Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODESCANNED BY FORM R405-2017 St Lucia: Cou ky FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LANGEL RESIDENCE Builder Name: Street: 985 S. JENKINS ROAD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: LANGEL Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Existing (Projecte 9. Wall Types (896.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 896.00 ft' b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types (775.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 775.00 ft2 6. Conditioned floor area above grade (ft2) 775 b. N/A R= ft2 Conditioned floor area below grade (W) 0 c. R= ft2 11. Ducts R ft2 7. Windows(114.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: A/C' 6 225 a. U-Factor: Dbl, U=0.34 114.33 ft2 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: ' 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.230 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (775.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 775.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits CF, Pstat Total Proposed Modified Loads: 27.28 Glass/Floor Area: 0.148 PASS Total Baseline Loads: 31.02 �7�7 1 hereby certify that the plans and specifications covered by Review of the plans and ZHE S7,q?� this calculation are in compliance with the Florida Energy specifications covered by this O2 .y Off, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: C4401dEaLffV DATE: hi - Before construction is completed this building will be inspected for compliance with Section 553.908 O lu I hereby certify that this building, as designed, is in compliance Florida Statutes. 5� with the Florida Energy Code. COD WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1/22/2018 8:28 AM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 \ PROJECT Title: LANGEL RESIDENCE Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 775 Lot # Owner Name: LANGEL Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 985 S. JENKINS ROAD Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: Existing (Projected) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 775 6200 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 156 1248 No 2 1 1 Yes Yes Yes 2 OFFICE 120 960 No 2 1 Yes Yes Yes 3 A/C 24 192 No 0 1 No Yes Yes 4 BATH 66 528 No 0 1 Yes Yes Yes 5 KITCHEN 143 1144 Yes 0 1 Yes Yes Yes 6 LIVING ROOM 266 2128 No 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 27 ft 0 156 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio OFFICE 22 ft 0 120 ft2 -__- 0 1 0 3 Slab -On -Grade Edge Insulatio A/C 1 ft 0 24 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio BATH 6 ft 0 66 ft2 0 1 0 5 Slab -On -Grade Edge Insulatio KITCHEN 24 ft 0 143 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio LIVING ROOM 33 ft 0 266 ft2 ---_ 0 1 0 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 1' ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 817 ft2 0 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 775 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) MASTER BEDRO 20 Blown 156 ft2 0.1 Wood 2 Under Attic (Unvented) OFFICE 20 Blown 120 ft2 0.1 Wood 3 Under Attic (Unvented) A/C 20 Blown 24 ft2 0.1 Wood 4 Under Attic (Unvented) BATH 20 Blown 66 ft2 0.1 Wood 5 Under Attic (Unvented) KITCHEN 20 Blown 143 ft2 0.1 Wood 6 Under Attic (Unvented) LIVING ROOM 20 Blown 266 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below OrntSpace _ 1 N Exterior Frame - Wood MASTER BE 13 15 0 8 0 120.0 ft2 0 0.25 0.6 0 2 W Exterior Frame - Wood MASTER BE 13 12 0 8 0 96.0 ft2 0 0.25 0.6 0 3 N Exterior Frame - Wood OFFICE 13 10 0 8 0 80.0 ft2 0 0.25 0.6 0 _ 4 E Exterior Frame - Wood OFFICE 13 12 0 8 0 96.0 ft2 0 0.25 0.6 0 5 W Exterior Frame - Wood BATH 13 6 0 8 0 48.0 ft2 0 0.25 0.6 0 6 S Exterior Frame - Wood KITCHEN 13 11 0 8 0 88.0 ft2 0 0.25 0.6 0 7 W Exterior Frame - Wood KITCHEN 13 13 0 8 0 104.0 ft2 0 0.25 0.6 0 8 E Exterior Frame - Wood LIVING ROO 13 19 0 8 0 152.0 ft2 0 0.25 0.6 0 9 S Exterior Frame - Wood LIVING ROO 13 14 0 8 0 112.0 ft2 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated LIVING ROO None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.23 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 2 W 2 Vinyl Low-E Double Yes 0.34 0.23 N 23.3 ft2 2 ft 0 in 1 ft 4 in None None 3 N 3 Vinyl Low-E Double Yes 0.34 0.23 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 4 E 4 Vinyl Low-E Double Yes 0.34 0.23 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None 5 S 6 Vinyl Low-E Double Yes 0.34 0.23 N 12.