BLOWER DOOR TEST FORM St Lucie County
House Infiltration Test Certification
Prescriptive and Performance Method
RECEIVED
JUL 1 g 2019
ST. Lucie County, Permitting
Permit #:
Construction: (>9 New Construction — Complete ( ) Existing — Atter Aaaition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = -_3 `1,!F% Test Date:
Volume = vr3, 9 7 4 7
ACH (50) =CFM (50) x 60 /Volume Mechanical Ventilation required less tha► XACH
Passing results must be & ACH (50) or less fi4lpass ( ) Fall
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tc�,s_ted with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing; Companv All Purpose Consultants LLC 2875 Duquesne Cir., WPB, FL 33409
Company Name: Address:
I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in act ante wi cti .4.1.2 Climate Zone 2.
Signature: RESNET RIN S 3807286
Printed Name: Richard A. Avon
License/Certification #: RESNET RIN # 3807286 PURPOSE
BLOWER DOOR CERTIFICATION
APE
ALL PURPOSE CONSULTANTS
Retrotec Certification for Single Blower Door Opqra66n-(D . M 1 3 2) . -1
for
Rithard-Avon
Certificate #-. 17997245
- ieLter. as the m,anviedurer taitiffeith . Hhe above flamed person has . a . Dm . plated the training
and.lbspmfidaittin the usaWketratetBlaMpolliswith M62diffiseskrthe'
tal' '
gauPull— 019
measuring alrieftSe In residential infits
Jun e -19, 2027
CetbTwd an Car- Gerrgn PmOenl afRetcleckr
Retroted Cirti.ficbrtion for Residential Duff4iter-Op6i on-(D2)
for
-Avon PicNar-d'on
Certificate 17999048
Revo=-as The amnufacturer, offfiffes . that thi;kbOve named person bas b0hlplated the trailing ow4
and is pmIldentin the use Retr6ter Duffestets Wth Dh32 cg_qftd gaitesibr. the"PMpase 61?;"
measudng �dyct leal:4i in res defilW'&Wts
June 182017
- Cerfilledon
AM Purpose Consuftants I.M.
14.1OZ- Al .71149'
ph,. (�61) 644-2829
email: aR!L.9 Vidoud.com websits: www.resnetflorida.com