HomeMy WebLinkAboutTRUST PLACEMENT PLANbo M to *WARNING* -THIS IS A PLACEMENT PLAN FOR ENGINEERED -BRACING: SEE FINAL ENGINEERING SHEETS FOR THE BACK CHARGES WILL NOT BE ACCEPTED UNLESS OUR COMPONENTS AS DEFINED BY WTCA 1 - 1995. 1) FOR THE ERECTION BRACING FOLLOW STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS DESIGN DEPARTMENT APPROVES THEM IN ADVANCE ALL BEARING POINTS MUST BE DIAPHRAMS HAVE NOT BEEN ANALYZED BY INSTRUCTIONS ON THE BC8I-B1 SUMMARY SHEETS PLIES AND THE CONNECTION INFORMATION. ALL HANGERS ARE SIMPSON STRONG -TIE OR USP INSTALLED PRIOR TO INSTALLING EAST COAST TRUSS. 2) PERMANENT BRACING FOR THE STRUCTURE IS HE OUR DESIGN DEPARTMENT MUST APPROVE UNLESS OTHERWISE NOTED. INSTALL HANGERS -FOR ERECTION AND INSTALLATION OF TRUSSES RESPONSIBILITY OF OTHERS. ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ACCORDING TO THE CURRENT SIMPSON STRONG -TIE ANY TRUSSES! FAILURE TO DO SO MAY RESULT FOLLOW INSTRUCTIONS ON THE BCSI-B1 SUMMARY 3) INSTALL WEB BRACING AS STATED ON SEALED ADVANCE. OR USP CATALOG IN DAMAGED TRUSSES AND WILL VOID ALL WARANTIES. SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS ENGINEERING TRUSS DRAWINGS ZCJ ZCJ ZCJ 0 ZEJ7 04:1111YA ZEJ7 ZEJ ZEJ7 PFAMO ri ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZEJ7 ZE, 00 M ZE, ZE, ZE, ZE, ZE, ZE, ZE, ZE. ZE. h ZC. b ZC, ZC. Zin s- M U7 0 co IN N N Ir s— r r r r r I I {� r I r I— T r r r r I N l'd V N N N N N N N N N N N. N N N N N (N N N N N N N 0 C) U Q--- Q-- � e N--- N---N-- <---<---� ----- I I - <- <- <- -<- - <-Q_---<---<---<----<-- Q--- Q--- Q--- <--- Q--- Q--- Q--- <--- Q--- Q--- ¢---N---N --N V I 1' ZCJ 1 3 ZCJ3 5P ZCJ5 1 0 ZEJ7A N! 6' 10 1/2" On �, 0", 2' On 2, �„ 2' On 2, O 2. 2 On �t O 1' 11t 0" i O„ 2' On ' On - Ot - Ot t 0" t On _i Ot _ i " O t O, 0 ' " 610 1/2 ' " qlt I ZEJ7A q, ZEJ7A I t 7' ZEJ7 N N I z / / / / i ZEJ7T T / � to R Q a < CoN < < 0 < 03 CO G 0 Q < 'V 0 < M 0 < M 0 < M 0 < M 0 < N 0 < N 0 < N 0 < N 0 < c Lf)O < O < O / �- / /� / < / / / / / / ZEJ7T T /h ZEJ7T L,_ w ✓ i / / / / /I / o II N / / / ZEJ7T T v ✓ ; / T w to i N ip ' / LU ZEJ7T I m m com m m m m 00 ; i - — ZEJ7T T / / / w/ Q / ZEJ7T M T 2' 4" 14' 4" ;4- LO 7' -- - -- i 7 / ZEJ7T 112'6'. ZEJ7T w I ' 4" 7 I ZEJ7 7' I ZEJ7 T ZEJ7 T" Or Z, O" 2, 0" 2, 0„ 2' O" 2, O, - , 2 O" 2' O" O„ 2, O„ - O" O" 1' 8t t 0" , 0" , 0t , Ot Ott O" On Ort t O" On D 7, 0„ - 7 I -- - -.-. --._ - ZEJ7 71 I ZEJ7 I T ZEJ7 \ I 71 ZEJ7 I 1 5 ZCJ5 3 ZCJ3 1 ZCJ 1 I 0.