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 7 Vinyl Low-E Double Yes 0.34 0.23 N 9.0 ft2 2 ft 0 in 1 ft 4 in None None 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 WINDOWS Orientation shown is the entered, Proposed orientation. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 7 E 8 Vinyl Low-E Double Yes 8 S 9 Vinyl Low-E Double Yes 0.34 0.23 N 23.3 ft2 2 ft 0 in 1 ft 4 in None 0.34 0.23 N 11.7 ft2 2 ft 0 in 1 ft 4 in None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 723.3 39.71 74.68 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 23 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None A/C 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply --- # Location R-Value Area --- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 225 ft2 Attic 65 ft2 Default Leakage A/C (Default) (Default) 1 1 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat: Y Heating HJan H Feb Venting Jan Feb Mar HX Mar Apr Ceiling Fans: MayApr May �X� Jun Jun Jul riJul Aug rlAug f X� [ Sep Sep Oct Nov X� Nov Dec Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND IN1: _CATION INSPECTION COMPONENT`�_JTERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LANGEL RESIDENCE Builder Name: Street: 985 S. JENKINS ROAD Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: LANGEL Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceilinglattic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation -readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behon pipong and wiring- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sorinkler cover nlates and walls or ce4lonas- a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the EnergyPerformance Index, the more efficient the home. 985 S. JENKINS ROAD, FT. PIERCE, FL, 1. New construction or existing Existing (Projecte 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=13.0 896.00 ftz b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 775.00 ftz 6. Conditioned floor area (ftz) 775 b. N/A R= ftz 7. Windows— Description Area c. N/A R= z a. U-Factor: Dbl, U=0.34 114.33 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: A/C R ft z 6 225 SHGC: SHGC=0.23 b. U-Factor: N/A ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 23.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 17.0 COPA.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14. Hot water systems Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 775.00 ftz a. Electric EF: 0.95 b. N/A R= ftz c. N/A R= ftz b. Conservation features None 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/22/2018 8:28 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 <o� a Pro Job: ect Summary -�- wrightsoft® � � Date: Jan 19, 2018 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For: LANGEL 985 S. JENKINS ROAD, FT. PIERCE,FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 9433 Btuh Ducts 2156 Btuh Central vent (136 cfm) 4192 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 15781 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (ft2 Heating cooling 1476 1476 Volume (ft3) 6200 6200 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 47 24 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 174508 Btuh 318 cfm 0.027 cfm/Btuh 0.08 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 10252 Btuh Ducts 1544 Btuh Central vent (136 cfm) 2246 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmerif sensible load 13339 Btuh Latent Cooling Equipment Load Sizing Structure 2593 Btuh Ducts 1276 Btuh Central vent.