HomeMy WebLinkAboutELEVATION CERTIFICATE 8-28-18U,S. DEPARTMENT OF HOMELAND SECURITY
������® �CZ C3
Federai Emergency Management Agency ��
National Flood Insurance. Program
ELEVAl'i0'�CERTIFICATE
Important: Follow the instructions on pages 1-9.
i
OMB. No. 1660-0008
Expiration Date: November 30, 2018
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agenticompany, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number.
BOISCLAIR
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number.
Box No.
10701 SOUTH OCEAN DRIVE #847
City State ZIP Code
JENSEN BEACH FLORIDA 34957
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
LOT 847, HOLIDAY OUT IN AMERICA SECTION D
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL
A5. Latitude/Longitude: Lat. 27°16'20.1" Long. 80°12'28.8" Horizontal Datum: ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 8
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) 965 sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade 2
c) Total net area of flood openings in A8.b 816 sq in
d) Engineered flood openings? ® Yes. ❑ No
A9. For a building with an attached garage:
a) Square footage of attached garage N/A sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade N/A
c) Tctal net area_of flood openings in A9.b N/A sq in
d) Engineered flodd:openings? ❑ Yes ® No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community,Name & Community Number
B2. County Name
B3. State
UNINCORP 120285-- ,,
ST. LUCIE
FLORIDA
B4. Map/Panel
Number
'85. Suffix
86. FIRM Index
Date
B7. FIRM Panel
Effective/
B8. Flood
Zone(s)
B9. Base Flood Elevation(s)
(Zone AO, use Base Flood Depth)
t Z- t k k G
J
V Zi �lC,� Az-
Revised Date
—7e.
LA
B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9:
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ® NAVD 1988 • ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No
Designation Date: N/A ❑ CBRS ❑ OPA
rrRAA
HVIA Form 086-0-33 (/r95)
Replaces all previous editions.
Form Page 1 01/
NATION CERTIFICATE\
OMB No. 1660-0008.
Expiration Date: November,30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number.
10701 SOUTH OCEAN DRIVE #847\
City State ZIP Code
Company NAIC Number
JENSEN BEACH FLORIDA 34957
\
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑\Construction Drawings* ❑ Building Under Construction* ® Finished Construction
*A new Elevation Certificate will be requir d when construction of the building is Complete.
C2. Elevations — Zones Al A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, ARIA, AR/AE, AR/AIA30, AR/AH, AR/AO.
Complete Items C2.a—h below according to\the building diagram specified in Item AT In Puerto Rico only, enter meters.
Benchmark Utilized: 94 77 A02 RM2 FDOT Vertical Datum: NAVD 1988
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source:
that used for the BFF-.
Datum used for building elevations must be the'same as
\ Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4.6 ® feet ❑ meters
8.2 ® feet ❑ meters
b} Top of the next higher floor
c) Bottom of the lowest horizontal structural membe (V Zones only) N/A ❑ feet ❑ meters
d) Attached garage (top of slab) \ N/A ❑ feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 7.0 ® feet ❑ meters
(Describe type of equipment and location in Comments) 4.5
fl Lowest adjacent (finished) grade next to building (LAG) ®feet ❑meters
4.6 ® feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG)
h) Lowest adjacent grade at lowest elevation of deck or stairs, including 4.4 ® feet ❑ meters
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
my best efforts to interpret the data available. I understand that any false
1 certify that the information on this Certificate represents
statement maybe punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ®Yes ❑ No ® Check here if attachments.
Certifier's Name License Number 2546-01-01
EARLE R. STARKEY 4459
Title \
PROFESSIONAL LAND SURVEYOR
Company Name \
ACCURIGHT LAND SURVEYING INC.
Address \
1501 DECKER AVENUE #419
P Code 08/28/2018
City State 14994
STUART FLORIDA PLS #4459
Sig Date Telephone. Ext.
08/28/2018
Copy all pages of this Elevation Certificate and all attachments for (1) community official,\�,2) insurance agenticompany, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
\
- E DOOR SYSTEMS MODEL #1632CS C2-E A/C PLATFORM
A8D CRAWL SPACE
Form Page 2 of
_u .. � cr7itinnc
FEMA Form 086-0-33 (7115)
.Building Photographs
See Instructions for Item A6.
