Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 MAR 19'. 018 / W 5T, Lucie County, Permitting FLORIDA ENERGY C CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: VOSSEN RESIDENCE Builder Name: SOUTHERN CITY DEVELOPMENT Street: 5817 SILVER OAK DRIVE ,-8-1GANNE101 Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE , FL, 34982 BY Permit Number: 1801-0601 Owner. JOHN AND RACHEL VOSSEN County Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce at Dacia County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2114.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1874.00 ftZ b. Frame - Wood, Adjacent R=13.0 240.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 3 d. N/A R= ftZ 10. Ceiling Types (1995.0 sqft.) Insulation Area 5. Is this a.wdrst case? NO a. Roof Deck (Unvented) R=20.0 1995.00 ftZ 6. Conditioned floor area above grade (ftZ) 1995 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows (314.7 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 150 a. U-Factor: Sgl, U=0.58 288.67 ftZ SHGC: SHGC=022 b. U-Factor: Sgl, U=0.43 18.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.24 a. Central Unit 35.4 SEER:16.00 c. U-Factor: Sgl, U=0.43 8.00 ftZ SHGC: SHGC=0.26 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.222 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1995.0 sgft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1995.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits None Glass/Floor Area: 0.158 Total Proposed Modified Loads: 63.78 PASS Total Baseline Loads: 68.29 I hereby certify that the plans and specifications covered by Review of the plans and SHE S7,,1?, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance - rig;°'' with the Florida Energy Code. N nnir"� `:•`�,� PREPARED Y: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 0. I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. �b with {rr►�,'L� OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). -file Copy 3/13/2018 11:08 AM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 I3e7c4i"Zri9WiIFA PROJECT Title: VOSSEN RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1995 Lot # Owner Name: JOHN AND RACHEL VOSSE Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: SOUTHERN CITY DEVELOP Rotate Angle: 0 Street: 5817 SILVER OAK DRI Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE , Family Type: Single-family FL, 34982 New/E)asting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1995 16867 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MUD ROOM 116 928 No 0 1 Yes Yes Yes 2 ENTRY 24 192 No 0 1 No Yes Yes 3 UTILITY 64 512 No 0 1 Yes Yes Yes 4 DINING 143 1144 No 0 1 Yes Yes Yes 5 KITCHEN 154 1232 Yes 0 1 Yes Yes Yes 6 GREAT ROOM 323 3230 No 0 1 Yes Yes Yes 7 DEN 144 1152 No 0 1 Yes Yes Yes 8 FOYER 50 400 No 0 1 Yes Yes Yes 9 BEDROOM 2 144 1152 No 0 1 1 Yes Yes Yes 10 WIC 3 30 240 No 0 1 Yes Yes Yes 11 WIC 2 30 240 No 0 1 Yes Yes Yes 12 BEDROOOM 3 144 1152 No 0 1 1 Yes Yes Yes 13 BATH 2 48 384 No 0 1 No Yes Yes 14 HALL 24 192 No 0 1 No Yes Yes 15 MASTER BATH 158 1264 No 0 1 Yes Yes Yes 16 M TOILET 46 368 No 0 1 No Yes Yes 17 M WIC 1 32 256 No 0 1 Yes Yes Yes 18 M W IC 2 40 320 No 0 1 No Yes Yes 19 M HALL 20 160 No 0 1 No Yes Yes 20 MASTER BEDROO 261 2349 No 0 1 1 Yes Yes Yes 3/13/2018 11:08 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # • Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MUD ROOM 19 ft 0 116 ft2 ____ 1 0 0 2 Slab -On -Grade Edge Insulation ENTRY 1 ft 0 24 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation UTILITY 8 ft 0 64 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation DINING 17 ft 0 143 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation KITCHEN 17 ft 0 154 ft2 1 0 0 6 Slab -On -Grade Edge Insulation GREAT ROOM 17 ft 0 323 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulation DEN 24 ft 0 144 ft2 __-- 1 0 0 8 Slab -On -Grade Edge Insulation FOYER 5 ft 0 50 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulation BEDROOM 2 24 ft 0 144 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation WIC 3 5 ft 0 30 ft2 --_- 1 0 0 11SIab-On-Grade Edge Insulation WIC 2 lift 0 30 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation BEDROOOM 3 12 ft 0 144 ft2 _-__ 1 0 0 13SIab-On-Grade Edge Insulation BATH 2 1 ft 0 48 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 24 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation MASTER BATH 9 ft 0 158 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation M TOILET 1 ft 0 46 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation M W IC 1 8 ft 0 32 ft2 ____ 1 0 0 18SIab-On-Grade Edge Insulation M W IC 2 1 ft 0 40 ft2 ____ 1 0 0 19SIab-On-Grade Edge Insulation M HALL 1 ft 0 20 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation MASTER BEDRO 48 ft 