HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILESFlorida Building Code Online Page 1 of 2
SCANNED BY -.
: St Lucie County
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff f BCSS Site Map Links •Search
Florida
r`I Product Approval
fa USER: Public User
L�... sviFg�3`%
Product Approval Menu > Pmduct or Aoolicatlon Search > Application List > Application Detail 2018
APR 0� L e
FL # FL7804-R10
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived ❑
Product Manufacturer Entegra Roof Tile, LLC
Address/Phone/Email 1289 NE 9th Avenue
Okeechobee, FL 34972
(602) 515-6933
thomas.jemmett@boral.com
Authorized Signature Thomas Jemmett
thomas.jemmett@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Roofing Tiles
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida Ucense PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 11/02/2018
Validated By John W. Knezevich, PE
R Validation Checklist - Hardcopy Received
Certificate of Independence FL7804 R10 COI 2016 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard Year
ASTM C1492
2003
FRSA/TRI April 2012
2012
SSTD 11
1997
TAS 100
1995
TAS 101
1995
TAS 102
1995
TAS 102(A)
1995
TAS 112
1995
Equivalence of Product Standards
Certified By
FILE
http://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDquovOjOHI%2bA... 4/4/2018
r lunua nuuamg L;oiie Unlme
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
10/17/2017
10/19/2017
10/22/2017
12/12/2017
FL #
Model, Number or Name
Description
7804.1
Entegra Concrete Roof Tiles (HVHZ
jurisdictions)
Concrete Roof Tile
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Section 6 for Installation.
Installation Instructions
FL7804 RIO II 2017 10 FINAL ER ENTEGRA FL7804
R10 HVHZ.Ddf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL7804 R10 AE 2017 10 FINAL ER ENT RA FL7804-
R10 HVHZ.odf
Created by Independent Third Party: Yes
7804.2
Entegra Concrete Roof Tiles (non-
HVHZ jurisdictions)
Concrete Roof Tile
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use. Refer to ER
Section 6 for Installation.
Installation Instructions
FL7804 RIO II 2017 10 FINAL ER ENTEGRA FL7804
R10 NON-HVHZ.odf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL7804 R10 AE 2017 10 FINAL ER ENTE RA FL7804-
R10 NON-HVHZ.adf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601.Stair Stone Road, Tallahassee FL 32399 Phone: 85D-487-1824
The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida.law,�email addresses, are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to,this entity. Instead, contactt the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes,. effective. October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have.one. The emails provided may used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a.personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts
Credit Card
Safe
http://www.floridabuilding.org/pr/Pr apP_dtl.aspx?Param=WGEVXQwtDquovOjOHI%2bA... 4/4/2018
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
OTIRUNITYIERD 353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
Entegra Roof Tile, LLC Evaluation Report E39310.11.11-1-R4
M EGRA 1289 NE 9th Avenue FL7804-R10
R O O F T i I- E Okeechobee, FL 34972 Date of Issuance: 11/02/2011
(602) 515-6933 Revision 4:10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the 'use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DC4ANE1983
The tacsimle seal appearing was authorized by Robert Nleminen,
P.E. an 10117/2017. This does not serve as an electronlcally signed
document. Signed, sealed hardmpies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity IERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does. not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert'Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
vr-TrRRINITY'l ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Property
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
gniiw
Examination
Reference
Date
ERD (TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL (TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL (TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL (TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL(TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami -Dade (CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami -Dade (CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.06
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami -Dade (CER1592)
HVHZ Compliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI(QUA9110)
Quality Assurance
Service Confirmation
Exp.11/02/2018
Exterior Research and Design, LLC_
Evaluation Report E39330.11.11-1-R4
Certi}tcate of Authorization N9503
6' EDITION (2017) FBC HVHZ EVALUATION
FL7804-R10
Entegra Roof Tiles
Revision4:10/17/2017
Page 2 of 8
4. PRODUCT DESCRIPTION:
4.1 i..rec i`�r..rie.RS tiht_w.::fi1a\
T-
2'
10,
7
16'
Bermuda Flat
Horizon Flat
17-1/4"
`J TRINITY I E►tD
Plantation Flat
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4
Cert1ficate ojAuthorizotfon #9503 6T" EDITION (2017) FBC HVHZ EVAwAT1oN FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 3 of 8
4.2
4.3
f
�)o
`,J TRINITY IERD
TAS,112; Type la (mterh cicirlg, high profile) BEw► HigH
•
Bella High "S"
I: TAS 112, Type:lb (interlocking, low profile). ` I ESTATE. "S"and HadEiunA :.
Estate "S" Hacienda
Galena Spanish "S" Regal
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
t:erb lcate of Authorlmtion #9503 6' EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/1712017
Page 4 of 8
V I RINI"jY J ERD
5. L mrwiONs:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 13.2, Appendix W.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in the roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, buf not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using; the data outlined herein.
-. TABLE 1: AERODXNAMIC'MULTIPLIERS=il..(FT3� , -
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.289
Horizon Flat
0.305
0.330
Bella High "S"
0.349
0.378
Estate "S"
0.267
0.289
Hacienda
0.267
0.289
Galena Spanish '5"
N/A
0.235
Regal
0.287
0.311
TABLE! RESTbRING:MOMENTDUE TO_GRAVITIF - M.(Fi-LBF);,;. ; -
Roof Slope
(0)
Tile
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
S:12<0<6:12
6:12<0<7:12
0>7:12
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
1 7.26
7.95
7.09
7.76
1 6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
1 5.85
6.51
5.68
6.33
1 5.50
6.13
Estate "S"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.69
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "S"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
7.77
8.34
7.65
8.20
7.49
8.03
7.30
7.83
7.10
7.61
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
C-fff ate of Authorizodon!l9503 6T"EDITION (2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 5 of 8
F)o
�I RINIIY J ERD
TABLE 3A: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT zMF{FT LBF�
" MECHANICALLY>ATTACHEDSYSIEMS
Tile
Fastener
Direct -Deck
(min.15/32"
plywood)
Direct -Deck
(min.19/32"
plywood)
Battens
Type
#
Size
Shank
Gip
Nail
One (1)
10d
Smooth or Screw
N/A
7.3
9.8
4.9
Nail
Two (2)
30d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smooth or Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Bermuda Flat,
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Plantation Flat or
Horizon
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)'
10d'
Ring'
N/A
50.31
65.5'
48.31
Screw
One (1)
#8
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24A
1Installation with a 4-Inch tile headlap and fasteners located min. 21X-inch from head of tile.
Nail
One (1)2
10d
Smooth or Screw
N/A
8.81
11.82
4.12
Nail
Two (2)
10d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)2
10d
Smooth or Screw
Eave
19.02
19.02
22.12
Nail
One (1)2
lOd
Smooth or Screw
Field
24.32
24.32
24.22
Nail
Two (2)
10d
Smooth or Screw
Eave
1 31.9
31.9
32.2
Estate "S" or Hacienda
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Nail
Two (2)
10d
Ring
N/A
27.8
37.4
28.8
Nail'
Two (2)1
10d'
Ring'
N/A
43.01
67.5'
50.91
Screw
One (1)
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
1Installation with a 4-inch tile headlap and fasteners located min. 2Y/ inch from head of tile.
2 For one (1) fastener installations, utilize hole that is approximately4YI-inch from the interlocking edge.
Nail
One (1)
10d
Smooth or Screw
N/A
5.1
6.8
2.8
Nail
Two (2)
10d
Smooth or Screw
N/A
6.9
9.2
73
Nail
One (1)
10d
Smooth or Screw
Feld
23.1
23.1
19.0
Nail
One (1)
10d
Smooth or Screw
Eave
29.3
29.3
24.0
Bella High " Galena
Nail
Two (2)
10d
Smooth or Screw
Field
27.6
27.6
38.6
Spanish "S" or
or Regal
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Nail
Two (2)
10d
Ring
N/A
28.6
41.2
19.4
Nail'
Two (2)1
10d'
Ring'
N/A
33.1'
48.11
50.91
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
08
N/A
N/A 1
43.2
43.2
29.8
1lnstallation with a 4-inch tile headlap and fasteners located min. 2X-inch from head of tile.
Exterior Research and Design, I.I.C.
Certificate of Aatharizotlon #9503
6T" EDITION (2017) FBC HVHZ EVALUATION
Entegra Roof Tiles
Evaluation Report E39310.11.11-1-R4
FL7804-R10
Revision 4:10/17/2017
Page 6 of a
�I TRINITY I ERD
:TABLE 4.. ATTACHMENT RESISTANCE b(RRESSED AS A MOMENT- MF (Ft=LBFj .
MORTAR AND ADHESIVE SET SYSTEMS
Note fiom Entegm Roof Tile`, LLG Fhe performance dafa listed rn Fable 4 are Based on the respective adhesrvemanufocturers' test
reports and 1Vhamr Dade N0,4s'�Entegra Roaf Tile, LLC relies, gpon the ndheswe manufacturers to provrde these values for ourtrnclusron;
Jn this f8C HVHZ EvoluatJon`Report Please;consuft the rndrvrdual adhesive mbnufadurer for mfor`matlon on product opprov615;
Irmri`b'tions, ceVrsions_orotherinformotron foF.defeir►irnrng;wrnd'!o'ad and overtumrrig moment perforrrrance_ .,
Tile
Tile Adhesive
Mf (ft4bf)
Product
Product Approval
Placement
`TILE BOND'"' by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
Flat,
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Plantation
"Polyset" RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Flat or
Horizon
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
Independent (medium paddy, —30 g)
51
Independent (large paddy, -45 g)
92
"TILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
Estate "S" or
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Hacienda
®
"Polyset AH-160�� by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
50
Independent (medium paddy, —30 g)
37
Independent (large paddy, —54 g)
61
Mortar
Various
Per RAS 120
21
"TILE BONDTM" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
"Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"S", Galena
Spanish "S"
or Regal
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent (2-paddy)
30
Independent (medium paddy, "30 g)
49
Independent (large paddy, -63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
NTE RR
6�
� �7
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
CerWcateofAuthadmadon#9503 6T"EDITION (20171 FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/27/2017
Page 7 of 8
rTRINITYIERD
Hanson
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant `<
:Profiles
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, LLC. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, LLC. Evaluation Report E39310.11.11-1-R4
Certificate otAuthoriration 0503 6'" EDITION (2017) FBC HVH2 EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
- Page 8 of 8