(136 cfm) 5691 Btuh Outside air Equipment latent load 9559 Btuh Equipment total load 22899 Btuh Req. total capacity at 0.70 SHR 1.6 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL; AMANA DISTI... Cond DSXC160241A Coil AVPTC30C14A AHRI ref 5924460 Efficiency 12.5 EER, 16 SEER Sensible cooling 16100 Btuh Latent cooling 6900 Btuh Total cooling 23000 Btuh Actual air flow 767 cfm Air flow factor 0.065 cfm/Btuh Static pressure 0.08 in H2O Load sensible heat ratio 0.59 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI'1 htsoft• 2018-Jan-22 08:33:11 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACCA ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S -�- wrightsoft° Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@4OL.COM Job: Date: Jan 19, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 112.0 ft 8.0 ft d 775.0 ftz MASTER BEDROOM 27.0 ft 8.0 ft heat/cool 1.0 x 156.0 ft 156.0 ft' Ty Construction number U-value (Btuh/Wt *F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ! C�. Y--G 12GOsw _-__ —'— _4A5 2ov __=___ 12C-Osw 4A5-2ov 12C-Osw ' 4A5-2ov 4A5-2ov 11 DO_____.-- 12C-Osw 4A5.2ov 4A5-2ov _ 16X19 Oad 22A-tpl — 0 991 _ 0 470 0.091 0.470 0.091 0.470 0.470 0.390 0.091 0.470 _ 0.470 ^i0,408 n .._n- a - e_ s s 's —s__ w w w `_ _ 2.55 - 13.16 2.55 13.16 2.18 —13,55. 2.18 — 34.74. 2.18 13.55 13.55 11.31. 2.18 34.04 34.74 _ 1.49 _ 0.00 — 200 —_ 23 248 35 200 12 12 _____ 21_ 248 9 — _ 23 775 775 ._. _..-177 --_.._0.._.-_._._.307_ 213 —_ 3 155 12 12 —21, 216 1 2 775 1123102 . 450 543 461_ — 396 154 158 386 —_ 316 465 1216 339 158 163 238 - 120 —_--__ 12 0 0 0 0 0 108 _0 --' ' 276 _,_ 154- 0 --- 237 _ 158. 0 0 0 0 0 ___ __,0 159 0 _ 811 232 0 0 0 0 0 0 0 2.55 13.16 13.16 10.92 2.55 13.16 13.16 _ 1:59 27.69 —0- 0 0 0 w -_-_-_229 550 118 307 _ _ 1229 471 306 — 811 __- 1152 _ 0 —0 96 0 — 23 ! 158 —156 w= 73 0 2 156 _27 ___-0, 185 0 —_307 _� 47 — 748 _ -- _C_ _ F 0.989 - 6 c) AED excursion o 271 Envelope loss/gain 8002 6020 1917 1867 12 a) Infiltration b) Room ventilation 1431 0 392 0 345 0 94 0 13 Internal gains: Occupants @ 230 Appliances/other 8 1840 2000 2 460 0 Subtotal (lines 6 to 13) 9433 10252 2262 2422 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 15% 0 0 0 9433 2156 0 0 0 10252 1544 23% 15% 0 0 19 2281 521 0 0 17 2439 367 F1Total room load Air required (cfm) 1 111589 318 11796 767 2802 77 2806 182 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft, 2018-Jan-22 08:33:11 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ��` ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S wrightsoft° Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jan 19, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area OFFICE 22.0 ft 8_0 it heat/cool 10.0 x 12.0 it 120.0 ft2 A/C 0 ft 8.0 ft heat/cool 4.0 x 6.0 ft 24.0 ft2 Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuhlft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 Vl✓ _,_��-.G_ y✓ _ �- 12C Osw - -' _4A5:2ov_ - 12C-Osw 4A5-2ov_ _ 12C-Osw ' 4A5-2ov 4A5-2ov 11 DO 12C-Osw 4A5-2ov 4A5-2ov^ j6X19.:Oad_ _�_ 22A-tpl _ 0 091 �-0 47-0 0.091 _ - 0.470 _ 0.091 0.470 0.470 0.3.9_0. 0.091 0.470 � 0.470 0.408 0.989 n _n_ a a s s s `s_. w w w _. __ - 2.55 __ _13.16 2.55 13.16 2.55 13.16 13.16 10.92 2.55 13.16 13.16 1 59 27.69 2:18 r 13.55 2.18 34.74 - 2.18 13.55 13.55 � 11.31. 2.18 34.04 34.74 _ T1.49 0.00 80 12 96 _ ! 12 0 0 0 0 68 .,- 0 84 1- 174 _ 154 215 `- 154 0 0 0 0 0 0 _ _-0 190 609 149 . 158 184 405 0 __0 0 0 0 0 - , 0 _____ 0• 0 0 0 _Q 0 0 0 0 0 0 0 -. 0- 0 0 0 _ 120, 22 0 0 0 _ 0 0 0 0 -^178. _ 0 _ 0 0 0 0 6 0 0 _ 0 0 0 _ 0 _ 24 0 0 0 _ U 0 0 0 3a 0 0 0 0 0. 0 0 _ _ _0 ____36. 0 W 0 0 0 _ 12Q 120 0 0 0 - 24 C F _ 24 0 6 c) AED excursion -79 -2 Envelope loss/gain 1496 996 38 34 12 a) Infiltration b) Room ventilation 281 0 77 01 0 01 0 0 13 Intemal gains: Occupants @ 230 Appliances/other 2 460 0 0 0 0 Subtotal (lines 6 to 13) 1777 1533 38 34 14 151 Less extemal load Less transfer Redistribution Subtotal Duct loads 23% 15% 0 0 11 1788 409 0 0 10 1543 232 23% 15% 0 0 -38 0 0 0 0 -34 0 0 Total room load Air required (cfm) 2197 60 1776 115 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® Right -Suite® Universal 2017 17.0:14 RSU08101 2018-Jan-22 08:33:11 Page 2 14Cr-*, ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Door faces: S wrightsoft` Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Date: Jan 19, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BATH 6.0 ft 8.0 ft heat/cool 9.0 x 6.0 ft 54.0 ftz KITCHEN 24.0 ft 8.0 ft heaticool 11.0 x 13.0 ft 143.