0 261 ft2 ____ 1 0 0 ROOF v Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2231 ft2 0 ft2 Medium 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1995 ft2 N N 3/13/201811:08 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MUD ROOM 20 Blown 116 ft2 0.1 Wood 2 Under Attic (Unvented) ENTRY 20 Blown 24 ft2 0.1 Wood 3 Under Attic (U nvented) UTILITY 20 Blown 64ft2 0.1 Wood 4 Under Attic (Unvented) DINING 20 Blown 143 ft2 0.1 Wood 5 Under Attic (Unvented) KITCHEN 20 Blown 154 ft2 0.1 Wood 6 Under Attic (Unvented) GREAT ROOM 20 Blown 323 ft2 0.1 Wood 7 Under Attic (Unvented) DEN 20 Blown 144ft2 0.1 Wood 8 Under Attic (U nvented) FOYER 20 Blown 50ft2 0.1 Wood 9 Under Attic (Unvented) BEDROOM 2 20 Blown 144 ft2 0.1 Wood 10 Under Attic (Unvented) WIC 3 20 Blown 30 ft2 0.1 Wood 11 Under Attic (Unvented) WIC 2 20 Blown 30 ft2 0.1 Wood 12 Under Attic (Unvented) BEDROOOM 3 20 Blown 144 ft2 0.1 Wood 13 Under Attic (Unvented) BATH 2 20 Blown 48 ft2 0.1 Wood 14 Under Attic (Unvented) HALL 20 Blown 24 ft2 0.1 Wood 15 Under Attic (Unvented) MASTER BATH 20 Blown 158 ft2 0.1 Wood 16 Under Attic (Unvented) M TOILET 20 Blown 46 ft2 0.1 Wood 17 Under Attic (U nvented) MWIC1 20 Blown 32ft2 0.1 Wood 18 Under Attic (Unvented) M W IC 2 20 Blown 40 ft2 0.1 Wood 19 Under Attic (Unvented) M HALL 20 Blown 20 ft2 0.1 Wood 20 Under Attic (Unvented) MASTER BEDRO 20 Blown 261 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 W Exterior Concrete Block - Ext InsLIVIUD ROOM 4.1 19 0 8 0 152.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext Insul UTILITY 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 3 W Exterior Concrete Block - Ext Insul DINING 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 4 N Exterior Concrete Block- Ext Insul DINING 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Ext Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Ext Insul KITCHEN 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext InsdGOREAT ROO 4.1 17 0 10 0 170.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Ext Insul DEN 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block - Ext Insul DEN 4.1 12 0 8 0 96.0 W 0 0 0.6 0 10 S Exterior Concrete Block - Ext Insul DEN 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 11 E Exterior Concrete Block - Ext Insul FOYER 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 12 N Exterior Concrete Block - Ext InsL8EDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 13 E Exterior Concrete Block - Ext InsMEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 14 S Exterior Concrete Block - Ext InstSEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 15 N Exterior Concrete Block- Ext Insul WIC 3 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block - Ext Insul WIC 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 17 E Exterior Concrete Block- Ext Insul WIC 2 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block - Ext InsI3EDR000M 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 19 N Exterior Concrete Block - Ext InsLKIASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 20 N Exterior Concrete Block - Ext Insul M WIC 1 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 3/13/2018 11:08 AM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 21 W Exterior Concrete Block - Ext InsMASTER BE 4.1 18 0 9 0 162.0 ft2 0 0 0.6 0 22 N Exterior Concrete Block - Ext InsHASTER BE 4.1 14 0 9 0 126.0 ft2 0 0 0.6 0 23 S Exterior Concrete Block - Ext InsLWIASTER BE 4.1 16 0 9 0 144.0 ft2 0 0 0.6 0 24 E Garage Frame - Wood MUD ROOM 13 11 8 88.0 ft2 0 0 0.600000 0 25 S Garage Frame - Wood UTILITY 13 19 8 152.0 ft2 0 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Metal Low-E Single Yes 0.58 0.22 N 33.3 ft2 2 ft 0 in 1 ft 4 in None None 2 E 2 Metal Low-E Single Yes 0.43 0.24 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 3 W 3 Metal Low-E Single Yes 0.58 0.22 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 4 N 4 Metal Low-E Single Yes 0.58 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 5 Metal Low-E Single Yes 0.43 0.24 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 7 Metal Low-E Single Yes 0.58 0.22 N 85.3 ft2 2 ft 0 in 1 ft 4 in None None 7 E 9 Metal Low-E Single Yes 0.58 0.22 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 13 Metal Low-E Single Yes 0.58 0.22 N 30.0 ft2 2 ft 0 in 1 ft 4 in None None 9 N 18 Metal Low-E Single Yes 0.58 0.22 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 10 N 19 Metal Low-E Single Yes 0.43 0.24 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 11 W 21 Metal Low-E Single Yes 0.58 0.22 N 20.0 ft2 2 ft 0 in 1 ft 4 in None None 12 W 21 Metal Low-E Single Yes 0.58 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 13 N 22 Metal Low-E Single Yes 0.43 0.26 N 8.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 576 ft2 576 ft2 30 ft 8 ft 13 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 1967.8 108.03 203.17 .2745 7 3/13/201811:08 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 35.4 kBtu/hr 1062 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 150 ft2 Attic 15 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Heatin Feb Jan Feb Mar Mar Apr f Apr [ j May Jun Jul [ ] May 4 Jun Jul [X] Au [ ] Au4 Se Sep f Oct Oct Nov Nov Dec Dec VentingJan Feb Mar [X] Apr [ ] May [ Jun Jul [ ] Aug [ Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/13/201811:08 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA , Project Name: VOSSEN RESIDENCE Builder Name: SOUTHERN CITY DEVELOPMENT Street: 5817 SILVER OAK DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE , FL, 34982 Permit Number: 1801-0601 Owner: JOHN AND RACHEL VOSSEN Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipina and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/13/2018 11:08 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 5817 SILVER OAK DRIVE, FORT PIERCE, FL, 34982 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1874.00 ft2 b. Frame - Wood, Adjacent R=13.0 240.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1995.00 ft2 6. Conditioned floor area (ft2) 1995 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.58 58 288.67 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 150 SHGC: SHGC= .22 b. U-Factor: Sgl, U=0.43 18.00 ft2 SHGC: SHGC=0.24 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.43 8.00 ft2 a. Central Unit 35.4 SEER:16.00 SHGC: SHGC=0.26 d. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.222 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1995.00 ft2 a. Electric EF: 0.98 ' b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/13/2018 11:08 AM EnergyGauge@) USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsoft" Project Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fa)c 772466-6796 Email: QUICKCALCS@,AOL.COM For: VOSSEN RESIDENCE, SOUTHERN CITY DEVELOPMENT 5817 SILVER OAK DRIVE, FORT PIERCE, FL 34982 Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 25706 Btuh Ducts 5999 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 31705 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Coolingg� Area (ft2) 1995 1995 Volume (ft3) 16867 16867 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 107 56 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.8 kW 30123 BFuh 1180 cfm 0.037 cfm/Btuh 1.00 in H2O Job: Date: MARCH 13, 2018 By: Plan: 1801-0601 Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 19325 Btuh Ducts 7498 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturers data Rate/swing multiplier n 0.95 Equipment sensible load 25482 Btuh Latent Cooling Equipment Load Sizing Structure 3099 Btuh Ducts 2340 Btuh Central vent 0 cfm) 0 Btuh Equipment latent load 5439 Btuh Equipment total load 30921 Btuh Req. total capacity at 0.70 SHR 3.0 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond CA16NW0360000A Coil FX4DNB037L AHRI ref 7693195 Efficiency 13.5 EER, 16 SEER Sensible cooling 24780 Btuh Latent cooling 10620 Btuh Total cooling 35400 Btuh Actual air flow 1180 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed " wrightsoft® 2018-Mar-1311:00:00 �- Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 14CCA E:\Documnets\Wrightsoft WAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E File Copy wrightsoft' Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 By: QUICK CALCS, INC. Plan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area Entire House 224.0 ft 8.5 ft 1995.0 ftz MUD ROOM 19.0 ft 8.0 ft heat/cool 1.0 x 116.0 ft 116.0 ftz Ty Construction number U-value (Btuh/ftz-'F) Or HTM (Btuh/ftz) Area (ft-) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ^' - 13A flocs - -- 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr_low=e___ 13A-4ocs 2 glazing, ,clr low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazinq, clr low-e ^, 13AAms 2'glazing, clr low-e 2 glazing, clr low-e 11DO -=-__------ 13A-4ocs--- -- -_30ad__ 22htph - 0.143 0.650 0.650 0.650 0.650 0.650 0.143 0.650 0.650 0.650 �_-__0.650 0.143 0.650 0.650 0.390 ----0.143 0.032 1.356 n n n n n __n_ a a a a _ e- s s s _ s . w ___- 4.00 18.20 18.20 18.20 18.20 __ 18.20 4.00 18.20 18.20 18.20 18.20 4.00 18.20 18.20 10.92 4.00 . _ _ 0.90 38.02 2.19 14.99 14.99 14.99 14.99 ,_ 14.99'_ 2.19 30.39 31.52 32.42 -_ 32.42 l 2.19 14.99 14.99 10.34 -- 2._1_9 _ __.2.24 0.00 572 20 15 40 34 85 518 8 6 15 ----,-20 432 12 60 _ --_20 ---352 __ _ 1995 9995 378 0 0 0 0 0 1514 364 273 728 610 :_ 1553 1878 146 109 273 364 1360 218 1092 r_-___223 _ .._ 1409 _1788 8517 ----__ - 827 300 225 600 502 ._1279 1026 243 189 486 648 743 180 899 --- _ 211. - - 770 _;___44_69 0 ---------- 152 0 0 0 34 _0 0 0 0 0 0 0 0 0 -_-----_0.