Loading...
HomeMy WebLinkAboutTRUSS"SCOSTA CORPORATION 3670 Commerce Center Drive Sebring, Florid , 33870RECEIVED 863-385-8242 Voice 863-385-8724 Fax WWW.SC0,STAC0RP.00I0 MAR 19 2018 ST. Lucie COUtityj ParMittIng fob Information: Contractor. SOUTHERN CITY DEVELOPMENT INC Job Name: VOSSENICOD Engineering Cover Sheet Job #: 84828 Date: 12/21/2017 3:16:04 PM Address: — — — — SILVER OAK DR. FT. PIERCE FL 34982 L. Truss designs meet the criteria of FBC 2010 and/or FBC 2014 (5th edition) Gravity - Roof (psi): TC LL 20 TC DL 7 BC DL 10 BC LL 0 Total: 37 Wind: ASCE 7-10 170 MPH Exposure: B -Closed Risk Category: Residential - CAT II DL TO RESIST WIND TC 4.00 BC 6.00 Gravity - Floor (psi): TC LL 0 TC DL 0 BC DL 0 BC LL 0 Total: 0 The following truss designs have been prepared with Alpine/ITW proprietary software, and reviewed by Richard A. Siver P.E. Florida Registered Engineer # 65698. This cover sheep is sealed in lieu of each individual sheet in accordance with 61G15-31.003, FAC Standard detail sheets and or sealed engineering sheets by Alpine</ITW at added to those listed below. The details are believed to be correct to the best of this engineer's knowledge, and the accuracy of the information provided by others cannot be guaranteed. Note the seal on this index sheet indicates acceptance of professional engineering responsibility as the truss design engineer solely for the Truss Design Drawings listed below. The suitability and use of each component for any particular building is the responsibility of the Building Designer, per ANSI/TPI I Section 2. The Identity of the structural Engineer of Record has not been provided as of the seal date. �8__ CAN N E D BY Ot Lucie County Order ID Date Order ID Date 1 133 12/21/2017 2 134 12/21/2017 3 B5 12/21/2017 4 B2 12/21/2017 5 A14 12/21/2017 6 A15 12/21/2017 7 I A13 12/21/2017 8 A16 12/21/2017 9 Al2 ':2/21 /2017 10 All 12/21/2017 11 A10 12/21/2017 12 A9 12/21/2017 13 A17 12/21/2017 14 A18 12/21/2017 15 A19 12/21/2017 16 A20 12/21/2017 17 A21 12/21/2017 18 A22 12/21/2017 19 C3 12/21/2017 20 C2 12/21/2017 21 D5 12/21/2017 22 Cl 12/21/2017 23 A8 12/21/2017 24 A7 12/21/2017 25 A6 '12/21/2017 26 A5 12/21/2017 27 D4 12/21/2017 28 D3 12/21/2017 29 D2 12/21/2017 30 D1 12/21/2017 31 A2 12/21/2017 32 Al 12/21/2017 33 A4 12/21/2017 34 A3 12/21/2017 35 I B1 12121/2017 36 B6 12/21/2017 I 37 V7 't2/21/2017 38 V9 12/21/2017 39 E1 12/21/2017 40 V8 12/21/2017 41 V10 12/21/2017 42 M1 12/21/2017 43 M3 12/21/2017 44 M2 12/21/2017 45 C1':: 12/21/2017 46 CJ10' 12/21/2017 47 CJSA 12/21/2017 48 CJSB 12/21/201 49 {� / 51 J64 12/'Z,1/2017 52 I EJ4E3 ! I .` If a digital seal is affixed to this dociment, printed copies without original signature must be verified using the o9&al:electro "i°cg 5C_ E"aMa""RS Page 1 of 2 APP 0 N 0 3 2QiQ �nl�-3k 77737 J`nb #: 84828 Date: 12/21/2017 3:16:04 PM d Order ID Date Order ID Date 53 EAC 12/21/2017 54 EA 12/21/2017 55 EJ4A 12/21/2017 56 AA 12/21/2017 57 J4 12/21/2017 58 EAD 12/21/2017 59 J3 12/21/2017 60 EA 12/21/2017 61 J2 12/21/2017 62 J2A 12/21/2017 63 V6 12/21/2017 64 V5 12/21/2017 65 V4 12/21/2017 66 V3 12/21/2017 67 V2 12/21/2017 68 V1 12/21/2017 If a digital seal Is affixed to this document, printed copies without original signature must be verified using the original electronic version SQEngMasterRS Page 2 of 2 ' Job iJumber: 84828 Ply: 1 SEQN: 26091 / T12 / COMN /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 2 FROM: DRW: Truss Label: B3 Wgt: 205.8 Ibs ... / ... 12/21 /2017 T T 1 4. 18, I' 17'8-1/4'• L 17,8" 171-12" 2- #— 62-1/4• ---I-- 65-3i4" --}-2' i-r—{ Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 B Mea Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.57 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T1 2x4 SP #2: Bot chord 2x4 SP #2 :B5, B6 2x4 SP M-31: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: :Rt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 byALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right cantilever is exposed to wind 18'4-114" Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0,038 M 999 360 B 499 / 197 / 235 /- / 329 / 8.0 Lu: NA Cs: NA VERT(TL): 0.121 M 999 240 J 2021 / 392 / 1245 / - / - / 8.0 Snow Duration: NA HORZ(LL): 0.024 J - - Q 637 / 240 / 503 / - / - / 4.5 HORZ(TL): 0.073 J B / 163 Code / Misc Criteria Creep Factor: 1.5 Wind reactions based on MWFRS Bldg Code: FBC 2014 RES Max TC CSI: 0.949 B Min Brg Width Req = 1.5 TPI Std: 2007 Max BC CSI: 0.373 J Min Brg Width Req = 1.7 Rep Factors Used: Yes Max Web CSI: 0.727 Q Min Brg Width Req = 1.5 FT/RT:20(0)/10(0) Mfg Specified Camber: Bearings B, J. & Q are a rigid surface. Plate Type(s): WAVE, HS VIEW Ver: 17.02.01A.1114.21 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 60 0 D-E 812 -92 B - C 124 -171 E - F 392 - 478 C- D 893 -147 F- G 56 0 RICHARD A. SIVER P.E. #65698 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS guire extreme care in. fabriyV.ting handling, shipping, installing. and bracing._ Refer to and follow the latest :sua8n or wens snau nave Dracing instauea per ts� as shown above and on the Join Details, unless a division of ITW Buildin Components G conformance with ANSI PI 1, or for har this drawin indicates acceptance f ;e of this gnawing for any structure gs Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B-N 160 -113 K-J 521 -851 N - M 206 - 244 J - 1 329 - 253 M - L 86 -191 I - H 329 - 253 M - C 178 - 69 H - F 562 - 482 L-K 84 -193 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A-0 3 0 J -D 325 -1120 L-C 307 0 J-E 515 -833 C- K 529 - 774 E- H 405 0 K-D 101 -66 P-G 3 0 of failure to build the 3670 COMMEI 1 or cover pa e SEBRI ,n. The sui9ability (86$ Job Plumber: 84828 Ply: 1 SEQN: 26093 / T19 / COMN /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 2 FROM: DRW: Truss Label: B4 Wgt: 196.0 Ibs .. / ... 12/2112017 ` 1 7'8" 6--2' -{-67-114• 65-3i4'--)-2, I- 2' —1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h!2 to h Spacing: 24.0 " C&C Dist a: 3.52 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T1 2x4 SP #2: Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design va!ues approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 800,S length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Plating Notes (++) - This plate works for both joints covered. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Dr6X12 35'2' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.055 M 999 360 B 546 / 188 / 276 /- / 303 / 8.0 Lu: NA Cs: NA VERT(TL): 0.184 M 999 240 J 2015 / 413 / 1163 / - / - / 8.0 Snow Duration: NA HORZ(LL): 0.034 G - - P 432 / 174 / 328 / - / - / 8.0 HORZ(TL): 0.114 J B / 244 Code / Misc Criteria Creep Factor: 1.5 Wind reactions based on MWFRS Bldg Code: FBC 2014 RES Max TC CSI: 0.935 B Min Brg Width Req = 1.5 TPI Std: 2007 Max BC CSI: 0.863 J Min Brg Width Req = 2.4 Rep Factors Used: Yes Max Web CSI: 0.731 P Min Brg Width Req = 1.5 FT/RT:20(0)/10(0) Mfg Specified Camber: Bearings B, J, & P are a rigid surface. Plate Type(s): WAVE, HS VIEW Ver: 17.02 011A 1114 21 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 60 0 D-E 791 -15 B - C 125 - 236 E - F 318 - 446 C - D 868 - 57 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - N 170 - 80 K - J 435 - 830 N-M 219 -244 J-1 316 -214 M-L 145 -236 I-H 316 -214 M-C 136 -27 H-G 319 -212 L - K 142 - 238 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A-O 3 0 J-D 374 -11;. L- C 308 0 J- E 540 - 869 C- K 532 - 779 E- H 411 0 K - D 136 - 86 F - G 317 - 357 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme are in fabricating handling, sh! ping, installing and bracing. Refer to and follow the latest edition of f Safety Information, b TPI and SBCA) for safety practices prior to performing these functions. Installers shall prov BCSI. Unless noted o herwise,too chard shall have properly attached structural sheathingg and bottom chord shall I did ceiling Locations she wn fur p'e manent lateral restraint of webs shall have brac!n insjalled per BCSI sections ! 'le. Apply plates to each face of truss and position as shown above and on the Joint9Deteil., unless noted otherw 60A-Z for standard plate positions. a division of TPI 1, or fort acceptance any sructure this drawing,any failure to build the 3670 COMMERCE CENTER on this drawing or cover pa e SEBRING, FL 33870 he design shown. The sui[ability (863)385-8242 Job Dumber: 84828 Ply: 1 SEQN: 27187 / T1 / COMN SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG City: 1 FROM: DRW: Truss Label: 35 Wgt: 172.2 Ibs I .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0 0C• BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 18' 17'8" Wind Criteria Wind Sid: ASCE 7-10 Speed: 170 mph Enclosure: Closed 'Risk Category: II EXP: B . Mean height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.52 ft Loc. from endwall: not in 9.00 It GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T1 2x4 SP #2: Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Rt Stub Wedge 2x4 SP #2: :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 byALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC 17'2" 17'6" 35'2" Snow Criteria (Pg.Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in Ioc Udefl U# Pf. NA Ce: NA VERT(LL): 0.025 K 999 360 Lu: NA Cs: NA VERT(TL): 0.062 K 999 240 Snow Duration: NA HORZ(LL): 0.015 K - - HORZ(TL): 0.038 K - Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.963 TPI Std: 2007 Max BC CSI: 0.797 Rep Factors Used: Yes Max Web CSI: 0.978 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE, HS VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 T 01H0308(Gl) N ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 743 / 225 / 449 / - / 303 / 8.0 M 1539 / 354 / 824 / - / - / 8.0 N 570 / 166 / 398 /- / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 M Min Brg Width Req = 1.8 N Min Brg Width Req = 1.5 Bearings B, M, & N are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) . Chords Tens.Comp. Chords Tens. Comp A- B 60 0 D- E 309 - 27 B - C 415 - 753 E - F 439 725 C - D 308 - 84 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 587 - 260 I - H 560 - 250 K - J 583 - 262 H - G 560 - 250 J - 1 583 - 262 G - F 563 - 249 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A- L 3 0 D- 1 247 - 567 K- C 384 0 I- E 532 - 806 C- 1 542 - 849 E- G 363 0 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS reqquire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nenf Safety. Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperl G riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 1310.1SCOSTA CORPORATION cable. Apply plates to each ,ace of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to WOOD STEEL OR TIMBER is 160A-Z fOr S Oates plate positions. ROOF OR FLOOR TRUSSES a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI] 1, or for handlinj shipping, installation and bracing of trussesA seal on this drawing or cover page , , SEBRING, FL 33870 this drawing indicates acceRtance i f pro essrona engineering responsibility solely for the design shown. The suifabrlrty (863)385-e242 e of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Job dumber: 84828 Ply: 1 SEQN: 26927 / T57 / COMN /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG City: 1 FROM: DRW: Truss Label: B2 Wgt: 260.4 Ibs .. / ... 12/21/2017 i 15'4" 915-11/16" -F 10,10-9116"-�� 15'6" 1 22 1 4� 17'8" } 17'8-12" 3 V" r"+-2'6'2.1/4- 65-3/4'-+2' -i- 18'4-1/4' 2'-I i-2­1 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 D Des d:: Mean Height: 15.00 ft .00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.57 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T3. T6 2x4 SP M-31: Bot chord 2x4 SP #2 :B3 2x4 SP M-31: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: :Rt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 pif at 18.00 TC: From 28 plf at 18.00 to 28 plf at 33.50 TC: From 56 pif at 33.50 to 56 plf at 37.82 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 0.67 BC: From 22 plf at 0.67 to 22 plf at 9.02 BC: From 20 plf at 9.02 to 20 plf at 15.33 BC: From 22 plf at 15.33 to 22 pif, at 17.33 BC: From 10 plf at 17.33 to 10 plf at 33.47 BC: From 20 plf at 33.47 to 20 plf at 35.69 BC: From 22 plf at 37.69 to 22 plf at 37.82 PLB: From 20 plf at -1.96 to 20 pif at -0.10 PLB: From 20 pif at 35.79 to 20 pif at 27.64 TC: 6 lb Conc. Load at 19.44,21.44,23.44,25.44 27.44,29.44,31.44 TC: 17 lb Conc. Load at 33.47. BC: 30 lb Conc. Load at 19.44,21.44,23.44,25.44 27.44,29.44,31.44 BC: 70 lb Conc. Load at 33.47 Wind Right cantilever is exposed to wind Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Sid: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.059 W 999 36 VERT(TL): 0.154 W 999 24 HORZ(LL): 0.034 Q - - HORZ(TL): 0.085 Q Creep Factor: 1.5 Max TC CSI: 0.850 Max BC CSI: 0.764 Max Web CSI: 0.650 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 559 /204 /- /- /- /8.0 U 1695 / 502 / - / - / - / 8.0 AA 611 /295 /- /- /- /4.5 B / 306 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 U Min Brg Width Req = 2.0 AA Min Brg Width Req = 1.5 Bearings B, U. & AA are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 60 - 26 1- K 0 - 657 B - C 122 - 255 J - M 431 - 54 C- D 628 -110 K- L 0 - 654 D - G 571 - 96 L - M 77 - 847 E - F 405 -122 M - N 193 - 644 F - H 313 -77 N - O 254 -444 G - J 596 -123 O - P 56 - 25 H - 1 517 - 259 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - X 184 - 75 U - T 423 - 90 X-W 105 -61 T-S 625 -190 W - V 107 - 94 S - R 625 -190 W-C 118 0 R-Q 339 -189 V - E 107 - 94 Q - O 600 - 359 E - U 225 -1029 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A-Y 3 0 I-T 274 0 V- C 294 0 T- L 104 - 236 C-E 179 -645 J-K 132 0 D- E 134 - 278 L- R 123 0 U- F 364 - 924 R- N 413 0 U - 1 243 - 927 Q - N 110 - 27 G- H 205 - 620 Z- P 3 0 H - J 222 - 361 ""'IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ing, installing and bracing.Refer to and follow the latest edition of BCSI (Buildin( t Safety Inforiaution, by TPI and'SBCA) for safe�y practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted o,heiwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper; j�id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 SCOSTA C - RPORATION ile. Apply plates to eacri face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to WOOD STEEL OR TIMBER 60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES vision of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , SEBRING, FL 33B70 drawing indicates acce tance of professiona engineering responsibility solely for the design shown. The suigability (863)385-8242 �f this drawing, for any a rructure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. Job Number: 84828 Ply: 1 SEQN: 26913 / T76 /HIPS /SOUTHERN CITY. DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A14 Wgt: 229.6 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 16.071 TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h .C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft G'pi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T3, T4 2x4 SP #2: Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 byALSC Bracing (b) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. (a) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind End verticals not exposed to wind pressure. 16'2-12" 1s'242" 19,5•• Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Sid: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.059 1 999 360 VERT(TL): 0.1381 999 240 HORZ(LL): -0.075 D - - HORZ(TL):-0.172 E Creep Factor: 1.5 Max TC CSI: 0.516 Max BC CSI: 0.907 Max Web CSI: 0.767 Mfg Specified Camber: VIEW Ver: 17.02. 01 A. 1114.21 RICHARD A. SIVER P.E. #65698 127' ♦ Maximum Reactions (Ibs) Loc R /U /Rw !Rh /RL /W 0 1216 /91 /642 /- /247 /8.0 P 1205 / 89 / 627 ! - / - / B.0 Wind reactions based on MWFRS 0 Min Brg Width Req = 8.0 P Min Brg Width Req = 1.5 Bearings O & P are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 727 -1575 D - E 752 -1329 B-C 711 -1214 E-F 560 -1145 C - D 743 -1129 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Con•,,7 N - M 429 - 462 K - 1 1113 - 384 M-L 1331 -551 J-H 23 -3 L-K 1331 -551 H-G 16 -14 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A-N 621 -1144 D-1 231 -114 A-M 1392 -519 I-J 93 0 N - 0 585 -1215 I - E 208 - 79 M - B 217 - 94 I - H 979 - 407 B - K 343 - 436 E - H 399 - 607 C - K 696 - 416 H - F 1078 - 432 K-D 319 -380 F-G 613 -1151 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAINING TO ALL CONTRACTORS INCLUDING THE INSTALLERS qquire extreme care in fabricating, handling, shi ping, installing and bracing., Refer to and follow the latest edition of BCSI (Buildini it Safety. Information, by TPI'and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. r BCSI. Unless noted olherMse,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erl ggid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or �10 SCOSTA CORPORATION ale. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to 60A-Z for standard plate positions. WOOD STEEL OR TIMBER ROOF A FLOOR TRUSSES ivision of ITW Buildin$Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the iformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or 3670 COMMERCE CENTER DRIVE cover pa a . drawing indicates acceptance of profess one engineering responsibility solely for the design shown. The suigabiirty 3f this �awing for any structure is the responsibility of the guliding Designer Der ANSI/TPI 1 Sec.2. SEBRING, FL 33870 (963)385-8242 Job Number: 84828 Ply: 1 1 SEQN: 27027 / T81 / HIPS /SOUTHERN CITY DEVELOPMENT A1OSSEN/COD /BLG City: 1 FROM: DRW: Truss Label:. I'd5 Wgt:240.8Ibs I ... / ... 12/21/2017 r Loading Criteria (psq Wind Criteria TCLL: 20.00 Wind Std: ASCE 7.10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.U0 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.97 ft NCBCLL: 10.00 TCDL: 4.6 psf Soffit: 10.00 BCDL:6.0'psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T1 2x4 SP M-31: Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. £0% length of web member. Attach with 8d Box or Gun (0. 1 13"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. Right cantilever is exposed to wind 14'10 isxs r3 C 0-15xs Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.136 K 999 360 Lu: NA Cs: NA VERT(TL): 0.512 K 692 240 Snow Duration: NA HORZ(LL): -0.166 E - - HORZ(TL): -0.390 E Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.874 TPI Std: 2007 Max BC CSI: 0.840 Rep Factors Used: Yes Max Web CSI: 0.973 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! , "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating,handling, ship pmg, installing and bracing. Refer to and follow the latest Componentt Safety. Information, b TPI anc: for safety practices prior to performing these functions. Installers bracing per BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom cl attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI as applicabgle. App�y plates to each face of truss and position as shown above and on the Joint -Details, unless no drawings 160A-Z for standard plate positions. Alpine, a division of ITW Buildingg�Components Group Inc. shall not be responsible for any deviation from this drawir truss in conformance with ANSI PI 1, or for handling shippin , installation and bracing of trussesA seal on this di "stingthis drawingg indicates acceptance of rofessiona engmeenn responsibility solely for the design and use of this drawing for any structure 61he responsibility of the Building Designer per ANSI/TPI 1 Sec, 13' ■l ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W R 1124 / 90 1608 / - / 240 / 8.0 1 1300 / 88 / 730 / - /- / 8.0 Wind reactions based on MWFRS R Min Brg Width Req = 8.0 I Min Brg Width Req = 1.5 Bearings R & I are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 678 -1422 D - E 691 - 9�a B - C 701 -1080 E - F 638 -1077 C - D 696 - 874 F - G 174 - 37 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp Q - P 415 - 449 M - K 865 - 272 P - 0 1191 - 502 L - J 64 - 39 O - N 1191 - 502 J -1 617 - 263 N-M 874 -281 I-H 9 -14 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A - Q 594 -1050 K - E 103 - 86 A - P 1239 - 461 K - J 583 - 226 Q - R 561 -1123 K - F 384 - 90 P-B 249 -79 J -F 156 -18 B - N 312 - 505 F - I 640 -1299 C-N 313 -106 I-G 214 -141 M - D 255 - 203 G - H 56 - 54 K - L 107 0 of failure to buildthe tthe 3570 COMMERCE CENTER n r The rsuaTabili SEBRING, FL 33870 ty (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 26911 / T75 / HIPS /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: Ala Wgt: 236.6 Ibs .. / .., 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " T M 0 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.57 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013j Top chord 2x4 SP M-31 :T3, T4 2x4 SP #2: Bot chord 2x4 SP M-31 :B2 2x4 SP #2: Webs 2x4 SP #2 Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0. 1 13"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. 1 19'5" 4'7" 32' 132-12" �I 5'11-1/4" {� 67-3/4" �{ Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.056 B 999 360 Lu: NA Cs: NA VERT(TL): 0.131 B 999 240 Snow Duration: NA HORZ(LL): -0.063 B - - HORZ(TL):-0.147 E - - Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.555 TPI Sid: 2007 Max BC CSI: 0.425 Rep Factors Used: Yes Max Web CSI: 0.744 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE i VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 T CS d n 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W P 1216 /110 /654 /- /214 /8.0 Q 1204 / 96 / 639 / - / - / 8.0 Wind reactions based on MWFRS P Min Brg Width Req = 8.0 Q Min Brig Width Req = 1.5 Bearings P & Q are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 777 -1583 D - E 786 -1299 B - C 1020 -1578 E - F 730 -1436 C - D 783 -1084 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp O- N 368 - 399 K- 1 7 - 6 N - M 1067 - 426 J - H 1222 - 550 M - L 1067 - 426 I - G 18 L - J 1229 - 556 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A - 0 652 -1147 L - E 203 - 226 A- N 1396 - 574 K- J 97 0 O-P 619-1214 E-H 251 -226 B- N 503 - 473 H- 1 295 0 N - C 486 - 316 H - F 1269 - 571 C-L 204 -133 H-G 2 -4 L-D ' 315 -83 F-G 649 -1148 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handling, shipping, installing. and bracing., Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oherw!se,top chord shall have properly attached structural sheathing and bottom chord shall have a propper) attached rigid ceiling Locations shoved for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or I SCOSTA CORPORATION as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSO; Alpine, a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRI) truss in conformance with ANSI/ rPl 1, or for handling shipping, installation and bracing oftrussesA seal on this drawing or cover page SEBRING, FL 33870 listing this drawing indicates acceptance of rofesslona engineering responsibility solely for the design shown. The sui ability (863)385-8242 and use of this cawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. Jo0qumber: 84828 Ply: 1 SEQN: 26918 / T82 / HIPS /SOUTHERN CITY DEVELOPMENTNOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A16 Wgt: 236.6 Ibs .. / ... 