----- --- ---- ---- '--- ---- ---- - ---- ---- ---- ---- ---- ---- -- A--- --- --- ---- [A----- --- - --- - -----' ijf ---- --- - --'-Ln — M N N N 31' 8" 63' 8" L) M M Yam, N N 32' 0" MAI' PLATE HT. Indicates Left End Of Truss On Layout & Engineering Sheets 6 3416" 5 I— ENGINEERED TIMBER TRUSS SYSTEMS PRODUCTS ECTr+— O r ]EAST COAST TRUSS (D 5285 ST. LUCIE BLVD, FF. PIERCE, FL 349646 0) OFFICE: (772) 466-2480 FAX: i7721466-5336 co� L. _ 06 - USTOMER:Harry Blue Bldrs. Inc. -- - )B NAME: Leonhard Res. DDRESS:Lot 69 & 70 Duece Park ITY/COUNTY:Ft. Pierce/St. Lucie DB # J34908 RECEIVED JB # JAN 2 6 2018 ODEL:Custom ST. Lude County, Permitting D FT 3423 ATE 11/14/17 (LATEST=/ / IN ACCORDANCE WITH THE FLORIDA ADMINISTRATIVE CODE 61C15S-31.003 (3) (x), EAST COAST TRUSS Is the "Truss Design Engineer" Trusses ere deviated In extortioner with the Florida Building Code NOTE: ^ By approving this placement plan(s), signatured anywhere on this sheet, the customer or his representitive acknowledges that this placement plan i complies with the structural intent of the project. The customer also acknowledges that this approval 1 authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this I drawing. The customer also acknowledges that he/she accepts J financial responsibility for any repair, engineering, and labor required due to errors other than those of EAST Q COAST TRUSS. z Signed: Date: LL CODE = FBC 2014/TP12007 ASCE 7-10 W DESIGN CRITERIA =MWFRS OCCUPANCY CATEGORY= II C G EXPOSURE = C Q < MWF SPEED =170 BUILDING TYPE =ENCLOSED MEAN HEIGHT: 19.67 GRAVITY LOADS U) W FLOOR: DUR FACTOR= 1.0 J PSF=TCLL-TCDL-BCLL-BCDL z 40.0,10.0,0.0,5.0 ROOF: DUR FACTOR= 1.25 U) PSF=TCLL-TCDL-13CLL-BCDL W 20.0110.010.0110.0 U) (J) LOADS PER FBC & FRC "NON -CONCURRENT BC LL 10psf N CONCURRENT BC STORAGE LL 20 psf I— laseass DEFINITIONS MWF = MAIN WIND FORCE O C&C = COMPONENTS AND CLADDING TOB = TOP OF BEARING TIC = TOP CHORD W BC = BOTTOM CHORD iln LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT I— # =POUNDS UPLIFT MUST BY-PASS FLOOR TRUSSES z UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. O ALL GIRDER/COLUMN LOADS MUST BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. 2X6 STRONG BACK BRACING, 10r-O" O.C., IS >- RECOMMENDED ON FLOOR TRUSSES r1 SPANNING 20'-Or' OR MORE LOB ;AUTION: SPANS GREATER THAN 30'-0" RUST BE SET WITH A SPREADER BAR. THE U SPREADER BAR SHOULD BE AT LEAST 1/2 O J 1/3 IN LENGTH AS THE SPAN OF THE TRUSS Q 3EING SET, ZEFER TO BCI-B1 FOR COMPLETE O ERECTION AND SAFETY PROCEDURES. 0 ALL BEAMS BY BUILDER NOTE: TRUSSES DO NOT 0. SUPPORT ANY PLANT SHELVES REVI Cam—" ,S 2- `r 3- 4- 5- 6- M TRUSS PLACEMENT PLAN (1/4" if plotted 24x36) . Designed By: SB