•--_ -- -0 _ __ 11E 116 _ ..._._ _ 1f- 0 0 0 0 - 0 0 0 0 0 0 0 0 0 ___0 -- - -0 116 19 . _ _.-_- 474 0 0 0 610 0. .-_--- 259 0 0 0 502 _ 0 0 0 0 0 0 0 0 0 - -- - 0 __-___ 260 0 _ - 469 1 1 1 _ _ 1 -4340 12 60 ------___20 ----352 ___,_ 1995....__ 224 _-. 0 0 0 0 0 0 0 0 - _..,-_ 104 722 Vd/ !L�-CGp W C16A -- F 6 c) AED excursion 0 -1 Envelope loss/gain 22419 13598 1911 1021 12 a) Infiltration b) Room ventilation 3287 0 927 0 267 0 75 0 13 Intemal gains: Occupants @ 230 Appliances/other 0 0 4800 0 0 0 Subtotal (lines 6 to 13) 1 25706 19325 2177 1096 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 0 25706 5999 0 0 0 19325 7498 23% 39% 0 0 8 2185 510 0 0 20 1116 433 Total room load Air required (cfm) 31705 1180 26824 1180 2695 100 1549 68 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Pk wrightsoft' Right Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 Page 1 �� E:\Documnets\W6ghtsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoft° Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 By: QUICK CALCS, INC. Plan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name EVosed wall Room height Room dimensions Room area ENTRY 0 ft 8.0 ft heat/cool 6.0 x 4.0 ft 24.0 ft2 UTILITY 8.0 ft 8.0 ft heat/cool 8.0 x 8.0 ft 64.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - - -- - _ - ---- 13A-4ocs 2 glazing, clr lower 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2.glazing,_clr low e___- 13AAocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e _? glazinq._clr„low-e____ 13A�ocs 2 glazing, clr lower 2 glazing, clr low-e 13A-4ocs _ .._- ., 30ad___� 22A-tph -- ---- 0:143 0.650 0.650 0.650 0.650' Y-_0.650 0.143 0.650 0.650 0.650 0,650 0.650 0.650 0.650 0_390 _. 0143 1.358 -- n n n n n -n_ a a a a ---e- s s s - s _ w_ ..._ _- 4.00 18.20 18.20 18.20 18.20 ___18.20 4.00 18.20 18.20 18.20 --_ 18.20 8.20 1820 18.20 . -10.92 4.00 - 0,90_24 38.02 -- - 2.19 14.99 14.99 14.99 14.99 --14.99 2.19 30.39 31.52 32.42 _____32,42 2.19 14.99 14.99 ____10.34 2.19 0.00 ---e---__ 0 0 0 0 01 0 0 0 0 0 0 0 0 _ 0 __-_._._. 0 24 0 0 0 0 0 0 0 0 0 --- ---_9 0 0 0 _.__ 0 0 0 0 0 0 0 0 0 0 ----____ 0 0 0 0 ____0 _______0 0 0 0 0 0 0 0 0 0 ____.-----.-0 0 0 0 �_ . 0 . _--.__ 0 0 0 0 0 0 0 ____0 0 0 0 0 --- __-- 0 64 6 0 ____Q -._.._ 0 64 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .._ _ _-. 0 109 109 0 0 304 0 0 0. 0 0 __.____­ 0 0 0 0 �__ . _. 0 58 6 0 --. _A__- ---.. _ 0 8 0 0 0 0 ----_-0 90 190 0 ---0 0 W F _.- 0 _ _ - 22 0 - 6 c)AED excursion 0 0 Envelope loss/gain 22 541 703 360 12 a) Infiltration b) Room ventilation 0 0 0 0 112 0 32 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 22 54 815 392 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 -22 0 0 0 0 -54 0 0 23% 39% 0 0 8 823 192 0 0 20 412 160 Total room load Air required (cfm) 0 01 0 0 1015 38125 572 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 4 wrightsoft Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 Page 2 �� E:\Documnets\Wrightsoft WAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E -�- wrightsoft° Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 QUICK CALCS, INC. Pran: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area DINING 17.0 ft 8.0 ft heat/cool 11.0 x 13.0 ft 143.0 ft2 KITCHEN 17.0 ft 8.0 ft heat/cool 11.0 x 14.0 ft 154.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e .2.glazing,_clClow-e__.. 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e plazino, clr low-e _ - 13A-0ocs 2 glazing, clr low-e 2 glazing, clr low-e 11 DO -__- 13A4ocs 16A30ad��-___-__0032. 22A tph 0.143 0.650 0.650 0:650 0.650 -..-._0.650 0.143 0.650 0.650 0.650 _ - 0.650 0.650 0.650 0.650 -_0.390 0.143 _.- 1.358 n n n n n ._.n-_ a a a a _ _e . s s s -s w _� 4.66 18.20 18.20 18.20 18.20 . _._18.2Q 4.00 18.20 18.20 18.20 18.20 4.20 18:20 18.20 _ _ 10.92 4.00 0.90 38.02 �- 2.19 14.99 14.99 14.99 14:99 _.._-14.99 2.19 30.39 31.52 32.42 32.42 2.99 14.99 14.99 - 10.34 2.19 2.24. 0.00 - 88 0' 0 40 0 _0 48 0 0 15 - - - 0----0 0 0 0 -- --0 0 _ 143_-__143_,____ 143 -- 48 0 0 0 0 0 192 0 0 728 0 _. --0.-----__-0 132 0 0 273 - -- 0.__ 0 0 0 0-----0 0 128 646 105 0 0 600 0 72 0 0 486 -0 0 0 0 0 _,__320,_.-154_�_138 0 0 0 0 0 0 --.-_-- 0 0 0 0 0 __--.- _ 0 86 6 0 _ 48 154 0 0 0 0 0 -�__.._0 0 0 0 0 ._.___0 82 6 0 0 0 0 0 0 -._._w0 0 0 0 0 ... -- 0 109 109 0 192 646 0 0 0 0 0 _.