HomeMy WebLinkAboutNOA - ESTATE - S TILESCANNED
8y
St Lucie Count f MIAMI-DADE COUNTY
MIAMIi i PRODUCT CONTROL SECTION
i - 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Entegra Roof Tile, LLC
1289 NE 9" Ave
Okeechobee, FL. 34972
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in
Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or
material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of
such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by
Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code including
the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Estate "S" Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in
the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall
be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA No. 14-1120.08 and consists of pages 1 through 6.
The submitted documentation was reviewed by Gaspar J Rodriguez.
MIAMI-DADE COUNTY
...i
yml
NOA No. 16-0112.08
Expiration Date: 08/23/21
RLro P 0 6
.r
t
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Entegra Estate "S" Concrete Roof Tile, as manufactured by Entegra Roof Tile,
LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida
Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Dimensions
Test
Product
Applicant
Specifications
Description
Entegra Estate `S' Roof
Length = 16-1/2"
TAS 112
Low profile, interlocking, extruded
Tile
Width = 13"
Type lb
concrete roof tile equipped with two nail
Class III
hole and double roll ribs. For direct deck
or battened nail -on, mortar or adhesive
set applications.
Trim Pieces
1= varies
TAS 112
Accessory trim, concrete roof pieces for
w = varies
use at hips, rakes, ridges and valley
varying thickness
terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Okeechobee, FL
NOA No. 16-0112.08
MIAMI•DADE COUNTY Expiration Date: 08/23/21
Approval Date:02/25/16
Page 2 of 6
i
2.2 EVIDENCE SUBMITTED:
Test Ageney
Test Identifier
Test Name/Report
Date
Redland Technologies
7161-03
PA 102
Dec. 1991
7161-03
PA 102(A)
Dec. 1991
7161-03
PA 108
Dec. 1991
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
P0631-01
PA 108
July 1994
Letter Dated Aug. 1,
PA 108
Aug. 1994
1994
Professional Service Industries, Inc.
224-47099
PA 112
Sept. 1994
The Center for Applied
94-060B
PA 101
March, 1994
Engineering, Inc.
94-084
PA 101
May 1994
25-7094-1
PA 102
Oct. 1994
25-7094-7
PA 102
Oct. 1994
25-7094-4
PA 102
Oct. 1994
Project No. 307025
PA 100
Oct. 1994
Test #MDC-76
25-7183-1
PA 102
Feb. 1995
25-7183-2
PA 102
Feb. 1995
25-7214-2
PA 102
March, 1995
25-7214-6
PA 102
March, 1995
Celotex Corporation Testing Services
528454-2-1
PA 101
Sep. 1998
520109-2
Dec. 1998
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
IBA Consultants, Inc.
2381-264
TAS 112
01/08/08
American Test Lab of South Florida
RT1210.03-15
TAS 112
12/17/15
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may
required, refer to applicable building code.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control Section for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
NOA No. 16-0112.08
Expiration Date: 08/23/21
Approval Date: 02/25/16
Page 3 of 6
4. INSTALLATION
4.1 Entegra Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami
Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations.
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
Length -I (ft)
Width-w (ft)
Entegra Estate 'S' Roof Tile
10.0
1.375
1.08
Table 2: Aerodynamic Multipliers - X (ft3)
Tile
Profile
X (ft)
Batten Application
X (ft3)
Direct Deck Application
Entegra Estate 'S' Roof Tile
0.267
0.289
Table 3: Restoring Moments due to'Gravity - M9 (ft-lbf)
Tile
Profile
3":12"
4":12"
5":12"
6":12"
Greater than
7":12"
Entegra Estate
'S' Roof Tile
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15/32" plywood)
Direct Deck
(min. 19/32" plywood)
Battens
Entegra
2-10d Ring Shank Nails
27.8
37.4
28.8
Estate 'S'
Roof Tile
1-10d Smooth or Screw
Shank Nail2
8.8
11.8
4.1
2-10d Smooth or Screw
Shank Nails
16.4
21.9
7.1
1 #8 Screw2
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1-10d Smooth or Screw
Shank Nail Field Cli 2
24.3
24.3
24.2
1-10d Smooth or Screw
Shank Nail Eave Cli 2
19.0
19.0
22.1
2-10d Smooth or Screw
Shank Nails Field Clip)
35.5
35.5
34.8
2-10d Smooth or Screw
Shank Nails Eave Clip)
31.9
31.9
32.2
2-10d Ring Shank Nails' 43.0 67.5 50.9
1 Installation with a 4" the headlap and fasteners are located a min. of 2%' from head of tile.
2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge.
NOA No. 16-0112.08
Expiration Date: 08/23/21
Approval Date: 02/25/16
Page 4 of 6
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Entegra Estate 'S' Roof Tile
Adhesive
26.14
3 See manufactures component approval for installation requirements.
4 Flexible Products Company TileBond Average weight per patty 11.4 grams.
3M' 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Entegra Estate 'S'
Tile
Roof
3Mr' 2-Component Foam Roof Tile Adhesive AH-160
86.615
3M2-Component Foam Roof Tile Adhesive AH-160
45.56
5 Large paddy placement
of 54 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160
6 Medium paddy
placement of 24 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Entegra Estate 'S'
Mortar Set
20.60
Roof Tile
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
No
ENTEURR v�7
ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
MIAMI-DARE COUNTY NOA No. 16-0112.08
Expiration Date: 08/23/21
Approval Date: 02/25/16
Page 5 of 6
r
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 . This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
Nail Holes
PROFILE DRAWING
ENTEGRA ESTATE "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NA
NOA No. 16-0112.08
Expiration Date: 08/23/21
Approval Date: 02/25/16
Page 6 of 6