DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND. CODE ADMINISTRATION DIVISION
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF AC + PTANCE (NOA) www.miamidade.2ov/economy
Value Metal Corp.
426 NW 9`s Avenue
Homestead, FL. 33030
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: VMC 1-1.5 Standing Seam Architectural Metal Roof System
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA No. 09-0430.02 and consists of pages 1 through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 13-0820.14
Expiration Date: 0S/21/18
Approval Date:10/03/13
WA
ROOFING SYSTEM APPROVAL:
Category
Roofing
Sub -Category:
Metal, Panels (Non -Structural)
Material:
Steel
Deck Type:
Wood
Maximum Design Pressure-136.75 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
1-1.5" Standing Seam Length: various TAS 125 Corrosion resistant, ASTM A653-97 grade C,
Architectural Roof Width: 16.5" galvanized steel, preformed, standing seam
Panel Height: 1.5" panels. Kynar 500 coated, pre -finished, metal
Thickness: 24 ga. panels.
Clip Length:120" TAS 125 Corrosion resistant, ASTM A653-97 grade C,
Width: 1.5" galvanized steel, preformed, coated, pre -
Height: 1-5/8" finished, continuous metal clips.
Thickness: 24 ga.
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS:
Test
Product Dimensions Specifications
Fire Barrier N/A Fire Barrier for Class `A' fire rating
#30 Felt N/A Saturated organic felt to be used as a nailed
underlayment
Bostik Chem -Calk N/A Polyurethane Adhesive Sealant
915 Polyurethane
Adhesive/Sealant
Fasteners #10 screws
MANUFACTURING LOCATION:
1. Homestead, FL
Corrosion resistant, pancake head screws
Product
Description
Generic
(with current NOA)
Generic
(with current NOA)
Bostik Ink.
(with current NOA)
Generic
NOA No.: 13-0820.14
Expiration Date: 08/21/18
Approval Date: 10/03/13
Page 2 of 6
rl
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Reno rt Date
Akzo Nobel Salt Spray
ASTM B 117
Akzo Nobel Accelerated Weathering
ASTM G 23
PRI Construction Materials VMC-004-02-01 TAS 100 06/06/08
Technologies
Hurricane Test Laboratory, LLC.
0484-0316-08
TAS 125
06/16/08
Hurricane Test Laboratory, LLC.
0484-0312-09
TAS 125
04/17/09
APPROVED
NOA No.: 13-0820.14
Expiration Date: 08/21/18
Approval Date: 10/03/13
Page 3 of 6
APPROVED ASSEMBLIES:
System A: 1 1/2" Standing Seam Mechanically Seamed Panel 16" Wide
Deck Type: Wood, Non -insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank.
Slope Range: 2:12 or greater
Maximum Uplift See Table A below.
Pressure:
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
1'/32") the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be an ASTM D 226 Type II installed with a minimum 4" side -
lap and 6" end -laps. Underlayment shall be fastened with corrosion resistant tin -caps and 12
gauge 1 '/4" annular ring -shank nails, spaced 6" o.c. at all laps and two staggered rows 12"
o.c. in the field of the roll. Or, any approved underlayment having a current NOA.
Fire Barrier: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with Value Metal Corporation's current published installation instructions.
Metal Panels and Install the "1-1.5" Standing Seam Panel" and accessories in compliance with the current
Accessories: published installation instructions and details in Value Metal Corporation's Installation
Manual. Flashings, penetrations, valley construction and other details shall be constructed in
compliance with Roofing Application Standard RAS 133.
1. Panels shall be installed with approved Continuous Panel Clips located at each panel
side lap spaced with two (2) 410 pancake head corrosion resistant screws of
sufficient length to penetrate through the sheathing a minimum 3/16 of an inch, 1-1/2"
apart, at a maximum spacing, listed in Table A below, parallel to roof slope.
2. Seal panels by place 1-1 /8" diameter bead of Bostik Chem -Calk 915 sealant on panel
end before placing adjacent panel.
3. Standing seams shall be mechanically seamed to a 900 degree seam, (single lock).
TABLE A
Maximum DESIGN PRESSURES
Roof Areas
Field
Perimeter and Corner'
Perimeter and Corner'
Maximum Design
Pressures
—84.25 psf
—114.25 psf
—136.75 psf
Maximum Fastener
Spacing
18" o.c.
12" o.c.
6" o.c.
1. Extrapolation shall not be allowed
NOA No.: 13-0820.14
MAMI-Dane coExpiration Date: 08/21/18
Approval Date: 10/03/13
Page 4of6
of
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
NOA No.: 13-0820.14
Expiration Date: 08/21/18
Approval Date: 10/03/13
Page 5 of 6
PROFILE DRAWING:
1-2 5" .375"
Before Seaming
4 /A11
90 degree
Seam
1-1/2" STANDING SEAM ARCAITECTURAL METAL ROOF SYSTEM
END OF THIS ACCEPTANCE