Certification for Design. Load Compliance
Project Name:. MQ>; C-t \ � knd
Project Address: 80\5 `C>`C1�C>�� OR L,.0. S 1y. WK-V Sc'-k.A u4C- =L.L
Permit d: �g y 1 Occupancy Type: �" Z-- Construction Type: PC -5
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior. ren ovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building. official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 'Z-O X7 Code V" Edition, with 20 Supplements using ASCE 7-10
2. Structure Designed as (check.one): Enclosed _Partially Enclosed _Open
3. Risk Category: _1 V/ II „111 — IV Exposure Category: _ _B V/C _D
4. Design Wind Velocity 170 mph �ASD _LRFD End Zone Width: _ �� ft
5. Mean Roof Height _ 9' 5 q ft Roof Pitch: _:12 Parapet: _ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15WRH, clearly label on all plan openings):
-1415 .Zone 1:-,.�z9.5 Zone 2. - q4.1 Zone 3: -61.2. Zone 4: - g3•to Zone S: 3, S Garage: _
7. Design Loads:. Floor: t-iQ PSF Roof/Dead: O PSF Roof/Live::_24 Balcony: C)%P� PSF
Dock: f)IVk PSF Deck: n A PSF Stairs: � jA PSF Fence: 01k PSF Railings: Iln PSF
8. Were Shear Walls Considered For Structure? /Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? ✓ Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: ' .600 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the :attached plans 8i specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified: --
Print Name C �rt & Co. Cert Auth.
z frxs ,K
Signature, Date; and Seal �-�
Company Name & Address
A�e .. I " 00 a