12/21/2017 Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.47 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with Bd:Box or Gun (0.113"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0. 1 28"x3",min.)nails C1 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. Right cantilever is exposed to wind 13'10" = 5'4" -, 12'10"� Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: Ni Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 30' 32' Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.047 L 999 360 VERT(TL): 0.111 L 999 240 HORZ(LL): -0.066 B - - HORZ(TL): -0.142 D Creep Factor: 1.5 Max TC CSI: 0.629 Max BC CSI: 0.661 Max Web CSI: 0.949 Mfg Specified Camber: VIEW Ver: 17.02. 01 A. 1114.21 RICHARD A. SIVER P.E. #65698 11 13' ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W P 1124 /107 /615 /- /208 /8.0 H 1300 / 105 / 737 ! - /- / 8.0 Wind reactions based on MWFRS P Min Brg Width Req = 8.0 H Min Brg Width Req = 1.5 Bearings P & H are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 705 -1403 D - E 685 -1092 B-C 731 -1173 E-F 172 -37 C - D 705 - 901 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Corrp, Chords Tens. Comp O - N 355 - 396 K - 1 16 - 2 N - M 1192 - 547 I - H 605 - 274 M-L 1192 -547 H-G 10 -14 L - J 968 - 355 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A - 0 606 -1064 J - D 236 - 29 A - N 1265 - 521 J - 1 606 - 275 0 - P 577 -1123 J - E 381 - 95 N-B 219 -146 I-E 167 -19 B - L 256 - 305 E - H 659 -1293 C-L 365 -78 H-F 215 -145 C-J 131 -218 F-G 56 -54 J -K 109 0 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Itextreme care in fabricating, handling, shi pmg, installing and bracing., Refer to and follow the latest edition of BCSI (Building rt Safety Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperl a3id ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10 COSTA O PO ATION 'le. Apply plates to each face of truss and position as shown above and on the JoinCDetaiL% unless noted otherwise. Refer to WOOD STEEL OR TIMBER 60A-Z for standard plate positions. ROOF OR FLOOR TRUSSES !vision of ITW BuildiFi Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e . _ SEBRING, FL 33870 rawing indicates acceptance 9f professional engineering responsibility solely for the design shown. The sui9 blllty (863)385-8242 �f this ri�awing for anv structure Is Gie responsibility of the Building Designer per ANSI/TPI 1 Sec.2. IV Job Number: 84828 Ply: 1 SEQN: 26908 / T74 / HIPS /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: Al2 Wgt: 228.2 Ibs / ... 12/21/2017 L 122-1/2^ V. Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " d 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.07 ,t TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T1 2x4 SP M-31: Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 1 Od Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. 32' 19'5" i ill. 1116• Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.056 M 999 360 Q 1216 / 125 1656 / - / 182 / 8.0 Lu: NA Cs: NA VERT(TL): 0.153 L 999 240 R 1205 / 112 / 641 / - /- / 8.0 Snow Duration: NA HORZ(LL): -0.054 E - - Wind reactions based on MWFRS HORZ(TL): -0.127 E - Q Min Brg Width Req = 8.0 Code / Misc Criteria Creep Factor: 1.5 R Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.876 Bearings Q & R are a rigid surface. TPI Std: 2007 Max BC CSI: 0.606 Rep Factors Used: Yes Max Web CSI: 0.583 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 774 -1524 D - E 829 -1361 WAVE VIEW Ver: 17.02.01A.1114.21 B - C 850 -1395 E - F 605 -1133 C-D 811 -1174 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Come. P-0 307 -343 L-J 5 -21 0 - N 1298 - 623 K - I 1190 - 490 N - M 1298 - 623 J - H 14 - 27 M-K 1195 -510 H-G 17 -14 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A- P 660 -1153 I- J 220 0 A - 0 1382 - 610 I - D 326 - 32 P-Q 628-1215 I-E 316 -64 O - B 218 -195 I - H 985 - 437 B - M 172 - 224 E - H 428 - 663 C - M 340 -41 H - F 1063 -492 C - 1 149 -156 F - G 662 -1149 L-K 7 -74 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricatingp handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety Information, by TPI and'SBCA) for safe practices prior to performing these functions. Installers shall prop BCSI. Unless noted oyherwise,top chord shall have properly attached structural sheathing and bottom chord shall did ceiling Locations shown'for permanent lateral restraint of webs shall have bracing ins ailed per SCSI sections ile. Apply plate. to each face of truss and position as shown above and on the Joint Details, unless noted otherw 60A-Z for standard plate positions. a division of I NI 1, or for r acceptance any structure his drawing,any failure to build the 3670 COMMERCE CENTER on this drawing or cover pa e SEBRING, FL 33870 ie design shown. The suitability (863)385-8242 JobilUumber: 84828 Ply: 1 SEQN: 26903 / T73 / HIPS /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: All Wgt: 210.0 Ibs .. / 12/21/2017 i _ 192-1/2" 12'T' 9'2-1/2" —{ 12 s p T1 W3 �1gX5 >-E W WS /4X6A T.W9 T (a) L 81 K J B2;.� .l l 4X4 z3X6 -4X4 I Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) lx4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind End verticals not exposed to wind pressure. 32' 19,5" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): 0.061 C 999 360 Lu: NA Cs: NA VERT(TL): 0.144 C 999 240 Snow Duration: NA HORZ(LL): -0.042 D - - HORZ(TL): -0.106 A Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.597 TPI Std: 2007 Max BC CSI: 0.508 Rep Factors Used: Yes Max Web CSI: 0.822 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): VIEW Ver: 17.02.01A.1114.21 WAVE, HS RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W M 1216 /140 /652 /- /152 /8.0 N 1205 / 128 / 638 / - /- / 8.0 Wind reactions based on MWFRS M Min Brg Width Req = 6.0 N Min Brg Width Req = 1.5 Bearings M & N are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 813 -1591 C - D 909 -1403 B - C 910 -1406 D - E 680 -1259 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp L - K 285 - 297 I - G 0 - 25 K - J 285 - 297 G - F 35 - 4 J - H 1327 - 614 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A- L 680 -1129 H- 1 0 - 42 A - J 1344 - 564 H - G 1136 - 494 L-M 637 -1215 H-D 872 -418 B - J 285 -14 G - D 502 - 684 B - H 179 -136 G - E 1068 - 481 C - H 203 - 272 E - F 684 -1124 —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS s require extreme care in fabricatingg handling, shi ping, installing and bracing., Refer to and follow the latest edition of BCSI (Buildini Went Safety Information, by TPI and'SBCA) for safety practices prior to pertorming these functions. Installers shall provide temporary per BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperl d rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections 63, B7 or 810 SCOSTA CORPORATION icable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted othervvise. {2efer to WOOD STEEL OR TIMBER I s 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 this drawing indicates acceptance of professiona engineering responsibility solely for the design shown. The suitability (863)385-8242 ce of this gnawing for any structure is the responsibility of the 6uIlding Designer per ANSI/TPI 1 Sec.2. JobiNumber: 84828 Ply: 1 SEQN: 26901 / T72 / HIPM /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A10 Wgt: 224.0 Ibs ! ... 12/21/2017 T 1 ■1 m '7 1 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " L 8'2-1/2" i' 23'9-1l2" Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.20 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 byALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. 19'5" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 32' Deff/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.080 D 999 360 VERT(TL): 0.187 D 999 240 HORZ(LL): -0.053 H - - HORZ(TL): -0.083 H Creep Factor: 1.5 Max TC CSI: 0.413 Max BC CSI: 0.757 Max Web CSI: 0.972 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 12'7" ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W 0 1216 /161 /664 /- /122 /8.0 P 1205 / 299 / 587 / - / - / 8.0 Wind reactions based on MWFRS 0 Min Brg Width Req = 8.0 P Min Brg Width Req = 1.5 Bearings O & P are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A-B 813-1560 D-E 921 -1634 B - C 955 -1644 E - F 483 - 890 C - D 955 -1644 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp N - M 113 - 435 K - 1 1647 - 930 M-L 1314 -858 J-H 23 -10 L-K 1314 -858 H-G 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A - N 633 -1143 D - 1 306 - 311 A- M 1382 - 434 I- J 98 0 N - 0 610 -1215 I - E 989 - 578 B-M 181 -124 I-H 915 -503 B - K 469 -156 E - H 762 -1079 C - K 235 - 272 H - F 1349 - 732 K - D 67 - 50 F - G 699 -1156 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT"'' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shipping, installing and bracing'. Refer to and follow the latest edition of BCSI (Buildinr f Safety Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary' BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro pperl d�id ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION 'Ie. App?y plates to each face ofptruss and position as shown above and on the Joinf Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER 60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES vision of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3570 COMMERCE CENTER DRIVE lformance with ANSI/. 11, or for handling shippinlq, installation and bracing of trussesA seal on this drawing or cover pa e , , SEBRWG, FL 33s7o drawing indicates acceptance of-iotessiona engineering responsibility solely for the design shown. The suitability (853)385.8242 �f this drawing for any structure is tie responsibility of the Building Designer Der ANSI/TPI 1 Sec.2. 0 JoOVumber: 84828 Ply: 1 SEQN: 26899 / T69 / HIPM /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A9 Wgt: 210.0lbs / ... 12/21/2017 i T io TM 1 1 25'9-1/2" 32' 19'5" 127" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): 0.115 D 999 360 0 1216 / 163 / 642 / - / 92 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.268 D 999 240 p 1205 / 291 / 577 / - / - / 8.0 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): -0.045 H - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: BMean Height: 15.00 ft HORZ(TL): -0.071 H O Min Big Width Req = 8.0 NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 P Min Brg Width Req = 1.5 Soffit: 10.00 BCDL: 6.0 pst Bldg Code: FBC 2014 RES Max TC CSI: 0.487 0 & P are a rigid s Bearings surface. Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2007 Max BC CSI: 0.741 Spacing: 24.0 " C&C Dist a: 3.20 It Rep Factors Used: Yes Max Web CSI: 0.993 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 ft FT/RT:20(0)/l0(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. A - B 815 -1502 D - E 1093 - 2004 GCpi: 0.18 Plate Typa(s): VIEW Ver: 17.02.01A.1114.21 Wind Duration: 1.60 WAVE B - C 1104 -1971 E - F 548 -1034 C - D 1104 -1971 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind End verticals not exposed to wind pressure. RICHARD A. SIVER P.E. #65698 "WARNING— READ A14D FOLLOW ALL NOTES ON THIS DRAWING] —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing,indicates acceptance of rofessional engineerin responsibility solely for the ;e of this rawing for any structure is the responsibility of the E�uilding Designer per ANSI/TPI Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp N- M 72 - 325 K- I 2022 -11 W I M - L 1283 - 828 J - H 30 -15 L'- K 1283 - 828 H- G 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A - N 646 -1165 D - I 295 - 294 A- M 1401 - 522 I- J 99 0 N-0 631 -1215 I-E 1187 -668 B - M 218 - 235 I - H 1063 - 568 B - K 845 - 350 E - H 767 -1120 C - K 332 - 374 H - F 1447 - 766 K - D 92 - 65 F - G 686 -1156 SCOSTA CORPORATION WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES failure to build the 3670 COMMERCE CENTER DRIVE orhersiaSEBRING, FL 33870nTubility (863)385-8242 JoboNumber: 84828 Ply: 1 SEQN: 26124 / T83 / HIPM /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A17 Wgt: 235.2 Ibs .. / ... 12/21/2017 f 21'2„ 1 1 32' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT:NA TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA EXP: B Des Ld: 37.00 Mean Height: 15.22 ft NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2007 Spacing: 24.0 " C&C Dist a: 3.20 it Rep Factors Used: Yes Loc. from endwall: not in 9.0o ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Bracing (b) lx4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. (a) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Plating Notes All plates are 4X4 except as noted. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind End verticals not exposed to wind pressure. PLATING NOTES All plates are 4X4 except as noted. Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.055 C 999 360 VERT(TL): 0.129 C 999 240 HORZ(LL): 0.019 G - - HORZ(TL): 0.043 G Creep Factor: 1.5 Max TC CSI: 0.734 Max BC CSI: 0.665 Max Web CSI: 0.804 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 P.E. #65698 10,10', -{ 14 ?X4 ♦ Maximum Reactions (Ibs), or "=PLF Loc R /U /Rw /Rh /RL /W L 1198 / 323 / 597 / - / 162 / 8.0 M' 459 / 54 / 263 / - / - / 32.0 Wind reactions based on MWFRS L Min Brg Width Req = 1.5 M Min Brg Width Req = - Bearings L & M are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 441 - 761 D - E 656 -1149 B - C 660 -1076 E - F 111 - 63 C - D 660 -1076 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp L - K 313 - 64 I - H 968 - 359 K - J 787 -150 H - G 1663 - 825 J - 1 968 - 359 Maximum Web Forces Per Ply (Ibs) - Webs Tens.Comp. Webs Tens. Comp. A - L 735 -1143 J - D 175 - 37 A-K 1241 -719 D-H 137 -20 K- B 664 - 822 H- E 238 0 B - J 477 - 328 E - G 623 -1264 C - J 345 - 381 F - G 180 -129 "WARNING'" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Buildirr, Component Safety. Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted oiherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propper) attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 610 SCOSTA CORPORATION as applicable. Apply plates to each face of truss and position as shown above and on the Joinf"Details, unless noted otherwise. refer to WOOD STEEL OR TIMBER drawings 160A-Z for standard plate positions. ROOF 6R FLOOR TRUSSES Alpine, a division of ITW BuildingComponents Group Inc., shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE truss in conformance with ANSI/ fPI 1. or for handlingf shipping, installation and bracing of trussesA seal on this drawing or cover page . , SEBRING, FL 33870 listing this drawing indicates acceptance of pro essiona engineering responsibility solely for the design shown. The suigability (863)385-8242 and use of this drawing, for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. s JoblNumber: 84828 Ply: 1 SEQN: 26963 / T24 / COMN /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: Al Wgt: 232.4 Ibs .. / ... 12/21/2017 15,10" =3X8(B1) a� Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.90 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.1 13"x2.5", min.) nails @ 6" OC. (c) 2x6 #3 or better "T" reinforcement. 80% length of web member. Attach with 16d Box or Gun (0.135"x3.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 1470 lbs. `*Wii 39' U ro M bi ro 11 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.139 K 999 360 A 1481 / 203 / 894 / - / 236 / 8.0 Lu: NA Cs: NA VERT(TL): 0.326 K 999 240 G 1470 / 370 / 752 / - / - / - Snow Duration: NA HORZ(LL): 0.054 H - - Wind reactions based on MWFRS HORZ(TL): 0.126 H A Min Brg Width Req = 1.7 Code / Misc Criteria Creep Factor: 1.5 G Min Brg Width Req = - Bldg Code: FBC 2014 RES Max TC CSI: 0.924 Bearing A is a rigid surface. TPI Std: 2007 Max BC CSI: 0.910 Rep Factors Used: Yes Max Web CSI: 0.895 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 1218 - 2726 D - E 655 -1202 WAVE VIEW Ver: 17.02.01A.1114.21 B - C 1044 -2075 E - F 655 -1202 C - D 975 -1756 RICHARD A. SIVER P.E. Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Chords Tens. Comp A - M 2357 -1420 J - 1 1750 - 975 M - L 2354 -1422 1 - H 1750 975 L- K 2354 -1422 H- G 0 0 K - J 1769 -1046 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M-B 321 0 D-H 469 -801 B - K 438 - 668 E - H 436 - 473 C - K 541 -115 H - F 1722 - 938 C-J 106 -112 F-G 853 -1408 J - D 306 0 "WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS reqquire extreme care in fabricating handling, shi pping, installing and bracing. Refer to and follow the latest edition of BCSI (Buildirn Went Safety Information, b TPI and SBCA) for safety practices pnor to performing these functions. Installers shall provide temporaryf er BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propper) Sri id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION cable. Apply plate- to each face of truss and position as shown above and on the JoinCDetaiIs, unless noted otherwise. I?efer to WOOD STEEL OR TIMBER s 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER Dili conformance with ANSI PI 1, or for handlZ shipping, installation and bracing of trussesA seal on this drawing or cover page , . SEBRING, FL 33870 this drawing Indicates acceptance of pro esslonal engineering responsibility solely for the design shown. The suitability (863)385-8242 ;e o this yawing for any structure is the responsibility of the uilding Designer per ANSI/TPI 1 Sec.2. 11 Job Number: 84828 Ply: 1 SEQN: 26966 / T21 / COMN /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: Al Wgt: 239.4 Ibs .. / ... 12/21/2017 13'10" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.90 ft Loc. from endwall: not in 9.00 It GCp!: 0.16 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or GLn (0. 1 13"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 1470 lbs. 25'2" 39' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.151 L 999 360 A 1481 / 205 / 875 / - / 206 / 8.0 Lu: NA Cs: NA VERT(TL): 0.354 L 999 240 H 1470 / 362 / 736 / - / - / - Snow Duration: NA HORZ(LL): 0.056 1 - - Wind reactions based on MWFRS HORZ(TL): 0.130 1 A Min Brg Width Req = 1.7 Code / Misc Criteria Creep Factor: 1.5 H Min Brg Width Req = - Bidg Code: FBC 2014 RES Max TC CSI: 0.595 Bearing A is a rigid surface. TPI Std: 2007 Max BC CSI: 0.739 Rep Factors Used: Yes Max Web CSI: 0.969 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 1285 - 2767 D - E 984 -1822 WAVE VIEW Ver: 17.02.01A.1114.21 B - C 1138 -2216 E - F 984 -1822 C - D 1149 - 2075 F - G 608 -1137 RICHARD A. SIVER ,P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - 0 2403 -1442 L - K 2078 -1153 O - N 2400 -1444 K - J 2078 -1153 N - M 2400 -1444 J - 1 1184 - 640 M-L 1905-1118 I-H 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. 0-B 275 0 E-J Z75 -313 B - M 385 - 567 J - F 970 - 523 C - M 458 -109 F - I 768 -1134 C - L 255 - 89 I - G 1708 - 914 L - D 141 - 65 G - H 836 -1420 D - J 258 - 390 ""WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating handling, ship Ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building Componen Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properg attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION as applicable. Apply pgates to each face of truss and position as shown above and on the Joinf Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES Alpine, a division of ITW BuildinggComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE truss in conformance with ANSI 1, or for handling shipping, installation and bracing of,trussesA seal on this drawing or cover pa e , , SEBRING, FL 33870 listing this drawing, indicates acceptance of pro fessronaT engineerin responsibility solely for the design shown. The sui ability (863)385-8242 and use of this i}awing for any s,ructu: Z' is tin responsibility of the Bquilding Designer per ANSIITPI 1 Sec.2. f Joh Number: 84828 Ply: 1 SEQN: 26972 / T20 / COMN /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A20 Wgt: 232.4 Ibs .. / ... 12/21/2017 ` 1— 11,10" }- 27'2" =5X8 12 -4X4 -6X6 =4X4 D E T2 F G T2 _ 6 H 6 � o4X5C W3 W3 W3 W� (a) (a) W4 W4 a W3 W1 W2 W3 c5 In 04X4A54 B1 P 0 N B2 M L K B3 J I D-ya 1112X4 —3X6 —04 —04 3X6 —4X10 —4X6 39' �-- 2' --{ Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf. NA Ce: NA VERT(LL): 0.181 E 999 360 B 1618 / 427 / 957 / - / 272 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.423 E 999 240 1 1466 / 423 / 718 / - / - / - BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.059 J - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: 6Mean Height: 15.00 It HORZ(TL): 0.137 J B Min Brg Width Req = 1.9 NCBCLL: 10.00 TCDL: .0 psf Code / Misc Criteria Creep Factor: 1.5 1 Min Brg Width Req = - Soffit: 10.00 BCDL: 6psf Bldg Code: FBC 2014 RES Max TC CSI: 0.732 Bearing g B is a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2007 Max BC CSI: 0.773 Spacing: 24.0 " C&C Dist a: 3.90 ft Rep Factors Used: Yes Max Web CSI: 0.946 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Plate Type(s): A - B 60 0 E - F 1170 -2204 Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1114.21 B - C 1309 -2748 F - G 1170 -2204 Lumber C - D 1215 -2344 G - H 744 -1413 Value Set: 13B (Effective 6/1/2013) D - E 1311 -2412 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Webs 2x4 SP #2 Chords Tens.Comp. Chords Tens. Comp. :Lt Level Return 2x4 SP #2: B - P 2386 -1420 M - L 2422 -1321 Lumber value set "l3B" uses design values P - 0 2384 -1422 L - K 2422 -1321 approved 1/30/2013 by ALSC 0 - N 2384 -1422 K - J 1467 -781 N- M 2038 -1177 J -1 0 0 Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% Maximum Web Forces Per Ply (Ibs) length of web member. Attach with 8d Box or Gun Webs Tens.Comp. Webs Tens. Comp. (0.113"x2.5",min.)nails @ 6" OC. A- Q 3 0 E- K 205 - 294 Purlins P - C 208 0 F - K 296 - 338 In lieu of rigid ceiling provide lateral bracing to brace C - N 282 - 399 K - G 996 -526 BC @ 24" OC D - N 402 -74 G - J 754 -1105 Wind D - M 501 - 221 J - H 1891 - 995 M - E 233 -196 H - 1 826 -1412 Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 1466 lbs. RICHARD A. SIVER P.E. #65698 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg handling, shi ping, installing and bracing., Refer to and follow the latest edition of BCSI (Building Component Safety. Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperg attached rg id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES Alpine, a division of ITW Bulldin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE truss in conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e SEBRING, FL 33870 listing this drawing indicates acceptance of professional engineerin responsibility solely for the design shown. The sui[ability (863)385-8242 and use of this drawing for any structure is the responsibility of the �uilding Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites: ALPINE: www.aiDineitw.com: TPI: www.toinst.ora: SBCA: www.sbcindustrv.com, ICb www.inmafa ara 1 JoVNumber: 84828 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Truss Label: A21 i. 9'10" Ply: 1 SEQN: 26975 / T18 / COMN Qty: 1 FROM: DRW: Wgt:214.2lbs / ... 12/21/2017 29'2" m4X4 - -6X6 m4X4 r� -3XB(B1 �04X4A � F- 2' "I U N M- ----- v L K J 63 I H 1112X4 —4X4 =H0308=4X10 -5X6 1113X6 39' TT EnS6 1� 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h/2 to h Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA VERT(LL): 0.206 D 999 360 VERT(TL): 0.482 D 967 240 HORZ(LL): 0.058 C - - HORZ(TL): 0.136 C Creep Factor: 1.5 Max TC CSI: 0.984 Max BC CSI: 0.878 B 1618 / 434 / 935 / - / 231 / 8.0 H 1466 / 418 / 707 / - / - / - Wind reactions based on MWFRS B Min Brg Width Req = 1.5 H Min Brg Width Req = - Bearing B is a surface. rigid Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Spacing: 24.0 " C&C Dist a: 3.90 ft Loc. from endwall: not in 9.00 ft Rep Factors Used: Yes FT/RT:20(0)/10(0) Max Web CSI: 0.819 Mfg Specified Camber: Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 60 0 D - E 1430 - 2737 GCpi: 0.18 Plate Type(s): [VI FEW Ver: 17.02. 01 A. 1114.2 1 Wind Duration: 1.60 WAVE, HS B - C 1277 -2604 E - F 1430 -2737 C - D 1523 - 2853 F - G 934 -1801 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T1 2x4 SP M-31: Bot chord 2x4 SP #2 :B1 2x4 SP M-31: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0. 1 13"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid c9iling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection.at right end of truss for 1466 lbs. RICHARD A. SIVER #65698 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "`IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest nent Safety. Information, b• TPI and SBCA) for safety practices prior to performing these functions. Installers CriBer BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathingg and bottom ct rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracin insTalled per BCSI ie. Appiy plates to each face of truss and position as shown above and on the Join Details, unless nol Is 16OA-Z for standard plate positions. a division of ITW Buildingg�Components Group Inc. shall not be responsible for any deviation from this drawin conformance with ANSI ITPI 1, or for handlinj shipping, installation and bracing of trussesA seal on this dr this drawing indicates acceptance of pro essiona engineering responsibility solely for the design ;e of this yawing or any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec. Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - N 2226 -1279 K - J 2870 -1538 N - M 2232 -1277 J - 1 1864 - 978 M- L 2232 -1277 I- H 0 0 L - K 2870 -1538 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A- 0 3 0 E- J 328 - 373 C- N 363 0 J- F 1068 - 553 C - L 753 - 359 F - I 744 -1080 L - D 288 - 300 1 - G 2186 -1134 D-J 131 -163 G-H 819 -1408 of ins 03, rsr or tsiu- kefer to SCOSTA CO PO ATION ierwise. WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES failure to build the 3670 COMMERCE CENTER DRII I or cover page _ SEBRING, FL 33870 n. The sui ability (863)385-8242 Jolt Number: 84828 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Truss Label: A22 Ply: 1 Qty: 1 Wgt: 305.2 Ibs SEQN: 27015 / T28 / COMN FROM: DRW: 12/21 /2017 12 6p =4X6 A3 B =4X6 A3� ��$4X4A 11 P 0-T4 J I f- 2; 31'2" = D ==-10X10 =5X8 C=8X8 T2 E F T3 —8X1?G 1m r N M L 82 K J 1113X8 =H0710 =4X10 =5X14=H0710 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.90 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x8 SP 2400f-2.0E .T1 2x4 SP M-31: Bot chord 2x8 SP 2400f-2.OE Webs 2x4 SP #2 :W4 2x4 SP M-31: :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement 80% length of web member. Attach with 8d Box or Gun (0. 1 13"x2.5",min.)nails @ 6" OC. (b) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Loading #1 hip supports 7-10-0 jacks with no webs. Left side jacks have 7-10-0 setback with 0-0-0 cant and 2-1-9 overhang. End jacks have 7-10-0 setback with 0-0-0 cant and 2-1-9 overhang. Right side jacks have 0-0-0 setback with 0-0-0 cant and 0-0-0 overhang. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. 39' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL Pf: NA Ce: NA VERT(LL): 0.373 E 999 360 p 3284 / 854- Lu: NA Cs: NA VERT(TL): 0.887 E 525 240 H 3380 / 845- Snow Duration: NA HORZ(LL): 0.071 C - - Wind reactions based on MWFRS HORZ(TL): 0.168 C P Min Brg Width Req = 2.7 Code / Misc Criteria Creep Factor: 1.5 H Min Brg Width Req = - Bldg Code: FBC.2014 RES Max TC CSI: 0.651 Bearing P is a rigid surface. TPI Std: 2007 Max BC CSI: 0.452 1115X14 /W / 8.0 TCo T c� Rep Factors Used: No Max Web CSI: 0.984 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 60 -26 D - E 2185 - 8781 WAVE, HS VIEW Ver: 17.02. 01 A. 1114.21 B - C 1680 -6683 E - F 2185 -8781 Additional Notes C - D 2184 - 8769 F - G 1470 - 5931 Provide hanger or special connection at right end of truss for 3380 Ibs. Maximum Bot Chord Forces Per Ply (Ibs) RICHARD A. SIVER P.E. #65698 Chords Tens.Comp. Chords Tens. Comp. B - N 5936 -1470 K - J 6120 -1545 N - M 5901 -1469 J - 1 6120 -1545 M -'L 5901 -1469 I - H 12 - 3 L - K 8848 - 2228 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A- O 3 0 E- K 509 - 884 N - C 893 -15 K - F 2950 - 709 C - L 3197 - 795 F - I 948 - 2382 L - D 593 -1053 I - G 6539 -1620 D - K 48 - 75 G - H 927 - 3207 "'WARNING* READ ;ND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of q Safety Information, by TPI an eSBCA) for safety practices pnor to performing these functions. Installers shall prop BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall id ceiling Locations shown forpermanent lateral restraint of webs shall have bracin ins alted per BCSI sections e. AppTy plates to each face of truss and position as shown above and on the Joini9Details, unless noted otherw 60A-Z for standard plate positions. a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI 1, or for handling' shipping, installation and bracing of trussesA seal on this drawing or cover page , , SEBRING, FL 33670 this drawing indicates acceptance of professlona1 engineering responsibility solely for the design shown. The sui[abdrty (863)385-8242 ,e of this yawing for any structure is the responsibility of the 9uildma Desianer oer ANSI/TPI 1 Sec_2_ t Job -Number; 84828 Ply: 1 SEQN: 26129 / T52 / SPEC /SOUTHERN CITY DEVELOPMENT, /VOSSEN/COD /BLG City: 1 FROM: DRW: Truss Label: C3 Wgt: 170.8 Ibs .. / ... 12/21/2017 2' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.u0 Risk Category: II Des Ld: 37.00 EXP: BMean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP M-31 :82 2x4 SP #2: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Left cantilever is exposed to wind 157" i13,3„ 28'2" 28'10" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.061 J 999 360 0 1273 / 339 / 750 10 / 253 / 8.0 Lu: NA Cs: NA VERT(TL): 0.144 J 999 240 P 1048 / 274 / 563 /- /- / 8.0 Snow Duration: NA HORZ(LL): 0.018 H - - Wind reactions based on MWFRS HORZ(TL): 0.046 H - - 0 Min Brg Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 P Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.515 Bearings 0 & P are a rigid surface. TPI Std: 2007 Max BC CSI: 0.728 Rep Factors Used: Yes Max Web CSI: 0.440 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 61 0 D - E 627 -1175 WAVE VIEW Ver: 17.02.01A.1114.21 1 B - C 192 -743 E - F 655 -1175 C - D 721 -1653 F - G 676 -1438 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - M 1335 - 344 K - J 1410 - 583 M - L 736 - 261 J - 1 1242 - 524 L - K 1410 - 583 1- H 32 - 29 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp, Webs Tens. Comp A-N 3 0 E-J 593 -191 M - C 564 - 775 J - F 261 - 314 C - L 824 - 550 F - I 201 -119 L- D 223 0 I- G 1231 -495 D - J 328 - 504 G - H 539 -1003 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shippIng, installing and bracing. Refer to and follow the latest edition of t Safety. Information, byy TPI and'SBCA) for safety practices prior to performing these functions. Installers shall prop BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall �id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I r e. Apply plates to each face oftrussand position as shown above and on the Joint Details, unless noted otherw 60A-Z for standard plate positions. a division of ITW BuildinhComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e this drawingg indicates acceptance of professional engineerin responsibility solely for the design shown. The suiFability ,e of this r7�awing for any structure Ic the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. SCOSTA CORPORATION WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES 3670 COMMERCE CENTER DRIt SEBRING, FL 33870 (863)385-8242 JoO Number: 84828 /SOUTHERN CITY DEVELOPMENT IVOSSEN/COD /BLG Truss Label: C2 Ply: 1 SEQN: 26945 / T3 / HIPS Qty: 1 FROM: DRW: Wgt: 236.6 Ibs Page 1 of 2 .. / ... 12/21/2017 3-10- i--- 2' -{ Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 f: NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) - Top chord 2x4 SP M-31 :T3, T5 2x4 SP #2: Bot chord 2x6 SP M-14 :82 2x6 SP #2: Webs 2x4 SP #2 :Lt Slider 2x4 SP #2: BLOCK LENGTH = 1.917' :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0. 1 13"x2.5",min.)nails @ 6" OC. (b) 2x4 #3 or better "T" reinforcement. 80% length of web member. Attach with 16d Box or Gun (0.135"x3.5",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Left cantilever is exposed to wind 11,91, i 11.91, i 1161, 2s7- 28'10" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.183 T 999 360 B 2040 / 870 / - ! - / - / 8.0 Lu: NA Cs: NA VERT(TL): 0.426 T 785 240 W 1446 / 477 / - / - / - / 8.0 Snow Duration: NA HORZ(LL): 0.037 Q - - Wind reactions based on MWFRS HORZ(TL): 0.087 Q B Min Brg Width Req = 2.4 Code / Misc Criteria Creep Factor: 1.5 W Min Brg Width Req = 1.7 Bldg Code: FBC 2014 RES Max TC CSI: 0.707 Bearings B & W are a rigid surface. TPI Std: 2007 Max BC CSI: 0.768 Rep Factors Used: Yes Max Web CSI: 0.929 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): B - C 477 -1215 H - J 0 -464 WAVE VIEW Ver: 17.02.01A.1114.21 A - B 63 -28 I - L 568 -1469 C - D 1285 - 3015 J - K 24 - 558 D - E 1129 - 2672 K - M 24 - 558 E - F 284 - 572 L - N 764 - 2031 E - G 981 - 2397 M - N 24 - 552 F - H 287 - 585 N - 0 680 - 2299 G - 1 561 -1455 0 - P 39 - 38 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - U 2599 -1107 S - R 3627 -1288 U - T 3627 -1288 R - Q 1136 - 434 T- S 3627 -1288 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A- V 3 0 1-1 967 - 307 B - C 865 -1957 J - L 202 - 562 D- U 299 - 50 K- R 286 0 U - H 179 -1149 R - O 1169 - 242 F-G 498 -125 L-M 212 0 G - J 410 - 922 0 - Q 703 -1794 H-T 1124 -301 P-Q 47 -26 H - R 637 -1449 I "WARNING'" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Nina extreme care in fabricating A rid ing, sh ping,_ installing and bracing.. Refer to and follow the _latest edition of .1-wii 1U1 ciuJancnr mielai resuamr or wens snan nave Dracln instaneo per tiubl sections 63, B7 'or B10- SCOSTA COR.POR ATIO� icab e. App y plates to each face o truss and position as shown above and on the Join Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER is 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW BuilZhComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa gge , , SEBRING, FL 33870 this drawing indicates acceptance of proress ona engmeenn responsibility solely for the design shown. The sui[abili y (863)385-8242 ;e of this drawing for any structure is the responsibility of the Rullding Designer per ANSI/TPI 1 Sec.2. a 84828 /SOUTHERN CITY DEVELOPMPdT NOSSEN/COD /BLG C2 Special Loads -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 plf at 3.83 TC: From 28 plf at 3.83 to 28 plf at 11.27 TC: From 56 plf at 11.27 to 56 plf at 27.29 TC: From 56 plf at 27.33 to 56 plf at 28.83 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 pif at 3.86 BC: From 10 plf at 3.86 to 10 plf at 11.27 BC: From 20 plf at 11.27 to 20 plf at 28.83 PLB: From 20 plf at -1.96 to 20 plf at -0.10 TC: 98 lb Conc. Load at 3.86 TC: 77 lb Conc. Load at 5.90, 7.90 TC: 79 lb Conc. Load at 9.90 BC: 34 lb Conc. Load at 3.86 BC: 15 lb Conc. Load at 5.90. 7.90 BC: 62 lb Conc. Load at 9.90 BC: 993 lb Conc. Load at 11.27 Ply: 1 SEQN: 26945 / T3 / HIPS Qty: 1 FROM: Wgt: 236.6 lb s Page 2 of 2 RICHARD A. SIVER P.E. #65698 DRW: 12/21 /2017 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of SCSI (Building t Safety Information, bV TPI anc3 SBCA) for safety practices prior to pertorming these functions. Installers shall provide temporary BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erl ' �id ceiling Locations shown for permanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, B7 or �10 e. Apply plates to each face of truss and position as shown above and on the JoinfDetails, unless noted otherwise. {2efer to 0 ST E 0 T BEES 60A-Z for standard plate positions. rgg Components Group:lnc. shall not be responsible for anY deviation from this drawing,any failure to build the truss in conformanc fPl 1, or for handing, shipping, installation and bracing o ,trusses. A seal on this drawing or cover pa a listing this drawing, acceptance of proiessronaf en3ineering responsibility solely for the design shown. The suitability and use of this (863)385-8242 �r any structure is the responsibTty of the Building Designer per ANSI/TPI gSec.2. Job Number: 84828 /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: D5 Ply: 1 SEQN: 26935 / T64 / HIPS Qty: 1 FROM: Wgt: 145.6 Ibs DRW: 1— 310" io c m io c� rV 43%i6' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed:- 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B NCBCLL: 0.00 Mean Height: 15.00 ft TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Pamllel l'3iat: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc, from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T2 2x4 SP M-31: Bot chord 2x4 SP M-31 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 byALSC Loading #1 hip supports 3-10-0 jacks with no webs. Left side jacks have 3-10-0 setback with 0-0-0 cant and 2-1-9 overhang. End jacks have 3-10-0 setback with 0-0-0 cant and 2-1-9 overhang. Right side jacks have 3-10-0 setback with 0-0-0 cant and 0-0-0 overhang. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC 87 87' 24' 3' 10" -� 12/21 /2017 Snow Criteria (Pg,Pf in PSF) I Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NAI PP Deflection in loc L/defl L/# I Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.069 K 999 360 B 1160 1279 / - / - / - / 8.0 Lu: NA Cs: NA VERT(TL): 0.171 K 999 240 1 1069 / 227 / - / - / - 18.0 Snow Duration: NA HORZ(LL): 0.023 J - - Wind reactions based on MWFRS HORZ(TL): 0.056 J B Min Brg Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 1 Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.907 Bearings B & I are a rigid surface. TPI Std: 2007 Max BC CSI: 0.334 Rep Factors Used: No Max Web CSI: 0.100 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 45 - 26 E - G 269 -1165 WAVE VIEW Ver: 17.02.01 A.1114.21 B - C 367 -1970 F - G 139 - 852 C - D 295 -1752 G - H 338 -1826 D - E 269 -1165 H - 1 409 - 2043 D - F 96 - 778 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp, Chords Tens. Comp. B - M 1720 - 307 K - J 1498 - 298 M - L 1498 - 298' J - 1 1791 - 348 L - K 1498 - 298 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-N 0 0 F-K 248 0 C-M 115 0 F-J 321 -35 M-F 245 0 J-H 123 0 E - F 442 0 RICHARD A. SIVER P.E. #65698 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricatingg handling, shi gg, installing and bracing. Refoadfoowthe latestedition ofSfetyInformaton,bTPanrlSBCA)forsafeprctcespriortopertormingthese functionsInstallersshallv��Itl ceilingnlLocatonsohownforpoermanent lateestfraPnt of webs shallrhave braclnppthnsalled per BCShsectionsl I /1e. AppT plates to each face of truss and position as shown above and on the JoinfDetails, unless noted .the. 60A-Z for standard plate positions. yr V r vvn I nua� a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSI /TPI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover pa e . , SEBRING, FL 33870 this drawingg indicates acceptance of pro essiona engineering responsibility solely for the design shown. The sunabdlty (863)385-8242 le of this drawing for any structure is the responsibility of the Buildinq Desioner Der ANSI/TPI 1 Sec_2 Job'Number: 84828 /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: C1 h-- 37' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: BMean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Stub Wedge 2x4 SP #2: Lumber value set "136" uses design values approved 1/30/2013 by ALSC Special Loads -----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac =1.25) TC: From 56 plf at 0.00 to , 56 plf at 3.17 TC: From 28 plf at 3.17 to 28 plf at 16.00 TC: From 56 plf at 16.00 to 56 plf at 17.50 BC: From . '.,0 plf at 0.00 to 20 plf at 3.20 BC: From 10 plf at 3.20 to 10 plf at 17.50 TC: 98 lb Conc. Load at 3.20,15.97 TC: 77 lb Conc. Load at 5.25, 7.23, 9.23, 9.94 11,94,13.94 BC: 34 lb Conc. Load at 3.20,15.97 BC: 15 lb Conc. Load at 5.23, 7.23, 9.23, 9.94 11.94,13.94 Plating Notes (++) - This plate works for both joints covered. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes Provide hanger or special connection at left end of truss for 811 Ibs. Ply: 1 SEQN: 26940 / T36 / HIPS Qty: 1 FROM: DRW: Wgt: 113.4 Ibs .. / ... 12/21/2017 " 6'5" f 6'4-1/2" 1'6" E=5X6 17'6" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): -0.041 C 999 360 Lu: NA Cs: NA VERT(TL): 0.081 C 999 240 Snow Duration: NA HORZ(LL): -0.014 J - - HORZ(TL): 0.028 J - Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.583 TPI Std: 2007 Max BC CSI: 0.689 Rep Factors Used: Yes Max Web CSI: 0.279 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 !X4 &T6" 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W A 811 /521 /- /- /- / - N 829 / 578 / - / - / - / 8.0 Wind reactions based on MWFRS A Min Brg Width Req = - N Min Brg Width Req = 1.5 Bearing N is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 936 -1347 E - G 550 - 768 B - C 808 -1159 F - G 278 - 390 C - D 349 - 521 G - H 737 -1029 C - E 550 - 768 H - 1 28 - 48 D - F 278 - 390 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - M 1149 - 800 L - K 1012 - 723 M - L 1012 - 723 K - J 561 - 394 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B - M 111 - 20 K - H 476 - 348 M-D 190 -79 H -J 617 -888 D - K 227 - 24 I - J 23 - 55 E - F 284 - 92 `*WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI -IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide to BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathing and bottom chord shall have ceiling Locations shown for permanent lateral restraint of webs shall have bracin ins�alled per BCSI sections B3, B; e. Apply plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. 50A-Z for standard plate positions. a division of ITW BuildMComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSI/TPI 1, or for handlin shippin , installation and bracing of.trussesA seal on this drawing or cover pa e , , sMMERCG, C NTE 3870 this drawing indicates acceptance of pro) essiona� engineerinQ responsibility solely for the design shown. The suifability (863)385-8242 ;e of this gnawing for any structure is the responsibility of.the 6ulldina Desioner oer ANSI/TPI 1 Sec2. Job Number, : 4828 Ply: 1 SEQN: 26164 / T31 / HIPM /SOUTHERN CITY DEV%LOPMENT /VOSSEN/COD /BLG Qty: 1 FROM:, DRW: Truss Label: A8 Wgt: 141.4 Ibs .. / ... 12/21/2017 =3X5(A ma r 10'2-1/2" • i. 17'5-1/2" Loading Criteria (psf) I Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.Ob Speed: 170 mph BCLL: 0.00 `Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: IS. 00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: > 2h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T1 2x4 SP #2: Bot chord 2x4 SP M-31 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing • (b) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.1 13"x2.5", min.) nails @ 6" OC. (a) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 1 Od Box or Gun (0.128"x3",min.)nails @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 27'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.064 1 999 360 VERT(TL): 0.150 1 999 240 HORZ(LL): 0.018 B - - HORZ(TL): 0.041 B Creep Factor: 1.5 Max TC CSI: 0.470 Max BC CSI: 0.403 Max Web CSI: 0.995 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W A 1052 / 175 / 612 / - / 152 / 8.0 J 1041 /281 /520 /- /- /8.0 Wind reactions based on MWFRS A Min Brg Width Req = 1.5 J Min Brg Width Req = 1.5 Bearings A & J are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 928 -1856 C - D 720 -1319 B - C 779 -1569 D - E 720 -1319 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - 1 1612 -1040 H - G 1355 - 780 1 - H 1355 -780 G-F 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - 1 296 - 293 D - G 507 - 568 C - 1 445 - 30 G - E 1532 - 836 C-G 71 -107 E-F 619 -970 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Buildin! t Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro pper, did ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or 810 S --RCO Pn A ---I 'le. Apply plates to each face of truss and position as shown above and on the JoinCDetails, unless noted otherw!se.. Refer tc wooD STEEL oR TIMBER BOA-Z for standard plate positions. ROOF bR FLOOR In vision of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance with ANSI/� PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e . , SEBRING, FL 33870 drawing indicates acceptance of professiona engineering responsibility solely for the design shown. The sui[ability (863)385 8242 >f this drawing for any structure is tYte responsibility of the 6uildin i Desianer oer ANSI/TPI 1 Ser.2_ A Jotf Number: $4828 Ply: 1 SEQN: 26003 / T16 / SPEC /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss -Label: A7 Wgt:140.0lb. / ... 12/21/2017 L 10, 4-�1_16" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.0�t Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean HeiCht: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: > 2h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T2, T3 2x4 SP #2: Bot chord 2x4 SP M-31 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gun (0.113"x2.5",min.)naiIs @ 6" OC. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. 