For Insurance' Company Use:
Building Street Address (including Apt., Unit, Suite; and/or Bldg. No) or P.Q. Route and Box No. Policy Number
10701 SOUTH OCEAN DRIVE #847
City State ZIP Code
JENSEN BEACH FLORIDA 34957
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two wilding photographs below according to
the instructions for Item A6. Identify ail ,photographs with: date taken; "Front View" and "Rear View"; and, if required, "Right
Side View" and "Left Side View." If submittin more photographs, than will fit on this page, use the Con#inuabon Page,
following. FRONT 08/28/201g REAR 08/28/2018
h� S
��
�i��y..�-.vy
i��,
5 �hE S�E r^Y ��l���i'� MS, e �'bF � E f ^ - ✓, ��` �dr
( 7 hi Z
yt•"
�tf
,� yoPt � q�l
y i w �rfp d
4 Far § Sk r 1, a } y ti,��,. �""`� �1• 3c N �r .!y y p+'
d it �" F i t r � - r r a u" { i c '? 1 (� � + ai r� a+�".�,, .. �,,,.r^r-.•.�"
j k r t 7 �•p 5
k
III
�( N
S 1
z•SU7i i P � �-
�y
SIDE 08/28/2018
r if61iv1
1
rv.rr rn ran
rum '
r
Certification of Engineered Flood Openings
In accordance with NFIP, FEMA TB 1.08, and ASCE/SE[ 24-05
I hereby certify that the Crawl Space Door Systems flood vents 816CS,12200,1MCS,1616CS,1624CS,1632CS, 2032CS, 2424CS,
and 2436CS are designed in accordance with the requirements of the NFiP "Flood insurance Manual' (2011) to provide automatic
equabatlan of hydrostatic flood forces by aitowing for the entry and exit of floodwaters, when properly lnsta[led and sired as set
forth below. This certification follows the design requirements and specifications established in FEMA Technical Bulletin 1.08,
'Openings In Foundation wails and Walls of Enclosures Below Elected Buildings in Special Flood Hazard Areas", and the ASCE
Standard for "Flood Resistant Design and Construction" (ASCE/SEi 2405). The actual vent opening measurements were determined
and certified by Mr. Christopher Mark Loney, Virginia PE No. 029000. Calculations are based on the spreadsheet formulas, and
'Review of certification of Engineered Flood Openings, dated January 16, 2012" prepared by Dr. Georg Reichard, Associate Professor
of Building Construction, Virginia Tech.
Design Characteristics
Section 2.6.2.2 of ASCE 24 provides an equation to determine the required net area of engineered openings (A,j fora given gndosed
A (Q. This equation is based on the hydraulic formula for the flow rate across sharp edged orifices. I have utilized this equation
to calculate 1) the respected flow rate through the individual openings between louvers; 2) the flow rate through the main frame
opening in case the louver is blown out during a flood event; and 3) the flow rate of water flowing through lower blades following
hydraulic short tube theory. The ultimate maximum total enclosed area (A.) that can be serviced by a single vent has then been
determined by utilizing the lowest flow, rate of the three assessed scenarios for each vent and is listed in Table 1.
These values are based on the following assumptions:
• in absence of reliable data, the rates of rise and fall have been
assumed with 5 feet/hour,
• The (maximum) difference between the exterior and interior
floodwater levels has been assumed with 1 foot during base
flood conditions;
• A factor of safety of 5 has been assumed, which is consistent
with design practices related to protection of life and property;
• The net area oftpenings (A,) as provided by the manufacturer.
Installation Requirements and Limitations
This certification will be voided If the foliowing Installation
•j
Mode!
H x W
[in]
A.
fln'l
A■
[ft=1
El
816CS
8 x 16
106
205
❑
1220CS
12 x 20
237
Soo
0
1232CS
12 x 32
306
64S
❑
1616CS
16 k is
1"
395
❑
1624CS
16 x 24
312
670
1632CS
16 x 3t
408
835
20 x 32
630
1240
L2032cs
2424CS
24 x 24
570
323Q
2436CS
24 x 35
852
1755
requirements and limitations are not enforced:. Table 1 Maximum total enclosed area (A,) that can be
• There shall be a minimum of two openings on different sides of served by each Individual model based on the
each enclosed area; • Tne bottom of each required opening shall be no more than lit given net area of engineered opeMngs (Ao)
aaove the adjacent ground level;
• No temporary [e.g. during cold weather) or permanent solid cover may be placed Into or over the nood vent that would block
the automatic entry or exit of floodwaters at any time,
• Where analysis indicates rates of rise and fall greater than 5 ft/hr, the total enclosed area as given in Table 1 shall be reduced
accordingly to account for the higher rates of rise and fall.
Certifying Desian Professional
NM Yule Steve A. Ciecl, President, Ged & Associates Engineers, Inc.
Address 2950 N 12e1 Avenue, Pensacblajl. 32503
lJcense Florida Prafessional Engineer, IJ o.33658 1
Signature _ f,• Y
No 336M �*
51AME of m Z.
Identification of the Buildin;r and Installed Flood' Vents '(By Others) "�ii;.�NAL;�'j%N
The flood vent models marked in Table i*j are being installed at the foliowing building:
euddrng Address