--._ __0: 0 0 0 0 --- --_0 190 90 0 105 ._-- , 33 0 0 1 0 0 0 _ _- 0 0 17 - - - _ W F 48 17 0 6 c)AED excursion -1 -1 Envelope loss/gain 2100 1583 1414 718 12 a) Infiltration b) Room ventilation 239 0 67 0 239 0 67 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1200 Subtotal (lines 6 to 13) 2338 1650 1653 1985 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 5 2344 547 0 0 13 1663 645 23% 39% 0 0 0 1653 386 0 0 0 1985 770 Total room load Air required (cfm) 1108 2891 2309 102 2038 76 2756 121 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsaft' Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 CP. Page 3 E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E - wrightsoftRight-J® Worksheet Job: Entire House Date: MARCH 13, 2018 B : QUICK CALCS, INC. Prim 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area GREAT ROOM 17.0 ft 10.0 ft heat/cool 17.0 x 19.0 ft 323.0 ft2 DEN 24.0 ft 8.0 ft heat/cool 12.0 x 12.0 ft 144.0 ft2 Ty Construction number U-value (Btuh/Wt-°F) Or HTM (Btuhfft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 _ W - 0.143 0.650 0.650 0.650 0.650 --;0.650 0.143 0.650 0.650 0.650 - -0.650 0 0.650650 0.650 ---_0.390 _--0 143 _-0 032 1.358 ' n n n n n -n-. a a a a e- s s s _ s .w _ ; �4.00 18.20 18.20 18.20 18.20 _ 18.20 4.00 18.20 18.20 18.20 --18.20 4. 18.2020 18.20 10.92 � .00 0_90 38.02 2.19 14.99 14.99 14.99 14.99 ----14.99 2.19 30.39 31.52 32.42 32.42 2 19 14.99 14.99 10.34 170 0 0 0 0 ----.-_85 0 0 0 0 - --_0 0 ,- 0 0 0 85 0 0 0 0 •----- 0 0 0 0 0 - - _0 0 0 0 0 339 0 0 0 0 .-----1553 0 0 0 0 - - 0 0 0 0 ---- -0 0 289 646 185 0 0 0 0 -----1279 0 0 0 0 ---- 0 0 0 0 0 0 0 0 0 ------0 16 0 0 0 -- -- 0 96 0 30 0 0 0 0 0 -------- 16 0 0 0 --- --0 66 0 30 0 0 0 0 0 ----0., 64 0 0 0 _.,... -� 0.._.-_ 26 0 0 546 0 0 0 0, 0 -------� 35 0 0 0 0 144 0 450 13A-4ocs 2 glazing, cir low-e "2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazinq,_clr low-e - 13A-4ocs 2,glazing, clr low-e 2 glazing, clr low-e 11D0 �--, 13A-4ocs_ 16A 30ad__- 22A tph ---- W - _. C F _ _2.19 _ _ 2,24 0.00 -� 0 _ ___- 323 323 ------ - _-- .._-0 ----__-323 17 -- - - -._. --.0. --_-_ 724 0 -------0 -__-_80 _- 144 144 ---- -0 80 ._ 144 24 --------0 -_.. -320 -, 129 913 ---0 175 _- _ 323 0 6 c)AED excursion -2 -1 Envelope loss/gain 2828 2186 2236 1126 12 a) Infiltration b) Room ventilation 298 0 84 0 337 0 95 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 900 0 0 0 Subtotal (lines 6 to 13) 3126 3170 2573 1221 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 39%1 0 0 148 3274 764 0 0 102 3272 1270 23% 39% 0 0 289 2862 668 0 0 183 1404 545 Total room load Air required (cfm) 4039 150 4541 200 1 1131 3530 1949 66 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. c -Fk wrightsoft' RightSuite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 ACC ,, E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Cale = MJ8 Front Door faces: E Page 4 + wrightsoft° Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: MARCH 13, 2018 B- Plan: 1801-0601 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area FOYER 5.0 ft 8.0 ft heat/cool 5.0 x 10.0 ft 50.0 ft2 BEDROOM 2 24.0 ft 8.0 ft heat/cool 12.0 x 12.0 ft 144.0 ft2 Ty Construction number U-value (Btuh/Wt - F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 - -- 13AAocs ..-- --- 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e clr low-e_- 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e- __. 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 13A-4ocs --0.143 0,650 0.650 0.650 0.650 -------0.650 0.143 0.650 0.650 0.650 -----0 650 0.143 0.650 0.650 0.143 - n n n n n -n-- a a a a -e_ s s s w , - - 4.00 18.20 18.20 18.20 18.20 ---18.20, 4.00 18.20 18.20 18.20 ---18.20 4.00 18,20 18.20 4 00 0.90 3802 - - 2.19 14.99 14.99 14.99 14.99 _14.99 2.19 30.39 31.52 32.42 ---32.42 2.19 14.99 14.99 . _2.19 --- 2.24 0.00 -- --- 0 0 0 0 0 ----_ 0 0 0 0 0 _.._._ _0 40 0- 0 _ -__ __ _ 0 50' 50 ---_ - 0 0 0 0 0 �,- _0 0 0 0 0 _--. -- _ 9 20 0 0 _ -_ _ - ---50 5 - - - 0 0 0 0 ---_0 0 0 0 0 0 78 0 0 ..._.-_ __ _.0 ------- 45 _190 -- --- - - 0 0 0 0 -_-____0 0 0 0 0 --_.--0 43 0 0 _--- _ ._0 -------112 - - - 0 -- --- 0 0 0 0 -0 16 0 0 0 .-- ---0 96 0 30 __---- -- 80 --- -44 --144 -- Q 0 0 0 0 -- ----0 16 0 0 0 . --- -- -0 66 0 30, ___ _ _.- 80 --- - -144 24 -- - 0 0, 0 0 0 -- -0 64 0 0 0 - -- -_-_ 0 264 0 546 ___ ___.320. ---- 1.29 913 ----6 0 0 0 0 ----_ -Q 35 0 0 0 - 0. 144 0 450 - _ - 175 -----323. _-- 0.. --.2.glazing, __--- _w - --- 6 c)AED excursion 0 -1 Envelope loss/gain 536 3651 2236 1126 12 a) Infiltration b) Room ventilation 70 0 20 0 337 0 95 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 400 Subtotal (lines 6 to 13) 1 606 385 2573 1621 14 15 Less e)dernal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 -606 0 0 0 0 -385 0 0 23% 39% 0 0 66 2639 616 0 0 57 1678 651 Total room load Air required (cfm) 0 0 0 0 3255 121 2328 102 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wrightsoft' Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 ACCA E:\Documnets\WrightsaftHVACkVOSSENRESIDENCE.rup Calc = MJ8 Front Door faces: E Page 5 wrightsoft' RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM Job: Date: MARCH 13, 2018 By: Plan: 1801-0601 