HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED
BY
FORM R405-2017 St Lucia: Cou ky
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LANGEL RESIDENCE
Builder Name:
Street: 985 S. JENKINS ROAD
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: LANGEL
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Existing (Projecte
9. Wall Types (896.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Frame - Wood, Exterior
R=13.0 896.00 ft'
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 1
d. N/A
R= ft2
10. Ceiling Types (775.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 775.00 ft2
6. Conditioned floor area above grade (ft2) 775
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(114.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: A/C'
6 225
a. U-Factor: Dbl, U=0.34 114.33 ft2
SHGC: SHGC=0.23
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
23.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC: '
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
17.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.230
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (775.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 775.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Total Proposed Modified Loads: 27.28
Glass/Floor Area: 0.148
PASS
Total Baseline Loads: 31.02
�7�7
1 hereby certify that the plans and specifications covered by
Review of the plans and
ZHE S7,q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O2
.y Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: C4401dEaLffV
DATE: hi -
Before construction is completed
this building will be inspected for
compliance with Section 553.908
O lu
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Florida Energy Code.
COD WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
1/22/2018 8:28 AM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017 \
PROJECT
Title: LANGEL RESIDENCE
Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 775
Lot #
Owner Name: LANGEL
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
985 S. JENKINS ROAD
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: Existing (Projected)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
775 6200
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 MASTER BEDROO
156 1248 No 2
1
1 Yes
Yes
Yes
2 OFFICE
120 960 No 2
1 Yes
Yes
Yes
3 A/C
24 192 No 0
1 No
Yes
Yes
4 BATH
66 528 No 0
1 Yes
Yes
Yes
5 KITCHEN
143 1144 Yes 0
1 Yes
Yes
Yes
6 LIVING ROOM
266 2128 No 4
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 27 ft 0
156 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio
OFFICE 22 ft 0
120 ft2
-__-
0 1
0
3 Slab -On -Grade Edge Insulatio
A/C 1 ft 0
24 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
BATH 6 ft 0
66 ft2
0 1
0
5 Slab -On -Grade Edge Insulatio
KITCHEN 24 ft 0
143 ft2
____
0 1
0
6 Slab -On -Grade Edge Insulatio
LIVING ROOM 33 ft 0
266 ft2
---_
0 1
0
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
1'
ROOF
/
Roof
Gable
Roof
Solar SA Emitt
Emitt
Deck
Pitch
v
#
Type Materials
Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip Metal
817 ft2
0 ft2
Light
0.6
No 0.9
No
20
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1
Full attic Unvented
0
775 ft2
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented)
MASTER BEDRO 20
Blown
156 ft2
0.1
Wood
2
Under Attic (Unvented)
OFFICE
20
Blown
120 ft2
0.1
Wood
3
Under Attic (Unvented)
A/C
20
Blown
24 ft2
0.1
Wood
4
Under Attic (Unvented)
BATH
20
Blown
66 ft2
0.1
Wood
5
Under Attic (Unvented)
KITCHEN
20
Blown
143 ft2
0.1
Wood
6
Under Attic (Unvented)
LIVING ROOM
20
Blown
266 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width Height
Sheathing Framing
Solar
Below
OrntSpace
_ 1
N
Exterior Frame - Wood
MASTER BE
13 15
0 8
0
120.0 ft2
0
0.25
0.6
0
2
W
Exterior Frame - Wood
MASTER BE
13 12
0 8
0
96.0 ft2
0
0.25
0.6
0
3
N
Exterior Frame - Wood
OFFICE
13 10
0 8
0
80.0 ft2
0
0.25
0.6
0
_ 4
E
Exterior Frame - Wood
OFFICE
13 12
0 8
0
96.0 ft2
0
0.25
0.6
0
5
W
Exterior Frame - Wood
BATH
13 6
0 8
0
48.0 ft2
0
0.25
0.6
0
6
S
Exterior Frame - Wood
KITCHEN
13 11
0 8
0
88.0 ft2
0
0.25
0.6
0
7
W
Exterior Frame - Wood
KITCHEN
13 13
0 8
0
104.0 ft2
0
0.25
0.6
0
8
E
Exterior Frame - Wood
LIVING ROO
13 19
0 8
0
152.0 ft2
0
0.25
0.6
0
9
S
Exterior Frame - Wood
LIVING ROO
13 14
0 8
0
112.0 ft2
0
0.25
0.6
0
DOORS
#
Ornt Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S Insulated
LIVING ROO
None
.39
3
6 8 20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
v