1'6" t 16,2" 27'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.071 C 999 360 A 1052 / 157 / 596 / - / 149 / 8.0 Lu: NA Cs: NA VERT(TL): 0.167, C 999 240 J 1041 / 265 / 513 / - /- / 8.0 Snow Duration: NA HORZ(LL): 0.024 B - - Wind reactions based on MWFRS HORZ(TL): 0.057 B A Min Brg Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 J Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.770 Bearings A & J are a rigid surface. TPI Std: 2007 Max BC CSI: 0.453 Rep Factors Used: Yes Max Web CSI: 0.909 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 831 -1698 C - D 813 -1513 WAVE VIEW Ver: 17.02. 01 A. 1114.21 B - C 882 -1562 D - E 813 -1513 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - 1 1421 - 828 H - G 1669 - 954 1 - H 1669 -954 G-F 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - 1 937 - 340 D - G 475 - 528 I - C 439 - 735 G - E 1708 - 917 C - G 160 -177 E - F 609 - 973 —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS s require extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Buildin( Went Safety. Information, byy TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propper) d riggid ceiling Locations shown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or 610 SCOSTA CORPORATION icable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WOOD STEEL OR TIMBER Is 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW BuildinggComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 this drawing indicates acceptance of professiona engineering responsibility solely for the design shown. The sui[ability (863)385-8242 re of this gnawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. r Job Number: 84828 Ply: 1 BEGIN: 26005 / T42 / SPEC /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A6 Wgt: 138.6 Ibs .. / ... 12/21/2017 10, f--.2' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: > 2h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 :T1 2x4 SP M-31: Bot chord 2x4 SP M-31 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set 13B" uses design values approved 1/30/2013 byALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with 8d Box or Gran (0. 1 13"x2.5", min.) nails @ 6" OC. Purlins - In lieu of rigid ceiling prcvide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. C=-5X6 3'6" } 14'2" 27'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(I-Q: 0.105 D 999 360 Lu: NA Cs: NA VERT(TL): 0.241 D 999 240 Snow Duration: NA HORZ(LL): 0.035 C - - HORZ(TL): 0.079 C - Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.805 TPI Std: 2007 Max BC CSI: 0.536 Rep Factors Used: Yes Max Web CSI: 0.987 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE, HS VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1156 /159 /680 /- /169 /8.0 L 1037 / 239 1498 ! - / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 L Min Brg Width Req = 1.5 Bearings B & L are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A- B 45 0 D- E 937 -1775 B - C 848 -1679 E - F 937 -1774 C-D 913-1606 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 1398 - 771 I - H 2164 -1241 J-1 2164-1241 H-G 18 -13 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A-K 0 0 E-H 416 -460 C - J 972 - 355 H - F 1938 -1020 J - D 667 -1035 F - G 596 - 980 D - H 335 - 430 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! `"IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi �IngInstalling and bracingRefertoand foothe ltesteioofBCSI(Buildin)tSafetyInformationb TPanSBCAfosafepractices pnor toperformingthesefunctgions. Installersshallrovide temporyItl ceilingnlLocstloensohownfor oermanent latelrestralntlof websshallhave braCien thnstalled per BCShseetional B3vB7 oro10eApplyplastoeach faceotrussand posin as shown above and on the Joinl9Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. KUUr UK rLUUK TKU55E5 a dn' n of ITW Building Components Group Inc, shall not be responsible for any deviation from this drawing any failure to build the 3670 COMMERCE CENTER DRIVE conformance with AN PI PI 1, or for handlingf shipping, installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 this drawingg indicates acceptance of ro essronaf engineerin�g responsibility solely for the design shown. The suig bility (863)385-8242 e of this thawing for any structure is tie responsibility of the t3uilding Designer per ANSI/TPI 1 Sec.2. q Job'Number: 84828 Ply: 1 1 SEQN: 26008 / T40 / SPEC /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A5 Wgt: 151.2 Ibs .. / ... 12/21/2017 f 10' i5'6" Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II B Des Ld: 37.00 Mea Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T2 2x4 SP #2: Bot chord 2x6 SP M-14 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) #3 or better scab reinforcement. Same size & 80% length of web member. Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC. Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 plf at 20.94 TC: From 28 plf at 20.94 to 28 plf at 27.67 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 20.94 BC: From 10 plf at 20.94 to 10 plf at 27.67 TC: 110 lb Conc. Load at 20.94 TC: 97 lb Conc. Load at 22.94,24.94,26.94 BC: 580 lb Conc. Load at 20.06 BC: 81 lb Conc. Load at 20.94 BC: 78 lb Conc. Load at 22.94,24.94,26.94 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure C=5X6 27'8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.254 1 999 360 Lu: NA Cs: NA VERT(TL): 0.578 1 571 240 Snow Duration: NA HORZ(LL): 0.072 C - - HORZ(TL): 0.165 C Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.692 TPI Std: 2007 Max BC CSI: 0.889 Rep Factors Used: Yes Max Web CSI: 0.995 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE, HS I VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 12'2" co v rn n (V ■1 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1384 / 390 / - ! - / - / 8.0 M 1853 1414 /- /- /- /8.0 Wind reactions based on MWFRS B Min Brg Width Req = 1.6 M Min Brg Width Req = 2.2 Bearings B & M are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 45 - 26 D - E 942 - 4170 B - C 585 - 2207 E - F 942 - 4170 C - D 553 - 2188 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B- K 1873 -461 1- H 4787 -1130 I K- J 4775 -1133 H- G 28 - 9 J - 1 4775 -1133 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp A- L 0 0 D- H 200 - 675 C - K 1435 - 206 E - H 313 - 525 K - D 721 - 3095 H - F 4409 - 993 D- I 191 0 F- G 446 -1726 -WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT' FURN)SH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety. Information, byy TPI and SBCA) for safety practices prior to performing these functions. Installers shall prov BCSL Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall I d;id ceiling Locations shown for permanent :ateral restraint of webs shall have bracing installed per BCSI sections I 'le. Apply plates to each face of truss and position as shown above and on the Joint -Details, unless noted otherw 60A-Z for standard plate positions. a division of 1 HNJV I NI ,1, or tor r icates acceptance ng for any structure failure to build the 3670 COMMERCE CENTER I or cover page SEBRING, FL 33870 ,n. The sui ability (863)385-8242 Jab Number: 84828 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Truss Label: D4 Ply: 1 SEQN: 26947 / T35 / COMN Qty:4 FROM: DRW: Wgt:102.21bs I ... / 12/21 /2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BOLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 01 12' 12' Ea4X4 24' r-- 2' — 8'6-1/2" = 3'5-1/2" — i 3'5-1/2" F 8'6-1/2" Wind Criteria Wind Stdi ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h/2 to It C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 :132 2x4 SP #2: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/3012013 by ALSC Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide hanger or special connection at right end of truss for 1061 lbs. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Sid: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.282 1 999 360 VERT(TL): 0.644 1 442 240 HORZ(LL): -0.117 G - - HORZ(TL): -0.267 G Creep Factor: 1.5 Max TC CSI: 0.480 Max BC CSI: 0.532 Max Web CSI: 0.091 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc,R /U /Rw /Rh /RL /W B 1171 /286 /601 /- /213 /8.0 H 1061 / 235 / 500 / - / - / - Wind reactions based on MWFRS B Min Brg Width Req = 1.5 H Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens, Comp A-B 45 0 E-F 117 -132 B - C 640 -1820 F - G 703 -1477 C - D 681 -1479 G - H 667 -1817 D-E 137 -134 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 1529 - 449 J - 1 1535 - 447 K - J 1535 - 447 1 - H 1529 - 449 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-L 0 0 E-M 139 -59 C- K 404 0 M- F 685 -1585 D- M 685 -1585 I- G 404 0 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Buildini t Safety. Information, by TP! an fabricating, for safety practices prior to performing these functions. Installers shall provide temporary. BCSI. Unless noted olhermse,top chord shall have properly attached structural sheathing and bottom chord shall have a pro erl )j!d ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or �10 �"'DW)P ,e. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Kefer to WOOD STEEL OR TIMBER BOA-Z for standard plate positions. ROOF bR FLOOR TRUSSES vision Of ITW Building�Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pap , , SEBRING, FL 33870 drawing indicates acceptance 'of rofessiona engineeringg responsibility solely for the design shown. The suifability (BRING, FL 33 r'f this drawing for any structure is the responsibility of the 6uildinq Desiqner oer ANSI/TPI 1 Sec.2. Job Number: 84828 Ply: 1 SEQN: 27124 / T23 / HIPS /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: D3 Wgt: 102.2 Ibs I .. / ... 12/21/2017 io av'ic 174 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " i 10'4" 3'4" f 10'4" 24' �-- 2' -{ 8'6-1/2" 3'5-1/2" i— 3'5-1/2" 8'6-1/2" Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk CEtegory: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi* 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 :T2 2x4 SP #2: Bot chord 2x4 SP M-31 :132 2x4 SP #2: Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 byALSC Special Loads --(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 plf at 24.00 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 8.00 BC: From 60 plf at 8.00 to 60 plf at 16.00 BC: From 20 plf at 16.00 to 20 plf at 24.00 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide hanger or special connection at right end of truss for 1063 Ibs. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.235 J 999 360 VERT(TL): 0.644 J 442 240 HORZ(LL): -0.096 H - - HORZ(TL): -0.264 H Creep Factor: 1.5 Max TC CSI: 0.537 Max BC CSI: 0.589 Max Web CSI: 0.091 Mfg Specified Camber: VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 1173 / 346 / 603 / - / 188 / 8.0 1 1063 / 283 / 502 ! - / - / - Wind reactions based on MWFRS B Min Brg Width Req = 1.5 1 Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - B 45 - 26 E - F 137 - 28 B - C 700 -1829 F - G 162 -149 C - D 744 -1488 G - H 757 -1486 D - E 187 -152 H - 1 724 -1827 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 1540 - 501 K - J 1546 - 500 L - K 1546 - 500 J - 1 1540 - 501 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A- M 0 0 N- O 700 -1624 C- L 405 0 O- F 135 - 77 D - N 708 -1651 O - G 715 -1650 E- N 141 - 82 J- H 404 0 -WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI -IMPORTANT"' FURN3H THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, b TF'I and SBCA) for safety practices prior to performing these functions. Installers shall rovide temporary per SCSI. Unless noted ol{herwise,top chord shall have properly attached structural sheathin and bottom chord shall have a properg d ri id ceiling Locations shown forpermanent lateral restraint of webs shall have bracing ins�alled per BCSI sections B3, B7 or 810 COSTA O PO ATION cabgle. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. i2er to WOOD STEEL OR TIMBER is 160A-Z for standard plate positions. / ROOF A FLOOR TRUSSES a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER yo�VE conformance with ANSI/ I PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page .. SEBRING, FL 33870 this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability (863)385-8242 ;e of this drawing for any structure is the responsibility of the Building Designer Per ANSI/TPI 1 Sec.2. i Job Number: 84828 Ply: 1 1 SEQN: 26167 / T7 / HIPM /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: D2 Wgt: 124.6 Ibs .. / ... 12/21/2017 91101, 14'2" 2' F 66-1/2" Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category- II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 3CDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 :132 2x4 SP #2: Webs 2x4 SP #2 :W3 2x4 SP M-31: :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Bracing (a) 1x4 #2 SYP,HF,OR SPF "T" reinforcement. 80% length of web member. Attach with Bd Box or Gun (0.113"x2.5",min.)nails @ 6" OC. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 pif at -2.13 to 56 plf at 24.00 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 8.00 BC: From 60 plf at 8.00 to 60 pIf at 16.00 BC: From 20 plf at 16.00 to 20 plf at 24.00 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 1057 Ibs. 24' 3'5-1/2" - --Lj 4' L 8' �I Snow Criteria (Pg,Pf In PSF) Defl/CSI Criteria ♦Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.352 K 813 360 B 1178 / 348 / 640 / - / 231 / 8.0 Lu: NA Cs: NA VERT(TL): 0.962 K 297 240 H 1057 / 282 / 453 / - / - / - Snow Duration: NA HORZ(LL): 0.173 C - - Wind reactions based on MWFRS HORZ(TL): 0.474 C B Min Brig Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 H Min Brg Width Req = - Bldg Code: FBC 2014 RES Max TC CS 1: 0.615 Bearing B is a rigid surface. TPI Sid: 2007 Max BC CSi: 0.695 Rep Factors Used: Yes Max Web CSI: 0.954 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 45 -26 D - E 366 - 934 WAVE, HS VIEW Ver: 17.02.01 A.1114.21 B - C 588 -1750 E - F 329 -882 C - D 647 -1432 F - G 605 -1339 RICHARD A. SIVER P.E. #65698 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating. handling. shiooina. installina and bracing. Refer to and follow the latest - Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - K 1458 - 680 J - 1 1463 - 678 K- J 1463 - 678 1- H 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-L 0 0 F-N 451 -457 C-K 341 0 N-I 462 -461 D - M 451 - 982 I - G 1594 - 720 E - M 217 - 59 G - H 558 -1033 M - N 435 - 948 of a flg la Ceinn Locations snown for permanent lateral restraint of webs Shall nave bracin mStallea per BGSI sections B3, B7 -Or B10- SCOSTA CORPORATION icable. Appfy Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise, kefer to WOOD STEEL OR TIMBER Is 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW BuildingComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling} shipping, installation and bracing of trussesA seal on this drawing or cover pagge SEBRING, FL 33870 this drawing indicates acceptance of pro essiona engineering responsibility solely for the design shown. The sWabllity (863)3B5-8242 le of this yawing for any structure is the responsibility of the building Designer per ANSI/TPI 1 Sec.2. r JoVNumber: 84828 Ply: 1 SEQN: 26169 / T14 / HIPM /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: D1 Wgt: 126.0lbs .. / ... 12/21/2017 r 7'10" 24' 16'2" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): 0.122 D 999 360 B 1971 / 525 ! - ! - / - / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.289 D 991 240 F 2112 / 528- BCDL: 10.00 Risk Category: II EXP: BMean Snow Duration: NA HORZ(LL): 0.030 F - - Wind reactions based on MWFRS Des Ld: 37.00 Height: 15.00 ft HORZ(TL): 0.072 F - - B Min Brg Width Req = 1.4 NCBCLL: 0.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 F Min Brg Width Req = - Soffit: 10.00 BCDL: 6.'0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.974 Bearing B is a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2007 Max BC CSI: 0.625 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: No Max Web CSI: 0.682 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: NA FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Plate Type(s): A - B 60 -26 C - D 794 -3173 Wind Duration: 1.60 WAVE, HS VIEW Ver: 17.02.01A.1114.21 B - C 896 -3486 D - E 794 -3172 Lumber Value Set: 13B (Effective 6/1/2013) Maximum Bot Chord Forces Per Ply (Ibs) Top chord 2x4 SP M-31 :T1 2x4 SP #2: Chords Tens.Comp. Chords Tens. Comp. Bot chord 2x4 SP M-31 B - 1 3040 -759 H - G 3070 -758 Webs 2x4 SP #2 :W2 2x4 SP M-31: I - H 3070 - 758 G - F 40 10 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values Maximum Web Forces Per Ply (Ibs) approved 1/30/2013 by ALSC Webs Tens.Comp. Webs Tens. Comp. Loading A- J 3 0 D- G 669 -1157 #1 hip supports 7-10-0 jacks with no webs. C - 1 813 0 G - E 3490 - 873 Left side jacks have 7-10-0 setback with 0-0-0 cant C - G 114 - 40 E - F 620 -196i and 2-1-9 overhang. End jacks have 7-10-0 setback with 0-0-0 cant and 2-1-9 overhang. Right side jacks have 0-0-0 setback with 0-0-0 cant and 0-0-0 overhang. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 2112 lbs. I , RICHARD A. SIVER #65698 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg handling, shi ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Inforineiion, b TPI and'SBCA) for safely practices prior to performing these functions. Installers shall provide temporary bracing er BCSI. Unless rioted o�herwise,top chora shall have properly attached structural sheathing and bottom chord shall have a propperl attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections 133, 87 or B10 SCOSTA CO PO ATION as applicable. Apply Oates to each face of truss and position as shown above and on theJoin Details, unless noted otherwise. kefer to WOOD STEEL OR TIMBER drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES Alpine, a division of ITW Buildingg�Cornponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE truss in conformance with ANSI/TPI 1, or for handling shippin , installation and bracing of trussesA seal on this drawing or cover pa e , , SEBRING, Fl- 33870 listin this drawin indicates acceptance of rofessrona engineering responsibility solely for the design shown. The swig brlrty (863)385-8242 and use of this u�awing for any structure is the responsibility of the t3uilding Designer per ANSI/TPI 1 Sec.2. ! Jotf Number: 84828 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Truss Label: A2 Ply: 1 SEQN: 27112 / T44 / COMN Qty: 3 FROM: DRW: Wgt:98.0lbs I / ... 12/21/2017 ' a3ic Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " rj 2' ---� Wind Criteria Wind Std:• ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: :Rt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC 10• D=4X4 20' �--- 2' —' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.042 J 999 360 B 856 / 73 / 519 / - / 203 / 8.0 Lu: NA Cs: NA VERT(TL): 0.092 J 999 240 F 856 / 73 / 519 / - / - 18.0 Snow Duration: NA HORZ(LL): 0.016 H - - Wind reactions based on MWFRS HORZ(TL): 0.036 H B Min Brg Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 F Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.393 Bearings B & F are a rigid surface. TPI Std: 2007 Max BC CSI: 0.478 Rep Factors Used: Yes Max Web CSI: 0.102 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 45 0 D - E 553 -1094 WAVE VIEW Ver: 17.01.01 0630.09 B - C 559 -1234 E - F 558 -1234 C- D 554 -1094 F- G 45 0 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - J 1051 - 333 1 - H 719 -147 J-1 719 -147 H-F 1051 -370 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-K 0 0 D-H 389 -164 C - J 258 - 238 H - E 258 - 238 J -D 389 -165 L-G 0 0 "WARNING" READ AND FOLLOW ALL NOTES.ON THIS DRAWINGI —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS s require extreme care in fabricatingg handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, b TPI an SE for safety practices prior to performing these functions. Installers shall provide temporary per BCSI. Unless noted o�heiwise,top chord shall have properly attached structural sheathmg and bottom chord shall have a propperi d riggid ceiling Locations shown for ermanent lateral restraint of webs shall have bracingp installed per BCSI sections B3, B7 or B10 SCOSTA O PO ATI icable. Apply pplates to each face ofptruss and position as shown above and on the JoinfDetails, unless noted otherwise. kefer to WOOD STEEL OR TIMB Is 160A-Z fOf standafd plate positions. ROOF bR FLOOR T USi a division of ITW.Building_ Components Group Inc, shall not be responsible for anv deviation from this drawing any failure to build the 3670 COMMERCE CENTER on this drawing or cover pa a .SEBRING, FL 33870 he design shown. The suig bllity, (863)385-8242 T.1 A ._ FIPi 1, or Tor acceptance any structure Jab Number: 84828 Ply: 2 SEQN: 25897 / T32 / COMN 71 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: Al Wgt: 221.2 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " +K:v 1. 10, �- 2'---­1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFR5 Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 'hind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE, HS 2 Complete Trusses Required 10' De6x6 20' Defl/CSI Criteria PP Deflection in loc Udell U# VERT(LL): 0.117 H 999 360 VERT(TL): 0.262 H 903 240 HORZ(LL): 0.039 G - - HORZ(TL): 0.087 G - Creep Factor: 1.5 Max TC CSI: 0.359 Max BC CSI: 0.960 Max Web CSI: 0.411 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 Lumber Value Set: 13B (Effective 6/1/2013). . Top chord 2x4 SP M-31 Bot chord 2x6 SP M-14 Webs 2x4 SP #2 :W3 2x4 SP M-31: :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 byALSC Nailnote Nail Schedule:0.148"x3.25", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 4.50" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads -(Lumber Dur.Fac.=1.25 /Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 plf at 7.90 TC: From 28 plf at 7.90 to 28 plf at 10.00 TC: From 56 plf at 10.00 to 56 plf at 20.00 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 7.90 BC: From 10 plf at 7.90 to 10 plf at 20.00 BC: 2112 lb Conc. Load at 7.90 BC: 1055 lb Conc. Load at 9.90 BC: 1061 lb Conc. Load at 10.40 BC: 1060 lb Conc. Load at 12.40,14.40,16.40,1p.44 RICHARD A. SIVER Purlins P.E. In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 4074 / 1087 / 519 / - / 183 / 8.0 F 5828 / 1467 / 417 / - / - / 8.0 Wind reactions based on MWFRS B Min Brg Width Req = 2.4 F Min Brg Width Req = 3.4 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 22 -13 D - E 950 - 3665 B - C 1091 -4234 E - F 1320 - 5198 C - D 947 - 3657 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - I 3754 - 959 H - G 4596 -1161 1 - H 3741 - 957 G - F 4636 -1169 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-J 0 0 D-H 3127 -767 I - C 439 - 68 H - E 376 -1542 C - H 141 - 559 E - G 1297 - 267 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING "IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS luire extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety. Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingand bottom chord shall have a properl j�id ceiling Locations shown forpermanent lateral restraint of webs shall have bracing insalled per BCSI sections B3, B7 or 610 SCOSTA CORPORATIOIK >le. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER. 60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES vision of ITW Buildingg.Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3570 COMMERCE CENTER DRIVE Iformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page , , SEBRING, FL 33870 drawin indicates acceptance of profess ona engmeerm responsibility solely for the design shown. The sulgabdlty (863)385-8242 A this gnawing for any structure is the responsibility of the Ruilding Designer per ANSI/TPI 1 Sec.2. V Job Number: 84828 Ply: 1 1 SEQN: 25936 / T41 / COMN /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: A4 Wgt: 92.4 Ibs / ... 12/21/2017 I r 10, } 10, avis� Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37,00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: > 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide hanger or special connection at right end of truss for 749 Ibs. D=4X4 20' Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): 0.040 1 999 360 Lu: NA Cs: NA VERT(TL): 0.093 1 999 240 Snow Duration: NA HORZ(LL): 0.016 G - - HORZ(TL): 0.037 G Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.393 TPI Sid: 2007 Max BC CSI: 0.494 Rep Factors Used: Yes Max Web CSI: 0.120 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R I /Rw /Rh /RL /W B 898 / 77 / 518 / - 1 183 / 8.0 F 749 /46 /417 /- /- /- Wind reactions based on MWFRS B Min Brg Width Req = 1.5 F Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A- B 60 0 D- E 636 -1126 B - C 595 -1235 E - F 642 -1267 C - D 590 -1096 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - 1 1050 - 451 H - G 728 - 230 1 - H 728 - 230 G - F 1087 - 474 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp, A-J 3 0 D-G 422 -193 C - 1 261 - 233 G - E 275 = 257 1- D 376 -157 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety Information, b TPI and SBCA) for safety practices prior to performing these functions. Installers shall prov BCSI. Unless noted o{herwise,top chord shall have properly attached structural sheathing and bottom chord shall I id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I e. Appr plates to each face of truss and position as shown above and on the Join Details, unless noted otherw 60A-Z for standard plate positions. a division of n rI , or Tor r acceptance any structure failure to build the 3670 COMMERCE CENTER n r The r pa bili SEBRING, FL 33870 ty (863)385-8242 0 JoITNumber: 84828 Ply: 1 1 SEQN: 27148 / T30 / COMN /SOUTHERN CITY DEVELOPMENT NOSSEN/GOD !BLG Qty: 1 FROM: DRW: Truss Label: A3 Wgt: 92.4 Ibs .. / ... 12/21/2017 0 10' 10' -1 20' Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): 0.041 1 999 360 B 862 177 / 518 / - / 183 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.092 1 999 240 F 751 / 46 / 417 / - / - / 8.0 BCDL: 10.00 Risk Category: li Snow Duration: NA HORZ(LL): 0.016 G - - Wind reactions based on MWFRS Des Ld: 37.00 EXP: B HORZ(TL): 0.037 G B Min Brg Width Req = 1.5 NCBCLL: 10.0,1 Mean Height: 15.00 ft TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 F Min Brg Width Req = 1.5 Soffit: 10.00 3CDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.393 s Bearings B & F are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: > 2h TPI Std: 2007 Max BC CSI: 0.489 Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.119 Maximum Top Chord Forces Per Ply (Ibs) Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. GCpi: 0.18 Plate Type(s): A - B 45 0 D - E 633 -1125 Wind Duration: 1.60 WAVE VIEW Ver: 17.01.01.0630.09 B - C 594 -1245 E - F 639 -1266 Lumber C -'D 589 -1105 Value Set: 13B (Effective 611/2013) Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x4 SP #2 Chords Tens.Comp. Chords Tens. Comp. Webs 2x4 SP #2 B - 1 1061 -450 H - G 730 -229 :Lt Level Return 2x4 SP #2: I - H 730 -229 G - F 1086 -471 Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply (Ibs) Purlins Webs Tens.Comp. Webs Tens. Comp. In lieu of rigid ceiling provide lateral bracing to brace A - J 0 0 D - G 417 -192 BC @ 24" OC C - 1 261 - 239 G - E 275 - 255 I- D 387 -157 RICHARD A. SIVER P.E. #65698 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING "IMPORTANT'" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricatingg handling, shi ping, installing and bracing., Refer to and follow the latest edition of BCSI (Building Went Safety Information, by TPI and'SBCA) for safety practices prior to pertorming these functions. Installers shall provide temporary er BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathin and bottom chord shall have a propperg rid ceiling Locatioris shown for permanent lateral restraint of webs shall have bracin ins�ailed per BCSI sections B3, B7 or 810 SCOSTA CORPORATIC cable. Apply plate- to each face Of truss and position as shown above and on the Joinl9Details, unless noted otherwise. Refer to WOOD STEEL oR TIMB s 160A-Z for standard plate positions. ROOF bR FLOOR TRUSI a division of ITW BuildingComponent: Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSI PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover page . , SEBRING, FL 33870 this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suiTabdlty (663)385-8242 ;e of this yawing for any structure is tple responsibility of the building Designer per ANSI/TPI 1 Sec.2. C, Job Number: 84828 Ply: 1 SEQN: 25941 / T46 / SPEC /SOUTHERN CITY DEVELOPMEN'I' PJOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: B1 Wgt: 75.6 Ibs / ... 12/21/2017 r 9. F 9' D=6X6 12 rD 6 (7 T1 W2 T2 v 1112X4(••) C 1 3 Wd 4(.• 2M °3�� K 1 Jg3X4 B3 H 1-;3X5G 04X4 A L=3X4 1112X4 =4X10 .._M, 131 46 B4 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC U 18, 8'5 1 1!1 4 1! '8" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): 0.051 1 999 360 Lu: NA Cs: NA VERT(TL): 0.133 1 999 240 Snow Duration: NA HORZ(LL): 0.028 F - - HORZ(TL): 0.066 F Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.990 TPI Std: 2007 Max BC CSI: 0.664 Rep Factors Used: Yes Max Web CSI: 0.457 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE I VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 822 / 224 / 496 / - / 168 / 8.0 E 676 / 176 / 393 / - / - / 8.0 B / 311 E / 371 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 E Min Brg Width Req = 1.5 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Cornp._ A- B 60 0 C- D 668 -794 B - C 191 - 340 D - E 669 - 833 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - L 317 -146 J - H 649 - 357 L - K 230 -175 H - G 649 - 357 K - J 1008 - 726 G - F 553 - 344 K -1 754 - 826 F - E 714 -441 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-M 3 0 1-1 320 -157 C- 1 484 - 342 D- H 348 0 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety. Information, b TPI an g'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. r BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper) Waid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise, kefer to 60A-Z for standard plate positions. a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page , . SEBRING, FL 33B70 this of this indicates acceptance of professional engineerin responsibility solely for the design shown. The sul ability (863)385-8242 le of this cawing for any structur is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Joli Number: 84828 Ply: 2 SEQN: 26984 / T13 / SPEC /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: B6 Wgt: 274.4 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 2­-­1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 It Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x8 SP 2400f-2.0E Webs 2x4 SP #2 :W4 2x4 SP M-31: :Lt Level Return 2x4 SP #2: Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Nailnote Nail Schedule:0.148"x3.25', min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 3.75" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid sp!itt;ng. Special Loads -(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at -2.13 to 56 pif at 7.90 TC: From 28 plf at 7.90 to 28 plf at 18.00 BC: From 22 plf at -2.13 to 22 plf at -2.00 BC: From 20 plf at 0.00 to 20 plf at 7.90 BC: From 10 plf at 7.90 to 10 plf at 18.00 PLB: From 20 plf at -1.96 to 20 plf at -0.10 BC: 3380 lb Conc. Load at 7.90 BC: 1466 lb Conc. Load at 9.90,11.90 BC: 1470 lb Conc. Load at 13.90,15.''90 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: No FT/RT:20(0)/l 0(0) Plate Type(s): WAVE, HS Wind 2 Complete Trusses Required Defl/CSI Criteria PP Deflection in loc Udell U# VERT(LL): 0.1071 999 360 VERT(TL): 0.244 1 877 240 HORZ(LL): -0.051 E - - HORZ(TL):-0.117 E - Creep Factor: 1.5 Max TC CSI: 0.770 Max BC CSI: 0.506 Max Web CSI: 0.979 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 Right end vertical not exposed to wind pressure. RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W K 4310 /1162 /- /- /- /8.0 L 6054 /1586 /- /- /- /8.0 Wind reactions based on MWFRS K Min Brg Width Req = 1.5 L Min Brg Width Req = 2.5 Bearings K & L are a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A - B 30 -13 C - D 688 - 2573 B-C 1211 -4565 D-E 13 -20 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - I 4047 -1062 H - G 4004 -1052 1 - H 4004 -1052 G - F 2151 - 570 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp, Webs Tens. Comp. A- J 1 0 G- D 3632 - 935 1 - C 1835 - 432 D - F 889 - 3356 C - G 529 - 2030 E - F 17 -28 "WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWINGI -IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS wire extreme care in fabricatingg handling, shi ing, installing and bracing., Refer to and follow the latest edition of BCSI (Building Safety Information, by TPI and'SECA) for safe�y practices prior to performing these functions. Installers shall provide temporary. r BCSI. Unless noted oiherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro pper! ggI'd ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections 53, 67 or B10 I'd Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. of 1 NI 1, or for In acceptance any sructure this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE on this drawing or cover page SEBRING, FL 33870 hepdesiign shown. The suiFability (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 26012 / T59 / VAL /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: V7 Wgt: 154.0 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 6-15/16" I' I' 1 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing,to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes See applicable standard valley or piggyback details for more requirements. 24'16-12" 132-12" 1 5'4" 6'4" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.012 F 999 360 VERT(TL): 0.028 F 999 240 HORZ(LL): 0.010 J - - HORZ(TL): 0.024 J Creep Factor: 1.5 Max TC CSI: 0.246 Max BC CSI: 0.229 Max Web CSI: 0.170 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 'X4 112X4 ♦ Maximum Reactions (Ibs), or'=PLF Loc R /U /Rw /Rh /RL /W Y" 76 / 19 / 39 /- / 9 / 298 P /210 Wind reactions based on MWFRS Y Min Brg Width Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A-B 190 -221 F-G 314 -160 B-C 164 -172 G-H 312 -52 C-D 192 -132 H-I 176 -48 D - E 299 -104 1 - J 36 - 36 E-F 314 -160 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A-S 218 -169 O-N 15 -6 S-R 230 -173 N-M 11 -4 R-Q 236 -175 M-L 8 -3 Q -P 238 -176 L-K 2 -1 P-0 10 -5 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp B-S 379 -218 F-V 4 -22 C - R 345 - 230 V - W 128 - 23 D-Q 236 -134 W-X 197 -188 E-T 213 -185 W-G 200 -176 T-U 211 -197 X-N 198 -188 T - V 128 - 29 M - H 302 -150 U-0 211 -197 L-I 445 -194 U-X 6 -25 J -K 32 -81 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT"` FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building rt Safety Information, byY TPI and SECA) for safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proppefl a�id ceiling Locations shown for permanent lateral restraint of webs shall have bracingInstalled per BCSI sections B3, B7 or B10 SCOSTA CORPORATION Sle. Apply plates to each face of truss and position as shown above and on the JoinfDetails, unless noted otherwise. kefer to WOOD STEEL OR TIMBER 60A-? for standard plate positions. ROOF bR FLOOR TRUSSES ivision of ITW.BuildinggComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance w'Itn ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page , , SEBRING, FL 33870 drawing indicates acceptance of rotess ona engineering responsibility solely for the design shown. The suitability (863)385-8242 �f this drawing for anj( structure is tie responsibility of the building Desiqner per ANSI/TPI 1 Sec.2. Jog Number: 84828 Ply: 1 1 SEQN: 26023 / T22 / GABL /SOUTHERN CITY DEVELOPMENT 1VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: V9 Wgt: 119.0 Ibs I .. / ... 12/2112017 7W1$" I' 12'10-1I16" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 by ALSC Plating Notes All plates are 2X4 except as noted. Purlins In lieu of rigid ceiling provide lateral bracine to brace BC @ 24" OC Wind Right end vertical not exposed to wind pressure. Additional Notes See standard gable detail for more requirements. G--4X4 18'9-1/2" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl L/# Pf: NA Ce: NA VERT(LL): 0.004 S 999 360 Lu: NA Cs: NA VERT(TL): 0.010 S 999 240 Snow Duration: NA HORZ(LL): -0.063 H - - HORZ(TL):-0.006 H Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.096 TPI Std: 2007 Max BC CSI: 0.077 Rep Factors Used: Yes Max Web CSI: 0.069 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 PLATING NOTES All plates are 2X4 except as noted. RICHARD A. SIVER P.E. #65698 5'4" —� T 0 P 1 ♦ Maximum Reactions (Ibs), or'=PLF Loc R /U /Rw /Rh /RL /W T' 76 /19 ./41 /- /10 /225 Wind reactions based on MWFRS T Min Brg Width Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 140 -182 F-G 161 -58 B-C 118 -151 G-H 164 -44 C-D 106 -119 H-1 93 -24 D-E 90 -90 1-1 21 -12 E - F 98 - 74 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A-S 183 -126 0-N 4 -3 S-R 189 -130 N-M 4 -3 R-Q 192 -131 M-L 2 -1 Q-P 194 -132 L-K 0 0 P-0 2 -2 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp B - S 177 -155 G - N 23 - 96 C - R 106 - 95 M - H 176 -126 D-Q 113 -113 L-I 148 -97 E-P 110 -107 J -K 34 -27 F-0 179 -128 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS I require extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Went Safety Information, b TPI ancf'SBCA.) for safety practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propper] p riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracing insgalled per BCSI sections B3, B7 or 810 SCOSTA CO]ZPO ATI cable. Apply plates to each face of truss and position as shown above and on the JointDetails, unless noted otherwise. hefer to woo0 STEEL OR TIMBI Is 160A-Z for standard plate positions. ROOF bR FLOOR TRMB usi a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 this drawing indicates acceptance of Professional engineering responsibility solely for the design shown. The suitability (863)385-8242 e of this yawing for any structure is the responsibility of the building Designer per ANSIITPI 1 Sec.2. R Job Number: 84828 Ply: 1 1 SEQN: 26017 / T2 / GABL /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: E1 Wgt: 99.4 Ibs I .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 00 2, 9. i 9, F=4X4 LB„ L 16,8„ 81 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Plating Notes All plates are 2X4 except as noted. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes See standard and / or structural gable details for more requirements. 18, Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.002 Q 934 360 B 301 / 86 / 169 /- / 168 / 8.0 Lu: NA Cs: NA VERT(TL): 0.004 Q 400 240 B• 65 / 19 / 33 / - / - / 199 Snow Duration: NA HORZ(LL): 0.002 K - - J 105 / 6 / 54 / - / - 18.0 HORZ(TL): 0.003 K Wind reactions based on MWFRS Code / Misc Criteria Creep Factor: 1.5 B Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.485 B Min Brg Width Req = - TPI Std: 2007 Max BC CSI: 0.126 J Min Brg Width Req = 1.5 Rep Factors Used: Yes Max Web CSI: 0.042 Bearings B, B, & J are a rigid surface. FT/RT:20(0)/l0(0) Mfg Specified Camber: Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) WAVE VIEW Ver: 17.02.01A.1 1 14.21 Chords Tens.Comp. Chords Tens. Comp. A-B 60 0 F-G 262 -31 B-C 90 -51 G-H 173 -26 C - D 98 - 30 H - I 109 - 35 D - E 146 - 27 I - J 25 -97 E-F 241 -31 PLATING NOTES All plates are 2X4 except as noted. RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B-Q 140 0 N-M 152 0 Q-P 145 0 M-L 147 0 P-O 149 0 L-K 143 0 O-N 152 0 K-J 134 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-R 3 0 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp C-Q 157 -97 M-G 291 -127 D-P 173 -111 L-H 149 -97 E - O 288 -125 K - 1 301 -146 F-N 0 -93 -WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING[ "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of quire Information, b TPI antl'SBCA) for safety practices prior to performing these functions. Installers shall prov r BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall I dgid ceiling Locations shown for permanent :ateral restraint of webs shall have bracing ins ailed per BCSI sections I 'le. Apply plates to each face of truss and position as shown above and on the Join gDetallS, unless noted otherw 60A-Z for standard plate positions. a division of 'IYI1,ortor h acceptance any sructure this drawing,any failure to build the 3670 COMMERCE CENTER C;RIVE on this drawing or cover page , , SEBRING, FL 33870 heodesignshown. The sulablllty (863)385-8242 Job Number: 84828 /SOUTHERN CITY DEVELOPMENT iVOSSEN/GOD /BLG Truss Label: V8 Ply: 1 SEQN: 27446 / T60 / GABL Qty: 1 FROM: DRW: Wgt:95.2lbs / ,,, 12/21/2017 T 1 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 7gllf' II 91-1/16" 11 Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 It TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 byALSC Plating Notes All plates are 2X4 except as noted. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes See standard gable detail for more requirements. 9'3-1/16" 7 7/41, 19,9" 7'10-1/2" 2' -- 1 2' - I 7'10-1/2" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE PLATING NOTES All plates are 2X4 except as noted. Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.007 P 999 360 VERT(TL): 0.017 P 999 240 HORZ(LL): 0.002 G - - HORZ(TL): 0.006 G Creep Factor: 1.5 Max TC CSI: 0.179 Max BC CSI: 0.152 Max Web CSI: 0.054 Mfg Specified Camber: VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs), or'=PLF Loc R /U /Rw /Rh /RL /W T' 76 / 18 / 35 /- / 7 / 236 Wind reactions based on MWFRS T Min Brg Width Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A-B 60 -105 E-F 217 -108 B - C 83 - 98 F - G 136 - 77 C - D 136 - 77 G - H 83 - 98 D-E 217 -108 H-1 60 -105 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp A - P 145 - 57 M - L 162 - 64 P-O 157 -61 L-K 160 -61 O-N 160 -61 K-J 157 -61 N - M 162 - 64 J - 1 145 - 57 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. Q-R 19 0 R-S 19 0 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp B - P 326 -183 S - L 277 -164 C - O 129 - 67 S - F 276 -152 D - Q 276 -152 K - G 129 - 67 Q - N 277 -164 J - H 326 -183 E-R 2 -22 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT*' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing., Refer to and follow the latest edition of BCSI (Buildin) t Safety. Information, byy TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathingg and bottom chord shall have a propperl id ceiling Locations shown for permanent lateral restraint of webs shall have bracing msialled per BCSI sections B3, B7 or 810 SCOSTA CO P(1R ATTtIN e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WooO STEEL OR TIMBER 60A-Z for standard plate positions. ROOF bR FLOOR TRUSSES vision of ITW BuildiaComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE iformance with ANSI/T�: 11, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa gge SMMERC, C NTE drawin Indicates acceptance of professional engineering responsibility solely for the design shown. The suiFability (aRING, -824z �f this gnawing for any structure is the responsibility of the building Designer per ANSIITPI 1 Or. Job Number: 84828 /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Truss Label: V10 Ply: 1 SEQN: 27414 / T48 / GABL Qty: 1 FROM: DRW: Wgt:77.01bs ... / 12/21 /2017 11 7f7/16„ 1 7'6-1/16" D=4X4 16'3" 7'6-1/16" 7r7/16„ �f j -- 6'1-1/2" '}' 2' ---1 2' i- 61-1/2" Loading Criteria (psf) I Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.U0 SCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 byALSC Plating Notes All plates are 2X4 except as noted. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes See standard gable detail for more requirements. r Snow Criteria (Pg,Pf in PSF) I Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or `=PLF Pg: NA Ct: NA CAT: NAI PP Deflection in loc Udefl U# I Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.007 H 999 360 N' 76 / 18 / 35 /- 17 / 194 Lu: NA Cs: NA VERT(TL): 0.016 H 999 240 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): -0.002 H - - N Min Brg Width Req = - HORZ(TL): -0.005 H Bearing A is a rigid surface. Code / Misc Criteria Creep Factor41.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.198 Maximum Top Chord Forces Per Ply (Ibs) TPI Std: 2007 Max BC CSI: 0.169 Chords Tens.Comp. Chords Tens. Comp. Rep Factors Used: Yes Max Web CSI: 0.048 A - B 125 -113 D - E 203 -114 FT/RT:20(0)/10(0) Mfg Specified Camber: B - C 105 -7 E - F 105 -7 Plate Type(s): C - D 203 -114 F - G 125 -114 WAVE VIEW Ver: 17.01.01.0630,09 PLATING NOTES All plates are 2X4 except as noted. RICHARD A. SIVER P.E. #65698 —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating Ah pq ing, shipping, installing. and bracing.. Refer to and follow the latest a division of any ;QL1-1II V1 weus snan nave uracrn rnsiauea per is as shown above and on the Join Details. unless Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Corn,? A-L 157 -90 J-1 158 -91 L - K 166 - 94 I - H 167 - 94 K-J 159 -91 H-G 157 -90 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - M 150 - 32 M - E 150 - 32 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp B - L 345 -179 E - 1 298 -196 K - C 298 -196 H - F 345 -179 D-M 10 -33 of failure to build the 3670 COMMERCE CENTER DRIVE nor The rsua9 bill SEBRING, FL 33870 ty (863)385.8242 t Joti Number: 84828 Ply: 1 SEQN: 26194 / T9 / HIP_ /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: CJ11 Wgt: 56.0 Ibs .. / ... 12/21/2017 378" f--- 2'9-15/16" ---� Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1,25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 it Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/l/2013)' Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 Webs 2x4 SP e.