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area WIC 3 5.0 ft 8.0 ft heat/cool 6.0 x 5.0 ft 30.0 ft2 WIC 2 11.0 ft 8.0 ft heat/cool 6.0 x 5.0 ft 30.0 ft2 Ty Construction number U-value (Btuhfft22F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 - --- 13A-4ocs ---- 2 glazing, clr low-e 2glazing, clr low-e 2 glazing, clr low-e 2 glazing, cir low-e cir low-e-__ 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2_clazing._clr lower--- 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e _11D0i,--- 13A:4ocs __ __._____ -30ad 22Atph ---- - 0.143 0.650 •0.650 0.650 0.650 __0.650 0.143 0.650 0.650 0.650 --- 0.650 0.143 0.650 0.650 - --- 0.390 _4_-0.143 _ 0,032 1.358 n n n n n -n_ a a a a . e__ s s s s_ w _- _ 4.00 18.20 18.20 18.20 18.20 __ 18.20 4.00 18.20 18.20 18.20 .-_18_.20 4.00 18.20 18.20 --10.92 _-_4_00 0_90' 38.02 ---2.19 14.99 14.99 14.99 14.99 ,_ 14.99 2.19 30.39 31.52 32.42 ___ --- 32.42 2.19 14.99 14.99 _.-_ 10.34 _ _. 2.99 �2_24 0.00 -- -- 0 0 0' 0 0 -- __0 40 0 0 0 Q 0 0- 0 - -- -0 _ _ ___ 30 - - 0 0 0 0 0 _--.-0 40 0 0 0 _-.----0 0 0 0 - -:_._ _-_..__ Q 5 ---.: 0 0 0 0 0 ..--- 0 160 0 0 0 -0 6 0 0 -__.._ -0 --_-__0 27 190 - --.00 0 0 0 0 ------_0 88 0 0 0 -- ---- -9 0 0 0 - - 0 0 0 0 0 .--. -0 40 0 0 0 -- -- 0 0 0 0 0 -- ---0 40 0 0 0 -------9 48 0 0 ---- - 0 0 0 0 0 ---.- �, 160 0 0 0 -- ---.- 4 192 0 0 -- 0 0 0 0 0 ----- 0. 88 0 0 0 --'.2.glazing, --- _ -----0 46 0 0 0 -------0 1-6 0 0 - __- W _ _ F -___ _ _ _-_ Q 67 0 --__ -Q _ �._30 30 ---0 Q _�___30 _ 11 - -- 4 27 418 ---- -0. ---- Q - 0 - - - - - 6 c)AED excursion 0 0 Envelope loss/gain 377 155 797 260 12 a) Infiltration b) Room ventilation 70 0 20 0 154 0 44 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 447 174 952 303 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 0 447 104 0 0 0 174 68 23% 39% 0 0 0 952 222 0 0 0 303 118 Total room load Air required (cfm) 552 21 242 11 1174 44 421 19 Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed. wr'ightsoft• RightSuite� Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 �� E:1Documnets\Wrightsoft HVACIVOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E Page 6 -�- wrightsoft, Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 By - QUICK CALCS, INC. Ptan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area BEDROOOM 3 12.0 ft ;8.0 ft heat/cool 12.0 x 12.0 ft 144.0 ft' BATH 2 0 ft 8.0 ft heat/cool 6.0 x 8.0 ft 48.0 ft' Ty Construction number U-value (Btuh/ft' °F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 1 13A-4ocs 2glazing, cir low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e -2,glazing, clr low-e_-_ 13A.4ocs 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir low-e 2glazinq. clrlow-e _- 13A-4ocs 2 glazing, clr low-e ' 2 glazing, clr low-e 11 D0 -- --- _, 13A=4ocs. - .16A-30ad_._ -, 22A-tph - 0.143 0.650 0.650 0.650 0.650 -_ ----0.650 0.143 0.650 0.650 0.650 .----_0.650 0.143 0.650 0.650 -.__0.390 _ 0.143 - OA32 1.358 --� - n n n n _n__ a a a a _ e----_--_1_8.20__.__32.42 s s s s- _ w . '_ __ -- --4.00 18.20 18.20 18.20 18.20 18.2Q 4.00 18.20 18.20 18.20 4.00 18.20 18.20 -_ 10_92_ -_4,00- f 0_90 38.02 2.19 `14.99 14.99 14.99 14.99 -. 14.99 2.16 30.39 31.52 32.42 2.19 14.99 14.99 10.34 2.19 _ -_2 24 0.00 --- -- -0 0 0 0 0 __--_0 96 0 0 0 _----_-20- 0 0 0 -- --- 0 0 0 0 0 _-- --__0 76 0 0 0 __-. 1 0 0 - -- - -0 --.�__- 0 144 12 ---- -- � 0 0 0 0 -__-_ -- 304 0 0 0 . ---- -364 0 0 -- - 0 .___.__... _0 129 456 ---0 0 0 0 0 ___-_Q 166 0 0 0 ----- 648 0 0 - - - 0 _ .__-- 323 0 0 0 0 0 0 .----__-0 0 0 0 0 -- ---_ _ 0 0 0 --- 0 ---Q ._,_ _48 48 _...-- --- � 0 0 0 0 ------__ 0 0 0 0 0 0 _ . 0'- 0 0 - --0 0 i _ 48 0 ------ -0---- 0 0 0 0 -' 0 0 0 0 0 --- Q 0 0 0 0 _ 0 _ _ 0 0 0 - - 0 o 108_ 0 _-- _ ---Q 0 0 0 0 _ 0 0 0 0 -- ---- -0 2 43 0 w --- -0 __--�0 144 144 F 6 c)AED excursion 10 0 Envelope loss/gain 1254 1148 43 107 12 a) Infiltration b) Room ventilation 168 0 47 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 400 0 0 0 Subtotal (lines 6 to 13) 1422 1595 43 107 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 1 23% 39% 0 0 5 1427 333 0 0 13 1609 624 23% 39% 0 0 124 167 39 0 0 94 201 78 Total room load Air required (cm) 1761 66 22W 98 205 8 279 12 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 'Of+- wrightsaft' ACCA RightSuite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 Page 7 E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E wrightsoft® Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 By QUICK CALCS, INC. Pfan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Eposed wall Room height Room dimensions Room area HALL 0 ft 8.0 ft heat/cool 6.0 x 4.0 ft 24.0 ft2 MASTER BATH 9.0 ft 8.0 ft heat/cool 1.0 x 158.0 ft 158.0 ft2 Ty Construction number U-value (Btuh/f?