#
Ornt ID Frame Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade Screening
1
N 1 Vinyl Low-E Double
Yes
0.34 0.23
N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
2
W 2 Vinyl Low-E Double
Yes
0.34 0.23
N
23.3 ft2
2 ft 0 in
1 ft 4 in
None
None
3
N 3 Vinyl Low-E Double
Yes
0.34 0.23
N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
4
E 4 Vinyl Low-E Double
Yes
0.34 0.23
N
11.7 ft2
2 ft 0 in
1 ft 4 in
None
None
5
S 6 Vinyl Low-E Double
Yes
0.34 0.23
N
12.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
W 7 Vinyl Low-E Double
Yes
0.34 0.23
N
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
V # Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
7 E 8 Vinyl Low-E Double Yes
8 S 9 Vinyl Low-E Double Yes
0.34 0.23 N 23.3 ft2 2 ft 0 in 1 ft 4 in None
0.34 0.23 N 11.7 ft2 2 ft 0 in 1 ft 4 in None
None
None
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000356
723.3 39.71 74.68 .2598 7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COP:1 17 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 23 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
A/C
0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/ — Supply ---
# Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 225 ft2
Attic
65 ft2 Default Leakage A/C (Default) (Default)
1 1
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
TEMPERATURES
Programable Thermostat: Y
Heating HJan H Feb
Venting Jan Feb
Mar
HX Mar
Apr
Ceiling Fans:
MayApr May
�X� Jun
Jun
Jul
riJul
Aug
rlAug
f X�
[
Sep
Sep
Oct
Nov
X� Nov
Dec
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND IN1: _CATION INSPECTION COMPONENT`�_JTERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LANGEL RESIDENCE Builder Name:
Street: 985 S. JENKINS ROAD Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: LANGEL Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceilinglattic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation -readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behon pipong and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sorinkler cover nlates and walls or ce4lonas-
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 88
The lower the EnergyPerformance Index, the more efficient the home.
985 S. JENKINS ROAD, FT. PIERCE, FL,
1. New construction or existing
Existing (Projecte
9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family
a. Frame - Wood, Exterior
R=13.0
896.00 ftz
b. N/A
R=
ft
3. Number of units, if multiple family
1
c. N/A
R=
ftz
4. Number of Bedrooms
1
d. N/A
R=
ftz
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0
775.00 ftz
6. Conditioned floor area (ftz)
775
b. N/A
R=
ftz
7. Windows— Description
Area
c. N/A
R=
z
a. U-Factor: Dbl, U=0.34
114.33 ftz
11. Ducts
a. Sup: Attic, Ret: Attic, AH: A/C
R ft z
6 225
SHGC: SHGC=0.23
b. U-Factor: N/A
ftz
SHGC:
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ftz
a. Central Unit
23.0 SEER:16.00
SHGC:
d. U-Factor: N/A
ftz
SHGC:
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
17.0
COPA.00
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.230
8. Floor Types
Insulation Area
14. Hot water systems
Cap:
50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 775.00 ftz
a. Electric
EF: 0.95
b. N/A
R= ftz
c. N/A
R= ftz
b. Conservation features
None
15. Credits
CF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
<o�
a
Pro Job:
ect Summary -�- wrightsoft® � � Date: Jan 19, 2018
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM
Project Information
For: LANGEL
985 S. JENKINS ROAD, FT. PIERCE,FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure 9433 Btuh
Ducts 2156 Btuh
Central vent (136 cfm) 4192 Btuh
Outside air
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 15781 Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Area (ft2
Heating cooling
1476 1476
Volume (ft3) 6200 6200
Air changes/hour 0.45 0.23
Equiv. AVF (cfm) 47 24
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
5.1 kW
174508 Btuh
318 cfm
0.027 cfm/Btuh
0.08 in H2O
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment Load Sizing
Structure
10252
Btuh
Ducts
1544
Btuh
Central vent (136 cfm)
2246
Btuh
Outside air
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipmerif sensible load 13339 Btuh
Latent Cooling Equipment Load Sizing
Structure
2593
Btuh
Ducts
1276
Btuh
Central vent.(136 cfm)
5691
Btuh
Outside air
Equipment latent load
9559
Btuh
Equipment total load
22899
Btuh
Req. total capacity at 0.70 SHR
1.6
ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN; JANITROL; AMANA DISTI...