* :Lt Level Return 2x4 SP f2: Lumber value set "13B" uses design values approved 1/30/2013 byALSC Loading Hipjack supports 7-10-0 setback jacks. Jacks up to 7' have no webs. Longer jacks supported to BC. Purlins In lieu of rigid ceiling provide lateral bracing to,brace BC@24"OC Additional Notes Provide hanger or special connection at right end of truss for 447 Ibs. Provide (2) 16d toe -nails at top chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: W Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Sid: 2007 Rep Factors Used: No FT/RT:20(0)/l 0(0) Plate Type(s): WAVE L 11'0-15/16" Defl/CSI Criteria ♦ Maximum Reactions (Ibs) PP Deflection in loc Udell U# Loc R / U / Rw / Rh / RL VERT(LL): 0.043 C 999 360 B 734 / 187 / - / - / - VERT(TL): 0.102 C 999 240 E 447 / 49 / - / 0 / 0 HORZ(LL): 0.010 C - - D 239 / 136 / - /- / - HORZ(TL): 0.025 C - Wind reactions based on MWFRS Creep Factor: 1.5 B Min Brg Width Req = 1.5 Max TC CSI: 0.525 E Min Brg Width Req = - Max BC CSI: 0.409 D Min Brg Width Req = - Max Web CSI: 0.719 Bearing B is a rigid surface. Mfg Specified Camber: /W Maximum Top Chord Forces Per Ply (Ibs) VIEW Ver: 17.02.01A.1114.21 1 Chords Tens.Comp. Chords Tens. Comp. A - B 104 - 25 C - D 80 -108 B - C 245 - 950 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B- G 884 - 238 F- E 0 0 G - F 877 - 247 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A-H 0 0 C-F 253 -901 G-C 140 0 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING] "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Wrequire extreme care in fabricating, handling, shi pmg, installing and bracing. Refer to and follow the latest edition of BCSI (Building ent Safety Information, b TPI anri'SBCA) for safety practices prior to performing these functions. Installers shall Provide temporary Ter BCSI. Unless ,toted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a progp'e d riggid ceiling Locations shown forpermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION cable. Apply plates to each face of truss and position as shown above and on the Join?Details, unless noted otherwise. Refer to WOOD STEEL OR TIMBER IS 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW Buildipl1Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page SEBRING, FL 33870 this drawing, indicates acceptance of pro fesslonat engineering responsibility solely for the design shown. The suigability (863)385-8242 ;e of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Job -Number: 84828 ' I Ply: 1 SEQN: 27011 / T39 / HIP_ /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG City: 1 FROM: DRW: Truss Label: CJ10 Wgt: 43.4 Ibs .. / ... 12/21/2017 �- 1'6.114„ Loading Criteria (psf) Wind Criteria TCLL: 20.0J Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 0.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc, from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 byALSC Loading The following members need concentrated loads at the heel: 0-0-0 span/setback member on the 0-11-8 cant side requires 2 Ibs and the 0-0-0 span/setback member on the 0-11-8 cant side requires 2 lbs. Sub -fascia beam assumptions: 0-0-0 sub -fascia beam on the 0-11-8 cantilever side. 0-0-0 sub -fascia beam on the 0-11-8 cantilever side. Hipjack supports 7-10-0 setback jacks with 0-11-8 cantilever one face; 0-11-8 cantilever opposite face. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf In PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code I Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 8,3„ Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.027 E 999 360 VERT(TL): 0:067 E 999 240 HORZ(LL): 0.005 B - - HORZ(TL): 0.012 B Creep Factor: 1.5 Max TC CSI: 0.526 Max BC CSI: 0.223 Max Web CSI: 0.182 Mfg Specified Camber: VIEW Ver: 17.02.01A.1114.21 P.E. #65698 Ir ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W F 318 /58 /- /- /- /11.3 D 137 /- /71 /- /- /1.5 C 301 /159 /- /- /- /1.5 Wind reactions based on MWFRS F Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing F is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 27 -4 B-C 100 -74 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. F-E 107 -26 E-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - F 99 - 232 B - E 27 -108 ""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT*` FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricatingg handling, shg Ing, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, byy TPI and'SBCA) for safe�y practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro attached rigid ceiling Locations shown forFermanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 SCOSTA CORPORATION as applicable. Apply Agates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to WOOD STEEL R TIMBER drawings 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES Alpine, a division of ITW Buildinc Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE truss in conformance with ANSII}PI 1, or for handling shippin , installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 listing this drawing indicates acceptance of professponal engineering responsibility solely for the design shown. The sui9ability (863)385-8242 and use of this gnawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. • Job Number: 84828 a /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: CJ5A Ply: 1 I SEQN: 26136 / T61 / HIP_ Qty: 3 FROM: Wgt: 30.8 Ibs DRW: 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " T 3.716" 3-5%16" 1 0-W4" �11-5/16"I �— 2'9-15/16" - �- Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2r.4 SP #2 Bot chord 2x6 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/3012013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Left cantilever is exposed to wind Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: N/ Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Code / Misc Criteria Bldg Code: FBC 2014 RES TPI Std: 2007 Rep Factors Used: Yes FT/RT:20(0)/10(0) Plate Type(s): WAVE 5'5-1/16" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.037 D 460 360 VERT(TL): 0.062 D 271 240 HORZ(LL): -0.013 C - - HORZ(TL): -0.022 C - Creep Factor: 1.5 Max TC CSI: 0.397 Max BC CSI: 0.359 Max Web CSI: 0.000 Mfg Specified Camber: VIEW Ver: 17.02. 01 A. 1114.21 RICHARD A. SIVER P.E. #65698 C N CN 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W F 341 /300 /- /- /- /11.3 D 19 /96 /- /- /- /1.5 C 22 /15 /- /- /- /1.5 Wind reactions based on MWFRS F Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing F is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 44 -16 B-C 12 -19 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 5 -2 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 3 0 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING[ "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS reqquiio extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building nent Safety Information, byy TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary per BCSI. Unless noted Uherwise,top chord shall have property attached structural sheathin and bottom chord shall have a propper) d riggid ceiling Locations : hUwn for permanent lateral restraint of webs shall have bracingp ins�alled per BCSI sections B3, B7 or B10 p TA-C--PO ATION cable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. 12efer to WOOD STEEL OR TIMBER Is 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW BuildiaComponents Group Inc, shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page . , SEBRING, FL 33670 this drawing indicates acceptance of professional engmeerincl responsibility solely for the design shown. The suiTabrlrty (BRING, F 3 e of this yawing for any structure is the responsibility of the 6uildina Desianer oer ANSI/TPI 1 Ser_2_ v Jots Number: 84828 Ply: 1 SEQN: 26175 / T37 / HIP_ /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 2 FROM: DRW: Truss Label: CJ513 Wgt: 26.6 Ibs / ... 12/21/2017 •. 3-7 /8 " �L ,rly Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0,Ou BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 0-W4" 12'9-15/16" !o 65-1/16" Wind Criteria. Wind Std: -ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Loading .. Hipjack supports 3-10-0 setback jacks with no webs. Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): -0.005 D HORZ(TL):-0.012 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0,420 TPI Sid: 2007 Max BC CSI: 0.307 Rep Factors Used: No Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE I VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 0 Ci n N '0 N M ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 414 /64 /- /- /- /11.3 D 18 /- 121 /- /- /1.5 C 73 /56 /- /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 83 -10 B-C 24 -38 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS 3 require extreme care in fabricating handling, shi pmg, installing, and bracing. Refer to and follow the latest edition of BCSI (Building Went Safety Information, b TPI an 'SBCA) for safety practices pnor to performing these functions. Installers shall provide temporary r�er BCSI. Unless noted o�herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperg riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B1 SCOSTA CORPORATION icable. Appfy Agates to each face of truss and position as shown above and on the Joinl9Details, unless noted otherwise. 12efer too WOOD STEEL OR TIMBER )s 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW Buildingg Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRh conformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover page SEBRING, FL 33870 this drawin indicates acceptance of ro ess ona engineerin responsibility solely for the design shown. The Sul ability (863)385-8242 re of this gnawing for any structure is responsibility of the �uildgng Designer per ANSI/TPI 1 Sec.2. In JobYNumber: 84828 Ply: 1 SEQN: 27432 / T43 / HIP_ /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: CJ4 Wgt: 19.6 Ibs .. / ... 12/21/20,7 5oq I-- 2'9-15/16" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00.ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP #2 :Lt Level Retui'h 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Left cantilever is exposed to wind Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. 5r -1 3'6-7/16" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.003 D HORZ(TL): -0.006 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.275 TPI Std: 2007 Max BC CSI: 0.196 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 C T (V ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 437 / 151 / 295 / - / 80 / 6.4 D 40 /5 /35 /- /- /1.5 C 11 /32 /39 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) I Chords Tens.Comp. Chords Tens. Comp. A-B 61 0 B-C 21 -48 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 3 0 "WARNING" READ AIND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS requI re extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Went Safrty Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a pro peri d riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 910 SCOSTA CORprlATION icable. Appfy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to WOOD STEEL OR TIMBER Is 160A-Z for Standard plate positions. ROOF ,S FLOOR TRUSSES a division of ITW Buildingp Components Group Inc, shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI/TPI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e , SMMERC, C NTE 3870 this drawing, indicates acceptance of rofessionaf engineerin responsibility solely for the design shown. The suiFability (863)385-8242 ;e of this r7�awing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. 1 Tsoruc b Number: 84828 UTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG ss Label; 'tJ8 Ply: 1 I SEQN: 27138 / T27 / EJAC Qty: 24 FROM: Wgt: 30.8 Ibs DRW: 12/21/2017 4-3/16- 1 �_ 2' f 7'10" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Haight: 15.00 ft NCBCLL: 10.00 TCDL: 4.0' psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwali: not in 4.50 ft GCp!: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-31 Bot chord 2x4 SP M-31 :Lt Level Return 2x4 SP #2: Lumber value set "136" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.015 D HORZ(TL): 0.032 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.318 TPI Std: 2007 Max BC CSI: 0.241 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 C io ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 415 / 89 / 298 /- / 190 / 8.0 D 142 /- /78 /- /- /1.5 C 188 /133 /117 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 45 0 B-C 84 -160 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS uire extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edit!on of BCSI (Bu!id!nl Safety Information, by TPI and'SBCA) for safe practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted oyherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a proper) ggid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, 87 or p10 e. AppTy plate. to each face o truss and position as shown above and on the Joinl9Details, unless noted otherwise. (tefer to 60A-Z for standard plate positions. a division of this drawing,any failure to build the 3670 COMMERCE CENTER on this drawing or cover page SEBRING, FL 33870 he design shown. The suiFability (863)385-8242 TDI 4 Q__ q u Job Number: 84828 Ply: 1 SEQN: 27140 / T25 / JACK /SOUTHERN CITY DEVELOPMENT NOSSEN/CUD /BLG Qty: 3 FROM: DRW: Truss Label: J6 Wgt: 25.2 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " �— 2' -I- 5'8-15/16" Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 It TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "l3B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe-nai;s.at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell L%# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.007 D HORZ(TL): 0.014 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.488 TPI Std: 2007 Max BC CSI: 0.323 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 C ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 341 / 82 / 254 / - / 147 / 8.0 D 102 /- /54 !- /- /1.5 C 132 /95 /80 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 45 0 B-C 59 -129 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS uire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Safety. Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary. BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a progerl id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10 r e. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. kefer to 60A-Z for standard plate positions. a division of dim 1, or Torr acceptance any structure :his drawing,any failure to build the 3670 COMMERCE CENTER on this drawing or cover pa e SEBRING, FL 33870 ieodes�ign shown. The suitability (863)385-8242 0 Job Number: 84828 Ply: 1 TFROM: EQN: 27142 / T10 / EJAC /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 3 DRW: Truss Label: EJ4B Wgt: 21.0 Ibs / ... 12/21/2017 C Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " 4_„ 4) DO Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h to 2h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60' Lumber Value Set: j 3P. (Effective 6/1/2013) Top chord 2x4 SP #2- Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. �i� Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu:,NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.002 D HORZ(TL): 0.006 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.424 TPI Std: 2007 Max BC CSI: 0.190 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 11 M (V 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 300 / 55 / 231 / - / 87 / 8.0 D 78 /- /42 /- !- /1.5 C 97 /47 /57 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 45 0 B-C 44 -103 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 ""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTAIIT- FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS > require extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Went Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary per BCSI. Unless noted othelwise,top chord shall have properly attached structural sheathing and bottom chord shall have a propperg d rigid ceiling Locations shown forpermanent lateral restraint of webs shall have bracing installed per BCSI sections 83, B7 or B10 SCOSTA CORPORATION icable. Apply Agates to each fare of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to WOOD STEEL OR TIMBER is 160A-Z for standard plate positions. ROOF OR FLOOR TRUSSES a division of ITW Building Ccmponents Group Inc, shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling, shipping, installation and bracing of trussesA seal on this drawing or cover paga .. SEBRING, FL 33870 this drawing indicates acceptance of rofessional engineering responsibility solely for the design shown. The sul ability (863)385-8242 ;e of this yawing for any structure is the responsibility of the engineering Designer per ANSI/TPI 1 Sec.2. [Tsr Number: 84828 Ply: 1 SEQN: 27157 / T8 / EJAC UTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: s Label: EJ4C Wgt: 15.4 Ibs / ... 12/21/2017 3M(A' 4'6" 0 1 l- N Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefi U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): NA A 176 / 20 / 108 / - / 91 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): NA C 81 /_ / 48 / - / - / 1.5 BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.004 C B 110 / 78 / 71 ! - ! - / 1.5 Des Lc. 37.00 EXP: B HORZ(TL): 0.010 C - - Wind reactions based on MWFRS Code / Misc Criteria NCBCLL: 10.00 Mean Hei Height: 15.00 ft TCDL: ei psf 4.0 Creep Factor: 1.5 A Min Brg Width Req = 1.5 Soffit: 10.00 BCDL: psf Bldg Code: FBC 2014 RES Max TC CSI: 0.348 C Min Brg Width Req = - Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2007 Max BC CSI: 0.205 B Min Brg Width Req = - Bearing A is a rigid surface. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes � Max Web CSI: 0.000 Loc. from ehdwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber: GCpi: 0.18 Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) „ Wind Duration: 1.60 WAVE Chords Tens.Comp. VIEW Ver: 17.01.01.0630.09 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. RICHARD A. SIVER P.E. #65698 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in, fabricating handling, shipping, installing and bracing. Refer to and follow the latest a division of ' I NI9,.or for r acceptance any structure :stramt or wens snau nave Dracan instauea per is as shown above and on the Join Details, unless A-B 49 -110 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 of failure to build gthe 3670 COMMERCE CENTER DRIVEI nor r pa abili SEBRING, FL 33870 The ty (863)385-8242 Jdb Number: 84828 Ply: 1 1 SEQN: 27595 / T34 / EJAC /SOUTHERN CITY DEVELOPMENt T /VOSSEN/COD /BLG Qty: 10 FROM: DRW: Truss Label: EJ4 Wgt: 18.2 Ibs I .. / ... 12/21/2017 4_3„ 4) Loading Criteria (psf) I Wind Criteria I- 2' } 3'10" TCLL: 20.00 I Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi( 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "138" uses design values approved 1/3012013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. M Snow Criteria (Pg,Pf in PSF) I Defl/CSI Criteria Pg: NA Ct: NA CAT: NAI PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.002 D HORZ(TL): 0.004 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.424 TPI Std: 2007 Max BC CSI: 0.132 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 "WARNING'" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT*" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabricatingg handling, shi ping, installing and bracing., Refer to and follow the latest Went Safety Information, b TPI and'SBCA) for safety practices prior to pertorming these functions. Installers per BCSI. Unless noted oythenNise,top chord shall have properly attached structural sheathing and bottom cI tl riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI icable. Apply plates to each face of truss and position as shown above and on the Joinf9Details, unless not Is 160A-Z for standard plate positions. a division of ITW Buildingg�Components Group Inc. shall not be responsible for any deviation from this drawin conformance,with ANSI PI 1, or for handlinj shipping, installation and bracing of trussesA seal on this dr this drawing indicates acceptance of pro essiona engineerin responsibility solely for the design ;e of this yawing for any structure is the responsibility of the Bquildina Desianer Der ANSI1TPI 1 Ser-_ C T M M 1 EO CM M ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 279 / 78 / 220 / - / 108 / 8.0 D 65 /- /35 /- /- /1.5 C 78 /57 /43 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) I Chords Tens.Comp. Chords Tens. Comp. A-B 45 0 B-C 35 -87 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 failure to build the 3670 COMMERCE CENTER I or cover page .. SEBRING, FL 33870 n. The sui ability (863)385-8242 0 Job Number: 84828 Ply: 1 SEQN: 27227 / T5 / EJAC /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 11 FROM: DRW: Truss Label: EJ4A Wgt: 18.2 Ibs / ... 12/21/2017 4-� 61 4) v �— 2' —�— Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed . BCDL: 10.00 Risk Category: II B Des Ld: 37.00 Mea Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.6C Lumber Value Set: 1.1B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Left cantilever is exposed to wind Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord... C 3'10" n cD M M CV Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.041 D 287 360 F 420 / 95 / 302 / - / 108 / 8.0 Lu: NA Cs: NA VERT(TL): 0.096 D 123 240 D 15 / 58 / 44 / - / - / 1.5 Snow Duration: NA HORZ(LL): -0.023 C - - C 77 / 61 / 34 / - / - / 1.5 HORZ(TL):-0.053 C Wind reactions based on MWFRS Code / Misc Criteria Creep Factor: 1.5 F Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.479 D Min Brg Width Req = - TPI Std: 2007 Max BC CSI: 0.476 C Min Brg Width Req = - Rep Factors Used: Yes Max Web CSI: 0.000 Bearing F is a rigid surface. FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) WAVE VIEW Ver: 17.01.01.0630.09 Chords Tens.Comp. Chords Tens. Comp. A-B 61 0 B-C 34 -101 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - D 240 - 67 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 3 0 '"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS qquire extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety. Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall prov r BCSI. Unless noted o�therwise,top chord shall have properly attached structural sheathing and bottom chord shall I d�id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I 'le. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherw 60A-Z for standard plate positions. a division of failure to build the I or cover pa e ,n. The suig bility SCOSTA CORPORATION WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES 3670 CSEBRING, FLE33870 DRI\ (863)385-8242 n JoU Number: 84828 I Ply: 1 I SEQN: 27144 / T26 / JACK /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 3 FROM: DRW: Truss Label: J4A Wgt: 18.2 Ibs / ... 12/21/2017 4_3„ 0 4) —2''� Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0:00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: BMean '15.00 Height: ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. 3'8-15/16" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defi L/# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.002 D HORZ(TL): 0.004 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.676 TPI Std: 2007 Max BC CSI: 0.125 Rep Factors Used: Yes Max Web CSI: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING[ —IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS 7uire extreme care in fabricating handling, shi �prctcesprIortoperorm1ng ng, installing and bracing. Refer to and follow the latest t Safety Information, b TPi andg'SBCA) for safeaithese functions. InstallersBCSI. Unless noted oherwisetop chord shall ve prperlyattached structuraheathingg and bottomclid ceiling Locationshownfoermanent latel restraintofwebs shall havebracin insjalled per BCSIe. Applytes teach face of trussand posin as shown above and on the Joint9Details, unless no 60A-Z for standard plate positions. vision of ITW.Building_ Components Group Inc, shall not be responsible for anv deviation from this rimwir iI rl "1, or Tor acceptance any structure on Ci N 00 N 1 00 N 1 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 276 /78 /218 /- /106 /8.0 D 64 /- /34 /- /- /1.5 C 75 /55 /41 !- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. A-B 45 0 B-C 34 -120 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 0 0 of failure to buildthe3670 COMMERCE CENTER DRIVE n. r The ser ulfability SEBRING, FL 33870 ty (863)385-8242 Jrib Number: 84828 Ply: 1 SEQN: 27146 / T15 / JACK /SOUTHERN CITY DEVELOPMENT !.VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: J4 Wgt: 25.2lbs .. / ... 12/21/2017 r C 4-3/J' 6" 2-1-9/16" } 5'8-15/16" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or `=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph BCLL: Enclosure: Closed Pf: NA Ce: NA L VERT L): 0.006 D 999 360 ( B' 105 / 20 / 78 / - / 37 / 48.0 0.00 BCDL: 10.00 Risk Category: II Lu: NA Cs: NA VERT TL : 0.012 D 999 240 ( ) D 4 / 10 / 17 / - / - / 1.5 EXP: BMean Snow Duration: NA HORZ(LL): 0.004 D - - C 125 / 95 / 75 / - / - 11.5 Des Ld: 37.00 Height: 15.00 ItHORZ(TL): 0.008 D - - Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 B Min Brg Width Req = - Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.477 D Min Brg Width Req = - Load Duration: 1.25 MWFRS Parallel Dist: h/2 to In TPI Std: 2007 Max BC CSI: 0.209 C Min Brg Width Req = Spacing: 24.0 " P 9� C&C Dist a: 3.00 ft Re Factors Used: Yes P Max Web CSI: 0.000 Bearing B is a rigid surface. Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Mfg Specified Camber: GCpi: 0.18 Plate Type(s): Maximum Top Chord Forces Per PI y (Ibs) Wind Duration: 1.60 WAVE VIEW Ver: 17.01.01.0630.09 Chords Tens.Comp. Chords Tens. Comp. Lumber A- B 45 0 B- C 56 -127 Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x4 SP #2 Chords Tens.Comp. :Lt Level Return 2x4 SP #2: B - D 0 0 Lumber value set "1313" uses design values approved 1/30,2013 by ALSO Maximum Web Forces Per Ply (Ibs) Plating Notes Webs Tens.Comp. All plates are 4X4 except as noted. A - E 0 0 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. PLATING NOTES All plates are 4X4 except as noted. RICHARD A. SIVER P.E. #65698 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLU DIN G THE INSTALLERS quire extreme care in fabricating, handling, shi Ing, installing and bracing. Refer to and follow the latest edition of BCSI t Safety Information, byy TFi anct SBCAj for safe�y practices pnor to performing these functions. Installers shall rovide to BCSI. Unless noted othervvise,top chord shall have properly attached structural sheathing and bottom chord shPall have d ceilingg Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B' 'le. 4pply pplates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. 60A=Z for sta ri"i rd plate positions. a division of Im 1,orfor r acceptance any structure failure to build the 3670 COMMERCE CENTER I or cover page SEBRING, FL 33870 n. The suitability (863)385-8242 ri .166'Number: 84828 Ply: 1 SEQN: 26134 / T33 / EJAC /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: EJ41) Wgt: 14.0 Ibs .. / ... 12/21/2017 4X4(B1) T i 8-3/16" 12 B f` 3'2" T co M tM CV Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): NA A 124 / 11 / 75 / - / 64 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): NA C 62 /- / 35 / - / - / 1.5 BCDL: 10.00 Risk Category: II EXP: BMean Snow Duration: NA HORZ(LL): -0.001 B B 79 / 61 / 50 / - ! - / 1.5 Des Ld: 37.00 Height: 15.00 ft HORZ(TL): 0.002 C Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 A Min Brg Width Req = 1.5 Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.208 C Min Brg Width Req = - Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2007 Max BC CSI: 0.049 B Min Brg Width Req = - Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.000 Bearing A is a rigid surface. Loc. from endwall: not in 9.0o ft FT/RT:20(0)/10(0) Mfg Specified Camber: GCpi: 0.18 Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 WAVE Chords Tens.Comp. VIEW Ver: 17.02. 01 A. 1114.21 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x6 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid :ailing provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. RICHARD A. SIVER P.E. #65698 A-B 35 -86 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 0 0 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INTHE INSTALLERS luire extreme care in fabricatingg handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI t Safety Information, b TPI and'SBCA) `or safety practices pnor to pertorming these functions. Installers shall provide to BCSI. Unless noted oherwise,top chord shall have properly attached structural sheathing and bottom chord shall have id ceiling Locations shown for p rme ent lateral restraint of webs shall have bracing installed per BCSI sections 63, B; e. AppTy plates to each face of truss and position as shown above and on the JoinCDetails, unless noted otherwise. 60A-Z for standard plate positions. a division of any failure to build the 3670 COMMERCE CENTER DRIVE I or cover pa a SEBRING, FL 33870 n. The swig bility (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 27009 / T11 / JACK /SOUTHERN CITY DEVELOPMENT IVOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: J3 Wgt: 9.8 Ibs .. / ... 12/21/2017 12 C 6 � —1-1 1112X4 B `J T. A HB 1'4-11/16" M i d' 1113X5E B1 D 1'8-15/16" --+ T 00 1 co N 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Sid: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): 0.000 B 999 360 E 209 / 86 / 161 / - / - / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.000 B 999 240 D 34 /- / 17 / - / - / 1.5 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): -0.000 B - - C 5 / 34 / 41 / - / 57 / 1.5 Des Ld: 37.00 EXP: BMean Height: 15.00 ft HORZ(TL): 0.000 B Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.0 psf Code / Mise Criteria Creep Factor: 1.5 E Min Brg Width Req = 1.5 Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.216 D Min Br Width Re 9 q = - Load Duration: 1.25 MWFRS Parallel Dist 0 to h/2 TPI Std: 2007 Max BC CSI: 0.012 C MinBrgWidthReq =- Spacing: 24.0 " C&C Dist a: 3.00 ft " Rep Factors Used: Yes Max Web CSI: 0.062 Bearing E is a rigid surface. Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Mfg Specified Camber: 0.1 Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: n: 1.60 WAVE Chords Tens.Comp. Chords Tens. Comp. VIEW Ver: 17.02..1114.21 01A Lumber, A - B 47 0 B - C 169 - 55 Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP M-31 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. E-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - E 351 -192 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI ""'IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS s require extreme care in fabricating, handling, shi mg, installing and bracing. Refer to and follow the latest edition of BCSI (Building Went Safety Information, bVV TPI and'SBCA) for safe�y practices prior to performing these functions. Installers shall provide temporary. per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathin and bottom chord shall have a propperl d rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing insgalled per BCSI sections B3, 67 or 610 SCOSTA CORPO ATION _ icable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. !?efer to WOOD STEEL OR TIMBER Is 160A-Z for standard plate positions. ROOF bR FLOOR TIMBER a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 36R COMMERCE CENTER DRIVE conformance with ANSI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e , , SMMERC, C NTE 3870 this drawing indicates acceptance of professlonai engmeerin responsibility solely for the design shown. The suitability (863)385-8242 le of this gnawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. c Job Number: 84828 Ply: 1 SEQN: 27430 / T50 / EJAC /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 8 FROM: DRW: Truss Label: EJ3 Wgt: 15.4 Ibs / .,. 12/21/2017. Iy T I 3X4(A1) B r; 4- .� fV 4�4A B 1 D M1 E 'tl 0-y1 14" 3P 4" E--- 2' 2'6" —� Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Sid: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 D Des d:: Mean Height: 15.00 ft .00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Left cantilever is exposed to wind Additional Ncies Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): -0.001 D HORZ(TL):-0.003 D Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.393 TPI Sid: 2007 Max BC CSI: 0.105 Rep Factors Used: Yes Max Web CSi: 0.000 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): VIEW Ver: 17.01.01.0630.09 WAVE RICHARD A. SIVER P.E. #65698 ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W B 316 /88 /222 /- /81 /4.5 D 30 /5 /25 /- /- /1.5 C 6 /26 /33 /- /- /1.5 Wind reactions based on MWFRS B Min Brg Width Req = 1.5 D Min Brg Width Req = - C Min Brg Width Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) I Chords Tens.Comp. Chords Tens. Comp. A-B 60 0 B-C 21 -48 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B-D 0 0 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. A-E 3 0 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "*IMPORTANT" FURNISH THIS,DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS require extreme care in fabriatingg'handling, shi ping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Went Safety Information, byy TPI andSBCA) for safety practices prior to performing these functions. Installers shall provide temporary Ber BCSI. Unless noted o7herwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properl rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10 r to SCOSTA CORPORATION Icable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. DefeWOOD STEEL OR TIMBER )s 160A-Z for standard plate positions. ROOF bR FLOOR TRUSSES a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handlingf shipping, installation and bracing of trussesA seal. on this drawing or cover pa e , , SEBRING, FL 33870 this drawing indicates acceptance of pro essiona engineerin responsibility solely for the design shown. The suigability (863)385-8242 ie of this gnawing for any structure is the responsibility of the �uilding Designer per ANSI/TPI 1 Sec.2. Jot Number: 84828 /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: J2 Ply: 1 SEQN: 27553 / T17 / JACK Qty:6 FROM: DRW: Wgt:12.6lbs / ... 12/21/2017 12 6 4-3/p" 4X4 A M 1 3X4(A1) (B g,---- 0T" C i -- 2' 1'8-15/16" --� Il 00 LO I N 9.1 L? C%4 1 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCL'L: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): NA B 237 / 94 / 211 / - / 65 / 8.0 BCLL: 0.00 Enclosure; Closed - Lu: NA Cs: NA VERT(TL): NA D 23 / 13 / 25 / - / - / 1.5 BCDL: 10.00 Risk Category: II EXP' B Snow Duration: NA HORZ(LL): -0.001 D - C 3 / 33 / 35 / - / - / 1.5 Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL):-0.001 D Wind reactions based on MWFRS NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 B Min Brg Width Req = 1.5 Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.678 D Min Br Width Re 9 q = - Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2007 Max BC CSI: 0.143 C Min Brg Width Req = Spacing: 24.0 " C&C Dist a: 3.00 ft Re P Factors Used: Yes Max Web CSI: 0.000 Bearing B is a rigid surface. . Loc. from endwall: Any FT/RT:20(0)/10(0) Mfg Specified Camber: Gtio 0.1 Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 9:60 WAVE 01 VIEW Ver: 17.01..0630.09 Chords Tens.Comp. Chords Tens. Comp. Lumber A - B 45 0 B - C 45 - 32 Value Set: 1.3B.(Effective 6/1/2013) Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x4 SP #2 _ Chords Tens.Comp. :Lt Level Return 2x4 SP #2: B - D 0 0 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply (Ibs) Purlins Webs Tens.Comp. In lieu of rigid ceiling provide lateral bracing to brace A - E 0 0 BC@24"OC Additional Notes Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord RICHARD A. SIVER P.E. #65698 **WARNING"* READ AND FOLLOW ALL NOTES ON THIS DRAWINGI '"IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS reqquire extreme care in fabricating handling, shi pmg, installing and bracing. Refer to and follow the latest nenf Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers per BCSI. Unless noted ogherwise,top chord shall have properly attached structural sheathing and bottom ct d rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI icable. Apply plates to each face of truss and position as shown above and on the Join Details, unless nol Is 160A-Z for standard plate positions. a division of ITW BuildingComponents Group Inc, shall not be responsible for any deviation from this drawin conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this dr this drawingg indicates acceptance of professronai engineering responsibility solely for the design ;e of this drawing for any structure is the responsibility of the building Designer per ANSUTPI 1 Sec. Of ms tsa, ur or tsiu— SC, CORPO ATTnN 7erwise. }Refer to WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES failure to build the 3670 COMMERCE CENTER DRIVE 1 or cover page SEBRING, FL 33870 n. The .IV (863)385-8242 Job Number: 84828 /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: J2A Ply: 1 SEQN: 26066 / T6 ! JACK Qty:6 FROM: DRW: Wgt:14.0lbs .. / ... 12/21/2017 C 12 6=3X4(Al) 00 B T1 T 4-1„ o`O u7 N 0 4X4 A F D N .�, M1 E B1 OT" 8" f ----- 2' 1'8-15/16" --� Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Deft/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind-Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 Speed: 170 mph Pf: NA Ce: NA VERT(LL): 0.000 - 360 F 508 / 230 / 480 ! - / 63 / 8.0 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): 0.000 - 240 D -279 /279 / 148 /- /- / 1.5 BCDL: 1000 Risk Category: II Snow Duration: NA HORZ(LL): -0.004 C C 3 / 30 / 31 / - / - / 1.5 EXP: B Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): -0.008 C Wind reactions based on MWFRS NCBCLL: 10.00 Code / Misc Criteria Creep Factor: 1.5 F Min Brg Width Req = 1.5 TCDL: 6.0 psf D Min Br Width Re Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI:' 0.623 g q = - Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2007 Max BC CSI: 0.253 C Min Brg Width Req = P - Spacing: 24.0 C&C Dist a: 3:00 ft Re Factors Used: Yes Max Web CSI: 0.000 Bearing F is a rigid surface. " Loc. from endwall: Any FT/RT:20(0)/10(0) Mfg Specified Camber: GCpi: 0.18 Plate Type(s): Maximum Top Chord Forces Per Ply (Ibs) Wind Duration: 1.60 WAVE VIEW Ver: 17.02.01A.1114.21 Chords Tens.Comp. Chords Tens. Conycn Lumber A-B 47 -3 B-C 37 -40 Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Maximum Bot Chord Forces Per Ply (Ibs) Bot chord 2x6 SP M-14 Chords Tens.Comp. :Lt Level Return 2x4 SP #2: B - D 285 -50 Lumber value set "l3B" uses design values approved 1/30/2013 by ALSC Maximum Web Forces Per Ply (Ibs) Purlins Webs Tens.Comp. In lieu of rigid ceiling provide lateral bracing to brace A - E 3 0 BC@24"OC Wind Left cantilever is exposed to wind Additional Notes Negative reaction(s) of -279# MAX. from a non -wind load case requires uplift connection. See Maximum Reactions. Provide (2) 16d toe -nails at top chord. Provide (2) 16d toe -nails at bottom chord. RICHARD A. SIVER P.E. #65698 —WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER DRIVE conformance with ANSI PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa e . SEBRING, FL 33870 this drawingg indicates acceptance of . rofess ona engineering responsibility solely for the design shown. The sutgability (863)385-8242 ;e of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Job Number: 84828 Ply: 1 SEQN: 26071 / T47 / SPEC /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 5 FROM: DRW: Truss Label: M1 Wgt: 64.4 Ibs .. / ... 12/21/2017 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 10.00 Load Duration: 1.25 Spacing: 24.0 " awe n 8" �' 1 10,61, i 2' 111,4„ Wind Criteria Wind Std: ASCE 7-10 Speed: 170 mph Enclosure: Closed Risk Category: II EXP: B Mean Height: 15.00 ft TCDL: 4.0 psf BCDL: 6.0 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft QCpi: 0.18 Wind Duiailon: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP M-3'; Bot chord 2x4 SP M-31 Webs 2x4 SP #2 :Lt Level Return 2x4 SP #2: Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Right end vertical not exposed to wind pressure. Left cantilever is exposed to wind l Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.047 F 252 360 H 628 / 107 / 421 / - / 262 / 8.0 Lu: NA Cs: NA VERT(TL): 0.110 F 108 240 1 378 / 158 / 265 / - /- / 8.0 Snow Duration: NA HORZ(LL): -0.027 D - - Wind reactions based on MWFRS HORZ(TL): -0.064 D - H Min Brg Width Req = 1.5 Code / Misc Criteria Creep Factor: 1.5 1 Min Brg Width Req = 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.223 Bearings H & I are a rigid surface. TPI Std: 2007 Max BC CSI: 0.425 Rep Factors Used: Yes Max Web CSI: 0.377 Maximum Top Chord Forces Per Ply (Ibs) FT/RT:20(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp. Plate Type(s): A - B 61 0 C - D 69 -142 WAVE VIEW Ver: 17.02.01A.1114.21 B - C 43 -512 RICHARD A. SIVER P.E. #65698 Maximum Bot Chord Forces Per Ply (Ibs) I Chords Tens.Comp. Chords Tens. Comp. B - F 846 - 325 F - E 426 - 330 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. A- G 3 0 C- E 352 - 454 F - C 194 - 23 D - E 234 -154 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE IN quire extreme care in fabricating handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety Information, b TPI and'SBCA) for safety practices riot to pertorming these functions. Installers shall prov BCSI. Unless noted o�herwise,top chord shall have properl� attached structural sheathing and bottom chord shall id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I e. AppTy plate- to each face of truss.and position as shown above and on the JoiniDetails, unless noted otherw 60A-Z for standard plate positions. a division of Im 1,ortor r acceptance any structure d :his drawing,any failure to build the 3670 COMMERCE CENTER DRIVE on this drawing or cover page SEBRING, FL 33870 ie design shown. The suiFability (663)385-B242 TPI 1 Sec.2. Job Number:s4828 Ply: 1 SEQN: 26073 / T38 / MONO /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: M3 Wgt: 25.2 Ibs / ... 12/21/2017 =4X ' 4'6" Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 'Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 fio h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x8 SP 2400f-2.0E Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Special Loads —(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at 0.00 to 56 plf at 4.50 BC: From 20 plf at 0.00 to • 20 plf at 4.50 BC: 749 lb Conc. Load at 2.56 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Right end ve,fi.::al not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 580 Ibs. a Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.006 C HORZ(TL): 0.013 C Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.213 TPI Std: 2007 Max BC CSI: 0.261 Rep Factors Used: Yes Max Web CSI: 0.030 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 R ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W D 509 /69 /- /- /- /8.0 C 580 /71 /-/- Wind reactions based on MWFRS D Min Brg Width Req = 1.5 C Min Brg Width Req = - Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 34 - 50 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 10 -3 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B-C 49 -98 "WARNING"" READ AND FOLLOW ALL NOTES ON THIS DRAWING] "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of rt Safety. Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall prov r BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall I ,id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I e. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherw 60A-Z for standard plate positions. Ivi i,ortor r acceptance any sructure failure to build the 3670 COMMERCE CENTER DRIVEI 1 or cover page , , SEBRING, FL 33670 ,n. The sui bility (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 26942 / T29 / MONO /SOUTHERN CITY DEVELOPMENT /VOSSEN/GOD /BLG Qty: 1 FROM: DRW: Truss Label: M2 Wgt: 22.4 Ibs I .. / ... 12/21/2017 4X4 Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x6 SP #2 Bot chord 2x8 SP 2400f-2.OE Webs 2x4 SP #2 Lumber value set "136" uses design values approved 1/30/2013 by ALSC Special Loads ----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 56 plf at 0.00 to 56 plf at 3.17 BC: From 20 plf at 0.00 to 20 plf at 3.17 TC: 1421 lb-Gonc. Load at 1.40 BC: 811 lb Conc. Lord at 1.23 Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Wind Right end vertical not exposed to wind pressure. Additional Notes Provide hanger or special connection at right end of truss for 993 Ibs. 4n R T co 1 "' SO 04 312" Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.008 C HORZ(TL): 0.018 C Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.785 TPI Std: 2007 Max BC CSI: 0.276 Rep Factors Used: Yes Max Web CSI: 0.043 FT/RT:20(0)/l0(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.02.01A.1114.21 RICHARD A. SIVER P.E. #65698 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricatingg handling, shi ping, installing and bracing. Refer to and follow the latest edition of ft Safety Information, b TPI and'SBCA) for safety practices pnor to performing these functions. Installers shall prop BCSI. Unless noted o herwise,top chord shall have properly attached structural sheathingg and bottom chord shall d3id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections I 'le. Apply plates to each face of truss and position as shown above and on the Join�Details, unless noted otherw 60A-Z for standard plate positions. ♦ Maximum Reactions (Ibs) Loc R /U /Rw /Rh /RL /W D 1479 / 574 / - / - / - / 8.0 C 993 1363 Wind reactions based on MWFRS D Min Brg Width Req = 1.5 C Min Brg Width Req = - Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 204 - 491 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 15 -5 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - C 157 - 486 nuur uR rLUUK I KUA, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSIf� PI 1, or for handling shipping, installation and bracing of trussesA seal on this drawing or cover pa a SEBRING, FL 33870 this drawing indicates acceptance of rofesslonai engmeerin9 responsibility solely for the design shown. The suiTablllty (BRING, 8z42 e of this yawing for any structure is tpe responsibility of the gUlldina Designer oer ANSI/TPI 1 Roc Jdo Number: 84828 Ply: 1 SEQN: 27440 / T67 / VAL /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 1 FROM: DRW: Truss Label: V6 Wgt: 53.2 Ibs .. / ... 