Loading...
HomeMy WebLinkAboutNOA - ESTATE - S TILESCANNED 8y St Lucie Count f MIAMI-DADE COUNTY MIAMIi i PRODUCT CONTROL SECTION i - 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Entegra Roof Tile, LLC 1289 NE 9" Ave Okeechobee, FL. 34972 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Estate "S" Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 14-1120.08 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. MIAMI-DADE COUNTY ...i yml NOA No. 16-0112.08 Expiration Date: 08/23/21 RLro P 0 6 .r t ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Entegra Estate "S" Concrete Roof Tile, as manufactured by Entegra Roof Tile, LLC in Okeechobee, FL as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For use in the locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be prepared as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Dimensions Test Product Applicant Specifications Description Entegra Estate `S' Roof Length = 16-1/2" TAS 112 Low profile, interlocking, extruded Tile Width = 13" Type lb concrete roof tile equipped with two nail Class III hole and double roll ribs. For direct deck or battened nail -on, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for w = varies use at hips, rakes, ridges and valley varying thickness terminations. Manufactured for each tile profile. 2.1 MANUFACTURING LOCATION 1. Okeechobee, FL NOA No. 16-0112.08 MIAMI•DADE COUNTY Expiration Date: 08/23/21 Approval Date:02/25/16 Page 2 of 6 i 2.2 EVIDENCE SUBMITTED: Test Ageney Test Identifier Test Name/Report Date Redland Technologies 7161-03 PA 102 Dec. 1991 7161-03 PA 102(A) Dec. 1991 7161-03 PA 108 Dec. 1991 P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails P0631-01 PA 108 July 1994 Letter Dated Aug. 1, PA 108 Aug. 1994 1994 Professional Service Industries, Inc. 224-47099 PA 112 Sept. 1994 The Center for Applied 94-060B PA 101 March, 1994 Engineering, Inc. 94-084 PA 101 May 1994 25-7094-1 PA 102 Oct. 1994 25-7094-7 PA 102 Oct. 1994 25-7094-4 PA 102 Oct. 1994 Project No. 307025 PA 100 Oct. 1994 Test #MDC-76 25-7183-1 PA 102 Feb. 1995 25-7183-2 PA 102 Feb. 1995 25-7214-2 PA 102 March, 1995 25-7214-6 PA 102 March, 1995 Celotex Corporation Testing Services 528454-2-1 PA 101 Sep. 1998 520109-2 Dec. 1998 Walker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 IBA Consultants, Inc. 2381-264 TAS 112 01/08/08 American Test Lab of South Florida RT1210.03-15 TAS 112 12/17/15 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test in accordance with TAS 106 may required, refer to applicable building code. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. NOA No. 16-0112.08 Expiration Date: 08/23/21 Approval Date: 02/25/16 Page 3 of 6 4. INSTALLATION 4.1 Entegra Estate "S" Concrete Roof Tile and its components shall be installed in strict compliance with Miami Dade County Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (lbf) Length -I (ft) Width-w (ft) Entegra Estate 'S' Roof Tile 10.0 1.375 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile Profile X (ft) Batten Application X (ft3) Direct Deck Application Entegra Estate 'S' Roof Tile 0.267 0.289 Table 3: Restoring Moments due to'Gravity - M9 (ft-lbf) Tile Profile 3":12" 4":12" 5":12" 6":12" Greater than 7":12" Entegra Estate 'S' Roof Tile Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Nail -On Systems Tile Profile Fastener Type Direct Deck (min 15/32" plywood) Direct Deck (min. 19/32" plywood) Battens Entegra 2-10d Ring Shank Nails 27.8 37.4 28.8 Estate 'S' Roof Tile 1-10d Smooth or Screw Shank Nail2 8.8 11.8 4.1 2-10d Smooth or Screw Shank Nails 16.4 21.9 7.1 1 #8 Screw2 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank Nail Field Cli 2 24.3 24.3 24.2 1-10d Smooth or Screw Shank Nail Eave Cli 2 19.0 19.0 22.1 2-10d Smooth or Screw Shank Nails Field Clip) 35.5 35.5 34.8 2-10d Smooth or Screw Shank Nails Eave Clip) 31.9 31.9 32.2 2-10d Ring Shank Nails' 43.0 67.5 50.9 1 Installation with a 4" the headlap and fasteners are located a min. of 2%' from head of tile. 2 When using only one fastener use the hole that is approximately 4-3/4" away from interlocking edge. NOA No. 16-0112.08 Expiration Date: 08/23/21 Approval Date: 02/25/16 Page 4 of 6 Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Estate 'S' Roof Tile Adhesive 26.14 3 See manufactures component approval for installation requirements. 4 Flexible Products Company TileBond Average weight per patty 11.4 grams. 3M' 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Entegra Estate 'S' Tile Roof 3Mr' 2-Component Foam Roof Tile Adhesive AH-160 86.615 3M2-Component Foam Roof Tile Adhesive AH-160 45.56 5 Large paddy placement of 54 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160 6 Medium paddy placement of 24 grams of 3M' 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Entegra Estate 'S' Mortar Set 20.60 Roof Tile 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". No ENTEURR v�7 ESTATE "S" TILE LABEL (LOCATED ON UNDERSIDE OF TILE) MIAMI-DARE COUNTY NOA No. 16-0112.08 Expiration Date: 08/23/21 Approval Date: 02/25/16 Page 5 of 6 r 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 . This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. Nail Holes PROFILE DRAWING ENTEGRA ESTATE "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE NA NOA No. 16-0112.08 Expiration Date: 08/23/21 Approval Date: 02/25/16 Page 6 of 6