Cond DSXC160241A
Coil AVPTC30C14A
AHRI ref 5924460
Efficiency
12.5 EER, 16 SEER
Sensible cooling
16100
Btuh
Latent cooling
6900
Btuh
Total cooling
23000
Btuh
Actual air flow
767
cfm
Air flow factor
0.065
cfm/Btuh
Static pressure
0.08
in H2O
Load sensible heat
ratio 0.59
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WI'1 htsoft• 2018-Jan-22 08:33:11
9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
ACCA ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S
-�- wrightsoft° Right-JO Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@4OL.COM
Job:
Date: Jan 19, 2018
By:
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Entire House
112.0 ft
8.0 ft d
775.0 ftz
MASTER BEDROOM
27.0 ft
8.0 ft heat/cool
1.0 x 156.0 ft
156.0 ft'
Ty
Construction
number
U-value
(Btuh/Wt *F)
Or
HTM
(Btuh/ft�
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
! C�.
Y--G
12GOsw _-__ —'—
_4A5 2ov __=___
12C-Osw
4A5-2ov
12C-Osw '
4A5-2ov
4A5-2ov
11 DO_____.--
12C-Osw
4A5.2ov
4A5-2ov _
16X19 Oad
22A-tpl
— 0 991
_ 0 470
0.091
0.470
0.091
0.470
0.470
0.390
0.091
0.470
_ 0.470
^i0,408
n
.._n-
a
- e_
s
s
's
—s__
w
w
w
`_
_ 2.55
- 13.16
2.55
13.16
2.18
—13,55.
2.18
— 34.74.
2.18
13.55
13.55
11.31.
2.18
34.04
34.74
_ 1.49
_ 0.00
— 200
—_ 23
248
35
200
12
12
_____ 21_
248
9
— _ 23
775
775
._. _..-177
--_.._0.._.-_._._.307_
213
—_ 3
155
12
12
—21,
216
1
2
775
1123102
. 450
543
461_
— 396
154
158
386
—_ 316
465
1216
339
158
163
238
- 120
—_--__ 12
0
0
0
0
0
108
_0
--' ' 276
_,_ 154-
0
--- 237
_ 158.
0
0
0
0
0
___ __,0
159
0
_ 811
232
0
0
0
0
0
0
0
2.55
13.16
13.16
10.92
2.55
13.16
13.16
_ 1:59
27.69
—0-
0
0
0
w
-_-_-_229
550
118
307
_ _ 1229
471
306
— 811
__- 1152
_ 0
—0
96
0
— 23
! 158
—156
w=
73
0
2
156
_27
___-0,
185
0
—_307
_� 47
— 748
_ --
_C_ _
F
0.989
-
6
c) AED excursion
o
271
Envelope loss/gain
8002
6020
1917
1867
12
a) Infiltration
b) Room ventilation
1431
0
392
0
345
0
94
0
13
Internal gains: Occupants @ 230
Appliances/other
8
1840
2000
2
460
0
Subtotal (lines 6 to 13)
9433
10252
2262
2422
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
23%
15%
0
0
0
9433
2156
0
0
0
10252
1544
23%
15%
0
0
19
2281
521
0
0
17
2439
367
F1Total
room load
Air required (cfm)
1
111589
318
11796
767
2802
77
2806
182
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft, 2018-Jan-22 08:33:11
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
��` ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S
wrightsoft° Right-J® Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@AOL.COM
Job:
Date: Jan 19, 2018
By:
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
OFFICE
22.0 ft
8_0 it heat/cool
10.0 x 12.0 it
120.0 ft2
A/C
0 ft
8.0 ft heat/cool
4.0 x 6.0 ft
24.0 ft2
Ty
Construction
number
U-value
(Btuh/ftz°F)
Or
HTM
(Btuhlft�
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (ft�
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
Vl✓
_,_��-.G_
y✓
_
�-
12C Osw - -'
_4A5:2ov_ -
12C-Osw
4A5-2ov_ _
12C-Osw '
4A5-2ov
4A5-2ov
11 DO
12C-Osw
4A5-2ov
4A5-2ov^
j6X19.:Oad_ _�_
22A-tpl _
0 091
�-0 47-0
0.091
_ - 0.470
_ 0.091
0.470
0.470
0.3.9_0.