12/21/2017 6 1 15411 " 11'3-1/16" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 15.20 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to'2h Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft 'GCpi: 0.18 Wind Duration:.1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes See applicable standard valley or piggyback details for more requirements. LI 11,10" 1 1 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.006 G 999 360 H' 76 / 8 / 49 /- / 14 Lu: NA Cs: NA VERT(TL): 0.014 G 999 240 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): -0.003 D - - H Min Brg Width Req = - HORZ(TL): -0.006 D Bearing A is a rigid surface. Code / Misc Criteria Creep Factor: 1.5 /141 Bldg Code: FBC 2014 RES Max TC CSI: 0.243 Maximum Top Chord Forces Per Ply (Ibs) TPI Std: 2007 Max BC CSI: 0.164 Chords Tens.Comp. Chords Tens. Comp. Rep Factors Used: Yes Max Web CSI: 0.062 A - B 89 - 325 C - D 40 - 85 FT/RT:20(0)/l0(0) Mfg Specified Camber: B - C 64 -241 Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 Maximum Bot Chord Forces Pe PI Ib RICHARD A. SIVER P.E. #65698 ok"MARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS s require extreme care in fabricating, handling, ship pping, installing and bracing. Refer to and follow the latest nent Safety Information, b fPl and'SBCA) for safety practices prior to performing these functions. Installers Ter BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathing and bottom ct d riggid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per'BCSI icab5le. Apply plates to each face of truss and nosition as shown above and on the Joint Details, unless nol Is 160A-Z for standard plate. positions. a division of ITW_Buildin9 Components GrouD Inc. shall not be resoonsihle for anv rfevintinn frnm this ri—in I m 1, or for n �acce tance any structure on r y ( s) Chords Tens.Comp. Chords Tens. Comp. A - G 329 - 78 F - E 343 - 85 G - F 338 - 82 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B-G 251 -211 D-E 154 -90 C - F 324 - 252 of ms as, bt or bl u— SCOSTA CO PO ATI lerwise. Refer to WOOD STEEL OR TIMB ROOF OR FLOOR TRUS: failure to build the 3670 COMMERCE CENTER 1 or cover page SEBRING, FL 33870 'n. The suitability (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 27438 / T66 / VAL /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG City: 1 FROM: DRW: Truss Label: VS Wgt: 42.0 Ibs .. / ... 12/21/2017 6115/16" f i 94-9/16" -0- /4' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: B Des Ld: 37.00 Mean Heighti15.67 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " i&C Dist a: 3,00 ft Loc. from endwall: not in 9.00 ft 'GCpi: 0.1 a Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 byALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes See applicable standard valley or piggyback details for more requirements. �J 9'11-1/2" r, 1 1 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U • / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.025 E 999 360 F' 76 / 8 / 49 /- / 14 Lu: NA Cs: NA VERT(TL): 0.057 E 999 240 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): 0.006 E - - F Min Brg Width Req = - HORZ(TL): 0.015 E - Bearing A is a rigid surface. Code / Misc Criteria Creep Factor: 1.5 / 119 Bldg Code: FBC 2014 RES Max TC CSI: 0.377 Maximum Top Chord Forces Per Ply (Ibs) TPI Std: 2007 Max BC CSI: 0.290 Chords Tens.Comp. Chords Tens. Comp. Rep Factors Used: Yes Max Web CSI: 0.065 A- B 78 -262 B - C 33 -86 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): I Maximum Bot Chord Forces Per Ply (Ibs) WAVE VIEW Ver: 17.01.01:0630.09 Chords Tens.Comp. Chords Tens. Comp. A - E 293 - 66 E - D 301 - 70 RICHARD A. SIVER P.E. #65698 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - E 369 - 321 C - D 155 - 75 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating handling, shi ping, installing, and bracing. Refer to and follow the latest edition of t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall prov BCSI. Unless noted ovherwise,top chord shall have properly attached structural sheathing and bottom chord shall d ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections I ,60 Apply plates to each face of truss and position .sow above and on the Jo!ngDetails, unless noted otherw 60A-Z for standard plate positions. a division of ' f F9 1, or for r acceptance any structure failure to build the 3670 COMMERCE CENTER I or cover page SEBRING, FL 33870 n. The sui abjlity (863)385-8242 Job Number: 84828 Ply: 1 SEQN: 26382 / T55 / VAL /SOUTHERN CITY DEVELOPMENT NOSSEN/COD /BLG Qty: 3 FROM: DRW: Truss Label: V4 Wgt: 33.6 Ibs / ... 12/21/2017 6,15116" r— t' 7'4-9/16" -ev4• Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Stdr ASCE 7-10 TCDL: -7:?0 Speed: 170 mph BCLL: 0.00 . Enclosure: Closed BCDL: 10.00 Risk Category: II B Des Ld: 37.00 Mean Mean Height: 16.29 ft NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 it Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes See applicable standard valley or piggyback details for more requirements. r� T11-1/2" 1 1 Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W Pf: NA Ce: NA VERT(LL): 0.005 E 999 360 F• 76 / 17 / 48 /- / 19 Lu: NA Cs: NA VERT(TL): 0.013 E 999 240 Wind reactions based on MWFRS Snow Duration: NA HORZ(LL): -0.002 C - - F Min Brg Width Req = - HORZ(TL): 0.003 E Bearing A is a rigid surface. Code / Misc Criteria Creep Factor: 1.5 / 95.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.249 Maximum Top Chord Forces Per Ply (Ibs) TPI Std: 2007 Max BC CSI: 0.171 Chords Tens.Comp. Chords Tens. Comp. Rep Factors Used: Yes Max Web CSI: 0.077 A - B 58 - 235 B - C 37 - 0" FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): Maximum Bot Chord Forces Per Ply (Ibs) WAVE VIEW Ver: 17.01.01.0630.09 Ch d T C Ch d T C RICHARD A. SIVER P.E. #65698 or s ens. omp. or s ens. omp. A - E 242 - 48 E - D 255 - 53 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. B - E 322 - 252 C - D 180 - 90 —WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety. Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall prov - BCSI. Unless noted oytherwise,top chord shall have properly attached structural sheathin and bottom chord shall I d�id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections I >Ie. Apply plates to each face of truss and position as shown above and on the Joinf9Details, unless noted otherw 60A-Z for standard plate positions. a division of t ANb1f i rr - or tor nanoung snippir rcates acceptance of rofessron< ng for any structure is tie respons failure to buildthe3670 COMMERCE CENTER DRIVEI n r The rSulMility 8E(863) 8'5 8242 70 Joo Number: 84828_ Ply: 1 SEQN: 26380 / T54 / VAL /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 3 FROM: Truss Label: V3 Wgt: 22.4 Ibs 6L 5/16" I' 5'4-9/16" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std:, ASCE 7-10 TCDL: 7.00 Speed: 170 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: B Mean Height: 16.79 It NCBCLL: 10.00 TCDL: 4.0 psf Soffit: 10.00 BCDL: 6.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h Spacing: 24.0 " C&C Dist a: 3.00 It Loc. from endwail: not in 9.00 It GCpi: 0.18 Wind Duration: 1.60 Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "'I 3B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC@24"OC Wind Right end vertical not exposed to wind pressure. Additional Notes See applicabia standard�4alley or piggyback details for more requirements. R 5'11-1/2" — Snow Cr.teria (Pg,Pf in PSF) Defl/CSI Criteria Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Pf: NA Ce: NA VERT(LL): NA Lu: NA Cs: NA VERT(TL): NA Snow Duration: NA HORZ(LL): 0.010 C HORZ(TL): 0.023 C Code / Misc Criteria Creep Factor: 1.5 Bldg Code: FBC 2014 RES Max TC CSI: 0.437 TPI Std: 2007 Max BC CSI: 0.352 Rep Factors Used: Yes Max Web CSI: 0.127 FT/RT:20(0)/10(0) Mfg Specified Camber: Plate Type(s): WAVE VIEW Ver: 17.01.01.0630.09 RICHARD A. SIVER P.E. #65698 t zo DRW: ... / ... 12/21/2017 ♦ Maximum Reactions (Ibs), or "=PLF Loc R /U /Rw /Rh /RL /W D' 75 /17 /47 /- /18 /71.5 Wind reactions based on MWFRS D Min Brg Width Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. A - B 44 -108 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. A-C 191 -29 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B-C 241 -139 "WARNING— READ AIJD FOLLOW ALL NOTES ON THIS DRAWING[ —IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS uire extreme care in fabriatingg handling, shi ping, installing and bracing.. Refer to and follow the latest edition of BCSI (Buildin( Safety Information, b TPI anc/'SB r) for safety practices prior to performing these functions. Installers shall provide temporary BCSI. Unless noted oherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properl id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, 67 or p10 e.� App y plates �o etch face: of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to a division of ITW BuilSi Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the 3670 COMMERCE CENTER conformance with ANSI 1, or for handling shippin , installation and bracing of trussesA seal on this drawing or cover pa e , , SEBRING, FL 33870 this drawingq indicates acceptance pf professional engineerin responsibility solely for the design shown. The suitability (863)385-8242 le of this pawing for any structure is the responsibility of the Bquildinq Designer oer ANSI/TPI 1 Sec.2. Job Number: 84828 Ply: 1 SEQN: 26378 / T53 / VAL /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Qty: 5 FROM: DRW: Truss Label: V2 Wgt: 14.0 Ibs / ... 12/21/2017 15/1 -�----- 3'4-9/16" 61 f 3'11-1/2" Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 Wind Criteria Wind Sid: ASCE 7-10 Speed: 170 mph Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA ♦ Maximum Reactions (Ibs), or'=PLF Loc R / U / Rw / Rh / RL / W D' 75 / 15 / 46 /- / 17 / 47.5 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(TL): NA Wind reactions based on MWFRS BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.003 C D Min Brg Width Req = Des Ld: 37.00 EXP: BMean Height: 17.29 ft HORZ(TL): 0.006 C - - Bearing A is a rigid surface. NCBCLL: 10.00 TCDL: 4.0 psf Code / Misc Criteria Creep Factor: 1.5 Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.189 Maximum Top Chord Forces Per Ply (Ibs) Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Sid: 2007 Max BC CSI: 0.151 Chords Tens.Comp. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.053 A - B 32 -73 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber: GCpi: 0.18 Plate Type(s): I Maximum Bot Chord Forces Per Ply (Ibs) Wind Duration: 1.60 WAVE I VIEW Ver: 17.01.01.0630.09 Chords Tens Corn Lumber Value Set: 13B (Effective 6/1/2013) Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Webs 2x4 SP #2 Lumber value set "1313" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide late,,rbl bracing to brace BC@24"OC Additional Notes See applicable standard valley or piggyback details for more requirements. RICHARD A. SIVER P.E. #65698 P A - C 144 - 20 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. B - C 163 - 90 ""WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI "IMPORTANT"'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS qquire extreme care in fabricating, handling, shi ping, installing and bracing. Refer to and follow the latest edition of t Safety Information, b TPI and'SBCA) for safety practices prior to performing these functions. Installers shall prov r BCSI. Unless noted olherwise,top chord shall have properly attached structural sheathing and bottom chord shall I d�id ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections 1 'le. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherw 60A-Z for standard plate positions. a division of 'I el 1, or Tor hanoling V acceptance of erofes any s.ructura.is the res failure to build the Inrheruigg Tsbility SCOSTA CORPORATION WOOD STEEL OR TIMBER ROOF bR FLOOR TRUSSES 3670 COMMERCE CENTER DRIVE SEBRING, FL 33870 (863)385-8242 Jor) Number: 84828 /SOUTHERN CITY DEVELOPMENT /VOSSEN/COD /BLG Truss Label: V1 Ply: 1 Qty: 6 Wgt: 5.6 Ibs 15/1 " 1'4-9/16" --� 12 6 B 4AT1 X4(D1) =1 A" C B1 �-- 1'11-112" ---� SEQN:26376/T49/.VAL FROM: T 1 DRW: ... / ... 12/21 /2017 Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions (Ibs), or'=PLF TCLL: 20.00 Wind Std: ASCE 7-10 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Loc R / U / Rw / Rh / RL / W TCDL: 7.00 BCLL: Speed: 170 mph Enclosure: Closed Pf: NA Ce: NA VERT(LL): 0.006 B 999 360 75 / 1 / /- / 10 / 23.5 0.00 BCDL: 10.00 Risk Cate gory: II Lu: NA Cs: NA TL VERT : 0.014 B 999 240 ( ) Wind d Wind reactions based on MWFRS EXP: B Snow Duration: NA HORZ(LL): 0.002 B - - D Min Brg Width Req = Des Ld: 37.00 ei ei Mean Hght: 15.00 ft 1 HORZ(TL): 0.006 B - - Bearing A is a rigid surface. . 10.00 TCDL: psf Code / Misc Criteria Creep Factor: 1.5 Soffit: 10.00 BCDL: 6.0 psf Bldg Code: FBC 2014 RES Max TC CSI: 0.059 Maximum Top Chord Forces Per Ply (Ibs) Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2007 Max BC CSI: 0.100 Chords Tens.Comp. Spacing: 24.0 " C&C Dist a: 3.00 ft Rep Factors Used: Yes Max Web CSI: 0.000 A B 0 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Mfg Specified Camber: - -21 GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE VIEW Ver: 17.01.01.0630.09 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Lumber Value Set: 13B (Effective 6/1/2013) A- C 64 -10 Top chord 2x4 SP #2 Bot chord 2x4 SP #2 Lumber value set "13B" uses design values approved 1/30/2013 by ALSC Purlins In lieu of rigid ceiling provide lateral bracing to brace BC @ 24" OC Additional Notes See applicable standard valley or piggyback details for more requirements. RICHARD A. SIVER P.E. #65698 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI —IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS f Saf extreme „aa;�„ntiabrp atineq �Ra^d;i fig, shipying^installing and bracing.. Refer to and follow thelatest edition of Nl+ r a�=� vaa i lace or truss ano position as snown above and on the JoinfDetails, unless noted othervviae. ' Refer to a�'v' in w ri AH 11 Is 160A-Z for s andard plate positions. WOOD STEEL OR TIMB ROOF bR FLOOR TRUS a division nc with Building Components Group Inc. shall not be responsible for any deviation from this his draw failure to build the 3670 COMMERCE CENTER conformance with ANSI 1, or for handling' shipping, installation and bracing of trussesA seal on this drawing or cover pa e _ . SEBRING, FL 33870 this drawing Indicates acceptance of pprofessional engineering responsibility solely for the design shown. The suiFablllty (863)385 8242 ;e of this drawing for any structure is tfie responsibility of the Quildino Designer oer ANSI/TPI 1 Spr_7 10'172 9NIobrdS Oaoaiaa>aua mt reao•A4w*upws wunre.�q� ... �dt ��mwrW menu �sy�s q.s pro aeW Sa}ou lv�auae s.4ol' sm aft Lknjx oi4 aaou —A SDOE90W 'R11�41ie3 ST'I SM EEl/G2 3VJ'sna �++d �+e Kwre &a iu F wr fl +xnn is Rua . .+ ELgnu p sM is ,� pro MU uqs- -4 ..ai Arws , WPW 4q.,awg4,a louolssa•;o•ad a. 3SdLS SS 09 'a -I '101 wo '4M0.+P sT1i a3 uop vyup �o �! ry7r,adsaa aq #ou mw 'aR d'4 s�uuodro� �I+Q p- mod agvld p—p—p doi 2-VM se4..,p o; .,ate rout dna0 slusuodwoo 6urppne 0 3Sd 0 0 71 3H �s�ay;� pnw maim •.,a,aa a4a• •w w pm anoga usoW - uoplsoed�, �puo.o,qs q io a�a, �paa a? s+3aP RIddV •+waaWd� sv rota — is leg suoq� Mg .ad Pro w >•+ad�+d +aw U75 sq- io a40.asa+ Iwatvl iummoad .oi usogs suvpv� �aan PA. Ps�po}}v ( v aaoy mw P—lp 2T2001OBnVA ❑M21a 3Sd OT 3SdL OT OT —Ia ❑H p q�p = > P+�pai?a Rf,.da�d away ,row Pip daa asr�+w>a P+iou •tS�e aad eiQuaa�q' tua,adyI apN— mw �+an>na++t•*•w �+oi+ad os mead � d}aias �i (Y71A Pw Idl .Cq wopv�ao �iaivS i�++�+od-9 �1� 7S7e jo uoq{pa a•aaal +4i sollai �dgp'4gproq'Cy;vol+goi 21/91/2 31VCI 3Sd0-0 ST 061 OZ 1a 31 OE l-1 31 Pw -a �ai+a �Qaw pw E4Ila�4 4 &+* �" �mb+� ��u 'NT"'SM 3u MCM13M SHOMMMM TW M 9an"aa snu "SDWU -LM -IItl13a ATTI A 33N MWAV a Snu NO S3Lw TV naTM aW aVM =ENMvna llnnacl 4-ulo dIH louol; ids � � n IM,aa pu3 puoH3 wO440 3 ❑ AalloA paggnl-S In❑ a,aonbS 6upodS all-OA T'XZM -umoys so }n:) paHo.ld ao a.aonbs acl Cow p.aoH:) wo44og bXZM . Aalp p.aoHO wo}}' q,no paHpj 0-,#T paaoxa :ou saop I.HBlaH lo:)I}.aan aHn so Buol so :pIncl aq Cow suods 4a6,ao-1 ++ -p.aoLp doq, aH} jo adols aH} Buolo painsoaw sl Callon ay} H}oauaq ssn,a4. aH} jo p.ao43 do:, aH� Bupo,acl Ao,4 6upods ull and aH} j.oH4. a}oN w)m)K -uBlsap paloas s,,4aaul6u3 uo payloads so 6upods ull.and jo nall ul pasn sassn x� Callon All 4❑ .u61sap paloas s,,4aaul6u3 uo pal jl:)ads aslm.aaH}o so jo -o-o ,1,2 :o sullund • u❑ vol!�ollol_suI ssn.a:. •,(aeon o} .aol ad pallddo 6uIHa pays pa4.o.a 'paHpo44o Al.aado ad rH1.IM pa:)o,acl acl }snw :ps Aallon H}oauaq ssnxa jo p aoH:) dot 010 .9 7 sllou (.S'Z x .ETT'0) xoq p8 H}IM paH:)o}4-o lia}}aq ao apo,46 FINS puo salads awos 'clam ,40 H}Dual %08 'saoo- q .1. txl (Z) Ajddo 'llon .0-,OI Aano slool},aan ao3 '.6-,L uoH} .aa:�oa,a6 sgam Callon lool}.aan 4o- 'paoods Allonba '6upo.4q lo,aa:�ol snonul:�uo:) JO '-:)-o ,9 VO sllou C.S'z x .EII'0) xoq p8 H4-Im paHoo44o 1,4a44acq ao apo.46 FINS puo sapads awos 'qam jo Hp6ual X08 'aoo,aq ,1, Vxl Alddo 'u6lsap paloas s,,4aaul6ua uo pal.4pads ssalu❑ •Buloods wnwix-ow -o-o ,$,2 }o sassn.4:1- 6ul3,.4oddnS (++) 0-0-02 �- 0-0-8 -� tiXZM tiXZM bXZM 'WOW ZT 0-0-4 p,ba.a so AaB.Aol jo 9xa wo,aj }n❑ 001 = I-z)l '3sd S=-l(j 31 pulM '(I •dx3 'BulpllnH ':)u3 }and 'p46IaH uoaW ,OE Hdw 09T OT-L 33SV .a❑ 00'T = I-z>l ',4sd S=Ia 31 pulM '❑ dx3 'BulpllnH ':)u3 ':010d }H6IaH uoaW ,OE Hdw 081 OT-L 33SV .ao j :.ualonlnba ao Ao:pauuoD S'2VH ,ao -6VH ❑❑E[PUI (T) Ll}Im ao uol}oauuoo #09S lHglm ssnxi 6ul}.aoddns AaaAa on Aaeon Hooa Hoo44d )K,)K ,,aa}}aq ,ao Z# 3-3a 'Z#/ T# 3dS 'E# dS bxZ sgaM '.aa44aq .ao z#/T# 3dS uo NZ# dS bxZ puOH❑ 4-OH ,.aa}}aq .ao Z# 3-3(l 'Z#/T# 3dS 'NZ# dS bxZ puoH❑ dol 00'T=-l-zN '3 dx3 'pasoPu3 Alln1.4.And f4-41aH u-oaW ,06 'Lidw 08T 10T-L 33SV - 11*01-ad Aal)'OA CLB WEB BRACE SUBSTITUTION THIS DETAIL IS TO BE USED WHEN CONTINUOUS LATERAL BRACING (CLB) IS SPEMFIED ON A TRUSS DESIGN BUT AN ALTERNATIVE WEB BRACING METHOD IS DESIRED. NOTES: THIS DETAIL. IS ONLY APPLICABLE F012 CHANGING THE SPECIFIED CLB SHOWN ON SINGLE PLY SEALED DESIGNS TO T—BRACING OR SCAB BRACING. ALTERNATIVE BRACING SPECIFIED IN CHART BELOW MAY BE CONSERVATIVE. FOR MINIMUM ALTERNATIVE BRACING, RE —RUN DESIGN WITH APPROPRIATE BRACING. WEB MEMBER SPECIFIED CLB ALTERNATIVE BRACING SIZE BRACING T OR L—BRACE SCAB BRACE 2X9 OR 2X4 1 ROW 2X4 1-2X4 2X8 OR 2X4 2 ROWS 2X6 2-2X4 2X6 1 ROW 2X4 1-2X8 2X6 2 ROWS 2X6 2-2X4(*) 2XB 1 ROW 2X8 1-2X8 2X8 2 ROWS 2X8 2-2X8(*) T—BRACE, I —BRACE AND SCAB BRACE TO BE SAME SPECIES AND GRADE OR BETTER THAN WEB MEMBER UNLESS SPECIFIED OTHERWISE ON ENGINEER'S SEALED DESIGN. (*) CENTER SCAB ON WIDE FACE OF WEB. APPLY (1) SCAB TO EACH FACE OF WEB. I T-BRACING OR T—BRACE L-BRACING: OR L—BRACE APPLY TO EITHER SIDE OF WEB NARROW FACE. ATTACH WITH 10d BOX OR GUN (0.128'z 8.',M M) NAILS. AT 8' O.C. BRACE LS A MINIMLT f 80% OF WEB MEMBER LENGTH T—BRACE L—BRACE SCAB BRACING: APPLY SCAB(S) TO WIDE FACE OF WEB. NO MORE THAN (1) SCAB PER FACE. ATTACH WITH 10d BOX OR GUN (0.128'z S.',MIN) NAILS. AT 8' O.C. BRACE 18 A MINIMUM 80% OF WEB MEMBER LENGTH SCAB BRACE . vm rmlm ANCHORAGE AND RESTRAINT OF LATERAL BRACING THIS IS A DANGEROUS CONDITION SHEATHING FIG. 1 COMPRESSION WE RS, TO PREVENT THIS - L 1 BEFORE AND AFTER� FAILURE. �OBUC�BLG• OR RESTRAIN THE II IATERAL BRACINGI I I I `CONTINUOUS LATERAL BRACING 111 I 1 I USE METHOD SHOWN IN (CLB) MADMAINS SPACING, HUT I I PERIM LA►MAL BUCIWG FIG. 2. SA & SB, OR OF ALL WED MEMBERS AT ANOTHER STRUCTURALLY THE SAYE TIME. Wl&,�/Z-9HEARING SOUND METHOD SPECIFIED FOR TRUSSES BY PROFESSIONAL ENGINEER OR ARCHITECT. FIG. 2 ANCHORAGE HY BUIIAING DESIGNER (OTHER ANCHORAGE PROVISIONS FOR OTHER TYPES OF WALLS). FIG. 3A ,%YYa4 Yd J�IY ANCHORAGE (HY BUILDING DESIGNER) INTO SOLID END AM WALL — EUMITRAINS LATERAL BRACDIG, THEREBY PREVENTING WEB BUCKLING. CLB CLB COMMON WEB DBR MAY TRAVERSE MORE THAN TWO TRUSSES, DEPENDING ON TRUSS HEIGHT. SHEATHING THE DRAWING BELOW (FIG. SB) SHOWS HOW TO RESTRAIN THE CONTINUOUS LATERAL BRAQNG (CLB -En). WHEN ANCHORAGE IS NOT AVAILABLE AS SHOWN IN FIG. 2 THE DIAGONAL BRACE RESTRAINT (DER; - ) MEMBERS ARE 2X4'S, THE ENDS OF WHICH :A, .ATTACHED TO TOP & BOTTOM[ CHORDS. THE DIAGONAL BRACE MAY BE ATTACHED DIRECTLY TO THE CLB OR TO THE WEB OPPOSITE THE CLB. USE THE SAME NAILING SHOWN IN FIG. SA EXAMPLE TRUSSES COMPRESSION WEB, SLOPING OR VERTD OR WEB NEEDING BRACING. FIG. 3B M14 /S OR STUD GRADE DBR IiAIIED TO OPPOSITE SIDE OF WEB AND REPEATED AT APPROIUMATELY 20 FOOT INTERVALS TO RES= LATERAL MOVEMENT. ATTACH TO WEBS WITH (2) 16d COMMON (0462- X 3.6- MIN) NAILS. --fAIWQ" RM AND = OW ALL W= al Un in T - r.ad<a ue a a� m[r r baadlla& a4�ry, m.c nms grad b—I.& ads- to -d M— REF BRACE RESTRAINT T Y � b . by in m WfCQ � ww f- thaw taoauao.. bun—, .baII yo.a. s�,,� >saatw � E ao�.a, oth..a1-. tap ohms aat.B na.. .a �had .earmem t = ma�hofeam a m.n n w . p.w.v •u.•h.a •Wa = `b 4 • • �>sr �: ahP—Mag d r•� °f DATE 1/1/09 DRWG BRCLBANCO109 - .OEM-nr- =M— COLRSACM Building Components Gmup Inc e r Ba9dbr� Ooo�aothe a.a� bo �lfBW) i.II ml e. a�pm�L tm a..rU- It— U t■ d*,- am Amm. to th. 4a- to .Bh »ix m 6Mo.dta�, ddpg" idtaWq k b—Ing d tra-- UWBW a.—d- plot- an mad. d tt0/10AWL (WAAW4 A X AW3 grad• S7/40/= . UM% podUawd - gho .bond m latat DOWIL pp1l.� OWL AXW plat- to -oh h m of grad ..a m thl. d.aahl(.ad ped-rmY as + W� for th. taa- camp—d d.att..ha.a 1L. in6 m. d tbL aompmmt itr a� hdlEbY L th. a-om�0lb d W. a O.rma' par A!@t/RI 1 8— 6 Qh`-BW: wa..Wbopa.am• 1pi �tpfo.tmn: RCi a Ababdrut Accra; = aaal.o•ta.aj Earth Chy, MO 63045 'Cl