HomeMy WebLinkAboutEPL DISPLAY CARDSCANNED
R405-2017� �BY
St Lude Cvu*
ENERGY PERFORMANCE LEVEL- (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.65
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.75
SHGC: SHGC=0.25
c. U-Factor: Dbl, U=0.78
SHGC: SHGC=0.25
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. WA
434 SE Naranja Ave, Port St. Lucie, FL, 34983
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=5.0
2069.80 ftz
b. Frame - Steel, Adjacent
R=11.0
195.93 ft
1
c. N/A
R=
ft2
4
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=30.0
2581.60 ft2
2461
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
242.88 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 532.4
136.04 ft2
12. Cooling systems
kBtu/hr
Efficiency
119.13 ft2
a. Central Unit
45.7 SEER:16.00
ft2
4 13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
35.2
COPA.00
5.647 ft.
0.250
Insulation Area
R=0.0 2461.d0 ft2
R= ft2
R= ft2
14. Hot water systems
aCap: 1 gallons
. Natural Gas
EF: 0.65
b. Conservation features
None
15. Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/11/2018 9:15 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software i Page 1 of 1