0.091
0.470
� 0.470
0.408
0.989
n
_n_
a
a
s
s
s
`s_.
w
w
w
_. __
-
2.55
__ _13.16
2.55
13.16
2.55
13.16
13.16
10.92
2.55
13.16
13.16
1 59
27.69
2:18
r 13.55
2.18
34.74
- 2.18
13.55
13.55
� 11.31.
2.18
34.04
34.74
_ T1.49
0.00
80
12
96
_ ! 12
0
0
0
0
68
.,- 0
84
1-
174
_ 154
215
`- 154
0
0
0
0
0
0
_ _-0
190
609
149
. 158
184
405
0
__0
0
0
0
0
- , 0
_____ 0•
0
0
0
_Q
0
0
0
0
0
0
0
-. 0-
0
0
0
_ 120,
22
0
0
0
_ 0
0
0
0
-^178.
_ 0
_
0
0
0
0
6
0
0
_ 0
0
0
_ 0
_ 24
0
0
0
_ U
0
0
0
3a
0
0
0
0
0.
0
0
_ _ _0
____36.
0
W
0
0
0
_ 12Q
120
0
0
0
- 24
C
F
_ 24
0
6
c) AED excursion
-79
-2
Envelope loss/gain
1496
996
38
34
12
a) Infiltration
b) Room ventilation
281
0
77
01
0
01
0
0
13
Intemal gains: Occupants @ 230
Appliances/other
2
460
0
0
0
0
Subtotal (lines 6 to 13)
1777
1533
38
34
14
151
Less extemal load
Less transfer
Redistribution
Subtotal
Duct loads
23%
15%
0
0
11
1788
409
0
0
10
1543
232
23%
15%
0
0
-38
0
0
0
0
-34
0
0
Total room load
Air required (cfm)
2197
60
1776
115
0
0
0
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft® Right -Suite® Universal 2017 17.0:14 RSU08101 2018-Jan-22 08:33:11
Page 2
14Cr-*, ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S
wrightsoft` Right-M Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
Job:
Date: Jan 19, 2018
By:
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
BATH
6.0 ft
8.0 ft heat/cool
9.0 x 6.0 ft
54.0 ftz
KITCHEN
24.0 ft
8.0 ft heaticool
11.0 x 13.0 ft
143.0 ftz
Ty
Construction
number
U-value
(Btuh/ft;°F)
Or
HTM
(Btuh/ftz)
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
yWJJ
12C Osw --
_4A5-2ov`
12C-Osw
4A5-2ov
4A5-2ov
4A5-2ov
11DO_ -
12C-Osw
4A5-2ov
4A5-2ov
22A-tpl _
0 091
0._470
0.091
n
_n_
a
2.55
13.16
2.55
2.55
13.16
13.16
10.92
2.55
13.16
13.16
27.69
- 2.18
, 13.55,
2.18
2.18
13.55
13.55
2.18
34.04
_ 34.74
0.00
O
�__.0
0
0
0
0
--0
48
0
0
o_.o
0
0
0
0
0
-. 0
48
0
0
_0
0
0OO
0
0
_ 0
0
�' 88
0
12
0
104
9
0
_` 0
0
76
0
12
0.
V- _o
-0
0
166
0
163
' 0
_-G
V�J
T-G
--0
0
194
0
158
0
242
118
0
--0.091
0.470
0.470
0 390
0.091
0.470
0.470
s
s
s
_s__
w
w
w^
-
0
0
0
-0.
