INSULATION INSTALLATION CERTIFICATION
Building Permit # Wv1 ` 66 Site Address: 9 ` 1 o eass6 eO aCa T
Street City State Zip
The undersigned hereby certifies that insulation has been installed in the above -described property to meet
the minimum requirements for R-Value of the Florida Energy Efficiency Code in accordance with the approved
plans and specifications, as follows:
I. Exterior walls have been insulated with :(check one from list) to a spray on cellulose
thickness of� _inches, which thickness, according to the Fiberglass batts
manufacturer will yield an'R'value of at bags Rock wool Batts
per square feet Aluminum Foil
Polyurethane
Polystyrene
Other
2. Ceilings have been insulated with (check one from list) to a
Thickness of '_inches, which thickness, according to the Fiberglass blankets
manufacturer will yield an 'R' value of vp at bags Fiberglass loose Fill
per -square feet �hounc3u� � Rock Wool blankets
Manufacturer: Rock wool loose fill
Cellulose loose fill
Other
3. Interior/Adjacent Tenant Walls have been insulated with 16a7 to
a thickness of .3.5 inches which, according tq the manufacturer, will yield an'R' value
Of 13 _ , . Manufacturer:g j 4
4. Garage partition walls of conditioned living area have been insulated.with to
A thickness of inches which, according to the manufacturer, will yield an 'R' value
Of Manufacturer:
The following areas have not been insulated:
Insulation Contractor
& ..gin &!"cols
Company Name. C:4u4m�Ci number
- C 6C1Qo91a3
Contractor's Name License #
G a&L
4=61 Vic
12
Con tractor's Signature Date —
General Contractor/Builders
Company Name CC number
Contractor's Name License #
Contractor's Signature Date
TECHNICAL DATA SHEET
Material Specification Criteria I Project Submittal Data
FOAMSULATE 50 N-IB
LIGHT DENSITY • OPEN CELL FOAM
An Accella Brand
Foamsulate 50 N-IB is a two component, light density, one to one by volume spray applied polyurethane foam. To produce Foamsulate 50 N-IB
requires the use of an "A" component (ISO) and a blended "B" component (RESIN), which contains ZERO ozone depleting blowing agents,
catalysts, polypils and fire, retarding materials Foamsulate 50 N-IB is an insulation system designed for use in residential, commercial and
industrial applications. Use in lieu of more traditional forms of insulating materials such as fiberglass, cellulose or other loose fill products. Typical
area's where spray polyurethane foam is applied are:
EXTERIOR WALLS • VENTED ATTIC'S • UN -VENTED ATTIC ASSEMBLIES • BETWEEN FLOORS • CEILINGS
TYPICAL PHYSICAL PROPERTIES:
f R-VALUE
3.7 @ 1"
ASTM C 518
.,CORE DENSITY �
0.5 LB / Cubic Foot
ASTM D 1622
.OPEN CELL CONTENT
> 92%
ASTM D 6226
SOUND TRANSMISSION
COEFFECIENT
39
ASTM E 413
BUILDING CODE CERTIFICATION,SDATA
EVALUATION SERVICE REPORT -
IAPMO 394
FLAME SPREAD`
ASTM E84 0 Zero Flame Spread
SMOKE DEVELOPMENT
ASTM E84 Class I < 450
NFPA 286"
Pass: Can be used without a code prescribed 15-minute thermal barrier when covered
with the approved intumescent coating as shown on page 2.
AC377APPENDIX X
Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in
attics and crawlspaces without a prescriptive ignition barrier.
'UL GREENGUARD GOLD
GOLD: UL 2818 - 2013 Standard for Chemical Emissions for Building Materials, Finishes and Furnishings
GENERAL PROPERTIES: Foamsulate 50 N-IB is a low viscosity, 0.5 pcf density open cell insulating material. Foamsulate 50 NAB is designed to
provide significant control of air infiltration along with a high R-value per inch. When properly installed by a professional application company
Foamsulate 50 N-IB quickly expands to fill the cracks, crevices, gaps and voids that exist in every structure. In addition Foamsulate 50 NAB
will conform to the curves, irregular surfaces and spaces to form a superior thermal envelope around your entire structure.
THERMAL BARRIER: Current International Building Code (IBC) and International Residential Code (IRC) require that spray polyurethane foam
be separated from the building interior by a code prescribed 15-minute thermal barrier or a code -approved alternative. Gypsum board at a
minimum thickness of 1/2" is a code prescribed 15-minute thermal barrier. The following intumescent coating when installed per manufacturer
specifications is approved as a thermal barrier alternative for Foamsulate 50 N-IB.