-°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 2 glazing, clr lower 2 glazing, cIr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2,glazing,_clr low_e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq, clr low-e 13A-4o- cs- - -- 2 glazing, clr low-e 2 glazing, clr low•e 13A4ocs- _16A30ad_._�_._�__ 22A tph __.-__ 0.143 0.650 0.650 0.650 0.650 ___0.650 0.143 0.650 0.650 0.650 0.650 0.143 0.650 0.650 - 0.143 1.358 _-__ n n n n n n_ a a a a e s s s _w r___ �_ 4.00 18.20 18.20 18.20 18.20 _ 18.20: 4.00 18.20 18.20 18.20 _ 18.20 4.00 18:20 18.20 . -- 4.00 38.02 _.__-_ 2.19 14.99 14.99 14.99 14.99 14.99 2.19 30.39 31.52 32.42 _ 32.42 2.19 14.99 14.99 --_ 2.19 -.-- 2.24 0.00 -�_._-_ 0 0 0 0 0- -_. _-_,0 0 0 0 0 0 _ -0 0 0 -- - _24 24 __--...__ 0 0 0 0 0 '_0 0 0 0 0 0 - - 0 0 0 - .---_- 24 0 ... _ _.____ 0 0 0 0 0 -_� -_0 0 0 0 0 0 - --- 0 0 0 - - 0 ._-- 22 0 . __._-__- . 0 0 0 0 0 _____0 0 0 0 0 0 -- - 0 0 0 - -- - 0 ____ 54 0 ---- --._-- 0 0 0 0 0 -__----_ 0 0 0 0 0 _ _0 66 0 1 0 0 - --- - 0 0 0 9 __.-_--o 0 0 0 0 0 _ _Q0- 264 0 109 0 0 0 0 0 342 _-------. 0 0. 0 0 0 144 0 189 0 0 - - -- 0 0 0 0 ___0 72 0 6 0 0 -- -- 0 0 0 - - _ __jM 158 W - - F 6 c)AED excursion 0 0 Envelope loss/gain 22 54 857 687 12 a) Infiltration b) Room ventilation 0 0 0 0 126 0 36 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 22 '54 984 723 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 -22 0 0 0 0 -54 0 0 23% 39% 0 0 0 984 230 0 0 0 723 280 Total room load Air required (cfm) 1 7 0 0 0 1 0 1213 45 1003 44 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 �� Page 8 E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E wrightsoft Right-M) Worksheet Job: Entire House Date: MARCH 13, 2018 QUICK CALCS, INC. Pran: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M TOILET M WIC 1 2 Fposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x ' 46.0 ft 4.0 x 8.0 ft 5 Room area 46.0 ft2 32.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 --- 13A flocs - --- -- 2 glazing, clr low-e 2 glazing, clr low-e --- 0.143 0.650 0.650 ---� - n n --- 4.00 18.20 18.20 - 2.19 14.99 14.99 -0 0 0 -- - Q 0 0 - - 0 0 0 - ---- 0 0 0 -- - 0 0 0 - - - -0 0 6 - - -0 0 0 -- - 0 0 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2.glazing,.clr low?__-- 13A-4ocs - -0.650 0.143 _ n_ a _ _ 18.20 4.00 --14.99 2.19 --_--0 0 ._- _-_0 0 --0 0 ..--- _ 0 0 - - __--- -0 64 0 64 ,- 0.. 256 - _0 140 --- _ 2 glazing, clr low-e 0.650 a 18.20 30.39 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 31.52 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 a 18.20 32.42 0 0 0 0 0 0 0 0 2 glazinq, clr - low-e - - 0.650 a 18.20 32.42 0 0 0 0 0 0 0 0 13A-4ocs 0.148 -s-- ---- ---4.00 2.19 - 0 6 ---- ----6 -- - - -- 0 - ----0 --- - -0 -- - 6 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 11D0- --- - 0.650 -- - 0.390 s 18.20 -. _ 10.92 14.99 --10,34 , 0 - 0 ---- 0 -- -- 0 - ---- 0 - ---0 0 --- 0 0 - ----� 0 ---- - W --s- w 13XZ-m 16A30ad. 0.143 4.00 2.19 0 0 0 0 0 0 _ 0 0 F 22A-tph - 1.358 38.02 0.00 46 0 0 0 32 8 304 0 6 c) AED excursion 0 0 Envelope loss/gain 41 103 589 212 12 a) Infiltration 0 0 112 32 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 41 103 701 243 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 5 46 0 12 115 0 0 701 0 0 243 15 Duct loads 1 23% 39% 11 45 23% 39% 164 94 Total room load Air required (cfm) 57 2 160 7 865 32 338 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 .4C�A E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E Page 9 - wrightsofr Right-J® Worksheet Job: Entire House Date: MARCH 13, 2018 By: QUICK CALCS, INC. Plan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name EVosed wall Room height Room dimensions Room area M W IC 2 O ft 8.0 ft heat/cool 5.0 x 8.0 ft 40.0 ft2 M HALL O ft 8.0 ft heat/cool 5.0 x 4.0 ft 20.0 ft2 Ty Construction number U-value (Btuh/f?-°F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -- - - 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2.glazing, clr lower- 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2glazinq, clr low e___ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11DO ___ __ �_ 13A-4acs----- 16A-30ad_. _??AAph 0.143 0.650 0.650 0.650 0.650 --------0.650 0.143 0.650 0.650 0.650 _ _ _ 0.650 - - 0.143 0.650 0.650 ._. _ Q390 0.143 032 1.358 n n n n n __n_ a a a a e- s s s _ s_- _ w_ ._r..4 4.00 18.20 18.20 18.20 18.20 -. 18.20 4.00 18.20 18.20 18.20 --- _18.20 4.00 18.20 18.20 --_10.92 .. 4.00 __. _ 0.60 38.02 - 2.19 14.99 14.99 14.99 14:99 -_14.9.9 2.19 30.39 31.52 32.42 32.42 -- _ 2.19 14.99 14.99 --_ 10.34 _ 2.19 _ __.2 24 0.00 0_0 0 0 0 D -__-_0. 0 0 0 0 -_-- -- 0 0 0 0 .---__ - 0 0 . ._,4� 40 0 0 0 0 --...--- 0 0 0 0 0 -._.- -- 0 0 0 0 _--_._.-._.0 _ 0 _ : _ 40 0 0 0 0 0 -- _-_0 0 0 0 0 .-__ ..--0 0 0 0 --_ -.-._0-_ 0 _ ._.__._?6 0 0 0 0 0 _ ---- -0 0 0 0 0 -----._ 0 0 0 0 --- _ _-_0 _ _.