122
0
0
�166
0
0
0
0
105
0
0
w
95
1
0
207
306
0
_
F
0.989
54
6
143
_ 24
665
0
0
6
c) AED excursion
-10
-28
Envelope loss/gain
374
175
1603
1027
12
a) Infiltration
b) Room ventilation
77
0
21
0
307
0
84
0
13
Internal gains: Occupants @ 230
Appliances/other
0
0
0
0
0
2000
Subtotal (lines 6 to 13)
451
196
1910
3111
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
23%
15%
0
0
0
451
103
0
0
0
1%
30
23%
15%
0
0
0
1910
43 6
0
0
0
3111
468
Total room load
Air required (cfm)
554
15
225
15
1
1
2347
64
3579
233
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrigf7tsoft' 2018-Jan-22 08:33:11
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3
��` ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Doorfaces: S
-�+ wrightsoft^ Right-J® Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@40L.COM
Job:
Date: Jan 19, 2018
By:
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
LIVING ROOM
33.0 ft
8.0 ft heat/cool
1.0 x 278.0 ft
278.0 ft2
Ty
Construction
number
U-value
(Btuh/ft;°F)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
--
6
11
�C_
12C-0sw
_4A&2ov -_
12C-0sw
4A5-2ov �
12C-0sw
4A5-2ov
4A5.2ov
11D0
12C-0sw
4A5-2ov
4A5.2ov
_ __
16X19-0ad `� ^^�
22A-tp -
- 0.091
0.47_0
0.091
_ 0_470
0.091
0A70
0.470
_ _ 0.390
o.091
0.470
0.470
_
�__0.40t3
0.989
n
_.n__
a
a
s
s
s
_s_
w
w
w _
_
_
2.55
_ 13.16
2.55
13.16
2.55
13.16
13.16
10.92
2.55
13.16
13.116
_ _
1.59
27.69
2.18
13.55
2.18
34.74
0
Q
152
23
---- 0
__ 0
_0.
328
307
0
---0
281
811.
-
-
- �-
IM
-
G
!-D
_.__Q
129
2_
-_
_
2.18
13.55
13.55
11 31
2.18
34.04
34.74
_ 1,_4.9_
0.00
_
112
12
0
_ • -21_
0
0
a 0
278
79
12
0
_ 21.
0
0
0
33
202
154
0
__--229
0
0
0
914
173
158
0
238
0
0
_ 0
0
W
�--G
L--G
---
C�___.
F-
__--
_
J
ILI
6
c) AED excursion
-153
Envelope loss/gain
2575
1921
12
a) Infiltration
b) Room ventilation
422
0
115
0
13
Internal gains: Occupants @ 230
Appliances/other
4
920
0
Subtotal (lines 6 to 13)
2996
2956
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
23%
15%
0
0
8
3004
686
0
0
7
2963
446
Total room load
Air required (cfm)
3690
101
3409
222
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
41- wrightsaft' 2018-Jan-22 08:33:11
Right -Suite(® Universal 2017 17.0.14 RSU08101 Page 4
...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD. rup Calc = MJ8 Front Door faces: S
DuctSystem Summary Job:
-�- wrightsoft® StS
y Date: Jan 19, 2018
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM
Project Information
For: LANGEL
985 S. JENKINS ROAD, FT. PIERCE,FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.08
in H2O
0
in H2O
0.08
in H2O
0.040 / 0.040
in H2O
0.079
in/100ft
318
cfm
Cooling
0.08
in H2O
0
in H2O
0.08
in H2O
0.040 / 0.040
in H2O
0.079
in/100ft
767
cfm
101 ft
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
BATH
h 554
15
15
0.080
4.0
Ox 0
VIFx
9.7
90.0
st1
KITCHEN
c 3579
64
233
0.079
8.0
Ox0
VIFx
11.2
90.0
st1
LIVING ROOM
C 3409
101
222
0.081
8.0
Ox0
VIFx
9.2
90.0
st1
MASTER BEDROOM
C 2806
77
182
0.101
7.0
OX 0
VIFx
9.2
70.0
OFFICE
c 1776
60
115
0.107
7.0
Ox0
VIFx
5.0
70.0
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
Peak AVF
181
469
0.079
597
12.0
0 x 0
VinlFlx
Return Branch Detail Table
Grille
Htg
Cig
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FR
(fpm)
(in)
(in)
Opening (in)
Matl
Trunk
rb2
Ox 0
101
222
0
0
0
0
Ox 0
VIFx
rb1
Ox0
124
348
0
0
0
0
Ox 0
VIFx
rb3
Ox 0
921
1971
0
01
0
01
Ox 0
VIFx
wri htsoftp 2018-Jan-22 08:37:07
��9 Right -Suited Universal 2017 17.0.14 RSU08101
..ck Calcs\Documents\LANGEL HOME-JENKISN ROAD. rup Calc = MJ8 Front Door faces: S Page 1