Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE=� SCA RECEIVED BY St Lucie County MAR 2' 8 2018 ' ' ' =e Planning& Development Services.. ejeQryr�kting Department Building & Code Regulations vlsi I •p 2300 Virginia Avenue, Fort Pierce, FL 3498 — j d �53 COU 11tj/, FL Certification for Design. Load Compliance Project Name:. MQ>; C-t \ � knd Project Address: 80\5 `C>`C1�C>�� OR L,.0. S 1y. WK-V Sc'-k.A u4C- =L.L Permit d: �g y 1 Occupancy Type: �" Z-- Construction Type: PC -5 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior. ren ovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building. official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 'Z-O X7 Code V" Edition, with 20 Supplements using ASCE 7-10 2. Structure Designed as (check.one): Enclosed _Partially Enclosed _Open 3. Risk Category: _1 V/ II „111 — IV Exposure Category: _ _B V/C _D 4. Design Wind Velocity 170 mph �ASD _LRFD End Zone Width: _ �� ft 5. Mean Roof Height _ 9' 5 q ft Roof Pitch: _:12 Parapet: _ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15WRH, clearly label on all plan openings): -1415 .Zone 1:-,.�z9.5 Zone 2. - q4.1 Zone 3: -61.2. Zone 4: - g3•to Zone S: 3, S Garage: _ 7. Design Loads:. Floor: t-iQ PSF Roof/Dead: O PSF Roof/Live::_24 Balcony: C)%P� PSF Dock: f)IVk PSF Deck: n A PSF Stairs: � jA PSF Fence: 01k PSF Railings: Iln PSF 8. Were Shear Walls Considered For Structure? /Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? ✓ Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: ' .600 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the :attached plans 8i specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: -- Print Name C �rt & Co. Cert Auth. z frxs ,K Signature, Date; and Seal �-� Company Name & Address A�e .. I " 00 a