Loading...
HomeMy WebLinkAboutREVISION 10-4-18OFFICE USE ONLY: I DATE FILED: REVISION FEE: SCANNED �Y t LuCie Count/ Q PERMIT # ' RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-56 (772) 462.1553 . APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: T 3 /1% 4; ilP DETAILED DESCRIPTION OF PROJECT REVISIONS/1 CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: �G C O 5 �9D / ST. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRES : eO 2 S/i v r r CITY: Z0X,, ¢os7 6 eh STATE: fL ZIP: PHONE (DAYTIME): 4-Z 3 7 6 FAX: OWNER/BUILDER INFORMATION: NAME: ADDRESS: /lG.SAl 4,0� � C CITY: STATE: L ZIP:9 PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: 4-e 7'Prr'-'a/ /5zir= zD 7" ADDRESS: )G CITY: ¢ Wb v STATE: PHONE (DAYTIME): 1X9- /e�e-3 SLCCC: 9123109 Revised 06130117 File Copy ZIP: FAX: OCT 04 2018 Permitting Department St. Lucie County, FL FORM R406-2017 � f RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: [5 This checklist E/ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a -ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst -case orientation, name and version of the compliance software tool, name of individual completing the compliance report (one page) and an input summary checklist that can be used for field verification (usually four pages/may be greater). Or Energy Performance Level (EPL) Display Card (one page) ff HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 El""'Mandatory Requirements (five pages) THESE PLANS A{yD ALL PROPOSED WORK Required prior to CO for the Performance Method: ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORppER TO ❑ Air Barrier and Insulation inspection Component Criteria chec �1f''9ft LICAB r ' LE CODES. one page) ❑ A completed Envelope Leakage Test Report (usually one page) ❑ if Form R405 duct leakage type indicates anything other than "default leakage" then a completed Form R405 Duct Leakage Test Report (usually one page) 9T. tuc E C®nB UDD7G DTIV' SICY MIEWED FOR COMPLIANCE = Ram IPPEROMT IMN'T BE KEPT ON JOB 61-1 N'-41 INSPECTION. ` ML BEMADE. 10/412018 9:13:10 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 File ropy FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: - CASA ENTRECE Builder Name: Street: 434 SE NARANJA Permit Office: PORT ST LUCIE City, State, Zip: PORT ST LUGIE ,.FL . Permit Number: Owner. Jurisdiction: 661200 Design Location: FL; Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2500.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insui, Exterior R=4.1 2120.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent i R=11.0 280.00 ft2 c. Frame - Wood, Exterior R=11.0 100.00 ftz 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (2461.0 sgft.) Insulation Area a. Under Attic (Vented) R=30.0 2461.00 ft2 S. Conditioned floor area above grade (ft2) 2461 b, WA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(287.8 sgft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 146.1 a. U-Factor. Sgl, U=0,61 287.83 ft2 b. Sup: Attic, Ret: Main, AH: Main 6 149.1 SHGC: SHGC=0.22 b. U-Factor. WA ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 40.0 SEER:14.00 c. U-Factor. N/A ftz G. Central Unit 17.9 SEER:114.00 SHGC- 13. Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a. Electric Strip Heat 31.0 COP:1.00 SHGC: b. Electric Strip Heat 15.5 COP:1.00 Area Weighted Average Overhang Depth: 7.170 ft. Area Weighted Average SHGC: 0,220 14. Hot water systems 8. Floor Types (2461.0 sgft.) Insulation Area a. Natural Gas . Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 2461.00 ft2 b. Conservation features EF: 0.590 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.117 Total Proposed Modified Loads: 80.11 PASS Total Baseline Loads: ' 82.89 I hereby certify that the plans and specifications covered by Review of the plans and THIr ST,q this calculation are in compliance with the Florida Energy Code. specifications covered by this calculation indicates O 1, _ - p '��„• := '�� compliance with the Florida Energy Code. --,'•_%;:�.`,','G�ti- PREPARED PREPARED Before construction is completed ca J "- ` DATE: this building will be inspected for compliance with Section 553.908� a= t:C go I hereby certify that this building, as -designed, is in compliance Florida Statutes. ��y' with the Florida Energy Code. C D p WV_ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an - envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). , 101412018 12:39 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: CASA ENTRECE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2461 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: Rotate Angle: 90' Street: 434 SE NARANJA Permit Office: PORT ST LUCIE Cross Ventilation: County: St, Lucie Jurisdiction: 661200 Whole House Fan: City, State, Zip: PORT ST LUCIE , Family Type: Single-family FL. New/Existing: New (From Plans) Comment: 'CLIMATE Design Temp Int. Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer. Degree Days Moisture Range FL,- Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Law BLOCKS Number Name Area Volume 1 Blockl 1957 19570 2 Block2 504 6040 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1957 19570 Yes 8 3 1 Yes Yes Yes 2 Guest Room 504 5040 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 139 ft 0 1957 ft' 0 0 1 2 Slab -On -Grade Edge.Insuiatio Guest Room 54 ft 0 504 ft2 0 0 1 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area . Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2666 ftz 0 ft2 Unfinishe 0.96 No 0.7 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2461 ft' N 'N 10/4/2018 12:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1957 ft? 0.11 Wood 2 Under Attic (Vented) Guest Room 30 Blown 504 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block - Int Insul Main 4,0999 37 10 370.0 112 0 0.15 0 2 E=>S Exterior Concrete Block- Int Insul Main 4.0999 43 10 430.0 ft2 0 0.15 0 3 E=>S Exterior Frame - Wood Main 11 4 10 40.0 ft2 0.5 0.15 0 4 SE=>SW Exterior Frame . Wood Main 11 2 10 20.0 ft2 0.5 0.15 0 _ 5 S=>W Exterior Frame - Wood Main 11 4 10 40.0 ft2 0.5 0.15 0 _ 6 W=>N Exterior Concrete Block.- Int Insul Main 4.0999 28 10 280.0 ft2 0 0.15 0 _ 7 N=>E Garage Frame - Wood Main 11 28 10 280.0 itz 0.5 0.15 0 8 E=>S . Exterior Concrete Block - Int InSLOuest Room 4.0999 16 10 160.0 ft2 0 0.15 0 _ 9 S=>W Exterior Concrete Block - Int InsuGuest Room 4.0999 14 10 140.0 ft2 0 0.15 0 10 W=>N Exterior Concrete Block - Int InsLOuest Room 4.0999 36 10 360.0 W 0 0.15 0 _ 11 S=>W Exterior Concrete Block - Int Insul Main 4.0999 38 10 380.0 ft2 0 0.16 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>W Wood Main None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. W211 Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 1 Metal Single (Tinted) Yes 0.61 0.22 N 30.0 f? 2 ft 0 in 0 ft 6 in None None 2 N=>E 1 Metal Single (Tinted) Yes 0.61 0.22 N 56.0 W 10 ft 0 in 0 ft 6 in None None 3 N=>E 1 Metal Single (Tinted) Yes 0.61 0,22 N 22.5 ft2 2 ft 0 in 0 ft 6 in None None 4 E=>S 2 Metal Single (Tinted) Yes 0.61 0.22 N 3.3 ft2 2 It 0 in 0 It 6 in None None 5 E=>S 2 Metal Single (Tinted) Yes 0.61 0.22 N 20.0 W 2 It 0 in 0 It 6 in None None 6 S=>W 11 Metal Single (Tinted) Yes 0.61 0.22 N 36.0 W 2 It 0 in 0 ft 6 in None None 7 E=>S 3 Metal Single (Tinted) Yes 0.61 0.22 N 24.0 ft2 28 ft 0 in 0 It 6 in None None 8 E=>S 8 Metal Single (Tinted) Yes 0.61 0.22 N 16.0 ft2 28 It 0 in 0 ft 6 in None None 9 S=>W 9 Metal Single (Tinted) Yes 0.61 0.22 N 36.0 W 2 ft 0 in 0 ft 6 in None None 10 W=>N 10 Metal Single (Tinted) Yes 0.61 0.22 N 20.0 ft2 2 ft 0 in 0 ft 6 in None None 11 W=>N 10 Metal Single (Tinted) Yes 0.61 0.22 N 12.0 W 2 ft 0 in Oft 6 in None None 12 W=>N 10 Metal Single (Tinted) Yes 0.61 0.22 N 12.0 ft2 2 ft 0 in 0 8 6 in None None 10/4/2018 12:39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation J 1 451 ftz 451 ftz 64.ft 1,0 ft 1 I INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 —� 1 Wholehouse Proposed ACH(50) .000191 1230.5 67.55 127.W .1477 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ 2 Electric Strip Heat/ None None COPA 31 kBtu/hr COP:1 15.5 kBtu/hr 1 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ 2 Central Unit/ None None . SEER: 14 40 kBtu/hr 1200 cfm SEER: 14 17.9 kBtu/hr 537 cfm 0.75 1 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.59 1 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft, DUCTS N 2 — Supply — — Return — Air CFM 25 CFM25' HVAC # �J # Location R Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 146.1 ft Attic 31.52 ft Default Leakage Attic (Default) (Default) 1 • .1 2 Attic 6 149.1 ft Main 61.52 ft Default Leakage Main (Default) (Default) 2 2 10/41201812:39 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5 kM FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat; Y Ceiling Fans: Cooling Jan Jan Feb 'Feb [[ jj Mar [X] Mar [ [ ] Apr ] Appr [ [ j May ]Jun ] Mayr ) Jun [XJ Jul [Xj Aug [) Jul [ ] Aug n Sep Sep Oct � Oct [ ]Nov [X] Nov Dec Dec Venting Ventin Jan Feb [[[[[[�xxxxx]] Mar [X] Apr [ l] Ma l Jun (]] Jul [ J Aug Se p Oct [Xl Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80" 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 65 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68. 68 68 68 68 68 66 66 Heating (VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Strip Heat 0% 1 -Central Unit None 0 0 0 2 - Electric Strip Heat 0% 2 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/sq.ft. 0 ft= 0 ft 0.3 Main Name: Rating Compant: Signature: Date: 1 10/4/201812.39 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location varies 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 57.9 a) Split system SEER 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c)-Ground/watersour.ce SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2461 d) Room unit/PTAC EER e) Other 14.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.610 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.220 14. Heating system: Capacity 46.5 c) Area 7c. 287.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15_ Water heating system . c) Concrete, raised (R-value) 9c. a) Electric resistance EF b) Ga's fired, natural gas EF 0.59 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 11.0 e). Dedicated heat pump with tank EF 2. Masonry (insulation R value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No .b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e)`Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied- with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 434 SE NARANJA City/FL Zip: PORT ST LUCIE, FL 10/4/201812:40:03 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1