HomeMy WebLinkAboutREVIEW COMMENTSf t 41� - Planning & Development Services Building ✓i Code Regulation Division, 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 ,CANNED BY St Lucie Caffi%n REVIEW COMMENTS PROPERTY INFORMATION Address: 6765 Secoya City / State / Zip: Fort Pierce, FI 34951 Owner(s): Wynne Building Corp e1 Parcel #: 1306-111-0001-000/0 Jurisdiction: ST LUCIE COUNTY Zoning: PUD Lot#: 42 Block: 62 APPLICATION INFORMATION Permit Number: 1801-0333 Stories: Automatic Sprinkler System? No Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Matthew Wynne Fax Number: 772-878-0224 Business Name: Wynne Development Corp Business Addr: 8000 S Us 1 Ste 402 Email: Sue@Spanishlakes.Com City / State / Zip: Port St Lucie, A 34952 REVIEWS AND COMMENTS 7( p #-s-c c 'e j,�. pt l5 (� 5. ReviewTvoe Status Reviewed By Date Started Date Comnleted Date Released DOCUMENTS MISSING PENDING Lashahna Ingram / , 4_ q I.NA, 1/16/2018 Comment: 1/16/2018 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW 2/7/2018 Comment: Comment: 2/7/2018 2/7/2018 Comment: Comment: 2f7/2018 2f1/2018 Comment: 2f1/2018 Comment: Comment: 2f7/2018 NEEDS NOC NEEDS RELOCATION OR DEMO PERMIT COMPLETE Lashahna Ingram 1/16/2018 1/16/2018 1/16/2018 INCOMPLETE William Durden 217/2018 THE TRUSS ENGINEERING IS DESIGN TO THE 2014 FLORIDA BUILDING CODE. PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE MANUFACTURES TRUSS DRAWINGS ARE DESIGNED TO THE 2014 FLORIDA BUILDING CODE. PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE LINE VINFORMATION BLOCK OF THE ENERGY CALC'S ARE INCORRECT. SEE SECTION 405.4.2 (1) OF THE 2017 FLORIDA ENERGY CODE. ON THE ENERGY CALC'S, SEE SECTION 9 SUBSECTION B, FRAME -WOOD, EXTERIOR SPECIFIES R-11 INSULATION, PLEASE SEE TABLE 402.1.2 OF THE 2017 FLORIDA ENERGY CODE. INSULATION WITH AN R- VALUE OF R 13 IS REQUIRED IN THIS LOCATION. ENERGY CALC FORM R405-2014 IS AN OUTDATED FORM. ENERGY CALC'S SUBMITTED AFTER DECEMBER 31, 2017 MUST BE SUBMITTED ON R405-2017 FORMS. THE R-VALUE FOR THE SEPARATION WALL BETWEEN THE STRUCTURE AND THE GARAGE SPECIFIES R 11. PLEASE SEE TABLE 402.1.2 OF THE 2017 FLORIDA ENERGY CODE. SEE PAGE 1 OF THE DUCT SYSTEM SUMMERY FROM QUICK CALC'S, INC. THE DUCT SIZES ON THE FORM DOES NOT MATCH THE SUBMITTED DUCT PLANS. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. i !J Planning &,Development Services Building 8 Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 Comment: SEE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT ON PAGE 1 OF 5, PRODUCT APPROVAL NUMBER 12198.3 2/7/2018 HAS NOT BEEN UPDATED FOR THE 2017 FLORIDA BUILDING CODE. PLEASE SUBMIT THE CORRECT PRODUCT APPROVAL NUMBER. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PLEASE SEE PAGE 1 OF 5 THE PERMIT INFORMATION (FORM 100) IS INCORRECT. PLEASE SEE CHAPTER 3 2/7/2018 OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE. Comment: PLEASE PUT ON THE PLANS THE SOIL DENSITY OR SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE 2/7/2018 WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE. Comment: COULD NOT COMPLETE MY REVIEW OF THE DOCUMENTS OR DRAWINGS DUE TO THE INCORRECT 2/7/2018 BUILDING CODE REFERENCES ON THE SUBMITTED DOCUMENTS. PLEASE SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: - PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE 2/7/2018 SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. ZONING REVIEW COMPLETE Angela Huff 1/24/2018 1/24/2018 1/24/2018 Comment: