HomeMy WebLinkAboutNOARECEIVE
SCANNED / D'
By
MIAMI-DARE St L.Ude COUMY JAN. 2' 9 2018 MIAMI-DADE COUNTY
.. . PRODUCT -CONTROL SECTION
ST. Lucie County, Permitting 11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER).: Miami, Florida 33175-2474 .
BOARD AND CODE ADMINISTRATION DIVISION T (786)31:5-2590 F (786) 31.525-.99
-NOTICE OF ACCEPTANCE. (NOA) www.niiamidade.gov/economy
GAF
1:Campus Drive
Parsippany,. NJ 07054
SCOPE:.
This NOA is being issued; under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER
Product Control Section to be used in Miami Dade County and other areas :where allowed by the Authority
Having Jurisdiction (AHJ);.
This NOA shall -not be valid after the expiration date stated below. The Miami -Dade County Product
Control Section (In. Miami Dade County.) and/or the AHJ (in areas other than Miami Dade County) .
reserve the right to have this product or material .tested for quality assurance purposes. If this product or
material fails to perform in the accepted manner, the manufacturer will incur. the expense of such testing
and the AHJ may immediately revoke, modify, or suspend the .use of such.product or material within their
jurisdiction. RER reserves the right to revoke this acceptance, if it is, determined by Miami -Dade County
Product Control Section that this product or material fails to meet the requirements of the applicable
building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of 'the Florida Building Code.
DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless. otherwise noted.herem.
RENEWAL of this NOA.shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process-. Misuse of this NON as an endorsement of any
product, for sales, advertising or any other purposes. shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA..
ADVERTISEMENT: The. NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
shall
at
Ahis NOA revisef opA No. 134022.1
1 Q703/17
MIAMI-DADE COUNTY
)A shall be provided to. the, user by the manufacturer or its distributors
e job site at the request of the Building Official.
r,
and consists of pages 1 through Jff Aft
✓ed by.Jorge L. Acebo.LAW 0
NOA No.: 14-1030:01 '
Expiration - Date: 11/04/18 .
Approval Date: 05/04/17
Page 1 of 31
ROOFING SYSTEM APPROVAL
Category:
Roofing
Sub-Cate2ory:
BUR
Material:
Fibergh
Deck Type:
Woodl
Maximum Design Pressure:
-97.5 Ps
TRADE NAMES OF PRODUCTS N
Product
Dimensions
GAFGLAS® Ply 4
39.37" (1 meter)
Wide
Tri-Ply® Ply 4
39.37" (1 meter)
Wide
GAFGLAS®
39.37" (1 meter)
F1exPly'. 6
Wide
GAFGLAS®#75
39.37" (1 meter)
Base Sheet
Wide
Tri-Ply®#75 Base
39.37" (1 meter)
Sheet
Wide
GAFGLAS® #80
39.37" (1 meter)
Ultima'T" Base Sheet
Wide
GAFGLAS®
39.37" (1 meter)
Stratavent®
Wide
Perforated Venting
Base Sheet
GAFGLAS®
39.37" (1 meter)
Stratavent® Nailable
Wide
Venting Base Sheet
Ruberoid® 20
39.37" (1 meter)
Smooth
Wide
Ruberoid® Mop
39.37" (1 meter)
Smooth
wide
Ruberoid® Mop
39.37" (1 meter)
An Wicie
5evievqo
xoid®pp3 .3, (I meter)
Smooth for, wide
:i!1,QdevG0" 4A Geer)
3th 10/03/17wide
MIAMMADE COUNTY
JUFACTURED OR LABELED BY APPLICANT:
TABLE I
Test
Product
Specification
Description
ASTM D2178
Smooth surfaced asphaltic ply sheet reinforced
with fiberglass mat.
ASTM D2178
Smooth surfaced asphaltic ply sheet reinforced
with fiberglass mat.
ASTM D2178
Smooth surfaced asphaltic ply sheet reinforced
with fiberglass mat.
ASTM D4601
Smooth asphaltic base or base/ply sheet reinforced
with fiberglass mat.
ASTM D4601
Smooth asphaltic base or base/ply sheet reinforced
with fiberglass that.
ASTM D4601
Smooth asphaltic base or base/ply sheet reinforced
with fiberglass mat.
ASTM D4897
Smooth surfaced asphaltic perforated venting base
sheet reinforced with fiberglass mat.
ASTM D4897 Smooth surfaced asphaltic nailable venting base
sheet reinforced with fiberglass mat. Bottom side
surfaced with granules.
ASTM D6163
SBS polymer -modified asphalt base or
anchor sheet reinforced with a fiberglass mat.
ASTM D6164
Smooth surfaced mop applied SBS base or
anchor sheet reinforced with a polyester mat.
ASTM D6164
Smooth surfaced mop applied SBS base or anchor
sheet reinforced with a polyester mat.
ASTM D6164
Smooth surfaced mop applied SBS base or
anchor sheet: reinforced with a polyester mat.
ASTM D6163
Smooth surfaced torch applied SBS base or anchor
sheet reinforced with a fiberglass mat.
NOA No.: 14-1030:01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 2 of 31
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE I
.. ..
Test
Product
Product
Dimensions
Specification
. . .. Description
Ruberole HW .
39.37" (1 meter)
ASTM D6164
Smooth surfaced torch applied SBS base or anchor
Smooth
wide
sheet reinforced With a polyester mat.
GAFGLAS®
X37" (1 meter)
ASTM D3909
Granule surfaced asphaltic cap sheet reinforced
Mineral Surfaced
Wide
with fiberglass mat.
Cap Sheet _.
Tri=.Ply® BUR
39.:37" (1 meter)
ASTM D3909
Granule surfaced asphaltic cap sheet reinforced
Granule Cap Sheet
Wide
with fiberglass mat.
GAFGLAS°
39.37" (1 meter)
ASTM D3909
Granule surfaced asphaltic cap sheet reinforced
EhergyCapTM
Wide
with fiberglass mat. Cap.sheet is factory coated
Mineral Surfaced
with TOPCOAT® EnergyCoieTM Elastomeric
Cap Sheet
Coating.
Topcoat® Surface
5 or 55 gallons
ASTM D6083
Solvent -based thermoplastic. rubber
Seal SB
sealant designed:to protect and restore aged roof
surfaces and to increase roof reflectivity.
Topcoat®
1, 5 or 55 gallons
ASTM D6083
Water -based elastomeric coating
Membrane
Topcoat® MB Plus
5 or 55 gallons
Proprietary
Water based, low VOC primer designed to block
asphalt bleed -through.
Topcoat° FireOut'
5 or 55 gallons
Proprietary
Low VOC, water based fire barrier coating.
Fire Barrier Coating
VersaShield® Fire-
12" x 100' rolls
ASTM D226
Non -asphaltic, fiberglass reinforce_ d underlayirient
Resistant Roof
and/or fire barrier
Deck Protection
VersaShield° SoIoTM
42" roll wide, 100
ASTM D146,
Non -asphaltic, fire resistant fiberglass
Fire -Resistant Slip
ft.
D828, D4$6.9;
underlayment
Sheet
D6757
Topcoat®
1,.5 gallons or
TAS 139
Solvent -based elastomeric sealant.
FlexSealTM
1 qt. tube
Reviewed
for
-Code Compliance
1 Q/03/17
MIAMI-DADE COUNTY
NOA No.: 14-1030:01
Expiration Date: 1.1/04/18
Approval Date: 05/04/17
Page 3-of 31
APPROVED INSULATIONS:
Product Name
EnergyGuard"' Polyiso
Insulation
EnergyGuardTM Tapered
Polyiso Insulation
EnergyGuard" Ultra Polyiso
Insulation
EnergyGuard' RA Polyiso
Insulation
EnergyGuard" RA Composite
Polyiso Insulation
EnergyGuard" RH Polyiso
Insulation
EnergyGuard"' RH Tapered
Polyiso Insulation
EnergyGuard" RN Polyiso
Insulation
EnergyGuard" Perlite Roof
Insulation
EnergyGuard'" Perlite Recover
Board
Securock® Gypsum -Fiber Roof
Board
Securock® Glass -Mat Roof
Board
Structodek® High Density Fiber
Board Roof Insulation
DensDeck® Prime Roof Board
DensDeck® Roof Board
TABLE 2
Product Description
visocvanurate foam insulation
foam insulation
polyisocyanurate foam insulation
Pol, isocyanurate foam insulation
Polyisocyanurate foam insulation with high
denl�ity fiberboard or permalite
Polyisocyanurate foam insulation
Polj isocyanurate foam insulation
Pol, .isocyanurate foam insulation
Perlite insulation board
Perlite recover board
Gyp 3um board
Glass faced gypsum board
High density fiberboard
Gyp um board
n
GvI um board
Reviewed
for
Code Compliance
10/03/17
MIAMFDADE COUNTY
Manufacturer
(With Current NOA)
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
GAF
United States Gypsum Corp.
