Loading...
HomeMy WebLinkAboutREVISION 11-11-18OFFICE USE ONLY: j�3Evwqk DATE FILED: By PERMIT # N o ajDo39 REVISION FEE: `- Snust Luc* ('G)ol RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 vp � �1ti0 a Fec� QC 0 t�'�VJ`�c Pe �j'0' APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION jv 1. LOCATION/SITE ADDRESS: 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: c / / letz 6111,43 3. 4. CONTRACTOR STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: /,,Oj 42 CITY: PHONE (DAYTIME): G /— 'U (00'70(0 ST. LUCIE COUNTY CERT. #. OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PRONE: 5. ARCHITECT/ENGINEER INFORMATION: NAME: _ ADDRESS: _ CITY: _ PHONE (DAYTIME): SLCCC: 9/23/09 Revised 04/26/2010 FAX: STATE: FAX: STATE: FAX: REVISION ZIP: ZIP: MV WP/GFI IJ-I. 00 MV 400A METER TRANSFER SWITCH FOR G N 200AMP r MAIN 15REA RI vP W VP EXIST SEDRM 2 P /i JS 9A SA 50" LN fl] V EXIST JS M- BEDRM 10'-0" GLG N wp/GFI SOFFIT LIGHTING TYPICAL A FLOOR ELECTRIC PLAN NORTH-, 1/4"=1'-0" 0'-0" GLG qp EXISTING 1=A" II L 1� RM so LLyJ 50' • II'-m" GLG COVE LTG OVE LTG TAMPER RESISTANT REGEFTAGLES PER NEG 406-12 ff FI G RE4002.14 ARE REaUIRED IN DWELLING UNITS IN ALL AREAS AS SPECIFIED IN 2014 NEC, 210.52, ALL 125V, 15 $ 20 AMP RECEPTACLES ELECTRICAL RISER DIAGRAM 33/0 THH IN E 2" C. W/ 3-3/0 E 1-#6, THHN 400A 200 AMP ELECTRICFk PANEL IN METER VESTIBULE BY LAUNDRY L-2" NIPPLE FROM XFR SWITCH TO 200 AMP MAIN BREAKER 8 CIRCUIT FEED THROUGH PANEL W/ 3-3/0 @-#(b THHN UNDERGROUND SERVICE BY #4 THWN CU. GE.C. CONNECTED TO THE BLDG. FF IL STEEL AND EXTENDED TO 5/8" X 8' COPPER GIRD ROD. 5/8" X 6 GIRD ROD CONNECT TO BLDG. STEEL W/ FOOTER CLIP $ METALLIC COLD WATERADN GAS PIPES NEW LIVING RM ll'-O" GLG 11'-4" GLG WP/GFI GFI I I L0 \ w l t- I I1l.ICV GFI J NEW SLAND Gf Itc.� W/ U.G. I � NEW C0� ROLL L SHADE 10-4" CLG U.G. DISH/ DISP Ui WP/CFI CLG no C ROLL UP I V TO MS LIGHTS SHADE TYPICAL? 2,c / ., J5 = JAMB SWITCH 133" TO MS LIGHTS 20041 PANEL 72" 112" GAS �--� — PANEL E30ARD SGPEDULE BUS Amp Load Description Pole Trip # # Trlp Pole Load Description BUS Amp A/C #10, 3/4" 2 30 1 2 60 2 AHU 00KW HS) #6, 3/4" 10000 3 4 4500 WATER HEATER #1 #10, 3/4" 2 30 5 6 30 2 DRYER #10, 3/a' 5000 7 s woo RANGER W/ HOOD #8, 3/4' 2 50 5 10 20 1 WASHER #I2, 1j2" 1500 - - - II 12 20 1 I LAUNDRY RM (GFI) #12, 1/2" 1500 SMALL APPLIANCE (CFI) #12, I/2" 1 20 13 14 20 1 OFFICE (AFCI) #12,1/2" 1500 SMALL APPLIANCE (GFI) #12, I/2" 1 20 15 I6 20 1 BEDROOM #2 (AFCI) #12, I/2" 1200 DISHWASHER ((:FI) #12, I/2" 1 20 17 IS 20 1 I j MASTER BDRM (AFCI) #12, I/2" 700 DISPOSAL (GFI) #12,1/2" 1 20 IS 20 20 1 MASTER BATH (GFI) #12, 1/2" 1200 REFRIGERATOR #12, 1/2" 1 20 21 22 20 1 BATH #2 (GFI) #12, 2" 2500 IRRIGATION PUMP #10, 3/4" 1 30 1 23 24 20 1 SPARE EXT. LIGHTING #12, 11/2" 1 20 25 26 20 1 SPARE LIVING RM (AFCI) #12, 1/2" 1 20 27 26 20 1 EXT. RECEP. (WP/ GFI) #12,1/2" DINING RM (AFGI) #12, 1/2" 1 20 20 30 20 1 GENERAL RECP. (AFCI) #12, 1/2" SPARE #12, 1/2" 1 20 31 32 20 1 GENERAL LIGHTING #12, 1/2" SPACE 33 1 34 120 1 1 BATH #3 (GFI) #12, 1/2" SPACE 1 35 36 20 1 SPARE #12, 1/2" SPACE 37 38 SPACE SPACE 3S 40 SPACE SPACE 41 42 SPACE RATED VOLTAGE: ❑ 120/208 N VERIF0 ❑ 271/450 1 PHASE 3 WIRE POLES: 12 20 ❑ 30 42 RATED AMP50 100 150 0 200 225 D 400 MOUNT: SURFACE® FLUSH FULL NEUTRAL BUS 0 GROUND BUS ❑ BOLT -IN TYPE ® PLUG-IN TYPE FEED IS TO BE: BOTTOM ® TOP MAIN LUG ONLY MAIN CIRCUIT BREAKER AMPS All breakers must be rated to interrupt a Short Circuit I5C of 10,000 amps a9mmetrical (Series rated with main) ON ICATED GATE LOAD CA TIONS AREA UNDER A/C 2103 sgft General Load: General lighting VA ea 6,309 va 1 Range 8000 ' 8,000 1 Microwave' 1500 1,500 1 Disposal 700 700 1 Refrigerator 1200 1,200 1 Irrigation pump 2500 2,500 1 Washer 1500 1,500 1 Dishwasher 1200 1,200 1 Dryer 5000 5,000 2 small appliance circui 1500 3,000 1 Water Heater 4500 4,500 1 U.C. Wine 1000 1,000 Sub total General Load 36,409 First 10,000 @ 100% 10,000 Balance @ 40% 10,564 Total General Load 20,564 VA A/C load @ 100% Cooling Heating #1 10,000 Total A/Cload % 100% 10,000 Total load 20,564 + 10,000, 30,564 AMPS 127 ELECTRICAL 5"T'M5(:JLS VL DUPLEX RECEPTACLE AT 15" AFF. $ SWITCH SINGLE POLE S TELEPHONE AT IV' ArFI CUTLET . / \ / HI -HAT CL'G. MOUNTED ,�I 6\ DUPLEX RECEPTACLE FAULT WERRIPTE $3 SWC44 THREE WAY � FLUSH M fI OORLET /V,, VAPOR PROOF ,I{, B (III DUPLEX RECEPTACLE AT BASE $4 SWITCH FOUR WAY DSL V INTERJET, MODEM A CABLE IV' AFF. 11 N \ RECESSED WAL WASHER `+1'C DUPLX AT 9""EABVV.. CEPTACCOUNTERLE W R RHEOSTAT OS IN EAKCLG. R C WASHERCE98E WAL GF! W1 DUPLEX RECEPTACLE GROUND FAULT p SWITCH DIMMER S'`I' HARD WIRED SMOKE ALARM INCANDESCENT WALL MOUNTED LIGHT Ul DUPLEX RECEPTACLE TOP RrC. SUUTC14ED K SWITCH KEYED ® HARD WIRED CARBONMONOXIALADER1 DETEC70�/ D WALL SCONCE `w DUPLEX RECEPTACLE WATERPROOF ❑-I DISC. SWITCH DISCONNECT O HVAC TNER108TAT TRACK LIGHT �U0 DUPLEX RECEPTACLE CO UNDER UNTER SECURITY KEY PAD T H THERMOSTAT/ HUMIDISTA� F-1 FLUORESCENT LIGHT FIXTURE ® QUADPLEX RECEP7. AT 15" APE. 4. CONTROL PAD 0 FOR EA. DOOR) ® EXHAUST FAN PIER MOUNTED LIGHT FIXTURE /h W DEDICATED CIRCUIT 120V QP-40TO