Loading...
HomeMy WebLinkAboutNOARECEIVE SCANNED / D' By MIAMI-DARE St L.Ude COUMY JAN. 2' 9 2018 MIAMI-DADE COUNTY .. . PRODUCT -CONTROL SECTION ST. Lucie County, Permitting 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER).: Miami, Florida 33175-2474 . BOARD AND CODE ADMINISTRATION DIVISION T (786)31:5-2590 F (786) 31.525-.99 -NOTICE OF ACCEPTANCE. (NOA) www.niiamidade.gov/economy GAF 1:Campus Drive Parsippany,. NJ 07054 SCOPE:. This NOA is being issued; under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER Product Control Section to be used in Miami Dade County and other areas :where allowed by the Authority Having Jurisdiction (AHJ);. This NOA shall -not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In. Miami Dade County.) and/or the AHJ (in areas other than Miami Dade County) . reserve the right to have this product or material .tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur. the expense of such testing and the AHJ may immediately revoke, modify, or suspend the .use of such.product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is, determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of 'the Florida Building Code. DESCRIPTION: GAF Conventional Built -Up Roof Systems for Wood Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless. otherwise noted.herem. RENEWAL of this NOA.shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process-. Misuse of this NON as an endorsement of any product, for sales, advertising or any other purposes. shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA.. ADVERTISEMENT: The. NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. shall at Ahis NOA revisef opA No. 134022.1 1 Q703/17 MIAMI-DADE COUNTY )A shall be provided to. the, user by the manufacturer or its distributors e job site at the request of the Building Official. r, and consists of pages 1 through Jff Aft ✓ed by.Jorge L. Acebo.LAW 0 NOA No.: 14-1030:01 ' Expiration - Date: 11/04/18 . Approval Date: 05/04/17 Page 1 of 31 ROOFING SYSTEM APPROVAL Category: Roofing Sub-Cate2ory: BUR Material: Fibergh Deck Type: Woodl Maximum Design Pressure: -97.5 Ps TRADE NAMES OF PRODUCTS N Product Dimensions GAFGLAS® Ply 4 39.37" (1 meter) Wide Tri-Ply® Ply 4 39.37" (1 meter) Wide GAFGLAS® 39.37" (1 meter) F1exPly'. 6 Wide GAFGLAS®#75 39.37" (1 meter) Base Sheet Wide Tri-Ply®#75 Base 39.37" (1 meter) Sheet Wide GAFGLAS® #80 39.37" (1 meter) Ultima'T" Base Sheet Wide GAFGLAS® 39.37" (1 meter) Stratavent® Wide Perforated Venting Base Sheet GAFGLAS® 39.37" (1 meter) Stratavent® Nailable Wide Venting Base Sheet Ruberoid® 20 39.37" (1 meter) Smooth Wide Ruberoid® Mop 39.37" (1 meter) Smooth wide Ruberoid® Mop 39.37" (1 meter) An Wicie 5evievqo xoid®pp3 .3, (I meter) Smooth for, wide :i!1,QdevG0" 4A Geer) 3th 10/03/17wide MIAMMADE COUNTY JUFACTURED OR LABELED BY APPLICANT: TABLE I Test Product Specification Description ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced with fiberglass mat. ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced with fiberglass mat. ASTM D2178 Smooth surfaced asphaltic ply sheet reinforced with fiberglass mat. ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass mat. ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass that. ASTM D4601 Smooth asphaltic base or base/ply sheet reinforced with fiberglass mat. ASTM D4897 Smooth surfaced asphaltic perforated venting base sheet reinforced with fiberglass mat. ASTM D4897 Smooth surfaced asphaltic nailable venting base sheet reinforced with fiberglass mat. Bottom side surfaced with granules. ASTM D6163 SBS polymer -modified asphalt base or anchor sheet reinforced with a fiberglass mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet reinforced with a polyester mat. ASTM D6164 Smooth surfaced mop applied SBS base or anchor sheet: reinforced with a polyester mat. ASTM D6163 Smooth surfaced torch applied SBS base or anchor sheet reinforced with a fiberglass mat. NOA No.: 14-1030:01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 2 of 31 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE I .. .. Test Product Product Dimensions Specification . . .. Description Ruberole HW . 39.37" (1 meter) ASTM D6164 Smooth surfaced torch applied SBS base or anchor Smooth wide sheet reinforced With a polyester mat. GAFGLAS® X37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Mineral Surfaced Wide with fiberglass mat. Cap Sheet _. Tri=.Ply® BUR 39.:37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced Granule Cap Sheet Wide with fiberglass mat. GAFGLAS° 39.37" (1 meter) ASTM D3909 Granule surfaced asphaltic cap sheet reinforced EhergyCapTM Wide with fiberglass mat. Cap.sheet is factory coated Mineral Surfaced with TOPCOAT® EnergyCoieTM Elastomeric Cap Sheet Coating. Topcoat® Surface 5 or 55 gallons ASTM D6083 Solvent -based thermoplastic. rubber Seal SB sealant designed:to protect and restore aged roof surfaces and to increase roof reflectivity. Topcoat® 1, 5 or 55 gallons ASTM D6083 Water -based elastomeric coating Membrane Topcoat® MB Plus 5 or 55 gallons Proprietary Water based, low VOC primer designed to block asphalt bleed -through. Topcoat° FireOut' 5 or 55 gallons Proprietary Low VOC, water based fire barrier coating. Fire Barrier Coating VersaShield® Fire- 12" x 100' rolls ASTM D226 Non -asphaltic, fiberglass reinforce_ d underlayirient Resistant Roof and/or fire barrier Deck Protection VersaShield° SoIoTM 42" roll wide, 100 ASTM D146, Non -asphaltic, fire resistant fiberglass Fire -Resistant Slip ft. D828, D4$6.9; underlayment Sheet D6757 Topcoat® 1,.5 gallons or TAS 139 Solvent -based elastomeric sealant. FlexSealTM 1 qt. tube Reviewed for -Code Compliance 1 Q/03/17 MIAMI-DADE COUNTY NOA No.: 14-1030:01 Expiration Date: 1.1/04/18 Approval Date: 05/04/17 Page 3-of 31 APPROVED INSULATIONS: Product Name EnergyGuard"' Polyiso Insulation EnergyGuardTM Tapered Polyiso Insulation EnergyGuard" Ultra Polyiso Insulation EnergyGuard' RA Polyiso Insulation EnergyGuard" RA Composite Polyiso Insulation EnergyGuard" RH Polyiso Insulation EnergyGuard"' RH Tapered Polyiso Insulation EnergyGuard" RN Polyiso Insulation EnergyGuard" Perlite Roof Insulation EnergyGuard'" Perlite Recover Board Securock® Gypsum -Fiber Roof Board Securock® Glass -Mat Roof Board Structodek® High Density Fiber Board Roof Insulation DensDeck® Prime Roof Board DensDeck® Roof Board TABLE 2 Product Description visocvanurate foam insulation foam insulation polyisocyanurate foam insulation Pol, isocyanurate foam insulation Polyisocyanurate foam insulation with high denl�ity fiberboard or permalite Polyisocyanurate foam insulation Polj isocyanurate foam insulation Pol, .isocyanurate foam insulation Perlite insulation board Perlite recover board Gyp 3um board Glass faced gypsum board High density fiberboard Gyp um board n GvI um board Reviewed for Code Compliance 10/03/17 MIAMFDADE COUNTY Manufacturer (With Current NOA) GAF GAF GAF GAF GAF GAF GAF GAF GAF GAF United States Gypsum Corp. United States Gypsum Corp. Blue Ridge Fiberboard, Inc. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC NOA No.: 14-1030AI Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 4 of 31 APPROVED FASTENERS; TABLE: 3 Fastener Product Product Manufacturer: Number .Name . Description Dimensions (With Current: NOA).. L Drill-Tec' #12 Fastener' Phillips head; modified #12-x 8'' max. GAF buttress thread, pinch -point,:. length, #3 carbon steel fastener for use Phillips head. in steel or wood decks. With CR-10 coating. Available. with a pinch point or drill point. 2. Drill -Tee. #14 Fastener Truss head, self. -::drilling, #14 x 16" GAF. pinch point, high thread max. length, fastener for use in steel, wood . #3 Phillips or concrete decks. head. 3. Drill-TecT"' ASAP 3S Drill-TecT"' #12 Fastener with See GAF brill-TeCT" 3" Standard Steel components Plate. 4. Drill-TecT"' 3" Steel .Plate Round Galvalume® steel 3" Round GAF stress plate with reinforcing ribs and recessed for use with Drill-Tec`"' fasteners. 5:. Drill-TecT"' 3" Standard Steel Galvalume® coated steel 3" Round GAF Plate stress plate for use with approved Drill-Tec"m fasteners. 6. Drill-TecT" AccuTrac®Flat A2-SS aluminized steel plate 3" square; GAF Plate for use with Drill-TecT"' :017" thick fasteners: 7. Drill-TecT" AccuTrae Galvalume® steel plate with 3" square; GAF Recessed Plate recess for use with Drill- .017" thick TecT°' fasteners. 8. Drill-Tec 3 in. Ribbed Round Galvalume® plated 3" Round GAF Galvalume Plate (Flat) steel stress plate with reinforcing ribs for use with DrilfmtecT' fasteners. Reviewed for Code Compliance 10103/17 MIAMI-DARE COUNTY NOA No.: 14-1030:01. Expiration Date: 11/04/18 Approval Date! 65/04/17 Page 5 of 31 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corp. UL LLC PRI Construction Materials Technologies, LLC Reviewed for Code Compliance 1.0/03/17 MIAMI-DADE COUNTY Test Identifier Description Date 3014547 4470 05/22/03 302-9832 4470 0.5/ 11 /07 3033135 4470 11 /24/08 3034312 4470 04/09/09 3036980 4470 08/14/09 3038278 4470 11/18/11 3040738 4470 11 / 16/ 10 30.417.60 4470 05/26/11 3042887 4470 11/14/11 3042905 4470 O 1 /10/ 12 3046081 4470 02/13/13 3047636 4470 08/08/13 ODOA8.AM 4470 07/09/99 OD 1 A8.AM 4470 07/29/94 OY9Q5.AM 4470 04/01 /98 1139A8.AM 4470 09/04/91 2138A4.AM 4470 07/02/97 3139Q LAM 4470 01 /08/98 3D4Q2.AM 4470 05/30/97 797-03221-267 4470 09/27/07 797-03825-267 4470 07/21 /08 197-10228-267 4470 01/23/15 R1306 UL 790 04/04/17 GAF-012-02-02 ASTM D4977 11 /06/01 GAF-020-02-01 ASTM D4977 02/01 /02 GAF-082-02-01 ASTM D6083 05/07/06 GAF-084-02-01 ASTM D6083 05/09/06 GAF-122-02-01 TAS 139 05/07/06 GAF-270-02-02 ASTM D226 11/15/10 GAF-276-02-01Rev ASTM D6083 12/16/10 GAF-276-02-62 ASTM D226 11/15/10 GAF=306-02-01 ASTM E96 07/07/11 GAF-314-02-01 ASTM D2178 08/23/11 GAF-315-02-01 ASTM D2178 08/23/11 GAF-369-02-01 ASTM C1289 10/22/12 GAF-417-02-01 ASTM C1289 05/28/13 GAF-464-02-01 ASTM C1289 10/22/12 GAF-464-02-01 ASTM C1289 02/06/14 GAF-499-02-01 ASTM D6083 03/12/14 GAF-500-02-01. ASTM D6083 03/12/14 GAF-549-02-01 TAS 114 08/08/14 GAF-549-02=02 TAS 114 08/08/14 GAF-559-02-01 TAS 117(13) 09/3.0/14 .. NOA No.: 14-1036M Expiration Date: 11/04/19 Approval Dater 05/04/17 Page 6 of 31 EVIDENCE SUBMITTED: (CONTINUED) Test Agency Test Identifier PRI Construction Materials. GAF-559-02-04 Technologies; LLC GAF-559-02-05 GAF-559-02-06 GAF-559-02-W GAF-559=02-08 GAF-559=02=09 GAF-559-02711 GAF-559-02-12 GAF-559-02-13 GAF-559-02-14 GAF-559-02-15 GAF-559=02-16 GAF-559-02-18 GAF-559-024.9 IRT of S. Fl. 02=005 02=014 Trinity I ERD C8500.SC.1 Loi G30250:02.10-3-R2 . .G31360.03.10 G33470.01.11 034.140.04.11-2 G34140:04.11-4-R2 G34140.04.11-5-R3 G36780.07.11-R 1 G40630.01.14-1 G40630.61.14-2A G40 63 0.01.14-2 A-1-R 1 G43610.01.14 G6,850.08.07-1 SC6870.08.14=R.1 Atlantic & Caribbean Roof 11-053 Consultants, LLC Reviewed for Code Compliance 10/03/17 MIAMI-DADE COUNTY Description ASTM D 1876 ASTM D .1876 TAS, 114(H) ASTM D 903 ASTM D 903 ASTM D 903 .TAS 114 TAS 114 TAS 114. TAS 114 TAS 114. TAS 114 TAS.114 :TAS 114 TAS 114 TAS 114 TAS 117 ASTM D3909 ASTM D61'64 ASTM D6164 ASTM 06163 ASTM D6401 ASTM 134897 4470-TAS 114 ASTM D6163 ASTM D6164 ASTM-D6164 -ASTM D3909 ASTM D3909 ASTM D3969 TAS 114 Date 10/01/14 10/15/14 1.0/02/14 10/02/14 10/02/14 10/02/14 10/14/14 10/14/14 10/15/14 10/15/14 101151..14 10/15/14 10/15/14 04/16/15 01/18/02 03/22/02 1-1 /30/07 06/03/15 03/31/10 11/16/11 04/25/11 06/04/15 06/04/15 07/18/11 01/06/14 01/67/14 04/10/14 01/22/14 08/13/07 09%04/ 14 08/12/.1.1 NOA No.: 14-1030,01 Expiration Date: 1.1/04/18 ' Approval Date: 0 04/17 Page 7 of 31 APPROVED ASSEMBLIES Membrane Type: BUR Deck Type 11: Wood,. Deck Description: Min. 19/32�,' or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate su: pports with 8d ring shank nails to supports spaced 24 in. o.c. at max. System Type A(1): All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall a pply. Fire Barrier: Topcoat® FireOutT"' Fire Barrier Coating, VersaShielde Fire -Resistant Roof Deck Protection, (optional) VersaShield16 Solo- Fire -Resistant Slip Sheet, DensDeck®Roof Board, Securock® Glass - Mat Roof Board or Securock" Gypsum Fiber Roof Board installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS�II #80 Ultima" Base Sheet, GAFGLAS® Stratavent® Nailable Venting Base Sheet or Ruberoid' 20 Smooth mechanically fastened as described below: Fastening GAFGLAS Ply 4, GAFGLAS® Flex plyT. 6, GAFGLAS® #75 Base Sheet or any of above Option #1: anchor shee s.attached to deck with approved annular ringshank nails and tin caps at a fastener spacing of 9" o.c. at the lap staggered and in two rows 12" o.c. in the field. Not .for.use with DensDeck or Securock Fire Barrier (Maximum esign Pressure .-45 psf. See General Limitation #7) Fastening GAFGLASI Ply 4, GAFGLAS® FlexPly'"' 6, GAFGLAS® #75 Base Sheet or any of above Option #2: anchor sheets attached to deck with Drill=TecT" #12 Fastener, Drill-TecT" #14 Fastener and Drill-TecT' 3" Steel Plate, Drill-Tec'�" AccuTrac® Flat Plate or Drill-TecT" AccuTrac® Recessed Pate 1.2" o.c. in 3 rows: One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #7) Fastening GAFGLAS® F1exPlyT" 6, GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet or any of Option #3: above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing of 9" o.c. at the 4" lap staggered and in two rows 9" o.c. in the field. Not for use-With.D.ensDeck or Securock Fire Barrier (Maximum Design Pressure —52.5 psf. See General Limitation #7) Fastening Any of the above anchor sheets attached to deck with approved 1'/4" annular ring shank nails Option #4: and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two rows staggered with a fastener spacing of 9" o.c. in the center of the membrane. Not for use�with DensDeck or Securock Fire Barrier (Maximum Design Pressure —60 psf. See General Limitation #7) Fastening GAFGLAS . #7.5 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" OptiTN'11-TecT" #14 Fastener and Drill-TecT"' 3" Steel- Plate; Drill-Tec' AccuTrace late o - Revie Dril -TecT' AccuTrac® Recessed Plate 12" o.c. in.4 rows. One row is in the 2" side ap. T e of er rows are equally spaced approximately 9" o.c. in the field of the sheet. for (Maximum Desi on Pressure —60 psf. See General Limitation #7) Code Com.p1jance 1.0/03/ 17 NOA No.: 14-1030M MIAMIOADEcoUNTY Expiration Date: 11/04/18 Approval Datec 65/64/17 Page 8 of 31 Fastening (Continued) Any -of above anchor. -sheets attached to deck approved annular ring shank nails and 3" Option #6: inverted Drill-TecT" insulation plates at a fastener spacing of 9" o.c. at the 4": lap, staggered in two rows 9" in the field. Not for use with DensDeck or.Securock Fire Barrier. (Maximum Design Pressure —60 psf. See: General Limitation. #7) Fastening GAFG1LAS®#75 Base Sheet or any of above anchor sheets attached to deck with Drill-TecT" Option #7: #12 Fastener or Drill-TecT" #14 Fastener and 3" Drill-TecT" 3" Steel Plate, grill-TecT°' AccuTrac® Flat Plate or Drill-TecT°' AccuTrac®:Recessed Plate. 8" o.c. in 4 rows. One row is in the 2" side lap.. The other rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure=-75psf. See General Limitation #7) One or more layers of any of the following insulations. Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft? EnergyGuardT" Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuard RH Polyiso Insulation, EnergyGuardT" RA Polyiso Insulation, EnergyGuardT" RA Composite Polyiso Insulation Minimum 1".thick N/A N/A EnergyGuardT" Perlite Recover Board, DensDeck® Prime_ Roof Board Minimum %Z" thick N/A. EnergyGuardT" Perlite Roof Insulation Minimum %1' thick N/A - N/A N/A Note: All insulation shall be adhered to the anchor sheet: i_n full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation panelsmay be used as a top layer placed with the polyisocyanurate: side facing down. GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuardT" Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Base Sheet: (Optional) Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Basel Sheet, GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid® Mop Smooth; Ruberoid® Mop Smooth 1.5, Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth, Ruberoid® HW Smooth or Ruberoid® HW 25 Smooth directly over the top layer of insulation. Adhere with any approved mopping asphalt applied within the EVT range and at a rate of 20-401bs./sq. applied in accordance with manufacturer's instructions. (see General Limitation #4). .OR GAFGLAS® Stratavent® Perforated Venting Base Sheet loose -laid dry (not for use with perlite. top layer insulation or composite polyiso top layer insulation). Ply Sheet: One.or more plies GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® F1exPlyTn' 6 or GAFGLAS®#80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied withinthe-EVT- range and at a rate of 2074.0 lbs./sq. installed per manufacturer's installation Revi.e t ctions. Cap heet: (Optional) One ly of GAFGLAS Mineral Surfaced Cap Sheet, Tri-Plye BUR Granule r 11 Ca . Sheet or G FGLAS®EnergyCa .. Mineral Surfaced Cap -Sheet adhered in a full Code Com ianc eppr ved asphalt applied within the-EVT range and at a rate of 20-40 lbs./sq. 10/03Mtf led per mar ufacturer's installation instructions. NOA No.: 14-1036.01 MIAMMADE COUNTY Expiration Date: 1.1/0449 Approval Date: 05/04/17 Page 9-of 31 Surfacing: Optional coatings i 1. Gravel or approved 2. Topcoat® OR Topcoat° Topcoat® 3. Fiber Alu Maximum Design Pressure: See F Reviewed for Code Comphan 1.0/03/17 MIAMI-DADE COUNTY granular surfaced membranes; required for smooth membranes. Chosen must be applied according to manufacturer's application instructions. All It be listed within a current NOA. g applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of halt at 60 lbs./sq. :mbrane..or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by ibrane applied at 0.5 to 0.75 gal./sq. m Roo fCoating. g Options. NOA No.: 14-1030:01 Expiration Date: 11/04/19 Approval Date: 05/04/17 Page 10 of 31 Membrane Type: Deck Type 1I: . Deck .Description: System Type A(2): BURsp Wood, Insulated Min: 15/32" thick or. greater plywood or wood plank secured 6 in. o.c. at panel end and .intermediate supports -with 8d ring shank. nails to supports spaced 24 in. o.c. At max. All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOuf" Fire Barrier Coating,. VersaShieldo Fire -Resistant Slip Sheet or (optional) VersaShieldm Solo"' Fire -Resistant Slip- Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS®#75 Base Sheet, Tri-Ply®.#75 Base Sheet; Ruberoidm.20 Smooth or GAFGLAS® Stratayento Venting Nailable Base Sheet is securedus described below. Fastening Miami -Dade County Approved mina 12 ga. Annular ring shank nails and. min. 1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c-. in the min: 4 in. wide anchor sheet side laps and 8. in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf See General Limitation #7) Fastening Miami=Dade County Approved min. 12 ga,. Annular ring shank nails and min. 1-5/8 in. Option.#2: diameter tin caps.are spaced 6 in. o.c. in, the:min 4 in. wide Anchor sheet side laps Arid 6 in: o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —'52.5 psf. See General limitation #7) Fastening Drill-TecTM #14 Fasteners and Drill-Te¢T" 3 in. Standard Steel Plates, Drill-TecTM Option #3: AccuTraco Flat Plates or Drill -Tee'" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide Anchor sheet side laps and 16 in. o.c. in the field of the sheet in two staggered rows. ... (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecTM #14 Fasteners and Drill=TecTM 3 in. Standard Steel Plates, Dri1l-Tec` Option #4:. AccuTrac® Flat Plates or Drill-TecTM 3. in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet: side laps and 12 in. o.c: in the field ofthe sheet in two staggered rows. (Maximum Design Pressure: =60 psf. See General Limitation #7) Fastening. Drill-TecTM #14 Fasteners and Drill -Too. 3 in. Standard Steel Plates, Drill-TecTM Option #5: AccuTrace Flat Plates or Drill=TecTM 3 in.' Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf .See General Limitation .#7) One or more layers of any of the following insulations. Base nsulati Layer Insulation Fasteners Fastener Reviewed (Table 3) Density/ft' Ener ;yGuard" P61 fell nsulation, Ener Guard"" Tapered Polyiso Insulation, EnergyGuard`" Ultra Polyiso Insu ,E�er uardT"H PoI iso I sulation, EnergyGuardT" RH Tapered Polyiso Insulation Min] n1mi k�Ol�pllanC;e N/A N/A 10/03/17 NOA No.: 14-1030M MIAMFDADEcouNTY Expiration Date: 1.1/04/18 Approval Date: 65/64/17 Page 11 of 31 Top Insulation Layer EnergyGuard" Perlite, Roof Minimum'/a" thick Structodek® High Density Minimum %2" thick - Securock® Gypsum -Fiber Roof Minimum '/a" thick Roof Insulation Insulation Fasteners (Table 3) N/A N/A DensDeck® Prime Roof Board N/A Fastener Density/ft2 N/A N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet (Optional): GAFGL S® #75 Base Sheet, Tri-:Ply® #75 Base Sheet, Ruberoid® 20 Smooth adhered in a full mopping of hot asphalt applied at.20-401bs./sq. installed per manufacturer's installation instructions. Ply Sheet: When optional base sheet and/or cap sheet is present: Two or more piies.of GAF. GLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied at 20-40 lbs./sq. installed per manufacturer's installation instructions. When optional base sheet and/or cap sheet is not present: Three or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered* a full mopping of hot asphalt applied at 20-401bs./sq. installed per manufac rer's installation instructions. Cap Sheet (Optional): GAFGL JASo Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLASo EnergyCap'" Mineral Surfaced Cap .Sheet adhered in a full mopping of hot asphalt aplied at 20 — 40 lbs./sq: installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approve asphalt at 60 lbs./sq. 2. Topcoat Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat`' MB Plus applied at 0:5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoatq Membrane applied at 0.5 to 0,75 gal./sq. 3. Aluminu'F Fiber Roof Coating. Maximum Design Pres ure: fastening ptions above. Reviewed for Code Compliance 10/03/17 NOA No.: 14-10301 tyni4MraaDecoutvTY Expiration Date: 11/04/18 • • Approval Date: 05/04/17 Page 12 of 31 Membrane Type: BUR Deck Type 1I: Wood, Insulated Deck: Description: Min: 15/32" thick:or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c._at max. System Type A(3): All insulation layers are adhered, -to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and; System Limitations shall apply. Fire Barrier: Topcoat® FireOutT" Fire Barrier Coating, VersaShield° Fire -.Resistant Slip Sheet or (optional) VersaShield® Solo' Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet, Tri-Plym #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratayent® Venting Nailable Base Sheet is seciired.as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min..1-5/8 in. Option #1: diameter tin caps are spaced 8 in. o.c. in the min: 4 im wide anchor sheet side laps and 8 in. o.c. in the field of the'sheet in two staggered rows. (Maximum Design Pressure: —45 psf. 'See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. an ring shank nails and min. 1-5/8 in. Option.#2: diameter tin caps are.spaced 6 in. o.c. in the:min 4 in. wide:anchor sheet side laps. and:6 in. o.c. in the field of the sheet in two staggered rows._ (Maximum Design Pressure: -52.5 psf. See General. Limitation #7) Fastening Drill-TecT°' #14 Fasteners and Drill-TecT" 3 in. Standard Steel Plates, Drill-Tec' Option #3: AccuTrac° Flat Plates or Drill-TecT°' 3 in. Ribbed Galvalun e Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c. in the field of the . sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill=TecT" 3 in. Standard Steel Plates, Dri1l-TecT"' Option #4: AccuTrac® Flat Plates .or Drill-TecT°' 3 in. Ribbed Galvalume Plate (Flat) are'spaced 12 in. o.c. in the mini 4 in. wide anchor sheet side laps and 12 in. o.c: in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill-Tec'm.3 in. Standard Steel Plates; Drill-TecT"' Option #5: AccuTrac® Flat Plates or Dri11=TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: —75 psf See .General Limitation #7) Reviewed for -Code Compliance 10/03/17 MIAMI-DADE COUNTY NOA No.: 14-1030:01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 13 of 31 One or more layers of any of the folloN*ing insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3)- Density/ftz EnergyGuard'" Polyiso Insulation, nergyGuardT" Tapered Polyiso: Insulation, EnergyGuard"' Ultra Polyiso Insulation, EnergyGuard'" RH Polyiso Insulation, EnergyGuard"' RH Tapered Polyiso Insulation Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table.3) - Density/W EnergyGuard"" Perlite Roof Insulation Minimum 3/a" thick N/A N/A Structodek® High Density Fiberboa d Roof Insulation Minimum %2" thick N/A. N/A SecurocV Gypsum -Fiber Roof Board, DensDeck® Prime Roof Board Minimum %11 thick N/A N/A Note: All insulation shall be adhered in a full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft'. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base Sheet: Ruberoido 20 Smooth adhered in a full mopping of hot -asphalt applied at 20-40 lbs./sq. Cap Sheet: GAFGL A S® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS® EnergyCap'" Mineral Surfaced. Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 401bs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instruct'ions. All coatings must be listed within a current NOA. 1. Gravel instruct sla applied at 4001bs./s . and 3001bs./s . res ectivel in a flood coat of �' g pp q q respectively approved asphalt at 60 lbs./sq. 2. Topcoat Membrane or Topcoat' Surface Seal S.B applied at 1 to 1.5 gal./sq. OR Topcoat. MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoa& Membrane applied at 0.5 to 0.75 gal./sq. 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See fastening options above. Reviewed for Code Complian 1.0/03/17 NOA No.: 14-1030,01 MIAMMADECOUNTY Expiration Date: 11/04/1$ Approval Date: 05/04/17 Page 14 of 31 Membrane Type: Deck Type 1I::: Deck Description: System Type A(4)' BUR Wood, Insulated Min: 15/32" thick: or greater plywood or wood plank secured 6 in..o.c. at panel end and intermediate supports with 8d ring shank nails to, supports, spaced 24 in. o.c. at max. All insulation layers are adhered, to a mechanically attached anchor sheet. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: TOPCOAT FireOufm Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or (optional) VersaShield® Sold" Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: GAFGLAS' #75 Base Sheet, Tri-Plym.#75 Base Sheet; Ruberoide.20 Smooth or. . GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured:as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min..1-5/8 in. Option #1: diameter tin caps_are spaced 8 in. o.c. i.n the min: 4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum: Design Pressure: —45 psf. SeeGeneral Limitation #7) Fastening Miami=Dade County Approved min. 12 a annular ring. shank nails and min. .1-5/8 in. ty pp g . Option ##2: diameter tin caps are spaced 6 in. o.c. in' the:min 4 in. wide anchor sheet side laps: and 6 in. o.c. in the -field of the sheet in two staggered rows. (Maximum Design Pressure: -52.5 psf. See General Limitation #7) Fastening - Drill -Tee" #14 Fasteners and Drill-Tec"' 3 in. Standard Steel ,Plates, Drill-TecT"' Option #3: AccuTrac® Flat Plates or Dri11-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps: and 16 in. o.c. in the -field of the sheet in two staggered rows.. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill -Tee" 3 in. Standard Steel Plates, Drill=TecT" Option #4: AccuTrac® Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 im o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure. —60 psf. See General Limitation #7) Fastening Drill-TecT" #14 Fasteners and Drill -Tee'" 3 in. Standard Steel Plates, Drill-TecT"' Option #5: AccuTrac' Flat Plates or Drill-TecT" 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor sheet side laps and 8 in. o.c. in the field.of the sheet in three staggered rows. (Maximum Design Pressure: —82.5 psf. See General Limitation #7) Reviewed for Code Compliance 90/03/17 MIAMMADE COUNTY NOA No.: 14-1030:01 .. Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 15 of 31 One or more layers of any of the Insulation Layer Energy Guard T" Polyiso Insulation, Insulation, Ehergy.Guar&T RH Pol Minimum 1" thick insulations. Insulation Fasteners Fastener Density/ft' (Table.3) rgyGuardT"'Tapered Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuard"m RH'Tapered Polyiso Insulation - N/A N/A Note:.: All insulation shall be adhered in a full mopping of approved hot asphalt within.the EVT range and at a to Roofing Application Standard RAS 117 for insulation: attachment. rate of 20=401bs./100 W. Please refer Base Sheet: GAFGLAS® Stratavent® Perforated Venting Base Sheet is laid.dry over the insulation. Ply Sheet: ' When optional cap sheet is present: Two or more plies of GAFGLAS° Ply 4, Tri-Ply® Ply 4, GAFGLAS® Flex Ply 6 adhered in a full 'iiiopping of hot. asphalt applied at 20-40 lbs./sq. installed per :manufacturer's installation instructions. When op ional cap sheet is not present: Three or inore plies of GAFGLAS® Ply 4, Tri=Ply° Ply 4; GAF.GLAS® Flex Ply 6 adhered in a full mopping of hot asphalt applied_ at 20-40 lbs./sq. installed per manufdcluter7s installation instructions. Cap Sheet (OptIional): GAFGL Sm Mineral Surfaced Cap Sheet,. Tri-Ply® BUR Granule Cap Sheet or GAFGLASo Energy.Cap'" Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 40 lbs./sq: installed per manufacturer's installation. instructions. Surfacing: Optiona on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's application instructions. All coatings must be listed within.a current NOA. 1. Gravel o slag applied at400 lbs./sq. and 300 lbs./sq. respectively mi a flood coat of approve asphalt at 60 lbs./sq. 2. Topcoat Membrane or Topcoat" Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat.MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat Membrane applied at 0.5 to 0.75 gal./sq: 3. Aluminum Fiber Roof Coating. Maximum Design Pressure: See faste ing options above. Reviewed for Code Comp[ian 10103/17 MIAMI-DADE COUNTY NOA No.: 14-1030.01 Expiration Date: 11/04/18 Approval Date: OS/04/17 Page 16 of 31 Membrane Type: BUR Deck Type 11: Wood, Insulated Deck Description: 19/32" thick or greater or greater plywood or wood plank secured 6 in: o:c: at panel end... and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c: at max. System Type A(5): All insulationlayers are adhered, to a mechanically attached anchor sheet.: Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. Fire Barrier: FireOuc Fire Barrier Coating, VersaShield® Fire:Resistant Slip Sheet or VersaShield® (optional) Solo'" Fire -Resistant Slip Sheet. Anchor sheet: GAFGLASO #75 Base Sheet or Tri-Ply'#15 Base Sheet is secured as described below with Dade County Approved min. 12 ga. galvanized ring shank nails and 32 ga., 1-5/8 in. diameter tin tabs. Fastening: Nails and tabs are spaced 8 in. o.c. in the 4 in. wide side lap and 8 in. o.c. in:two staggered rows in the field of the sheet. One or more layers of any of the following insulations. Base Insulation Layer Insulation Fasteners -Fastener (Table 3) . ..Density/ftz EnergyGuardT" Polyiso Insulation, EnergyGuardT" Tapered Polyiso_ Insulation, EnergyGuardT" RH Polyiso: Insulation, EnergyGuard TM RH Tapered Polyiso Insulation Minimum 1" thick N/A 'N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 StructodeV High Density Fiberboard Roof Insulation, Securock® Gypsum -Fiber Roof Board Minimum %Z" thick N/A N/A . Note: All insulation shall be adhered in a full mopping: of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./1.00 ft2. Please refer to Roofing Application Standard RAS,117 for insulation; attachment. Base Ply: Two or more plies of GAFGLAS® F1exPly'" 6 adhered with hot asphalt applied at 20-25 lbs./sq. Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet adhered with hot asphalt applied: at.20-25 lbs./sq. Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer's. application instructions. All coatings must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. pcoat® Me brane or Topcoat' Surface Seal SB applied at 1 to 1.5 gal./sq. Reviews for Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) -followed by (`��p Comn��Cll I C a brane applied at 0.5 to 0:75 gal:/sq. Max Vin't'DZ3i'gn N..d.. Pres ure: 1.0/03/t?2.5 psf:.(Se General Limitation #7) NOA No.: 14-1030,01 MIAMMARECOUNTY Expiration Date: 1.1/04/18 • • Approval Date: 05/04/17 fags -17 of 31 Membrane Type: Deck Type 1I: Deck Description: BUR Wood, 19/32" or grea er plywood or wood plank secured 6. in. o.c. at panel end -and intermediate supports with ,d ring shank nails to supports spaced 24 in. o.c. at max. System Type B: Base layer of insulation is mechanically attached to roof deck. Any subsequent layers are then adhered to base layer of insulation. Membrane is subsequently fully adhered to insulation. All General and System Limitations shall apply. One or more layers of any of the folloyving insulations. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardT" Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuardT" RA Polyiso Insulation Minimum 1.3" thick 1, 2, 3, 4, 5, 6, 7; 8 1:3 ft2 EnergyGuardT" RN Polyiso Insulation, EnergyGuardT" RH Polyiso Insulation Minimum 1.4" .thick 1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz EnergyGuardT" RA Composite Polyiso Insulation Minimum 1.5 thick 1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz EnergyGuardT" Perlite Roof Insulation Minimum'%4" thick 1, 2, 3, 5, 6, 7,-8 1:2 :ft2 StructodeV High Density Fiberboard Minimum 1" thick 1, 2, 3, 5, 6, 7,8 1:4 ft2 Note: Base layer shall be mechanically attached with fasteners and density described. Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening details). GAF requires either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet laid dry or a layer of EnergyGuardT" Perlite Rool nsulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Any of the insulations options listed for Base Layer above. N/A N/A DensDecV Prime Roof Board, Str Ictodek® High Density Fiberboard, EnergyGuardT" Perlite Recover Board Minimum '/Z" thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved: asphalt within the EVT range and at a rate of 20-40 lbs./100 ftZ installed per manufacturer's installation instructions. Please refer to Roofing Application Standard RAS 117 for Insulation attachment., Composite insulation boards used as a top layer shall be installed with the polyisocyanut iate face down. Reviewed for Code Compliance 1-0/03/ 17 NOA No.: 14-1030;01 HIAMMADE COUNTY Expiration Date: 11/04/18 • • gug Ij Approval Date: 05/04/17 Page 18 of 31 Base Sheet: (Optional) Install one ply -of GAFGLAS® #75 Base Sheet, Tri-Ply® #75 Base Sheet, GAFGLAS® #80: Ultima" Base Sheet, GAFGLAS® Ply. 4, Tri=Ply® Ply 4, GAFGLAS® FlexPly " 6, Ruberoid® Mop. Smooth, Ruberoid® Mop Smooth 1.5., Ruberoid® Mop Plus Smooth or Ruberoid® 20 Smooth directly over the top layer of insulation. Adhere .with any approved:: :. ... . .... mopping asphalt applied within the EVT range and at a rate of 2040 lbs:/sq. installed per inanufacturer.':s installation instructions (See General Limitation #4). OR GAFGLAS® Stratavent':Perforated Venting Base. Sheet loose -laid dry (not for use with perlite wood fiber or composite polyiso top layer insulation). Ply Sheet: Two or more plies of GAFGLAS® Ply 4, Tri-.Ply® Ply 4, GAFGLASO FlexPlyT" 6 or GAFGLAS® #80. Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the EVT:range and at a rate of 2040 lbs./sq. installed per manufacturer's installation instructions: Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet,-Tri-Ply® BUR Granule -Cap Sheet or GAFGLAS® EnergyCapT°' Mineral Surfaced Cap Sheet adhered in a full mopping of approved. asphalt applied within, the EVT range and at a rate of 207-40 lbs./sq. installed per . - manufacturer's installation instructions. Surfacing: Optional on granular surfaced membranes; required_ for smooth membranes: Chosen components must be applied according to manufacturer's application: instructions. All coatings must be listed 'within a current NOA. . 1. Gravel or slag: applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved . asphalt at 6.01bs./sq. 2. Topcoat® Membrane or Topcoat° Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer). followed by Topcoat® Membrane applied at 0.5. to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: -45 psf. (See General Limitation #7) Reviewed for Code Compliance 10l03/17 MIAMf DADE COUNTY NOA No.: 14-1030AI Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 19 of 31 Membrane Type: BUR Deck Type 1I: Wood, Deck Description: 19/32" or supports N System Type C(1): All layers. fully adhe All General and System Limitation One or more layers of any of the folic Base Insulation Layer EnergyGuardT" RN Polyiso Insula Insulation, EnergyGuardT" RA Po: Minimum 1.3" thick EnergyGuard" Polyiso Insulation Minimum 1.4" thick EnergyGuardT RA Composite Po. Minimum 1.5" thick EnergyGuardT" Perlite Recover Bi Minimum'/4" thick Structodek® High Density Fiber B Minimum 1" thick Note: All layers shall be simultanf panels listed are minimum sizes al increased maintaining the same fa insulation attachment. GAF requi laid dry or a layer of EnergyGuar polyisocyanurate applications. Top Insulation Layer EnergyGuardT" Polyiso Insulation, Insulation Minimum 1.3" thick EnergyGuardT" RN Polyiso Insulal Minimum 1.4" thick 'um 1: ktkiewed yGuard'" Peril 6Foof It ium 3/" thick II II um 1" MIAMI-DADE COUNTY reater plywood or wood plank secured 6 in. o.c. at panel end and intermediate th 8d ring shank nails to supports spaced 24 in. o.c. at max. f insulation are mechanically attached to roof deck. Membrane is subsequently :d to insulation. shall apply. ring insulations. Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuardT Polyiso Insulation, EnergyGuardT" Ultra Polyiso Insulation, EnergyGuardT" RH Polyiso Insulation N/A N/A Insulation N/A N/A N/A N/A N/A N/A N/A N/A sly fastened; see top layer below for fasteners and density. Insulation dimensions; if larger panels are used, the number of fasteners shall be zer density. Please refer to Roofing Application Standard RAS 117 for either a ply of GAFGLAS® Stratavent® Perforated Venting Base Sheet Perlite Roof Insulation or wood fiber overlay board on all Insulation Fasteners Fastener (Table 3) Density/ft2 ergyGuardT" Ultra Polyiso Insulation, EnergyGuard" RA Polyiso 1, 2, 3, 4, 5, 6, 7,8 1:3 ft' EnergyGuardT" RH Polyiso Insulation 1, 2, 3, 4, 5, 6, 7, 8 1:3 ftz Insulation 1 1, 2, 3, 5, 6, 7,8 1:3 ftz 1, 2, 3, 4, 5, 6, 7, 8 1:2 ft2 112, 3, 5, 6, 7, 8 1:4 ftz NOA No.: 14-1030;01 Expiration Date: 11/04/18 Approval Date: 05/04/17 Page 20 of 31 Base Sheet: .......... (Optional) Install one ply ofGAFGLAS® #75 Base Sheet, Tri-Ply° #75 Base Sheet, GAFGLASo #80 UltimaT" Base Sheet; GAFGLASO Ply 4; Tri-Ply° Ply 4, GAFGLAS® FlexPly"" 6. Ruberoid® Mop Smooth; Ruberoid° Mop Smooth 1.5, Ruberoida Mop_ Plus Smooth:or Ruberoid® 20 Smooth directly over. the top layer of insulation. Adhere with any.. approved mopping asphalt applied within. the EVT range and at a rate of 20740 lbs./sq. installed per:manufacturer's installation instructions. OR GAFGLAS® Stratavento :Perforated Venting Base Sheet is loose laid dry (not for use with ) .. -wood fiber,perlite or com osite Poi isoto layer insulation Ply Sheet:. ..When optional base sheet and/or cap sheet is present: Two or fore plies of GAFGLAS® Ply 4, Tri Ply® Ply 4, GAFGLAS® Flex Ply 6, GAFGLAS® #80 UltimaT" Base Sheet adhered in. a full mopping of hot asphalt applied at:20-40 lbs./sq. installed per. manufacturer's installation instructions. When optional base sheet. and/or cap sheet is not present: Three or more plies. of GAFGLASO. Ply 4; Tri-Ply® Ply: 4,. GAFGLAS° Flex: Ply 6; GAFGLAS® #80 UltimaT" Base Sheet adhered in a full mopping of hot asphalt: applied at 20- 40 _lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One_ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-Ply® BUR. Granule Cap Sheet or GAFGLAS® EnergyCap.'" Mineral Surfaced Cap Sheet adhered in a- full mopping of approved. asphalt appliedwithin the EVT range and at a rate of 20-40- lbs./sq. installed -per manufacturer's installation. instructions. Surfacing: Optional on granular surfaced: membranes; required for smooth. membranes. Chosen components must be applied according to; :manufacturer's application instructions. All. coatings must be listed within a current NOA. 1. Gravel or slag applied at 400 lbs:/sq. and 300 lbs./sq. respectively in a flood .coat of approved Asphalt at .60' lbs./sq. - 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied, at 0.5 to 0.75 gal./sq.(to be used as a -primer) followed by Topcoat° Membrane applied at 0.5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum. Design Pressure: 45 psf: (See.General Limitation.#7) Reviewed for Code Compliance 10/03/17 MIAMMADE COUNTY NOA No.: 14-10301 Expiration Date; 11/04/18 Approval Date: 05/04/17 Page 21 of 31 Membrane Type: BUR Deck Type 1I: Wood,1 Deck Description: 19/32" c and inte System Type C(2): All laye All General and System Limitatia Fire Barrier: Fire0i (optional) Solo," One or more layers of any of the fo Base Insulation Layer (Optional) EnergyGuardT. Polyiso Insulation_ , Minimum 1" thick greater thick or greater plywood or wood plank secured 6 in. o.c. at panel end nediate supports with 8d.ring shank nails to supports spaced 24 in. o.c. at max. of insulation are me-chanically.attached to roof deck. Membrane is itly fully adhered to insulation. Shall apply. Fire Barrier Coating, VersaShield' Fire -Resistant Slip Sheet or VersaShield® •e-Resistant Slip Sheet. insulations. Insulation Fasteners Fastener (Table 3) Density/ft' RA Polyiso Insulation, .EnergyGuardTM RN Polyiso Insulation N/A N/A Note: All layers shall .be simultaneously fastened; see to layer below for fasteners and density. Insulation panels listed are minimum sizes anil' dimensions; if larger panels are used, the number of fasteners. shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. GAF requires either a ply of GAFGLAS® Stratavent° Perforated Venting Base Sheet laid dry' or a layer of EnergyGuard"' Perlite Roof Insulation or wood fiber overlay board on all polyisocyanurate applications. Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft' SECUROCK® Gypsum -Fiber Rool Board Minimum '/4" thick 2,8 1:1.18 fe Base Ply: Two or more plies of GAFGLAS® F1exP1yTM 6 adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions. Cap Ply: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAV EnergyCapT"' Mineral Surfaced Cap Sheet adhered with hot asphalt applied at 20-25 lbs./sq. installed per manufacturer's installation instructions Surfacing: Option) 1 on granular surfaced membranes; required for smooth membranes. chose components must be.applied according to manufacturer's application instructions. All coatings must be listed within a current NOA. 1. Gravel pr slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoa ®-Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. Review pcoalt° MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by for Topcoat' M.ei ibrane applied.at 0.5 to 0.75 gal./sq. RUN in m Roof CoatingMax g InCOrftpfiftti e Pres ure: 1.0/03/ t7o pl. (See eneral Limitation #7) NOA No.: 14-1030AI MIAMI-DADS CO. uNn Expiration Date: 11/04/i8 Approval Date:- 05/04/17 Page 22 of 31 Membrane. Type: BUR Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or-wood.plank secured.6 in.. o.c. at panel end and.intermediate supports with 8d ring shank nails to supports: spaced 24 in. o,c., at max. System Type D: All 'insulation is loose laid with preliminary attachment to roof deck. Anchor sheet is subsequently mechanically fastened through insulation to the roof deck. All General and System Limitations shall apply. One or more layers .of.any of the following. insulations. Insulation Layer- Insulation Fasteners Fastener (Table 3) Density/ft' EnergyGuard'" Polyiso Insulation, EnergyGuard'" Ultra Polyiso Insulation; EnergyGuard'" RA Polyiso Insulation Minimum 1:3" thick N/A N/A StructodeV High. Density Fiber Board Minimum 1" thick N/A N/A Note: Insulation shall have. preliminary attachment, prior to the installation of the base sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft:; and four fasteners for any insulation board -having no dimension greater than '8 ft. All layers of insulation, optional thermal barrier (when present) and base sheet shall be simultaneously fastened: See base sheet below for fasteners and density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Fire Barrier: FireOut" Fire -Barrier Coating, VersaShield®Fire Resistant Roof Deck Protection, (optional) VersaShieldl .Solo'" Fire -Resistant Slip. Sheet, DensDecke Roof Board, Securock"Glass- Mat Roof Board or Securock'" Gypsum Fiber Roof Board. Base Sheet: Install one ply of GAFGLAS® #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS' #80 Ultima Base Sheet, GAFGLAS° Stratavent® Nailable Venting Base Sheet or Ruberoid® 20 Smooth applied over the loose laid insulation with 2" side laps mechanically fastened as described below; Fastening Drill-Tec' #12 Fastener or Drill=Tec'M #14 Fastener and Drill-Tec'" 3" Steel Plate, Drill - Option #1: Tee 3 in. Ribbed Galvalume Plate (Flat), Drill -Tech' AccuTrac® Flat Plate or Drill-Tec'" AccuTracm Recessed Plate is installed through the base sheet and insulation in 3 rows 12" o.c. One row is in the 2" side lap. The other rows are equally spaced approximately 12" o.c. in the field of the sheet. (Maximum Design Pressure —45 psf. See General Limitation #7) Fastening Drill=Tec'" #12 Fastener or Drill-Tec'" #14 Fastener and Drill -Tee'" 3" Steel Plate, Drill= Option #2: Tee 3 in. Ribbed Galvalume Plate (Flat), Drill-Tec" AccuTrac® Flat Plate or Drill-Tec'" AccuTracm Recessed Plate is installed through the base sheet and insulation in 4 rows 8" o:c. One row is in the 2" side lap. The other 3 rows are equally spaced approximately 9" o.c. in the field of the sheet. (Maximum Design Pressure —75 psf.. See General Limitation #7) Fast . ning GLAS® #8 Ultima'°' Base Sheet, Ruberoid® 20 Smooth, Ruberoid® Mop Smooth Reviev Opt' DR #3: attached to deck with approved annular ring shank nails with a minimum embedment of 1" for into the wood su strate and inverted Y' steel plate at a.fastener spacing of 9" o.c. at the 4" M o r ws staggered with a fastener spacing of 9" o.c. in the center of the - Code CO rane. Not . or use with DensDeck or Securock Fire Bar-rier 10/03 iimum Desi gn Pressure -60 psf See General Limitation #7) NOA No.: 14-10301 M1AMMADE couNnr Expiration Date: 1.1/04/18 Approval Date: 05/04/17 Page 23 of 31 Fastening (Continued) Drill-TecT i #12 Fastener or Drill-Tee"#14 Fastener and Drill-TeeT" 3" Steel Plate, Drill - Option #4: Tee 3 in. Ribbed Galvalume Plate (Flat),; Drill=TecT" AccuTracm Flat Plate or Drill=TecT` AccuTrac Recessed Plate in 4 rows-12" o.c. One row is in the 2" side lap. The other rows are equall� spaced approximately 9" o.c. in the field of the sheet. (Maximu � Z Design Pressure —60 psf. See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® Ply 4; Tri-Ply® Ply 4, GAFGLAS® F1e. y m 6 or GAFGLA$® #80 Ultima Base Sheet adhered in a full mopping of approved asphalt applied within the IEVT range and at a rate of 20-40 lbs./sq. installed per manufacturer's installation Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply BUR Granule Cap Sheet or GAFGLAS® EnergyCapT"" Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within -the EVT range and at a rate of 20-40 lbs./sq. installed tier manufacturer's installation instructions. Surfacing: Optional Ion granular surfaced membranes; required for smooth membranes. Chosen components must. be applied according to manufacturer's application instructions. All coati fgs must be listed within a current NOA. 1. Gravel or slag applied at 4001bs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to, be used as a primer) followed by Topcoat® Membrane applied at 0..5 to 0.75 gal./sq. 3. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Faste iing Options Reviewed for Code Compliance 10/03/17 NOA No.: 14-1030:01 MIAMFDADEcouNTY Expiration Date: 11/04/18 Approval Date: 05/64/17 Page 24 of 31 Membrane Type: BUR Deck Type 1: Wood, Non=insulated Deck: Description: 19/32" or greater plywood -or wood plank.decks secured 6 in.: o.c.. at panel end and intermediate supports with 8d ring shank -nails to supports. spaced 24 in. o.c. at max. System Type E(1): Anchor sheetmechanically attached to.roof deck. All General and System Limitations shall apply. Fire Barrier: Topcoat® FireOut" Fire Barrier Coating, VersaShield®Fire Resistant Roof Deck (optional) Protection, VersaShield® SoIoTM Fire=Resistant. Slip Sheet installed per manufacturer's _ installation instructions. Base sheet: GAFGLAS®#80 UltimaT' Base Sheet, Stratavent® Nailable Venting Base Sheet, Ruberoid® 20 Smooth, Ruberoid® SBS Heat -Weld" Smooth or Ruberoid® SBS Heat -Weld"' 25 base sheet mechanically, fastened to deck as described below; Fastening GAFGLA'Flex ply TM 6, GAFGLAS® #75 Base She et;_Tri-Ply° #75 Base Sheet or any of Option #1: the above anchor sheets attached to deck with approved annular ring shank nails and tin caps at a fastener spacing 0f9" o.c. at the 4" lap staggered and in two rows 9" o.c, in the field. (Maximum -Design Pressure .-52.5.psf:. See General Limitation #7) Fastening GAFGLAS® #80 UltimaTM Base Sheet, Ruberoid® 20 Smooth or Ruberoid® Mop Smooth Option #2: attached to .deck with approved 1 �'/a" annular ring shank nails and inverted 3" steel plate at a fastener spacing of 9" o.c. at the 4" lap and in two .rows:staggered with :a fastener spacing of, 9" o.c. in the center of the membrane. (Maximum. Design Pressure —60 psf... See General Limitation #7) Ply Sheet: One or more plies of GAFGLAS® Ply 4, Tri-Ply® Ply 4. or GAFGLAS® #80 Ultima Base Sheet. adhered in a full. mopping of approved asphalt applied within the EVT range -and at a rate of.20-40 lbs./sq:. installed per manufacturer's installation instructions. Cap Sheet: (Optional) One ply of GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap, Sheet or GAFGLAS,EnergyCap" Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range, and at a rate of 20-40 lbs./sq. installed per: manufacturer's installation instructions.. Surfacing: Optional on granular surfaced membranes;: required for smooth membranes. Chosen components must be.applied according.to manufacturer's application instructions. All coatings must be listed within a current NOA. . 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively ina flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Revi ewoat® Meml for Fiber Aluminun tPNgComb1, nce 10/03�1 �astemng C MIAMI-DADS COUNTY isapplied at 0.5 to 0.75 gal: sq.(to be used as a pnmer) followed by ane applied at 0.5 to. 0.75 gal./sq. Roof Coating.- ..... .. NOA' No.: 14-1030;01 Expiration Date: 1.1/04/18 Approval Date: 05/04/17 Page 25 of 31 Membrane Type:, BUR Deck Type 1: Wood, Deck: bescription: 19/32" System Type E(2): Anchor All General and System Limitath Fire Barrier: (optional) Anchor sheet: Ply Sheet: Cap Sheet: Surfacing.: Maximum Design Pressure: 111 r�greater plywood or wood plank decks secured 6 in. _o.c. at panel end and iate supports with 8d ring shank nails to supports. spaced 24 in., o.c. at max. I eet mechanically attached to roof deck. . 's shall apply. PP y ' FireOutTM Fire Barrier Coating, VersaShielde Fire Resistant Roof Deck VersaShield° S016TM Fire -Resistant Slip Sheet installed per manufacturer's �n instructions. GAFGLAS® #80 Ultima Base Sheet mechanically attached with Miami -Dade County Approved min. 1'/4 long, 12-ga., annular ring shank nails and 1-5/8" diameter tin caps spaced 7'� o.c. in the min 4" wide side laps and in 3 staggered rows in the field of the sheet. Two or }ore plies of GAFGLAS® Ply 4, Tri-Ply° Ply 4, GAFGLAS® F1exPly"° 6 adhered to the base Sheet in fullmopping of approved asphalt applied within the EVT range and at a rate of 2d-40 lbs./sq. installed per manufacturer's installation instructions. One ply of GAFGLASO Mineral Surfaced Cap Sheet, Tri-P1yO BUR Granule Cap Sheet or GAFGL SO EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. installed per manufac rei's installation instructions. Optiona�'on granular surfaced membranes; required for smooth membranes. Chosen components must be applied according to manufacturer'sapplication instructions. All coatings must be listed within a current NOA. 1. Gravel orb slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat" Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR . Topcoat MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat Membrane applied at 0.5 to 0.75 gal./sq. -82.5 Reviewed for Code Coft Tian 10/03/17 . (See General Limitation #7) NOA No.: 14-1030.01 MIAMI-DADECQUNTIf Expiration Date: 11/04/19 Approval Date: 05164/17 Page 26 of 31 Membrane Type: BUR Deck Type lI:: = Wood, .Non Insulated Deck Description: Min: 15/32" thick.or.greater. plywood or wood plank secured 6 in..o.c. at panel end and intermediate supports with 8d ring shank nails to supports spaced 24 in. o.c.,at.max, System Type E(3):: Anchor sheet mechanically attached to roof deck. All General and System Limitations shall apply: Fire Barrier: TOPCOAT Fire OutTM Fire Barrier Coating, VersaShield® Fire -Resistant Slip Sheet or (optional) VersaShieldO S0loTM Fire -Resistant Slip Sheet installed per manufacturer's installation instructions. Anchor sheet: : GAFGLAS® #75 Base Sheet,. Tri-Ply® #75 Base Sheet, Ruberoide 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base Sheet is secured as.described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5%8: in.. Option #1: diameter tin caps are spaced.8 in. (i.e. in the min. .4 in. wide anchor sheet side laps and 8 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —45 psf. See General Limitation #7) . Fastening Miami -Dade County Approved. mina 12 ga. annular ring. shank nails and mire. l-5/8 in. Option #2: diameter tin caps .are spaced:6 :in. -o.c. in the min :4 in. wide anchor sheet: sidelaps. and 6 in. o.c. in the field of the sheet in two staggered rows. (Maximum Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill -Tee' #14fasteners and Drill-TecT"' 3 in. Standard.Steel Plates, Dr 1l-TecT" Option #3: AccuTrac® Flat Plates or Drill-TecT" 3 in.. Ribbed Galvalume Plate (Flat) are spaced:16 in. o.c. in the min. 4 in. wide .anchor sheet side laps. and 16in. o.c. in the field .of the sheet in two staggered rows. (Maximum Design Pressure: -52.5 psf. See General Limitation #7) Fastening TM Drill-Tec' #14 Fasteners and Drill -Teel" 3 in. Standard Steel Plates, Drill-TeC Option #4: AccuTrac® Flat Plates or Drill-TecT 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in._ wide anchor sheet side laps and 12 in. o.c. in the field of;the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening . PrillJecTM #14 Fasteners and Drill TecT'" 3 in. Standard Steel Plates, DrillJecTM Option 95. AccuTrac® Flat Plates .or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min.:4 in. wide anchor sheet side laps and 8 in. o.c. in the field:of:the sheet in three staggered rows. .(Maximum Design Pressure: —97.5 psf. See General Limitation #7) Ply Sheet: When optional cap sheet is present: Two or more plies of GAFGLAS® Ply 4, Tri-Plye Ply 4, GAFGLAS® Flex Ply 6 adhered .LULL L`FF ng of hot asphalt applied at 20-401bs./sq. installed per manufacturer's Reviewed tallation instructions. for When optiona cap sheet is not present: or Code CompWr plies ofGAFGLASO Ply 4, Tri-Ply° Ply 4, GAF.GLAS® Flex Ply6 . a 11 mopping. of hot asphalt applied at 20-401bsJsq:.installed per 1.0/03/1ganufacturer' installation instructions. NOA No.: 14-1030.01 MIAMI-DADE COUNTY Expiration -Date: 1.1/04/18 • • Approval Date: 05/04/17 Page 27 of 31 Cap Sheet: (Optional) GAFGLAS° Mineral Surfaced Cap Sheet, Tri-Ply' BUR Granule Cap Sheet or GAFGLAS EnergyCapT' Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt (applied at 20 — 40 lbs./sq. installed per manufacturer's installation instructions. Surfacing: Optional on granular surfaced -membranes; required for smooth membranes. Chosen components must be applied, according to manufacturer's application instructions. All coatings must be'listed within -a current NOA. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq. respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat° Membrane or Topcoat® Surface Seal S:B applied at 1 to 1.5 gal./sq. OR Topcoat° MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer). followed by Topcoat° Membrane applied at 0.5 to 0.75 gal./sq. I. Fiber Aluminum Roof Coating. Maximum Design Pressure: See Fa tening Above. Reviewed for :-Code Compliance 1.0/03/17 NOA No.: 14-1030:01 MIAMFDADECOUNTr Expiration Date: 11/04/19 • • Approval Datec 05/04/17 Page 28 of 31 e Membrane Type: BUR Deck Type 1I: Wood', Non Insulated Deck Description: Min. 15/32" thick or greater plywood or wood plank secured 6 in. o.c. at panel end and intermediate supports with ,8d ring shank nails to supports spaced 24 in. ox. at max. System Type E(4): Anchor sheet.mechanically attached to roof deck. A11 General and SY stem Limitations sh 11 1 a aPP. Y• Fire Barrier: TOPCOAT FireOutTM. Fire Barrier Coating, Versa Shield® Fire -Resistant Slip Sheet. . (optional) VersaShield® SoloT"' Fire -Resistant Slip Sheet, installed perm' ufacturer's installation instructions. Anchor sheet: GAFGLAS® #75 Base Sheet; Tri-Ply® #75 Base Sheet, Ruberoid® 20 Smooth or GAFGLAS® Stratavent® Venting Nailable Base'Sheet is secured as described below. Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails and min. 1-5/8 in. diameter Option #1: tin :caps are spaced 8, in. o.c. in the min. 4 in, wide_ anchor sheet side laps and 8 in. o.c::in .the field of the sheet: in two staggered rows: (Maximum Design Pressure: —45 psf. See General Limitation #7) Fastening Miami -Dade County Approved min. 12 ga. annular ring shank nails. and min. 1-5/8 in. diameter Option #2: tin caps are spaced: 6 in. o.c. in the min 4 in. wide anchor sheet side laps and 6 in.-o.c. in the field of the sheet in two staggered rows. (Maximum -Design Pressure: —52.5 psf. See General Limitation #7) Fastening Drill-TecTM #1:4 Fasteners and Drill-TecTM 3 in. Standard Steel .Plates, Drill-TecTM AccuTrac® Option 93: Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 16 in. o.c. in the min. 4 in. wide anchor sheet side laps and 16 in. o.c: in the field of the sheet in two staggered rows. (Maximum Design Pressure: =52.5 psf. See General Limitation #7) Fastening Drill-TecTM #14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates, Drill-Tec M AccuTrac® Option ##4: Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 12 in. o.c. in the min 4 in. wide anchor sheet side laps and 12 in. o.c: in the field of the sheet in two staggered rows. (Maximum Design Pressure: —60 psf. See General Limitation #7) Fastening Drill=TecTM' #14 Fasteners and Drill-TecTM 3 in. Standard Steel Plates; Drill-TecTM Accu:Trae Option #5: Flat Plates or Drill-TecTM 3 in. Ribbed Galvalume Plate (Flat) are spaced 8 in. o.c. in the min. 4 in. wide anchor_ sheet side laps and 8 in. o.c. in the field of the sheet in three staggered rows. (Maximum Design Pressure: -97.5 psf. See General Limitation #7) Base Sheet: Ruberoid' 20 Smoothadhered in a full mopping of -hot asphalt applied at 20-4.0 lbs./sq. installed per manufacturer's installation instructions. Cap Sheet: GAFGLAS® Mineral Surfaced Cap Sheet, Tri-Ply® BUR Granule Cap Sheet or GAFGLAS EnergyCapTM Mineral Surfaced Cap Sheet adhered in a full mopping of hot asphalt applied at 20 — 401bs./sq. installed per manufacturer's installation instructions. Reviewed for Code Compliance 1.0/03/17 MIAMFDADE COUNTY NOA No.: 14-1030.01 Expiration Date: H/04/18 Approval Date: 05/64/17 Page 29 of 31 Surfacing: Optional on granular surfaced membranes; required for smooth membranes. Chosen components must be aippfied according to manufacturer's application instructions. All coatings must be listed within a curre.nt,NOA. 1. Gravel or slag applied at 400 lbs./sq. and 300 lbs./sq: respectively in a flood coat of approved asphalt at 60 lbs./sq. 2. Topcoat® Membrane or Topcoat® Surface Seal SB applied at 1 to 1.5 gal./sq. OR Topcoat® MB Plus applied at 0.5 to 0.75 gal./sq.(to be used as a primer) followed by Topcoat® Membrane applied at 0.5 to 0..75 gal./sq. 3. Aluminum FI 'ber Roof Coating. Maximum Design Pressure: See Fastening Above. Reviewed for Code Compliar 10/03/17 NOA No.: 14-1030:01 MIAMI-DADE COUNTY Expiration Date: 11/04/1$ • Approval Date: 05/04/17 Page 30 of 31