United States Gypsum Corp.
Blue Ridge Fiberboard, Inc.
Georgia-Pacific Gypsum LLC
Georgia-Pacific Gypsum LLC
NOA No.: 14-1030AI
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 4 of 31
APPROVED FASTENERS;
TABLE: 3
Fastener
Product
Product
Manufacturer:
Number
.Name .
Description
Dimensions
(With Current: NOA)..
L
Drill-Tec' #12 Fastener'
Phillips head; modified
#12-x 8'' max.
GAF
buttress thread, pinch -point,:.
length, #3
carbon steel fastener for use
Phillips head.
in steel or wood decks. With
CR-10 coating. Available.
with a pinch point or drill
point.
2.
Drill -Tee. #14 Fastener
Truss head, self. -::drilling,
#14 x 16"
GAF.
pinch point, high thread
max. length,
fastener for use in steel, wood
. #3 Phillips
or concrete decks.
head.
3.
Drill-TecT"' ASAP 3S
Drill-TecT"' #12 Fastener with
See
GAF
brill-TeCT" 3" Standard Steel
components
Plate.
4.
Drill-TecT"' 3" Steel .Plate
Round Galvalume® steel
3" Round
GAF
stress plate with reinforcing
ribs and recessed for use with
Drill-Tec`"' fasteners.
5:.
Drill-TecT"' 3" Standard Steel
Galvalume® coated steel
3" Round
GAF
Plate
stress plate for use with
approved Drill-Tec"m
fasteners.
6.
Drill-TecT" AccuTrac®Flat
A2-SS aluminized steel plate
3" square;
GAF
Plate
for use with Drill-TecT"'
:017" thick
fasteners:
7.
Drill-TecT" AccuTrae
Galvalume® steel plate with
3" square;
GAF
Recessed Plate
recess for use with Drill-
.017" thick
TecT°' fasteners.
8.
Drill-Tec 3 in. Ribbed
Round Galvalume® plated
3" Round
GAF
Galvalume Plate (Flat)
steel stress plate with
reinforcing ribs for use with
DrilfmtecT' fasteners.
Reviewed
for
Code Compliance
10103/17
MIAMI-DARE COUNTY
NOA No.: 14-1030:01.
Expiration Date: 11/04/18
Approval Date! 65/04/17
Page 5 of 31
EVIDENCE SUBMITTED:
Test Agency
Factory Mutual Research Corp.
UL LLC
PRI Construction Materials
Technologies, LLC
Reviewed
for
Code Compliance
1.0/03/17
MIAMI-DADE COUNTY
Test Identifier
Description
Date
3014547
4470
05/22/03
302-9832
4470
0.5/ 11 /07
3033135
4470
11 /24/08
3034312
4470
04/09/09
3036980
4470
08/14/09
3038278
4470
11/18/11
3040738
4470
11 / 16/ 10
30.417.60
4470
05/26/11
3042887
4470
11/14/11
3042905
4470
O 1 /10/ 12
3046081
4470
02/13/13
3047636
4470
08/08/13
ODOA8.AM
4470
07/09/99
OD 1 A8.AM
4470
07/29/94
OY9Q5.AM
4470
04/01 /98
1139A8.AM
4470
09/04/91
2138A4.AM
4470
07/02/97
3139Q LAM
4470
01 /08/98
3D4Q2.AM
4470
05/30/97
797-03221-267
4470
09/27/07
797-03825-267
4470
07/21 /08
197-10228-267
4470
01/23/15
R1306
UL 790
04/04/17
GAF-012-02-02
ASTM D4977
11 /06/01
GAF-020-02-01
ASTM D4977
02/01 /02
GAF-082-02-01
ASTM D6083
05/07/06
GAF-084-02-01
ASTM D6083
05/09/06
GAF-122-02-01
TAS 139
05/07/06
GAF-270-02-02
ASTM D226
11/15/10
GAF-276-02-01Rev
ASTM D6083
12/16/10
GAF-276-02-62
ASTM D226
11/15/10
GAF=306-02-01
ASTM E96
07/07/11
GAF-314-02-01
ASTM D2178
08/23/11
GAF-315-02-01
ASTM D2178
08/23/11
GAF-369-02-01
ASTM C1289
10/22/12
GAF-417-02-01
ASTM C1289
05/28/13
GAF-464-02-01
ASTM C1289
10/22/12
GAF-464-02-01
ASTM C1289
02/06/14
GAF-499-02-01
ASTM D6083
03/12/14
GAF-500-02-01.
ASTM D6083
03/12/14
GAF-549-02-01
TAS 114
08/08/14
GAF-549-02=02
TAS 114
08/08/14
GAF-559-02-01
TAS 117(13)
09/3.0/14
.. NOA No.: 14-1036M
Expiration Date: 11/04/19
Approval Dater 05/04/17
Page 6 of 31
EVIDENCE SUBMITTED: (CONTINUED)
Test Agency
Test Identifier
PRI Construction Materials.
GAF-559-02-04
Technologies; LLC
GAF-559-02-05
GAF-559-02-06
GAF-559-02-W
GAF-559=02-08
GAF-559=02=09
GAF-559-02711
GAF-559-02-12
GAF-559-02-13
GAF-559-02-14
GAF-559-02-15
GAF-559=02-16
GAF-559-02-18
GAF-559-024.9
IRT of S. Fl.
02=005
02=014
Trinity I ERD
C8500.SC.1 Loi
G30250:02.10-3-R2
. .G31360.03.10
G33470.01.11
034.140.04.11-2
G34140:04.11-4-R2
G34140.04.11-5-R3
G36780.07.11-R 1
G40630.01.14-1
G40630.61.14-2A
G40 63 0.01.14-2 A-1-R 1
G43610.01.14
G6,850.08.07-1
SC6870.08.14=R.1
Atlantic & Caribbean Roof
11-053
Consultants, LLC
Reviewed
for
Code Compliance
10/03/17
MIAMI-DADE COUNTY
Description
ASTM D 1876
ASTM D .1876
TAS, 114(H)
ASTM D 903
ASTM D 903
ASTM D 903
.TAS 114
TAS 114
TAS 114.
TAS 114
TAS 114.
TAS 114
TAS.114
:TAS 114
TAS 114
TAS 114
TAS 117
ASTM D3909
ASTM D61'64
ASTM D6164
ASTM 06163
ASTM D6401
ASTM 134897
4470-TAS 114
ASTM D6163
ASTM D6164
ASTM-D6164
-ASTM D3909
ASTM D3909
ASTM D3969
TAS 114
Date
10/01/14
10/15/14
1.0/02/14
10/02/14
10/02/14
10/02/14
10/14/14
10/14/14
10/15/14
10/15/14
101151..14
10/15/14
10/15/14
04/16/15
01/18/02
03/22/02
1-1 /30/07
06/03/15
03/31/10
11/16/11
04/25/11
06/04/15
06/04/15
07/18/11
01/06/14
01/67/14
04/10/14
01/22/14
08/13/07
09%04/ 14
08/12/.1.1
NOA No.: 14-1030,01
Expiration Date: 1.1/04/18 '
Approval Date: 0 04/17
Page 7 of 31
APPROVED ASSEMBLIES
Membrane Type: BUR
Deck Type 11: Wood,.
Deck Description: Min. 19/32�,'
or greater plywood or wood plank secured 6 in. o.c. at panel end and
intermediate
su: pports with 8d ring shank nails to supports spaced 24 in. o.c. at max.
System Type A(1):
All insulation
layers are adhered, to a mechanically attached anchor sheet. Membrane is
subsequently
fully adhered to insulation.
All General and System Limitations
shall a pply.
Fire Barrier:
Topcoat® FireOutT"'
Fire Barrier Coating, VersaShielde Fire -Resistant Roof Deck Protection,
(optional)
VersaShield16
Solo- Fire -Resistant Slip Sheet, DensDeck®Roof Board, Securock® Glass -
Mat Roof Board
or Securock" Gypsum Fiber Roof Board installed per manufacturer's
installation
instructions.
Anchor sheet:
GAFGLAS�II
#80 Ultima" Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base
Sheet or Ruberoid'
20 Smooth mechanically fastened as described below:
Fastening
GAFGLAS
Ply 4, GAFGLAS® Flex plyT. 6, GAFGLAS® #75 Base Sheet or any of above
Option #1:
anchor shee
s.attached to deck with approved annular ringshank nails and tin caps at a
fastener spacing
of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field.
Not .for.use
with DensDeck or Securock Fire Barrier
(Maximum
esign Pressure .-45 psf. See General Limitation #7)
Fastening
GAFGLASI
Ply 4, GAFGLAS® FlexPly'"' 6, GAFGLAS® #75 Base Sheet or any of above
Option #2:
anchor sheets attached to deck with Drill=TecT" #12 Fastener, Drill-TecT" #14 Fastener and
Drill-TecT' 3" Steel Plate, Drill-Tec'�" AccuTrac® Flat Plate or Drill-TecT" AccuTrac®
Recessed Pate 1.2" o.c. in 3 rows: One row is in the 2" side lap. The other rows are equally
spaced approximately 12" o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #7)
Fastening
GAFGLAS® F1exPlyT" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of
Option #3:
above anchor sheets attached to deck with approved annular ring shank nails and tin caps at
a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field.
Not for use-With.D.ensDeck or Securock Fire Barrier
(Maximum
Design Pressure —52.5 psf. See General Limitation #7)
Fastening
Any of the
above anchor sheets attached to deck with approved 1'/4" annular ring shank nails
Option #4:
and inverted
3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows
staggered with
a fastener spacing of 9" o.c. in the center of the membrane.
Not for use�with
DensDeck or Securock Fire Barrier
(Maximum
Design Pressure —60 psf. See General Limitation #7)
Fastening
GAFGLAS
. #7.5 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT"
OptiTN'11-TecT"
#14 Fastener and Drill-TecT"' 3" Steel- Plate; Drill-Tec' AccuTrace
late o
- Revie
Dril
-TecT' AccuTrac® Recessed Plate 12" o.c. in.4 rows. One row is in the 2"
side ap. T
e of
er rows are equally spaced approximately 9" o.c. in the field of the sheet.
for (Maximum
Desi
on Pressure —60 psf. See General Limitation #7)
Code
Com.p1jance
1.0/03/ 17
NOA No.: 14-1030M
MIAMIOADEcoUNTY
Expiration Date: 11/04/18
Approval Datec 65/64/17
Page 8 of 31
Fastening (Continued) Any -of above anchor. -sheets attached to deck approved annular ring shank nails and 3"
Option #6: inverted Drill-TecT" insulation plates at a fastener spacing of 9" o.c. at the 4": lap, staggered in
two rows 9" in the field. Not for use with DensDeck or.Securock Fire Barrier.
(Maximum Design Pressure —60 psf. See: General Limitation. #7)
Fastening GAFG1LAS®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT"
Option #7: #12 Fastener or Drill-TecT" #14 Fastener and 3" Drill-TecT" 3" Steel Plate, grill-TecT°'
AccuTrac® Flat Plate or Drill-TecT°' AccuTrac®:Recessed Plate. 8" o.c. in 4 rows. One row is
in the 2" side lap.. The other rows are equally spaced approximately 9" o.c. in the field of
the sheet.
(Maximum Design Pressure=-75psf. See General Limitation #7)
One or more layers of any of the following insulations.
Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft?
EnergyGuardT" Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuard RH Polyiso
Insulation, EnergyGuardT" RA Polyiso Insulation, EnergyGuardT" RA Composite Polyiso Insulation
Minimum 1".thick N/A N/A
EnergyGuardT" Perlite Recover Board, DensDeck® Prime_ Roof Board
Minimum %Z" thick N/A.
EnergyGuardT" Perlite Roof Insulation
Minimum %1' thick
N/A -
N/A
N/A
Note: All insulation shall be adhered to the anchor sheet: i_n full mopping of approved hot asphalt within the
EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation panelsmay be used as a top layer placed with the
polyisocyanurate: side facing down. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting
Base Sheet laid dry or a layer of EnergyGuardT" Perlite Roof Insulation or wood fiber overlay board on all
polyisocyanurate applications.
Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Basel Sheet,
GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid® Mop Smooth; Ruberoid® Mop Smooth
1.5, Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth, Ruberoid® HW Smooth or
Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any
approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq.
applied in accordance with manufacturer's instructions. (see General Limitation #4).
.OR
GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry (not for use with
perlite. top layer insulation or composite polyiso top layer insulation).
Ply Sheet: One.or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPlyTn' 6 or
GAFGLAS®#80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied
withinthe-EVT- range and at a rate of 2074.0 lbs./sq. installed per manufacturer's installation
Revi.e
t ctions.
Cap heet: (Optional) One ly of GAFGLAS Mineral Surfaced Cap Sheet, Tri-Plye BUR Granule
r 11
Ca . Sheet or G FGLAS®EnergyCa .. Mineral Surfaced Cap -Sheet adhered in a full
Code Com ianc eppr ved asphalt applied within the-EVT range and at a rate of 20-40 lbs./sq.
10/03Mtf led per mar ufacturer's installation instructions.
NOA No.: 14-1036.01
MIAMMADE COUNTY Expiration Date: 1.1/0449
Approval Date: 05/04/17
Page 9-of 31
Surfacing: Optional
coatings i
1. Gravel or
approved
2. Topcoat®
OR
Topcoat°
Topcoat®
3. Fiber Alu
Maximum Design
Pressure: See F
Reviewed
for
Code Comphan
1.0/03/17
MIAMI-DADE COUNTY
granular surfaced membranes; required for smooth membranes. Chosen
must be applied according to manufacturer's application instructions. All
It be listed within a current NOA.
g applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
halt at 60 lbs./sq.
:mbrane..or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
ibrane applied at 0.5 to 0.75 gal./sq.
m Roo fCoating.
g Options.
NOA No.: 14-1030:01
Expiration Date: 11/04/19
Approval Date: 05/04/17
Page 10 of 31
Membrane Type:
Deck Type 1I: .
Deck .Description:
System Type A(2):
BURsp
Wood, Insulated
Min: 15/32" thick or. greater plywood or wood plank secured 6 in. o.c. at panel end and
.intermediate supports -with 8d ring shank. nails to supports spaced 24 in. o.c. At max.
All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is
subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: Topcoat® FireOuf" Fire Barrier Coating,. VersaShieldo Fire -Resistant Slip Sheet or
(optional) VersaShieldm Solo"' Fire -Resistant Slip- Sheet installed per manufacturer's installation
instructions.
Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®.#75 Base Sheet; Ruberoidm.20 Smooth or
GAFGLAS® Stratayento Venting Nailable Base Sheet is securedus described below.
Fastening Miami -Dade County Approved mina 12 ga. Annular ring shank nails and. min. 1-5/8 in.
Option #1: diameter tin caps are spaced 8 in. o.c-. in the min: 4 in. wide anchor sheet side laps and 8.
in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure: —45 psf See General Limitation #7)
Fastening Miami=Dade County Approved min. 12 ga,. Annular ring shank nails and min. 1-5/8 in.
Option.#2: diameter tin caps.are spaced 6 in. o.c. in, the:min 4 in. wide Anchor sheet side laps Arid 6
in: o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure: —'52.5 psf. See General limitation #7)
Fastening Drill-TecTM #14 Fasteners and Drill-Te¢T" 3 in. Standard Steel Plates, Drill-TecTM
Option #3: AccuTraco Flat Plates or Drill -Tee'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16
in. o.c. in the min. 4 in. wide Anchor sheet side laps and 16 in. o.c. in the field of the sheet
in two staggered rows. ...
(Maximum Design Pressure: —52.5 psf. See General Limitation #7)
Fastening Drill-TecTM #14 Fasteners and Drill=TecTM 3 in. Standard Steel Plates, Dri1l-Tec`
Option #4:. AccuTrac® Flat Plates or Drill-TecTM 3. in. Ribbed Galvalume Plate (Flat) are spaced 12
in. o.c. in the min 4 in. wide anchor sheet: side laps and 12 in. o.c: in the field ofthe sheet
in two staggered rows.
(Maximum Design Pressure: =60 psf. See General Limitation #7)
Fastening. Drill-TecTM #14 Fasteners and Drill -Too. 3 in. Standard Steel Plates, Drill-TecTM
Option #5: AccuTrace Flat Plates or Drill=TecTM 3 in.' Ribbed Galvalume Plate (Flat) are spaced 8 in.
o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in
three staggered rows.
(Maximum Design Pressure: —75 psf .See General Limitation .#7)
One or more layers of any of the following insulations.
Base nsulati Layer Insulation Fasteners Fastener
Reviewed (Table 3) Density/ft'
Ener ;yGuard" P61 fell nsulation, Ener Guard"" Tapered Polyiso Insulation, EnergyGuard`" Ultra Polyiso
Insu ,E�er uardT"H PoI iso I sulation, EnergyGuardT" RH Tapered Polyiso Insulation
Min] n1mi k�Ol�pllanC;e N/A N/A
10/03/17
NOA No.: 14-1030M
MIAMFDADEcouNTY Expiration Date: 1.1/04/18
Approval Date: 65/64/17
Page 11 of 31
Top Insulation Layer
EnergyGuard" Perlite, Roof
Minimum'/a" thick
Structodek® High Density
Minimum %2" thick -
Securock® Gypsum -Fiber Roof
Minimum '/a" thick
Roof Insulation
Insulation Fasteners
(Table 3)
N/A
N/A
DensDeck® Prime Roof Board
N/A
Fastener
Density/ft2
N/A
N/A
N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a
rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet (Optional): GAFGL S® #75 Base Sheet, Tri-:Ply® #75 Base Sheet, Ruberoid® 20 Smooth adhered in
a full mopping of hot asphalt applied at.20-401bs./sq. installed per manufacturer's
installation instructions.
Ply Sheet: When optional base sheet and/or cap sheet is present:
Two or more piies.of GAF. GLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered
in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's
installation instructions.
When optional base sheet and/or cap sheet is not present:
Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6
adhered* a full mopping of hot asphalt applied at 20-401bs./sq. installed per
manufac rer's installation instructions.
Cap Sheet (Optional): GAFGL JASo Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLASo EnergyCap'" Mineral Surfaced Cap .Sheet adhered in a full mopping of hot
asphalt aplied at 20 — 40 lbs./sq: installed per manufacturer's installation instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approve asphalt at 60 lbs./sq.
2. Topcoat Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat`' MB Plus applied at 0:5 to 0.75 gal./sq.(to be used as a primer) followed by
Topcoatq Membrane applied at 0.5 to 0,75 gal./sq.
3. Aluminu'F Fiber Roof Coating.
Maximum Design
Pres ure: fastening ptions above.
Reviewed
for
Code Compliance
10/03/17
NOA No.: 14-10301
tyni4MraaDecoutvTY Expiration Date: 11/04/18
• • Approval Date: 05/04/17
Page 12 of 31
Membrane Type: BUR
Deck Type 1I: Wood, Insulated
Deck: Description: Min: 15/32" thick:or greater plywood or wood plank secured 6 in. o.c. at panel end and
intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c._at max.
System Type A(3): All insulation layers are adhered, -to a mechanically attached anchor sheet. Membrane is
subsequently fully adhered to insulation.
All General and; System Limitations shall apply.
Fire Barrier:
Topcoat® FireOutT" Fire Barrier Coating, VersaShield° Fire -.Resistant Slip Sheet or
(optional)
VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation
instructions.
Anchor sheet:
GAFGLAS® #75 Base Sheet, Tri-Plym #75 Base Sheet, Ruberoid® 20 Smooth or
GAFGLAS® Stratayent® Venting Nailable Base Sheet is seciired.as described below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min..1-5/8 in.
Option #1:
diameter tin caps are spaced 8 in. o.c. in the min: 4 im wide anchor sheet side laps and 8
in. o.c. in the field of the'sheet in two staggered rows.
(Maximum Design Pressure: —45 psf. 'See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. an ring shank nails and min. 1-5/8 in.
Option.#2:
diameter tin caps are.spaced 6 in. o.c. in the:min 4 in. wide:anchor sheet side laps. and:6
in. o.c. in the field of the sheet in two staggered rows._
(Maximum Design Pressure: -52.5 psf. See General. Limitation #7)
Fastening
Drill-TecT°' #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-Tec'
Option #3:
AccuTrac° Flat Plates or Drill-TecT°' 3 in. Ribbed Galvalun e Plate (Flat) are spaced 16
in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the .
sheet in two staggered rows.
(Maximum Design Pressure: —52.5 psf. See General Limitation #7)
Fastening
Drill-TecT" #14 Fasteners and Drill=TecT" 3 in. Standard Steel Plates, Dri1l-TecT"'
Option #4:
AccuTrac® Flat Plates .or Drill-TecT°' 3 in. Ribbed Galvalume Plate (Flat) are'spaced 12
in. o.c. in the mini 4 in. wide anchor sheet side laps and 12 in. o.c: in the field of the
sheet in two staggered rows.
(Maximum Design Pressure: —60 psf. See General Limitation #7)
Fastening
Drill-TecT" #14 Fasteners and Drill-Tec'm.3 in. Standard Steel Plates; Drill-TecT"'
Option #5:
AccuTrac® Flat Plates or Dri11=TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in.
o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in
three staggered rows.
(Maximum Design Pressure: —75 psf See .General Limitation #7)
Reviewed
for
-Code Compliance
10/03/17
MIAMI-DADE COUNTY
NOA No.: 14-1030:01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 13 of 31
One or more layers of any of the folloN*ing insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3)- Density/ftz
EnergyGuard'" Polyiso Insulation, nergyGuardT" Tapered Polyiso: Insulation, EnergyGuard"' Ultra Polyiso
Insulation, EnergyGuard'" RH Polyiso Insulation, EnergyGuard"' RH Tapered Polyiso Insulation
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table.3) - Density/W
EnergyGuard"" Perlite Roof Insulation
Minimum 3/a" thick N/A N/A
Structodek® High Density Fiberboa d Roof Insulation
Minimum %2" thick N/A. N/A
SecurocV Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board
Minimum %11 thick N/A N/A
Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a
rate of 20-40 lbs./100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: Ruberoido 20 Smooth adhered in a full mopping of hot -asphalt applied at 20-40 lbs./sq.
Cap Sheet: GAFGL A S® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAS® EnergyCap'" Mineral Surfaced. Cap Sheet adhered in a full mopping of hot
asphalt applied at 20 — 401bs./sq. installed per manufacturer's installation instructions.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's application
instruct'ions. All coatings must be listed within a current NOA.
1. Gravel instruct
sla applied at 4001bs./s . and 3001bs./s . res ectivel in a flood coat of
�' g pp q q respectively
approved asphalt at 60 lbs./sq.
2. Topcoat Membrane or Topcoat' Surface Seal S.B applied at 1 to 1.5 gal./sq.
OR
Topcoat. MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
Topcoa& Membrane applied at 0.5 to 0.75 gal./sq.
3. Aluminum Fiber Roof Coating.
Maximum Design
Pressure: See fastening options above.
Reviewed
for
Code Complian
1.0/03/17
NOA No.: 14-1030,01
MIAMMADECOUNTY Expiration Date: 11/04/1$
Approval Date: 05/04/17
Page 14 of 31
Membrane Type:
Deck Type 1I:::
Deck Description:
System Type A(4)'
BUR
Wood, Insulated
Min: 15/32" thick: or greater plywood or wood plank secured 6 in..o.c. at panel end and
intermediate supports with 8d ring shank nails to, supports, spaced 24 in. o.c. at max.
All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is
subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier: TOPCOAT FireOufm Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or
(optional) VersaShield® Sold" Fire -Resistant Slip Sheet installed per manufacturer's installation
instructions.
Anchor sheet: GAFGLAS' #75 Base Sheet, Tri-Plym.#75 Base Sheet; Ruberoide.20 Smooth or. .
GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured:as described below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min..1-5/8 in.
Option #1:
diameter tin caps_are spaced 8 in. o.c. i.n the min: 4 in. wide anchor sheet side laps and 8
in. o.c. in the field of the sheet in two staggered rows.
(Maximum: Design Pressure: —45 psf. SeeGeneral Limitation #7)
Fastening
Miami=Dade County Approved min. 12 a annular ring. shank nails and min. .1-5/8 in.
ty pp g .
Option ##2:
diameter tin caps are spaced 6 in. o.c. in' the:min 4 in. wide anchor sheet side laps: and 6
in. o.c. in the -field of the sheet in two staggered rows.
(Maximum Design Pressure: -52.5 psf. See General Limitation #7)
Fastening -
Drill -Tee" #14 Fasteners and Drill-Tec"' 3 in. Standard Steel ,Plates, Drill-TecT"'
Option #3:
AccuTrac® Flat Plates or Dri11-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16
in. o.c. in the min. 4 in. wide anchor sheet side laps: and 16 in. o.c. in the -field of the sheet
in two staggered rows..
(Maximum Design Pressure: —52.5 psf. See General Limitation #7)
Fastening
Drill-TecT" #14 Fasteners and Drill -Tee" 3 in. Standard Steel Plates, Drill=TecT"
Option #4:
AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12
im o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet
in two staggered rows.
(Maximum Design Pressure. —60 psf. See General Limitation #7)
Fastening
Drill-TecT" #14 Fasteners and Drill -Tee'" 3 in. Standard Steel Plates, Drill-TecT"'
Option #5:
AccuTrac' Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in.
o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field.of the sheet in
three staggered rows.
(Maximum Design Pressure: —82.5 psf. See General Limitation #7)
Reviewed
for
Code Compliance
90/03/17
MIAMMADE COUNTY
NOA No.: 14-1030:01
.. Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 15 of 31
One or more layers of any of the
Insulation Layer
Energy Guard T" Polyiso Insulation,
Insulation, Ehergy.Guar&T RH Pol
Minimum 1" thick
insulations.
Insulation Fasteners Fastener Density/ft'
(Table.3)
rgyGuardT"'Tapered Polyiso Insulation, EnergyGuardT" Ultra Polyiso
Insulation, EnergyGuard"m RH'Tapered Polyiso Insulation
- N/A N/A
Note:.: All insulation shall be adhered in a full mopping of approved hot asphalt within.the EVT range and at a
to Roofing Application Standard RAS 117 for insulation: attachment.
rate of 20=401bs./100 W. Please refer
Base Sheet: GAFGLAS®
Stratavent® Perforated Venting Base Sheet is laid.dry over the insulation.
Ply Sheet: ' When optional
cap sheet is present:
Two or more
plies of GAFGLAS° Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered
in a full 'iiiopping
of hot. asphalt applied at 20-40 lbs./sq. installed per :manufacturer's
installation
instructions.
When op
ional cap sheet is not present:
Three or
inore plies of GAFGLAS® Ply 4, Tri=Ply° Ply 4; GAF.GLAS® Flex Ply 6
adhered in
a full mopping of hot asphalt applied_ at 20-40 lbs./sq. installed per
manufdcluter7s
installation instructions.
Cap Sheet (OptIional): GAFGL
Sm Mineral Surfaced Cap Sheet,. Tri-Ply® BUR Granule Cap Sheet or
GAFGLASo
Energy.Cap'" Mineral Surfaced Cap Sheet adhered in a full mopping of hot
asphalt applied
at 20 — 40 lbs./sq: installed per manufacturer's installation. instructions.
Surfacing: Optiona
on granular surfaced membranes; required for smooth membranes.
Chosen components
must be applied according to manufacturer's application
instructions.
All coatings must be listed within.a current NOA.
1. Gravel o
slag applied at400 lbs./sq. and 300 lbs./sq. respectively mi a flood coat of
approve
asphalt at 60 lbs./sq.
2. Topcoat
Membrane or Topcoat" Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat.MB
Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
Topcoat
Membrane applied at 0.5 to 0.75 gal./sq:
3. Aluminum
Fiber Roof Coating.
Maximum Design
Pressure: See faste
ing options above.
Reviewed
for
Code Comp[ian
10103/17
MIAMI-DADE COUNTY
NOA No.: 14-1030.01
Expiration Date: 11/04/18
Approval Date: OS/04/17
Page 16 of 31
Membrane Type:
BUR
Deck Type 11:
Wood, Insulated
Deck Description:
19/32" thick or greater or greater plywood or wood plank secured 6 in: o:c: at panel end...
and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c: at max.
System Type A(5):
All insulationlayers are adhered, to a mechanically attached anchor sheet.: Membrane is
subsequently fully adhered to insulation.
All General and System Limitations shall apply.
Fire Barrier:
FireOuc Fire Barrier Coating, VersaShield® Fire:Resistant Slip Sheet or VersaShield®
(optional)
Solo'" Fire -Resistant Slip Sheet.
Anchor sheet:
GAFGLASO #75 Base Sheet or Tri-Ply'#15 Base Sheet is secured as described below
with Dade County Approved min. 12 ga. galvanized ring shank nails and 32 ga., 1-5/8 in.
diameter tin tabs.
Fastening:
Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap and 8 in. o.c. in:two
staggered rows in the field of the sheet.
One or more layers of any of the following insulations.
Base Insulation Layer Insulation Fasteners -Fastener
(Table 3) . ..Density/ftz
EnergyGuardT" Polyiso Insulation, EnergyGuardT" Tapered Polyiso_ Insulation, EnergyGuardT" RH Polyiso:
Insulation, EnergyGuard TM RH Tapered Polyiso Insulation
Minimum 1" thick N/A 'N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
StructodeV High Density Fiberboard Roof Insulation, Securock® Gypsum -Fiber Roof Board
Minimum %Z" thick N/A N/A .
Note: All insulation shall be adhered in a full mopping: of approved hot asphalt within the EVT range and at a
rate of 20-40 lbs./1.00 ft2. Please refer to Roofing Application Standard RAS,117 for insulation; attachment.
Base Ply: Two or more plies of GAFGLAS® F1exPly'" 6 adhered with hot asphalt applied at 20-25
lbs./sq.
Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet adhered with hot asphalt applied: at.20-25
lbs./sq.
Surfacing: Optional on granular surfaced membranes; required for smooth membranes.
Chosen components must be applied according to manufacturer's. application
instructions. All coatings must be listed within a current NOA.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
pcoat® Me brane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq.
Reviews
for Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) -followed by
(`��p Comn��Cll I C a brane applied at 0.5 to 0:75 gal:/sq.
Max Vin't'DZ3i'gn N..d..
Pres ure: 1.0/03/t?2.5 psf:.(Se General Limitation #7)
NOA No.: 14-1030,01
MIAMMARECOUNTY Expiration Date: 1.1/04/18
• • Approval Date: 05/04/17
fags -17 of 31
Membrane Type:
Deck Type 1I:
Deck Description:
BUR
Wood,
19/32" or grea er plywood or wood plank secured 6. in. o.c. at panel end -and intermediate
supports with ,d ring shank nails to supports spaced 24 in. o.c. at max.
System Type B: Base layer of insulation is mechanically attached to roof deck. Any subsequent layers are then
adhered to base layer of insulation. Membrane is subsequently fully adhered to insulation.
All General and System Limitations shall apply.
One or more layers of any of the folloyving insulations.
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuardT" Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuardT" RA Polyiso
Insulation
Minimum 1.3" thick 1, 2, 3, 4, 5, 6, 7; 8 1:3 ft2
EnergyGuardT" RN Polyiso Insulation, EnergyGuardT" RH Polyiso Insulation
Minimum 1.4" .thick 1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz
EnergyGuardT" RA Composite Polyiso Insulation
Minimum 1.5 thick 1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz
EnergyGuardT" Perlite Roof Insulation
Minimum'%4" thick 1, 2, 3, 5, 6, 7,-8 1:2 :ft2
StructodeV High Density Fiberboard
Minimum 1" thick 1, 2, 3, 5, 6, 7,8 1:4 ft2
Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed
are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening
details). GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a
layer of EnergyGuardT" Perlite Rool nsulation or wood fiber overlay board on all polyisocyanurate
applications.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Any of the insulations options listed for Base Layer above. N/A N/A
DensDecV Prime Roof Board, Str Ictodek® High Density Fiberboard, EnergyGuardT" Perlite Recover Board
Minimum '/Z" thick N/A N/A
Note: Optional top layer of insulation shall be adhered with approved: asphalt within the EVT range and at a
rate of 20-40 lbs./100 ftZ installed per manufacturer's installation instructions. Please refer to Roofing
Application Standard RAS 117 for Insulation attachment., Composite insulation boards used as a top layer shall
be installed with the polyisocyanut iate face down.
Reviewed
for
Code Compliance
1-0/03/ 17
NOA No.: 14-1030;01
HIAMMADE COUNTY Expiration Date: 11/04/18
• • gug Ij Approval Date: 05/04/17
Page 18 of 31
Base Sheet: (Optional) Install one ply -of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet,
GAFGLAS® #80: Ultima" Base Sheet, GAFGLAS® Ply. 4, Tri=Ply® Ply 4, GAFGLAS® FlexPly "
6, Ruberoid® Mop. Smooth, Ruberoid® Mop Smooth 1.5., Ruberoid® Mop Plus Smooth or
Ruberoid® 20 Smooth directly over the top layer of insulation. Adhere .with any approved:: :.
... . ....
mopping asphalt applied within the EVT range and at a rate of 2040 lbs:/sq. installed per
inanufacturer.':s installation instructions (See General Limitation #4).
OR
GAFGLAS® Stratavent':Perforated Venting Base. Sheet loose -laid dry (not for use with perlite
wood fiber or composite polyiso top layer insulation).
Ply Sheet: Two or more plies of GAFGLAS® Ply 4, Tri-.Ply® Ply 4, GAFGLASO FlexPlyT" 6 or
GAFGLAS® #80. Ultima Base Sheet adhered in a full mopping of approved asphalt applied
within the EVT:range and at a rate of 2040 lbs./sq. installed per manufacturer's installation
instructions:
Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet,-Tri-Ply® BUR Granule -Cap
Sheet or GAFGLAS® EnergyCapT°' Mineral Surfaced Cap Sheet adhered in a full mopping of
approved. asphalt applied within, the EVT range and at a rate of 207-40 lbs./sq. installed per . -
manufacturer's installation instructions.
Surfacing: Optional on granular surfaced membranes; required_ for smooth membranes: Chosen
components must be applied according to manufacturer's application: instructions. All
coatings must be listed 'within a current NOA. .
1. Gravel or slag: applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved .
asphalt at 6.01bs./sq.
2. Topcoat® Membrane or Topcoat° Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer). followed by Topcoat®
Membrane applied at 0.5. to 0.75 gal./sq.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: -45 psf. (See General Limitation #7)
Reviewed
for
Code Compliance
10l03/17
MIAMf DADE COUNTY
NOA No.: 14-1030AI
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 19 of 31
Membrane Type: BUR
Deck Type 1I: Wood,
Deck Description: 19/32" or
supports N
System Type C(1): All layers.
fully adhe
All General and System Limitation
One or more layers of any of the folic
Base Insulation Layer
EnergyGuardT" RN Polyiso Insula
Insulation, EnergyGuardT" RA Po:
Minimum 1.3" thick
EnergyGuard" Polyiso Insulation
Minimum 1.4" thick
EnergyGuardT RA Composite Po.
Minimum 1.5" thick
EnergyGuardT" Perlite Recover Bi
Minimum'/4" thick
Structodek® High Density Fiber B
Minimum 1" thick
Note: All layers shall be simultanf
panels listed are minimum sizes al
increased maintaining the same fa
insulation attachment. GAF requi
laid dry or a layer of EnergyGuar
polyisocyanurate applications.
Top Insulation Layer
EnergyGuardT" Polyiso Insulation,
Insulation
Minimum 1.3" thick
EnergyGuardT" RN Polyiso Insulal
Minimum 1.4" thick
'um 1: ktkiewed
yGuard'" Peril 6Foof It
ium 3/" thick II II
um 1"
MIAMI-DADE COUNTY
reater plywood or wood plank secured 6 in. o.c. at panel end and intermediate
th 8d ring shank nails to supports spaced 24 in. o.c. at max.
f insulation are mechanically attached to roof deck. Membrane is subsequently
:d to insulation.
shall apply.
ring insulations.
Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuardT Polyiso Insulation, EnergyGuardT" Ultra Polyiso
Insulation, EnergyGuardT" RH Polyiso Insulation
N/A N/A
Insulation
N/A N/A
N/A N/A
N/A N/A
N/A N/A
sly fastened; see top layer below for fasteners and density. Insulation
dimensions; if larger panels are used, the number of fasteners shall be
zer density. Please refer to Roofing Application Standard RAS 117 for
either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet
Perlite Roof Insulation or wood fiber overlay board on all
Insulation Fasteners Fastener
(Table 3) Density/ft2
ergyGuardT" Ultra Polyiso Insulation, EnergyGuard" RA Polyiso
1, 2, 3, 4, 5, 6, 7,8 1:3 ft'
EnergyGuardT" RH Polyiso Insulation
1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz
Insulation
1 1, 2, 3, 5, 6, 7,8 1:3 ftz
1, 2, 3, 4, 5, 6, 7, 8 1:2 ft2
112, 3, 5, 6, 7, 8 1:4 ftz
NOA No.: 14-1030;01
Expiration Date: 11/04/18
Approval Date: 05/04/17
Page 20 of 31
Base Sheet:
..........
(Optional) Install one ply ofGAFGLAS® #75 Base Sheet, Tri-Ply° #75 Base Sheet,
GAFGLASo #80 UltimaT" Base Sheet; GAFGLASO Ply 4; Tri-Ply° Ply 4, GAFGLAS®
FlexPly"" 6. Ruberoid® Mop Smooth; Ruberoid° Mop Smooth 1.5, Ruberoida Mop_ Plus
Smooth:or Ruberoid® 20 Smooth directly over. the top layer of insulation. Adhere with any..
approved mopping asphalt applied within. the EVT range and at a rate of 20740 lbs./sq.
installed per:manufacturer's installation instructions.
OR
GAFGLAS® Stratavento :Perforated Venting Base Sheet is loose laid dry (not for use with
) ..
-wood fiber,perlite or com osite Poi isoto layer insulation
Ply Sheet:.
..When optional base sheet and/or cap sheet is present:
Two or fore plies of GAFGLAS® Ply 4, Tri Ply® Ply 4, GAFGLAS® Flex Ply 6, GAFGLAS®
#80 UltimaT" Base Sheet adhered in. a full mopping of hot asphalt applied at:20-40 lbs./sq.
installed per. manufacturer's installation instructions.
When optional base sheet. and/or cap sheet is not present:
Three or more plies. of GAFGLASO. Ply 4; Tri-Ply® Ply: 4,. GAFGLAS° Flex: Ply 6;
GAFGLAS® #80 UltimaT" Base Sheet adhered in a full mopping of hot asphalt: applied at 20-
40 _lbs./sq. installed per manufacturer's installation instructions.
Cap Sheet:
(Optional) One_ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-Ply® BUR. Granule Cap
Sheet or GAFGLAS® EnergyCap.'" Mineral Surfaced Cap Sheet adhered in a- full mopping of
approved. asphalt appliedwithin the EVT range and at a rate of 20-40- lbs./sq. installed -per
manufacturer's installation. instructions.
Surfacing:
Optional on granular surfaced: membranes; required for smooth. membranes. Chosen
components must be applied according to; :manufacturer's application instructions. All.
coatings must be listed within a current NOA.
1. Gravel or slag applied at 400 lbs:/sq. and 300 lbs./sq. respectively in a flood .coat of approved
Asphalt at .60' lbs./sq. -
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied, at 0.5 to 0.75 gal./sq.(to be used as a -primer) followed by Topcoat°
Membrane applied at 0.5 to 0.75 gal./sq.
3. Fiber Aluminum Roof Coating.
Maximum. Design
Pressure: 45 psf: (See.General Limitation.#7)
Reviewed
for
Code Compliance
10/03/17
MIAMMADE COUNTY
NOA No.: 14-10301
Expiration Date; 11/04/18
Approval Date: 05/04/17
Page 21 of 31
Membrane Type:
BUR
Deck Type 1I:
Wood,1
Deck Description:
19/32" c
and inte
System Type C(2):
All laye
All General and System Limitatia
Fire Barrier: Fire0i
(optional) Solo,"
One or more layers of any of the fo
Base Insulation Layer (Optional)
EnergyGuardT. Polyiso Insulation_ ,
Minimum 1" thick
greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end
nediate supports with 8d.ring shank nails to supports spaced 24 in. o.c. at max.
of insulation are me-chanically.attached to roof deck. Membrane is
itly fully adhered to insulation.
Shall apply.
Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield®
•e-Resistant Slip Sheet.
insulations.
Insulation Fasteners Fastener
(Table 3) Density/ft'
RA Polyiso Insulation, .EnergyGuardTM RN Polyiso Insulation
N/A N/A
Note: All layers shall .be simultaneously fastened; see to layer below for fasteners and density. Insulation
panels listed are minimum sizes anil' dimensions; if larger panels are used, the number of fasteners. shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent° Perforated Venting Base Sheet
laid dry' or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on all
polyisocyanurate applications.
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft'
SECUROCK® Gypsum -Fiber Rool Board
Minimum '/4" thick 2,8 1:1.18 fe
Base Ply: Two or more plies of GAFGLAS® F1exP1yTM 6 adhered with hot asphalt applied at 20-25
lbs./sq. installed per manufacturer's installation instructions.
Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or
GAFGLAV EnergyCapT"' Mineral Surfaced Cap Sheet adhered with hot asphalt applied
at 20-25 lbs./sq. installed per manufacturer's installation instructions
Surfacing: Option) 1 on granular surfaced membranes; required for smooth membranes.
chose components must be.applied according to manufacturer's application
instructions. All coatings must be listed within a current NOA.
1. Gravel pr slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoa ®-Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
Review pcoalt° MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
for Topcoat' M.ei ibrane applied.at 0.5 to 0.75 gal./sq.
RUN
in m Roof CoatingMax g InCOrftpfiftti e
Pres ure: 1.0/03/ t7o pl. (See eneral Limitation #7)
NOA No.: 14-1030AI
MIAMI-DADS CO. uNn Expiration Date: 11/04/i8
Approval Date:- 05/04/17
Page 22 of 31
Membrane. Type: BUR
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or-wood.plank secured.6 in.. o.c. at panel end and.intermediate
supports with 8d ring shank nails to supports: spaced 24 in. o,c., at max.
System Type D: All 'insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is
subsequently mechanically fastened through insulation to the roof deck.
All General and System Limitations shall apply.
One or more layers .of.any of the following. insulations.
Insulation Layer- Insulation Fasteners Fastener
(Table 3) Density/ft'
EnergyGuard'" Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation; EnergyGuard'" RA Polyiso
Insulation
Minimum 1:3" thick N/A N/A
StructodeV High. Density Fiber Board
Minimum 1" thick
N/A
N/A
Note: Insulation shall have. preliminary attachment, prior to the installation of the base sheet, at a minimum
application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft:; and
four fasteners for any insulation board -having no dimension greater than '8 ft. All layers of insulation, optional
thermal barrier (when present) and base sheet shall be simultaneously fastened: See base sheet below for
fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Fire Barrier: FireOut" Fire -Barrier Coating, VersaShield®Fire Resistant Roof Deck Protection,
(optional) VersaShieldl .Solo'" Fire -Resistant Slip. Sheet, DensDecke Roof Board, Securock"Glass-
Mat Roof Board or Securock'" Gypsum Fiber Roof Board.
Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS' #80
Ultima Base Sheet, GAFGLAS° Stratavent® Nailable Venting Base Sheet or Ruberoid®
20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as
described below;
Fastening Drill-Tec' #12 Fastener or Drill=Tec'M #14 Fastener and Drill-Tec'" 3" Steel Plate, Drill -
Option #1: Tee 3 in. Ribbed Galvalume Plate (Flat), Drill -Tech' AccuTrac® Flat Plate or Drill-Tec'"
AccuTracm Recessed Plate is installed through the base sheet and insulation in 3 rows 12"
o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12"
o.c. in the field of the sheet.
(Maximum Design Pressure —45 psf. See General Limitation #7)
Fastening Drill=Tec'" #12 Fastener or Drill-Tec'" #14 Fastener and Drill -Tee'" 3" Steel Plate, Drill=
Option #2: Tee 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec" AccuTrac® Flat Plate or Drill-Tec'"
AccuTracm Recessed Plate is installed through the base sheet and insulation in 4 rows 8"
o:c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9"
o.c. in the field of the sheet.
(Maximum Design Pressure —75 psf.. See General Limitation #7)
Fast . ning GLAS® #8 Ultima'°' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth
Reviev
Opt' DR #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1"
for into the wood su strate and inverted Y' steel plate at a.fastener spacing of 9" o.c. at the 4"
M o r ws staggered with a fastener spacing of 9" o.c. in the center of the -
Code CO rane. Not . or use with DensDeck or Securock Fire Bar-rier
10/03 iimum Desi gn Pressure -60 psf See General Limitation #7)
NOA No.: 14-10301
M1AMMADE couNnr Expiration Date: 1.1/04/18
Approval Date: 05/04/17
Page 23 of 31
Fastening (Continued) Drill-TecT i #12 Fastener or Drill-Tee"#14 Fastener and Drill-TeeT" 3" Steel Plate, Drill -
Option #4: Tee 3 in. Ribbed Galvalume Plate (Flat),; Drill=TecT" AccuTracm Flat Plate or Drill=TecT`
AccuTrac Recessed Plate in 4 rows-12" o.c. One row is in the 2" side lap. The other rows
are equall� spaced approximately 9" o.c. in the field of the sheet.
(Maximu � Z Design Pressure —60 psf. See General Limitation #7)
Ply Sheet: One or more plies of GAFGLAS® Ply 4; Tri-Ply® Ply 4, GAFGLAS® F1e. y m 6 or
GAFGLA$® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied
within the IEVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation
Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply BUR Granule
Cap Sheet or GAFGLAS® EnergyCapT"" Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within -the EVT range and at a rate of 20-40 lbs./sq.
installed tier manufacturer's installation instructions.
Surfacing: Optional Ion granular surfaced membranes; required for smooth membranes. Chosen
components must. be applied according to manufacturer's application instructions.
All coati fgs must be listed within a current NOA.
1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to, be used as a primer) followed by
Topcoat® Membrane applied at 0..5 to 0.75 gal./sq.
3. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Faste iing Options
Reviewed
for
Code Compliance
10/03/17
NOA No.: 14-1030:01
MIAMFDADEcouNTY Expiration Date: 11/04/18
Approval Date: 05/64/17
Page 24 of 31
Membrane Type:
BUR
Deck Type 1:
Wood, Non=insulated
Deck: Description:
19/32" or greater plywood -or wood plank.decks secured 6 in.: o.c.. at panel end and
intermediate supports with 8d ring shank -nails to supports. spaced 24 in. o.c. at max.
System Type E(1):
Anchor sheetmechanically attached to.roof deck.
All General and System Limitations shall apply.
Fire Barrier:
Topcoat® FireOut" Fire Barrier Coating, VersaShield®Fire Resistant Roof Deck
(optional)
Protection, VersaShield® SoIoTM Fire=Resistant. Slip Sheet installed per manufacturer's _
installation instructions.
Base sheet:
GAFGLAS®#80 UltimaT' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid®
20 Smooth, Ruberoid® SBS Heat -Weld" Smooth or Ruberoid® SBS Heat -Weld"' 25 base
sheet mechanically, fastened to deck as described below;
Fastening
GAFGLA'Flex ply TM 6, GAFGLAS® #75 Base She et;_Tri-Ply° #75 Base Sheet or any of
Option #1:
the above anchor sheets attached to deck with approved annular ring shank nails and tin
caps at a fastener spacing 0f9" o.c. at the 4" lap staggered and in two rows 9" o.c, in the
field.
(Maximum -Design Pressure .-52.5.psf:. See General Limitation #7)
Fastening
GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid® 20 Smooth or Ruberoid® Mop Smooth
Option #2:
attached to .deck with approved 1 �'/a" annular ring shank nails and inverted 3" steel plate at a
fastener spacing of 9" o.c. at the 4" lap and in two .rows:staggered with :a fastener spacing of,
9" o.c. in the center of the membrane.
(Maximum. Design Pressure —60 psf... See General Limitation #7)
Ply Sheet:
One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4. or GAFGLAS® #80 Ultima Base
Sheet. adhered in a full. mopping of approved asphalt applied within the EVT range -and at a
rate of.20-40 lbs./sq:. installed per manufacturer's installation instructions.
Cap Sheet:
(Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule
Cap, Sheet or GAFGLAS,EnergyCap" Mineral Surfaced Cap Sheet adhered in a full
mopping of approved asphalt applied within the EVT range, and at a rate of 20-40 lbs./sq.
installed per: manufacturer's installation instructions..
Surfacing:
Optional on granular surfaced membranes;: required for smooth membranes. Chosen
components must be.applied according.to manufacturer's application instructions.
All coatings must be listed within a current NOA. .
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively ina flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Revi ewoat® Meml
for Fiber Aluminun
tPNgComb1, nce
10/03�1 �astemng C
MIAMI-DADS COUNTY
isapplied at 0.5 to 0.75 gal: sq.(to be used as a pnmer) followed by
ane applied at 0.5 to. 0.75 gal./sq.
Roof Coating.-
.....
..
NOA' No.: 14-1030;01
Expiration Date: 1.1/04/18
Approval Date: 05/04/17
Page 25 of 31
Membrane Type:, BUR
Deck Type 1: Wood,
Deck: bescription: 19/32"
System Type E(2): Anchor
All General and System Limitath
Fire Barrier:
(optional)
Anchor sheet:
Ply Sheet:
Cap Sheet:
Surfacing.:
Maximum Design
Pressure:
111
r�greater plywood or wood plank decks secured 6 in. _o.c. at panel end and
iate supports with 8d ring shank nails to supports. spaced 24 in., o.c. at max.
I eet mechanically attached to roof deck. .
's shall apply. PP y
' FireOutTM Fire Barrier Coating, VersaShielde Fire Resistant Roof Deck
VersaShield° S016TM Fire -Resistant Slip Sheet installed per manufacturer's
�n instructions.
GAFGLAS® #80 Ultima Base Sheet mechanically attached with Miami -Dade County
Approved min. 1'/4 long, 12-ga., annular ring shank nails and 1-5/8" diameter tin caps
spaced 7'� o.c. in the min 4" wide side laps and in 3 staggered rows in the field of the sheet.
Two or }ore plies of GAFGLAS® Ply 4, Tri-Ply° Ply 4, GAFGLAS® F1exPly"° 6 adhered to
the base Sheet in fullmopping of approved asphalt applied within the EVT range and at a
rate of 2d-40 lbs./sq. installed per manufacturer's installation instructions.
One ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-P1yO BUR Granule Cap Sheet or
GAFGL SO EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per
manufac rei's installation instructions.
Optiona�'on granular surfaced membranes; required for smooth membranes. Chosen
components must be applied according to manufacturer'sapplication instructions.
All coatings must be listed within a current NOA.
1. Gravel orb slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoat" Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR .
Topcoat MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by
Topcoat Membrane applied at 0.5 to 0.75 gal./sq.
-82.5
Reviewed
for
Code Coft Tian
10/03/17
. (See General Limitation #7)
NOA No.: 14-1030.01
MIAMI-DADECQUNTIf Expiration Date: 11/04/19
Approval Date: 05164/17
Page 26 of 31
Membrane Type:
BUR
Deck Type lI:: =
Wood, .Non Insulated
Deck Description:
Min: 15/32" thick.or.greater. plywood or wood plank secured 6 in..o.c. at panel end and
intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c.,at.max,
System Type E(3)::
Anchor sheet mechanically attached to roof deck.
All General and System Limitations shall apply:
Fire Barrier:
TOPCOAT Fire OutTM Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or
(optional)
VersaShieldO S0loTM Fire -Resistant Slip Sheet installed per manufacturer's installation
instructions.
Anchor sheet: :
GAFGLAS® #75 Base Sheet,. Tri-Ply® #75 Base Sheet, Ruberoide 20 Smooth or
GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as.described below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5%8: in..
Option #1:
diameter tin caps are spaced.8 in. (i.e. in the min. .4 in. wide anchor sheet side laps and 8
in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure: —45 psf. See General Limitation #7) .
Fastening
Miami -Dade County Approved. mina 12 ga. annular ring. shank nails and mire. l-5/8 in.
Option #2:
diameter tin caps .are spaced:6 :in. -o.c. in the min :4 in. wide anchor sheet: sidelaps. and 6
in. o.c. in the field of the sheet in two staggered rows.
(Maximum Design Pressure: —52.5 psf. See General Limitation #7)
Fastening
Drill -Tee' #14fasteners and Drill-TecT"' 3 in. Standard.Steel Plates, Dr 1l-TecT"
Option #3:
AccuTrac® Flat Plates or Drill-TecT" 3 in.. Ribbed Galvalume Plate (Flat) are spaced:16
in. o.c. in the min. 4 in. wide .anchor sheet side laps. and 16in. o.c. in the field .of the sheet
in two staggered rows.
(Maximum Design Pressure: -52.5 psf. See General Limitation #7)
Fastening
TM
Drill-Tec' #14 Fasteners and Drill -Teel" 3 in. Standard Steel Plates, Drill-TeC
Option #4:
AccuTrac® Flat Plates or Drill-TecT 3 in. Ribbed Galvalume Plate (Flat) are spaced 12
in. o.c. in the min 4 in._ wide anchor sheet side laps and 12 in. o.c. in the field of;the sheet
in two staggered rows.
(Maximum Design Pressure: —60 psf. See General Limitation #7)
Fastening .
PrillJecTM #14 Fasteners and Drill TecT'" 3 in. Standard Steel Plates, DrillJecTM
Option 95.
AccuTrac® Flat Plates .or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in.
o.c. in the min.:4 in. wide anchor sheet side laps and 8 in. o.c. in the field:of:the sheet in
three staggered rows.
.(Maximum Design Pressure: —97.5 psf. See General Limitation #7)
Ply Sheet:
When optional cap sheet is present:
Two or more plies of GAFGLAS® Ply 4, Tri-Plye Ply 4, GAFGLAS® Flex Ply 6 adhered
.LULL L`FF
ng of hot asphalt applied at 20-401bs./sq. installed per manufacturer's
Reviewed tallation instructions.
for
When optiona
cap sheet is not present:
or
Code CompWr
plies ofGAFGLASO Ply 4, Tri-Ply° Ply 4, GAF.GLAS® Flex Ply6
. a
11 mopping. of hot asphalt applied at 20-401bsJsq:.installed per
1.0/03/1ganufacturer'
installation instructions.
NOA No.: 14-1030.01
MIAMI-DADE COUNTY
Expiration -Date: 1.1/04/18
• •
Approval Date: 05/04/17
Page 27 of 31
Cap Sheet: (Optional) GAFGLAS° Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet
or GAFGLAS EnergyCapT' Mineral Surfaced Cap Sheet adhered in a full mopping of hot
asphalt (applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions.
Surfacing: Optional on granular surfaced -membranes; required for smooth membranes.
Chosen components must be applied, according to manufacturer's application
instructions. All coatings must be'listed within -a current NOA.
Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of
approved asphalt at 60 lbs./sq.
2. Topcoat° Membrane or Topcoat® Surface Seal S:B applied at 1 to 1.5 gal./sq.
OR
Topcoat° MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer). followed by
Topcoat° Membrane applied at 0.5 to 0.75 gal./sq.
I. Fiber Aluminum Roof Coating.
Maximum Design
Pressure: See Fa tening Above.
Reviewed
for
:-Code Compliance
1.0/03/17
NOA No.: 14-1030:01
MIAMFDADECOUNTr Expiration Date: 11/04/19
• • Approval Datec 05/04/17
Page 28 of 31
e
Membrane Type: BUR
Deck Type 1I: Wood', Non Insulated
Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and
intermediate supports with ,8d ring shank nails to supports spaced 24 in. ox. at max.
System Type E(4): Anchor sheet.mechanically attached to roof deck.
A11 General and SY stem Limitations sh 11 1
a aPP. Y•
Fire Barrier:
TOPCOAT FireOutTM. Fire Barrier Coating, Versa Shield® Fire -Resistant Slip Sheet. .
(optional)
VersaShield® SoloT"' Fire -Resistant Slip Sheet, installed perm' ufacturer's installation
instructions.
Anchor sheet:
GAFGLAS® #75 Base Sheet; Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS®
Stratavent® Venting Nailable Base'Sheet is secured as described below.
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter
Option #1:
tin :caps are spaced 8, in. o.c. in the min. 4 in, wide_ anchor sheet side laps and 8 in. o.c::in .the
field of the sheet: in two staggered rows:
(Maximum Design Pressure: —45 psf. See General Limitation #7)
Fastening
Miami -Dade County Approved min. 12 ga. annular ring shank nails. and min. 1-5/8 in. diameter
Option #2:
tin caps are spaced: 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in.-o.c. in the
field of the sheet in two staggered rows.
(Maximum -Design Pressure: —52.5 psf. See General Limitation #7)
Fastening
Drill-TecTM #1:4 Fasteners and Drill-TecTM 3 in. Standard Steel .Plates, Drill-TecTM AccuTrac®
Option 93:
Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4
in. wide anchor sheet side laps and 16 in. o.c: in the field of the sheet in two staggered rows.
(Maximum Design Pressure: =52.5 psf. See General Limitation #7)
Fastening
Drill-TecTM #14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates, Drill-Tec M AccuTrac®
Option ##4:
Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4
in. wide anchor sheet side laps and 12 in. o.c: in the field of the sheet in two staggered rows.
(Maximum Design Pressure: —60 psf. See General Limitation #7)
Fastening
Drill=TecTM' #14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates; Drill-TecTM Accu:Trae
Option #5:
Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4
in. wide anchor_ sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows.
(Maximum Design Pressure: -97.5 psf. See General Limitation #7)
Base Sheet:
Ruberoid' 20 Smoothadhered in a full mopping of -hot asphalt applied at 20-4.0 lbs./sq.
installed per manufacturer's installation instructions.
Cap Sheet:
GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS
EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20
— 401bs./sq. installed per manufacturer's installation instructions.
Reviewed
for
Code Compliance
1.0/03/17
MIAMFDADE COUNTY
NOA No.: 14-1030.01
Expiration Date: H/04/18
Approval Date: 05/64/17
Page 29 of 31
Surfacing:
Optional on granular surfaced membranes; required for smooth membranes. Chosen
components must be aippfied according to manufacturer's application instructions. All
coatings must be listed within a curre.nt,NOA.
1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq: respectively in a flood coat of approved
asphalt at 60 lbs./sq.
2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq.
OR
Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat®
Membrane applied at 0.5 to 0..75 gal./sq.
3. Aluminum FI 'ber Roof Coating.
Maximum Design
Pressure: See Fastening Above.
Reviewed
for
Code Compliar
10/03/17
NOA No.: 14-1030:01
MIAMI-DADE COUNTY Expiration Date: 11/04/1$
• Approval Date: 05/04/17
Page 30 of 31