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ftz) Area (ft� or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yWJJ 12C Osw -- _4A5-2ov` 12C-Osw 4A5-2ov 4A5-2ov 4A5-2ov 11DO_ - 12C-Osw 4A5-2ov 4A5-2ov 22A-tpl _ 0 091 0._470 0.091 n _n_ a 2.55 13.16 2.55 2.55 13.16 13.16 10.92 2.55 13.16 13.16 27.69 - 2.18 , 13.55, 2.18 2.18 13.55 13.55 2.18 34.04 _ 34.74 0.00 O �__.0 0 0 0 0 --0 48 0 0 o_.o 0 0 0 0 0 -. 0 48 0 0 _0 0 0OO 0 0 _ 0 0 �' 88 0 12 0 104 9 0 _` 0 0 76 0 12 0. V- _o -0 0 166 0 163 ' 0 _-G V�J T-G --0 0 194 0 158 0 242 118 0 --0.091 0.470 0.470 0 390 0.091 0.470 0.470 s s s _s__ w w w^ - 0 0 0 -0. 122 0 0 �166 0 0 0 0 105 0 0 w 95 1 0 207 306 0 _ F 0.989 54 6 143 _ 24 665 0 0 6 c) AED excursion -10 -28 Envelope loss/gain 374 175 1603 1027 12 a) Infiltration b) Room ventilation 77 0 21 0 307 0 84 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 2000 Subtotal (lines 6 to 13) 451 196 1910 3111 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 15% 0 0 0 451 103 0 0 0 1% 30 23% 15% 0 0 0 1910 43 6 0 0 0 3111 468 Total room load Air required (cfm) 554 15 225 15 1 1 2347 64 3579 233 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigf7tsoft' 2018-Jan-22 08:33:11 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ��` ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD.rup Calc = MJ8 Front Doorfaces: S -�+ wrightsoft^ Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@40L.COM Job: Date: Jan 19, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LIVING ROOM 33.0 ft 8.0 ft heat/cool 1.0 x 278.0 ft 278.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool -- 6 11 �C_ 12C-0sw _4A&2ov -_ 12C-0sw 4A5-2ov � 12C-0sw 4A5-2ov 4A5.2ov 11D0 12C-0sw 4A5-2ov 4A5.2ov _ __ 16X19-0ad `� ^^� 22A-tp - - 0.091 0.47_0 0.091 _ 0_470 0.091 0A70 0.470 _ _ 0.390 o.091 0.470 0.470 _ �__0.40t3 0.989 n _.n__ a a s s s _s_ w w w _ _ _ 2.55 _ 13.16 2.55 13.16 2.55 13.16 13.16 10.92 2.55 13.16 13.116 _ _ 1.59 27.69 2.18 13.55 2.18 34.74 0 Q 152 23 ---- 0 __ 0 _0. 328 307 0 ---0 281 811. - - - �- IM - G !-D _.__Q 129 2_ -_ _ 2.18 13.55 13.55 11 31 2.18 34.04 34.74 _ 1,_4.9_ 0.00 _ 112 12 0 _ • -21_ 0 0 a 0 278 79 12 0 _ 21. 0 0 0 33 202 154 0 __--229 0 0 0 914 173 158 0 238 0 0 _ 0 0 W �--G L--G --- C�___. F- __-- _ J ILI 6 c) AED excursion -153 Envelope loss/gain 2575 1921 12 a) Infiltration b) Room ventilation 422 0 115 0 13 Internal gains: Occupants @ 230 Appliances/other 4 920 0 Subtotal (lines 6 to 13) 2996 2956 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 23% 15% 0 0 8 3004 686 0 0 7 2963 446 Total room load Air required (cfm) 3690 101 3409 222 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed 41- wrightsaft' 2018-Jan-22 08:33:11 Right -Suite(® Universal 2017 17.0.14 RSU08101 Page 4 ...ck Calcs\Documents\LANGEL HOME-JENKISN ROAD. rup Calc = MJ8 Front Door faces: S DuctSystem Summary Job: -�- wrightsoft® StS y Date: Jan 19, 2018 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,AOL.COM Project Information For: LANGEL 985 S. JENKINS ROAD, FT. PIERCE,FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0.079 in/100ft 318 cfm Cooling 0.08 in H2O 0 in H2O 0.08 in H2O 0.040 / 0.040 in H2O 0.079 in/100ft 767 cfm 101 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BATH h 554 15 15 0.080 4.0 Ox 0 VIFx 9.7 90.0 st1 KITCHEN c 3579 64 233 0.079 8.0 Ox0 VIFx 11.2 90.0 st1 LIVING ROOM C 3409 101 222 0.081 8.0 Ox0 VIFx 9.2 90.0 st1 MASTER BEDROOM C 2806 77 182 0.101 7.0 OX 0 VIFx 9.2 70.0 OFFICE c 1776 60 115 0.107 7.0 Ox0 VIFx 5.0 70.0 Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 181 469 0.079 597 12.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 101 222 0 0 0 0 Ox 0 VIFx rb1 Ox0 124 348 0 0 0 0 Ox 0 VIFx rb3 Ox 0 921 1971 0 01 0 01 Ox 0 VIFx wri htsoftp 2018-Jan-22 08:37:07 ��9 Right -Suited Universal 2017 17.0.14 RSU08101 ..ck Calcs\Documents\LANGEL HOME-JENKISN ROAD. rup Calc = MJ8 Front Door faces: S Page 1