Loading...
HomeMy WebLinkAboutLETTER -REVISIDE CONSTRUCTION PLAN-004-� BY ME as 1Sft7�51GN ude ■ -olut* ARCHITECTS I ENGINEERS I CONTRACTORS I � VISUALIZATION 6A'ltii'@A�►u'�.f NW 2"d St. Okeechobee, FL 34972' 4247 SW High Meadows Ave. Palm City, FL 34990 22062 Concha Ave. Boca'Raton, FL..33828 P: (863) 467-1111 1 F: (863) 824-3390 1 www.GDCFlorida.com To: St. Lucie County Planning & Development Services, Building & Code Regulation Division Attn: Plan Review Ref: Scott Britton Residence — BSFR T202353 . Date: 03/21/2018 From: Shaun M. Kogut - Director C.C: John H. Creswell, P.E. — Director Dear William Durden, _.._ RECEIVED PEAR 2 3 2018 5T. Lucie County, Permitting We have revised the Construction Documents to reflect plan review comments dated 03/09/2018. All revisions have been clouded and attached. Comment 1: Could not complete my review, plans were designed to the 2014 Florida Building Code. Please check all areas of components and cladding, structural and foundation design. Al: Revised pages with revision clouds are attached, see pages G-001, S-001 and S-102. Comment 2: Please furnish the manufacturer's truss placement drawings in duplicate reviewed and approved by the design person of record in accordance with Chapter 8 Section R802 Subsection R802.1.7.1 of the 2017 Florida Residential Building Code. A2: Revised truss layout is attached, see pages S-103 and S-104. Comment 3: Please furnish truss engineering in duplicate per Chapter 8 Section R802 Subsection R802.1.7.1 of the 2017 Florida Residential Building Code A3: Reviewed by Green Design C&D, LLC, to be submitted by Builder. Comment 4: Remove all references to Port St. Lucie Building Department from the plans. See Section 107 of the 2017 Florida Building Code A4: Revised pages with revision clouds. are,attached, see pages G-001 and S-001. Comment S: See foundation notes on page S-001. Please submit geotechnical reportin compliance with R401 of the 2017 Residential Building Code. - A5: To be provided by Builder Comment.6: No product approval number was submitted for window mull bars. Please submit the'correct product approval number on plans or submit the product approval in duplicate. See Chapter 1 Section 107 of the 201Z A6: Window mull bar product approval number is attached, see page S-001. Comment 7. No product approval number was submitted for the roof underlayment. Please submit the correct product approval number on plans or submit the product approval in duplicate. See Chapter 1 Section 107 of the 2017. A7. Roof underlayment product approval number is attached, see page S-001. r ISF c��.N Comment 8s Please complete the gas piping schematic work'sheet... A8: To be provided by Builder . Comment 9:. Note: A separate permit is required for the connection from the structure to the LP hook-up and if a LP tank is to be installed as well. . A9: To be provided by Builder Please feel free to call if you have any further questions or concerns. Regards, Shaun M. Kogu —Director AM 26003565 COM 30250 Green.Design Construction.and Development, LLC . P:863-467-1111 - F:863-824-3390 Shaun@gdcflorida.com