SWITCH GARAGE DOOR ' N'.OR BE'N"I EXHAUST FAN W/ LIGHT EMEf�rENCY LI 79 y� 1}}7 OUTLET FOR GARAGE DOOR OPENER -OD.5. DOOR BELL PADDLE F UU OR UUO IGHT �7 i\'N�^1 SECURITY, FL LIGHTS D ®M DIRECT WIRED MOTOR (o") 7 INTERCOM AT 60" AFF. �/ MS `���11 MOTION SENSOR LIGHTS ® 220 V. RECEPTACLE AT 24" AFF. ® INTERCOM BABE STATION INCANDESCENT GL'G. MOUNTED LIGHT ' CHANDLER O DUPLEX RECEPTACLE FLUSH IN FLOOR PRE -WIRED TELEVISION' GABLE SATELLITE JACK A.L.PANEL GLOBE LIGHT BREAKER [� O JUNCTION Sox I�..0 'c CHIME 50X LEY- KEYLESS FIXTUREO IGHT n FP41-. METER 8 DISC. GENERAL ELECTRICAL N I¢TES: I. ALL WORK SHALL BE DONE IN ACCORDANCE WITH BOTH LOCAL AND 2014 NATIONAL ELECTRICAL CODES. 2. ELECTRICAL CONTRACTOR SHALL VERIFY ELECTRICAL PLAN, RISER DIAGRAM, AND LOADS, AND NOTIFY THE GENERAL CONTRACTOR OF ANY ERRORS OR DISCREPANCIES PRIOR TO INSTALLATION. 3. ALL EQUIPMENT INSTALLED OUTSIDE OR EXPOSED TO WEATHER SHALL BE NEMA TYPE 3R 4. MINIMUM WIRE SIZE SHALL BE # 12 COPPER I S. ALL CONDUCTORS ARE TO BE COPPER, TYPE TµIHN, UNLESS OTHERWISE NOTED, 6. CONNECT GROUNDING ELECTRODE CONDUCTOR !TO 5/64, x 8' GROUND ROD ND NEAREST COPPER WATER LINE (COLD). 7. ALL 12OV. I PHASE 20A. BATHROOM, GARAGE, AND EXTERIOR RECEPTACLES, SHALL HAVE GROUND FAULT INTERRUPTER (GEL) PROTECTION WITH EXTERIOR RECEPTACLES of THE WATERPROOF TYPE. ELECTRICAL CONTRACTOR MAY INSTALL NDIVIDUAL (GEL) IN LIEU OF (GFI.) BREAKER WITH SEPARATE CIRCUI. 8. SWITCHES SHALL BE OF STANDARD GRADE OF °SILENT TYPE 48" A.FF. 9. RECEPTACLES SHALL BE IDA. AND 120V. OF THE GROUND TYPE I6" AFF. UNLESS OTHERWISE OPEGIFIED. 10. THE ELECTRICAL CONTRACTOR IS TO SIZE MOST BRANCH CIRCUITSt A MAXIMUM VOLTAGE DROP OF 3% IS PERMITTE . 11. THE ELECTRICAL CONTRACTOR I5 TO ARRANGE FOR TELEPHONE SERVICE AND TELEPHONE WIRING. GOORDINATE',WITI4 THE TELEPHONE COMPANY UNLESS OTHERWISE SPECIFIED. 12, BRANCH CIRCUITS SHALL BE IN THIN WALL CONDUIT OR APPROVED EQUAL 13. SMOKE ALARMS SHALL BE DIRECT WIRED 120V. U.L. 217 APPROVED TYPE WITH AUDIBLE ALARM INSTALLED IN ACCORDANCE WITH MANU-^ FACTURER'S RECOMMENDATIONS AND LISTING. / \ 14. ALL MECHANICAL EQUIPMENT SHALL BE PROTECTED BY OvERCURRENT DEVICES OF THR TYPE AND RATING PER MANUFACTURER NAMEPLATE SPECIFICATIONS. 15. THE ELECTRICAL CONTRACTOR IS To COORDINATE WITH OTHER TRADES TO MAKE CERTAIN THAT ALL AIR-CONDITIONINGPOWER AND CONTROL WIRING AND CONDUITS ARE IN THE BID. 16. EHAT ALLAWOHE NE ER COOARY A Y BEFTOR IS TO ORE TNATE OWER C BIDDING TO BE CERTREQUAIN MENTS WITH THE POWER COMPANY BEFORE BIDDING TO BE CERTAIN COMPANY SPECIFICATIONS IS IN THE BID. 17. PROVIDE PRE -WIRED T.V. OUTLETS HDMI AND CAT5 (FOR CABLE OR ANTENNA IN ATTIC, OR SATELLITE) AS SHOUIN PER CONTRACT. 18. ELECTRIC FIXTURES/TRIM AND APPLIANCES SHALL BE U.L. APPROVED AS PER CONTRACT. IS. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SWITCHES AT A/C EQUIPMENT, AND AT PUMPS NOT VISIBLE FROM CIRCUIT BREAKER AND AS PER MANUFACTURER'S RECOMMENDATIONS. 20. OUTDOOR LANDSCAPE LIGHTING AND JUNCTION BOXES TO BE COORDINATED WITH LANDSCAPE CONSULTANT/COMPANY. (VERIFY W/ OWNER) 21, STEREO PRE -WIRE, SPEAKERS, UNIT, ETC. TO BE COORDINATED WITH AUDIOVISUAL CONSULTANT/COMPANY. (VERIFY W/ OWNER) 22. ROUTE CONCRETE AS REQUIRED FOR FLOOR OUTLETS VERIFY DEPTHS W/ STRUCTURAL ENGINEER BEFORE COMMENCING (IF REQUIRED). 23. PROVIDE A NEW COMPLETE TYPEWRITTEN DIRECTORY FOR EACH PANEL. 24. DIMMERS TO BE SINGLE POLED WITH PRESET DIMMER 25. ALL RECEPTACLE, SWITCHES, TV, PHONE, ETC. LOCATIONS ARE SUBJECT TO CHANGE IN FIELD DUE TO CODE ISSUES. ELECTRICAL CONTRACTOR MUST FOLLOW ALL CITY, COUNTY, STATE, AND NATIONAL CODES OVER DESIGNED DRAWINGS. AS GUILTS CAN BE SUPPLIED IF REQUIRED. DRAWINGS SUGGEST LAYOUT ACCORDING TO CODE AND TO BE APPROVED BY GOVERNING MUNICIPALITY DURING THE PERMITTING PROCESS. 26. ALL RECEPTACLES TO BE 6'-0" O.C. FROM ALL OPENINGS, AND IV-& O.C. FROM RECPT. TO REGEPT ALL RECEPT. 2' O.G. AT KITCHEN COUNTER 27. ELECTRICAL CONTRACTOR SHALL VERIFY ENGINEERS ELECTRICAL LAYOUT AND CALC5. PRIOR TO CONSTRUCTION. REPORT ANY DISCREPANCIES IN WRITING (%i -C�'39 ST LUCIE CON BUILDING DIVI N REVIEW FOR COMP IA REVIE ED BY DATE-Ight Iia PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE THESE PLANS AND ALL PROPOSED'° ui l;t ACE SUBJECT TO ANY COfIIACCTICia KZOUIRED BY rI.°L0 q SPECTORS LAT L4AY UE NECESSARY IN ORDER TO COMFLY`'dITHALLAFPLICAI EC DES. G6rrC L � S' nER�ORAiT1CG MFNiS ARE THE RESPONSISIV y OF THE CONTRACTOR OF CORM FILE COPY JAMES C. PAINE, JR. ARCHITECT FIRM LIC.#0009524 2831A EXCHANGE CT WEST PALM BEACH FLORIDA 33409 (561)346-4685 FAX (561) 686-5862 THIS DRAWING IS AN INSTRUMENT OF SERVICE. AND AS SUCH SHALL REMAINTHE PROPERTY OF THE METRO DESIGN GROUP. UNAUTHORIZED USE OR REPRODUCTION WITHOUT WRITTEN PERMISSION OF THE METRO DESIGN GROUP IS PROHIBITED. THIS DRAWING IS FOR USE IN CONNECTION WITH THIS PROJECT AND SHALL No BE USED FOR ANY OTHER LOCATIONS COPYRIGHT 2015 JAMES C. PAINE, ALA. Q LL a� a(n LU (1) Z 0)z �z W C)WM iM Q' co0 VU j N� pUY Cm a 16 O Q N O U { Q � w 81 SHEET 0 p S' • 9 OF 9 SHEETS _I CAD drafting by Des ierPrafting78.com - 56IV33.7731 Under the direct supervision of James C. Paine