PROPERTY INFORMATION
Address: 6765 Secoya
City / State / Zip: Fort Pierce, FI 34951
Owner(s):
Wynne Building Corp
e1
Parcel #: 1306-111-0001-000/0 Jurisdiction: ST LUCIE COUNTY
Zoning: PUD Lot#: 42 Block: 62
APPLICATION INFORMATION
Permit Number: 1801-0333 Stories: Automatic Sprinkler System? No
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Matthew Wynne
Fax Number: 772-878-0224
Business Name: Wynne Development Corp
Business Addr: 8000 S Us 1 Ste 402 Email: Sue@Spanishlakes.Com
City / State / Zip: Port St Lucie, A 34952
REVIEWS AND COMMENTS
7(
p #-s-c c 'e j,�. pt l5 (� 5.
ReviewTvoe Status Reviewed By Date Started Date Comnleted Date Released
DOCUMENTS MISSING PENDING Lashahna Ingram / , 4_ q I.NA,
1/16/2018 Comment:
1/16/2018 Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
2/7/2018 Comment:
Comment:
2/7/2018
2/7/2018 Comment:
Comment:
2f7/2018
2f1/2018 Comment:
2f1/2018 Comment:
Comment:
2f7/2018
NEEDS NOC
NEEDS RELOCATION OR DEMO PERMIT
COMPLETE Lashahna Ingram 1/16/2018 1/16/2018 1/16/2018
INCOMPLETE William Durden 217/2018
THE TRUSS ENGINEERING IS DESIGN TO THE 2014 FLORIDA BUILDING CODE. PLEASE FURNISH TRUSS
ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2017 FLORIDA BUILDING CODE
MANUFACTURES TRUSS DRAWINGS ARE DESIGNED TO THE 2014 FLORIDA BUILDING CODE. PLEASE
FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED
BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
LINE VINFORMATION BLOCK OF THE ENERGY CALC'S ARE INCORRECT. SEE SECTION 405.4.2 (1) OF THE
2017 FLORIDA ENERGY CODE.
ON THE ENERGY CALC'S, SEE SECTION 9 SUBSECTION B, FRAME -WOOD, EXTERIOR SPECIFIES R-11
INSULATION, PLEASE SEE TABLE 402.1.2 OF THE 2017 FLORIDA ENERGY CODE. INSULATION WITH AN R-
VALUE OF R 13 IS REQUIRED IN THIS LOCATION.
ENERGY CALC FORM R405-2014 IS AN OUTDATED FORM. ENERGY CALC'S SUBMITTED AFTER DECEMBER
31, 2017 MUST BE SUBMITTED ON R405-2017 FORMS.
THE R-VALUE FOR THE SEPARATION WALL BETWEEN THE STRUCTURE AND THE GARAGE SPECIFIES R
11. PLEASE SEE TABLE 402.1.2 OF THE 2017 FLORIDA ENERGY CODE.
SEE PAGE 1 OF THE DUCT SYSTEM SUMMERY FROM QUICK CALC'S, INC. THE DUCT SIZES ON THE FORM
DOES NOT MATCH THE SUBMITTED DUCT PLANS. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING
CODE.
i
!J
Planning &,Development Services
Building 8 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(772)462-6443
REVIEW COMMENTS
Page 2
Comment:
SEE PRODUCT APPROVAL SUBMITTAL AFFIDAVIT ON PAGE 1 OF 5, PRODUCT APPROVAL NUMBER 12198.3
2/7/2018
HAS NOT BEEN UPDATED FOR THE 2017 FLORIDA BUILDING CODE. PLEASE SUBMIT THE CORRECT
PRODUCT APPROVAL NUMBER. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
Comment:
PLEASE SEE PAGE 1 OF 5 THE PERMIT INFORMATION (FORM 100) IS INCORRECT. PLEASE SEE CHAPTER 3
2/7/2018
OF THE 2017 FLORIDA RESIDENTIAL BUILDING CODE.
Comment:
PLEASE PUT ON THE PLANS THE SOIL DENSITY OR SUBMIT GEOTECHNICAL REPORT IN COMPLIANCE
2/7/2018
WITH R401 OF THE 2017 RESIDENTIAL BUILDING CODE.
Comment:
COULD NOT COMPLETE MY REVIEW OF THE DOCUMENTS OR DRAWINGS DUE TO THE INCORRECT
2/7/2018
BUILDING CODE REFERENCES ON THE SUBMITTED DOCUMENTS. PLEASE SEE CHAPTER 1 SECTION 107
OF THE 2017 FLORIDA BUILDING CODE.
Comment:
- PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE
2/7/2018
SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED
DOCUMENTS.
ZONING REVIEW
COMPLETE Angela Huff 1/24/2018 1/24/2018 1/24/2018
Comment: