HomeMy WebLinkAboutEXISTING STRUCTURE 6-11-18zts =LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
.. TO DETERMINE IF MULTIPLE PLY. ..
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
_ -- p
— � -- _---- ----� o Span
S
r 30' Sp 'nor less ' Spreader Bar I
60 degrees
or less
Tag line 12 span -- Tag line qj— APprox M to —�
approx. 12 of Span.
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane is used. Truss must be set this way if crane is used.
Truss is an example, your truss may not match. Truss is an example, your truss may not match.
Insist crane operator sets truss this way. Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. A
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
�- - WARNING !
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
Hatch Legen
INDICATES
VOLUME
CEILING
LOAD
BEARING
AT 101-011
8O )- v
A Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
JUN 11 2018
Permitting Department
St. Lucie county, FL
a w„
k
�IrY �'4 �IYea4�i�i�iAICxI+fiRYx,ha�.+,
4 ,
ARCMITEGTu1L
REVIEW
�{ AP ROVED
APPfROVFD AS NOTED
.0 NOTekPROVP
1
DATE
J �J
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
letermining successful fabrication of the mosses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ndersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
hall have three (3) business days in which to begin repairs required, or to substitute other mosses, at Chambers option.
fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of 'BCSI' summary sheet by TPI 8 WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
responsible for dump delivery only. The buyer is responsible for additional delivery expenses 'd Chambers Truss has i
o redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
,esponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour !
as for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
voice will be made on delivery and paid whin terms of net on delivery. Invoice may be made at scheduled date of j
'elivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
'easonable attorneys fee for collections in event of payment not timely made. 1-12 % per month service charge will be
doled for all sums not paid within terms.
8. Signature or initials anywhere on this sheet oonstilutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
yment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
ndersigned agrees to pay such indebtedness including attorneys fees, 'd default in payment for material be made by the
ecipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
erein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibifities are per `"`National Standard And Recommended Guidelines On Responsibilities For
onstruction Using Metal Plate Connected Wood Trusses ANSIlrPIMWTCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached. f
I
DATED
IGNED
OR TITLE
�I
A spreader bar may be required per "BCSI" to prevent injury & damage.
i
Multiple ply trusses must be fastened together per engineering before they are j
set, failure to do so can result in roof collapse.
Temporary and ® ' po ry permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set and square
Do not set bunks or stack of plywood, roofing material or any other j
j� concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES !
CHAMBERS TRUSS INC
3105 can er venue
Fort Pierce, Florida 34982-6423
800-551.5932
Fort Pierce M-465.2012 Fax 772-465-8711
Vero Beach 772-569.2012 Stuart 772-286.3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
I
ITEK VERSION 7.4.1.431 LOADINGIDESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
DESIGN CRITERIA
County ST. LUCIE
Building Department ST. LUCIE COUNTY
Wind Design Criteria ASCE 2010
Wind Design Method MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material TILE I
Loading in PSF Roof R.D.L. Floor -
Top Chord Live 20 0
Top Chord Dead 15 4.2 0
Bottom Chord Live *10-Non Conccurent 0
Bottom Chord Dead 10 3 0
Total Load 55 7.2 0
Duration Factor 1.25 0
Wind Speed 170mph •;
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 180600
Building Type Enclosed I
Building Category If: Non Restrictive
Exposure Category C>Open Terrain with scattered obstructions
Miles from Ocean 5
Conforms to Florida Building Code 2014
R.D.L.=Restraining Dead Load C.B.=Continuous Bracing
I
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 74826
SCALE: 1/4" = 1I
16 total trusses, 4 unique designs
Designer: RLC Reviewed by: RLC
Date: 12/15/17
FOR
CHAD LAWSON
DESCRIPTION:
CALLEJO
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
74826
111 I (J )PY