to Western Region.
I'EM & SIZES LOCATION / TAG PRODUCT DESCRIPTION UNIT PRICE / EXTENDED PRI
Line ttem: 10d-1 None Assigned
Quantity: 1
RO Size: 53.875" X 50.625"
Unit Size: 52.125" X 49.625"
185 Single Huna - Vent - F34
"* PRODUCT —
Row 1 185 Single Hung - Vent -1 Units - 52.125W x 49.625H
**' DIMENSIONS ***
52.125W x 49.625H
**" FRAME **'
South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color
- White
*** GLASS
Glazing Type - Insulated, Glass Tint - Clear, Low-E 366 and Obscure,
Obscure Placement - Full, Argon Gas, Tempered Location - Full
*** SCREEN *
Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed
Separately - Yes
*'* NFRC ***
Series 185::SingleHung, U-Factor: a
SHGC::0.24, VT::0.52
*** Performance ""
Series 185::SingleHung, Calculated Positive DP Rating::60.15,
Calculated Negative DP Rabng::60.15, DP Rule ID::1851MPACT SH,
Rating Type::DesignPressure, Structural Rating::R-PG60, Water
Rating::9.19, FL ID::17499, STC Rating::33
Unit Price: $595.23
Extended Price: $595.23
ITEM S SIZES LOCATION) TAG -PRODUCT DESCRIPTION UNIT PRICE /:EXTENDED PRICE
Line Item: 20D-1 None Assigned **'PRODUCT`
Quantity: 7
RO Size: 37.75" X 63"
Unit Size: 36" X 62"
35
Row 1 185 Single Hung - Vent -1 Units - 36W x 62H
**' DIMENSIONS
36W x 62H
*"* FRAME
South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color
- White
"*' GLASS'"*
Glazing Type - Insulated, Glass Tint - Clear, Low-E 366, Argon Gas
*** SCREEN **'
Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed
Separately - Yes
* " NFRC '**
Series 185::SingleHung U-Factor.:0.58, HGC:.0.24, VT::0.52
*** Performance "
Series 185::SingleHung, Calculated Positive DP Rating::60.15,
Calculated Negative DP Rating::60.15, DP Rule ID::1851MPACT SH,
Rating Type;:DesignPressure, Structural Rating::R-PG60, Water
Rating::9.19, FL ID::17499, STC Rating::33
Unit Price: $384.58
185 Single Hung - Vent - F25 Extended Price: $2,692.06
Quoted by: Laura,Hammonds Quote Number, 2034205 Pages: 1 of 3 Print Date: 31141201811:35:52
Manning Building Supply
-�J
ITEM I>i SIZES; LOCATION /,TAG PRODUCT DESCRIPTION
Line Item: 600-1 None Assigned
"* PRODUCT —
Quantity: 2
Row 1 185 Single Hung - Vent -1 Units - 25.5W x 62H
*** DIMENSIONS ***
RO Size: 27.25" X 6Y
25.5W x 62H
Unit Size: 25.5" X 62"
"` FRAME **'
i
South, Aluminum, Frame Type - Flange, Impact, 55DP, Exterior Color
- White
GLASS ***
Glazing Type - Insulated, Glass Tint - Clear, Low-E 366, Argon Gas
SCREEN *'*
Screen - Half, Screen Mesh Type - Charcoal Fiber, Screens Packed
.I
Separately - Yes
NFRC
Series 185::SingleHung,-Factoc:0.58 SHGC::0.24, VT::0.52
Performance ***
{
Series 185::SingleHung, Calculated Positive DP Rating::60.15,
;.;
Calculated Negative DP Rating::60.15, DP Rule ID::1851MPACT SH,
Rating Type::DesignPressure, Structural Rating::R-PG60, Water
Rating::9.19, FL ID::17499, STC Rating::33
Submitted By:
Signature:
Date:
Accepted By:
Signature:
Date:
Unit Price: $294.78 .
Extended Price: $589.56
Sub Total: -$4,643.64
Freight:
$0.00
Labor:
$0.00
Sales Tax:
$301.84
Total Order Price:
$4,945A8
Product information and ratings in our Paradigm quoting tool are as accurate as possible from the latest release. We strive to
have 100Waccuracy between our quoting tool and order acknowledgements. However, the acknowledgment is the FINAL
RATING for all products. Customers are responsible for verifying ratings on their acknowledgment. Differences should be
immediately reported to paradigmsupport@miwd.com. All ratings are for individual windows and doors only. For information
regarding mulled or stacked units, please contact your sales representative.
Quoted by: Laura Hammonds
Manning Building Supply
Quote Number. 2034205
Pages: 3 of 3 Print Data: 3/14/2018 11:35:52
i