FOAMSULATE 50 N-IB
LIGHT DENSITY • OPEN CELL FOAM
APPROVED INTUMESCENT COATINGS:
DC315Tm manufactured by: Application Rates:
Fireproof Technology, Inc 18 Wet Mils -12 Dry Mils
Explanation of the thermal barrier requirement is available on IAPMO
Report #394 and at www.uniform-es.org.
IGNITION BARRIER: Foamsulate 50 N-IB meets the requirements of
[CC -ES AC377 and Appendix X for use in attics and crawlspaces
without the use of a prescriptive ignition barrier under the following
conditions:
Entry is only to service utilities in the attic or crawl space and no storage
a
Is permitted.
b
Attic or crawl space areas cannot be Interconnected.
Air from the attic or crawl space cannot be circulated to other parts of
c
the building.
d
In accordance with IBC Section 1203.3 or IRC Section R408.1, under-
floor (crawl space) ventilation is provided, as applicable.
In accordance with IBC Section 1203.2 or IRC Section R806, attic
e
ventilation is provided, as applicable.
In accordance with 2012 and 2009 IMC (International Mechanical
f
Code®) Section 701, or 2006 IMC Sections 701 and 703, combustion
air is provided.
The foam plastic insulation is limited to the maximum thickness and
9
density tested.
h
The installed coverage rate of coatings, if part of the insulation system
shall be equal or greater than that tested.
Explanation of these requirements is available on IAPMO Report #394
and at www.unifor7n-es.org.
VAPOR RETARDER: Open cell foam insulation is vapor permeable and
will allow some diffusion of moisture through the product. Consult
local building code officials for specific requirements. Climate zone
tables are available in current IBC and IRC publications.
APPLICATION GUIDELINES: Polyurethane foam systems should
be processed through commercially available spray equipment
designed for that purpose by a qualified professional applicator.
Consult the current Premium Spray Products application guidelines
for Foamsulate 50 N-IB prior to installation. It is the responsibility of
the professional applicator to thoroughly understand all equipment
technical Information and safe operating procedures that pertain to a
spray polyurethane foam application.
MANUFACTURED BY
ACCELLA POLYURETHANE SYSTEMS, LLC
100 Enterprise Drive Cartersville, GA 30120
(770) 607-0755 • PremiumSpray.com
An Accella Brand
MATERIAL HANDLING: Due to the reactive nature of these components
respiratory protection is mandatory. The vapors and liquid aerosols
present during application and for a short period thereafter must
be considered — and appropriate protective measures taken — to
minimize potential risks from overexposure through inhalation,
skin, or eye contact. These protective measures include: adequate
ventilation, safety training for installers and other workers, use
of appropriate personal protective equipment, and a medical
surveillance program. It is imperative that the applicator read and
become familiar with all available information on proper use and
handling of spray polyurethane foam. Additional Information is
available at spraypolyurethane.org, polyurethane.org or by contacting
the Premium Spray Products Technical Services dept. of Accella
Polyurethane Systems, LLC.
PROPER STORAGE OF RAW MATERIALS: Shelf life is twelve (12)
months from date of manufacture when stored indoors, in the original
unopened containers and between the temperatures of 40°-80°F.
TECHNICAL ASSISTANCE: For additional assistance please contact
the Premium Spray Products Technical Services dept. of Accella
Polyurethane Systems, LLC. at (770) 607-0755.
DISCLAIMER: To the best of our knowledge, all technical data
contained herein is true and accurate as of the date of issuance and
subject to change without prior notice. User must contact Premium
Spray Products to verify correctness before specifying or ordering. We
guarantee our products to conform to the quality control standards
established by Premium Spray Products. We assume no responsibility
for coverage, performance or injuries resulting from use. Liability, if
any, is limited to replacement of the product. NO OTHER WARRANTY
OR GUARANTEE OF ANY KIND IS MADE BY PREMIUM SPRAY
PRODUCTS EXPRESSED OR IMPLIED; STATUTORY, BY OPERATION
OF LAW, OR OTHERWISE, INCLUDING MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
rSPFA�t
ES
PCP
NG. •D
k
�a
ACCELLA
POLYURETHANE SYSTEMS
EMERGENCY NOTIFICATIONS:
CHEMTREC : Material Leaks, Spills or Fire (800) 424-9300