__. � 6 0 0 0 0 -----0 0 0 0 0 -- 0 - - 0 0 0 -- 0 ..- ._ _ 29 20 0 0 0 0 --. -Q 0 0 0 0 _ _ 0 -._ 0 0 0 � 0 0 0 0 _._.__--0- 0 0 0 0 __-- 0 _ - 6 0, 0 0 0 0 0 -------0. 0 0 0 0 - -- -- 4. 0 0 0 ------ Q -.-- 0 _ : -- _ --- W ,C F --__--0 _._ .20 6 _---_-0. ----- -- -0 _-.___ 1$: 0 6 c)AED excursion 0 0 Envelope loss/gain 36 90 18 45 12 a) Infiltration b) Room ventilation 0 0 0 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 36 90 18 45 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 23% 39% 0 0 4 40 9 0 0 10 99 39 23% 39% 0 0 18 0 0 0 0 -45 0 0 Total room load Air required (cfm) 49 2 138 61 0 01 0 0 Calculations approved byACCA to meet all reauirements of Manual J 8th Ed. -*- wrightsaft' RightSuite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 Page 10 E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E -�- wrightsoft° Right-M Worksheet Job: Entire House Date: MARCH 13, 2018 ISy QUICK CALCS, INC. Plan: 1801-0601 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area MASTER BEDROOM 48.0 ft 9.0 ft heat/cool 1.0 x 261.0 ft 261.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ----- --- --- -- --- 13A�ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2,glazing,_clrlow_e_- 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazino. clr-low_.e _-- glazing, clr low-e 2 glazing, clr low-e 13A-4ocs-- . _ 22A-tph - --- - 0.143 0.650 0.650 0.650 0.650 -�0.650 0.143 0.650 0.650 0.650 _ ---- 0.650 0.143 0.650 0.650 0.143 1.358 ----- n - n n n n __n a a a a ._ e_- s s s - w _ -- - .-- 4.00 18.20 18.20 18.20 18.20 _ 18.20-_---- 4.00 18.20 18.20 18.20 _-. 18.20 4.00 18.20 18.20 INK - 4.00 38.02 - ----- 2.19 14.99 14.99 14.99 14.99 2.19 30.39 31.52 32.42 _ 32.42 2.19 14.99 14.99 -- 10.34 2.19 ----2.24 0.00 ---- 162 20 15 0 0 -- - -- 127 - 0 0 0 0 118 1 0 0 _- _-... _ 0 0 0 0 - - --509 364 273 0 0 472 146 0 0 02 0 0 -- _ -0 - --577 ------ 234 1825 ---- 278 300 225 0 0 258 243 0 0 0 0 - -- 0 -- -315- _ - 85 0 ------ ---- _ -- ----- -- - --- - -- ------- - -- -- - - -- ------ - _ 126 8 0 0 - - -- 0 0 0 0 - -.-_.Q - --144 __._- _ 261 261 -- . h13A-4ocs W - F --- 144 -- -261 46 - 6 c)AED excursion 3 Envelope loss/gain 4399 2201 12 a) Infiltration b) Room ventilation 758 0 214 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1900 Subtotal (lines 6 to 13) 5157 4315 14 151 Less external load Less transfer Redistribution Subtotal Duct loads 123% 39% 0 0 5 5162 1205 0 0 12 4327 1679 Total room load Air required (cfm) 6367 237 6006 264 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -F' wrightsaft' Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Mar-13 11:00:00 .4CC:A E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E Page 11 �d- wrightsoft" Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM For: VOSSEN RESIDENCE, SOUTHERN CITY DEVELOPMENT 5817 SILVER OAK DRIVE, FORT PIERCE, FL 34982 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1180 cfm Job: Date: MARCH 13, 2018 By: Plan: 1801-0601 Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1180 cfm 221 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 C 279 8 12 1.000 4.0 Ox 0 VIFx 48.7 135.0 st4 BEDROOM 2 h 3255 121 102 1.000 7.0 Ox0 VIFx 61.9 155.0 sty BEDROOOM 3 c 2233 66 98 1.000 7.0 Ox0 VIFx 53.4 135.0 st4 DEN h 3530 131 86 1.000 7.0 Ox0 VIFx 53.3 135.0 st4 DINING h 2891 108 102 1.000 7.0 Ox0 VIFx 20.2 115.0 st2 GREAT ROOM c 2271 75 100 1.000 7.0 Ox 0 VIFx 48.0 115.0 st1 GREAT ROOM -A c 2271 75 100 1.000 7.0 Ox 0 VIFx 47.4 135.0 st4 KITCHEN c 2756 76 121 1.000 7.0 Ox 0 VIFx 24.6 115.0 st2 M TOILET c 160 2 7 1.000 4.0 Ox0 VIFx 49.4 115.0 st1 M Wlc 1 h 865 32 15 1.000 4.0 Ox0 VIFx 56.0 135.0 st3 MWIC 2 c 138 2 6 1.000 4.0 Ox0 VIFx 50.6 115.0 st1 MASTER BATH h 1213 45 44 1.000 5.0 Ox0 VIFx 58.0 135.0 st3 MASTER BEDROOM C 3003 118 132 1.000 7.0 Ox 0 VIFx 50.6 115.0 st1 MASTER BEDROOM -A c 3003 118 132 1.000 7.0 Ox 0 VIFx 59.4 135.0 st3 MUD ROOM h 2695 100 68 1.000 6.0 Ox0 VIFx 22.4 115.0 st2 UTILITY h 1015 38 25 1.000 5.0 Ox 0 VIFx 20.5 115.0 st2 WIC h 1174 44 19 1.000 5.0 Ox0 VIFx 66.3 155.0 st5 WIC 3 h 552 21 11 1.000 4.0 Ox0 VIFx 62.9 155.0 sty wri htsoft® 2018-Mar-1311:00:02 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 A E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 185 132 1.000 531 8.0 0 x 0 VinlFlx st4 st1 Peak AVF 393 436 1.000 800 10.0 0 x 0 VinlFlx st3 Peak AVF 196 191 1.000 561 8.0 0 x 0 VinlFlx st1 st4 Peak AVF 465 428 1.000 705 11.0 0 x 0 VinlFlx st2 st2 Peak AVF 787 744 1.000 853 13.0 0 x 0 VinlFlx Name Grill Size (in) Htg (cfm) Clg (cfm) TEL M Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1180 1180 0 0 0 0 Ox 0 VIFx wri htsoft9 2018-Mar-1311:00:02 Z. 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 2 CA E:\Documnets\Wrightsoft HVAC\VOSSEN RESIDENCE.rup Calc = MJ8 Front Door faces: E