HomeMy WebLinkAboutPOLY ROOF SCREEN ROOMOF ROOF.BEA], COLUIVINS, PURLINS Al GIRTS:
THIS SCREEN ROOM MEETS THE FLORIDA BUILDING CODE FOR A HEIGHT 7'-10",150 MPH, EXP. 'C'
WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA
BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION
OF FLORIDA (AAF) "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL
VALUES FOR EXTRUDED ALLOY 60051'5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL, 2015 EDITION.
TABLE 1 MAIN ROOF MEMBER SCHEDULE
MEMBER - --'lMARKlMANF.1
WEIGHT
ATERIA
THICKNESS
ILENGTH DESIGN BASIS
#
I SKIN
I POLY I SKIN
I FT.
APPR.
POLY ROOF PANEL # 1
s •P:RP1
ELITE
1
ALUM
3"
0.024
11'-0661
1�_,FLL.PROD.
R4 DOR=0018.1Z
1 T
TABLE 2 MAIN MEMBER SCHEDULE
MEMBER
I MARK
I SIZE
I MATERIALI
TYPE
I THICKNESS
ILENGTH DESIGN BASIS
b x t
I ALLOY
I
I W
I F
I FT..
COLUMN # 1
COLUMN # 2
COLUMN # 1A
COLUMN # 2A
COLUMN # 3
COLUMN # 4
COLUMN # 5
COLUMN # 6
CHAIR RAIL # 1
CHAIR RAIL # 2
CHAIR RAIL # 3
CHAIR RAIL # 4
CHAIR RAIL # 5
CARRIER BEAM # 1
CARRIER BEAM # 2
CARRIER BEAM # 3
EDGE BEAM # 1
MID BEAM # 1
Cl
2x3-9
ALUM
HOLLOW
0.090
0.090
7'-10"
CALCULATION
C2
2x3
ALUM
HOLLOW
0.050
0.050
7'-10"
CALCULATION
CIA
2x3-9
ALUM
HOLLOW
0.090
0.090
8'-4"
CALCULATION
C2A
2x3
ALUM
HOLLOW
0.050
0.050
8'-4"
CALCULATION
C3
2x3
ALUM
HOLLOW
0.050
0.050
7-7.3"
CALCULATION
C4
2x3
ALUM
HOLLOW
0.050
0.050
7-8.7"
CALCULATION
C5
2x3
ALUM
HOLLOW
0.050
0.050
7-7.3"
CALCULATION
C6
2x3
ALUM
HOLLOW
0.050
0.050
7'-8.7"
CALCULATION
CR1
2x3
ALUM
HOLLOW
0.050
0.050
7'-8"
CALCULATION
CR2
2x3
ALUM
HOLLOW
0.050
0.050
V-8"
CALCULATION
CR3
2x3
ALUM
HOLLOW
0.050
0.050
7'-l"
CALCULATION
CR4
2x2
ALUM
HOLLOW
0.046
0.046
2'-11.5"
CALCULATION
CR5
2x2
ALUM
HOLLOW
0.046
0.046
2'-11"
CALCULATION
CB1
2x3-9
ALUM
HOLLOW
0.090
0.090
7'-10"
CALCULATION
CB2
2x3-7
ALUM
HOLLOW
0.070
0.070
V-8"
CALCULATION
CB3
2x3-9
ALUM
HOLLOW
0.090
0.090
7'-3"
CALCULATION
EB1
2x3
ALUM
HOLLOW
0.050
0.050
10'-0"
CALCULATION
MB1
2x3
ALUM
HOLLOW
0.050
0.050
10'-0"
CALCULATION
ADDITIONAL SITE SPECIFIC INFORMATION
THIS POLY ROOF SCREEN ROOM IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SE WALTON ROAD AND
EAST OF U.S. ROUTE 1 IN PORT ST. LUCIE. THE SCREEN ROOM HAS SOME OPEN AREAS AROUND IT. THE ENCLOSURE
IS CLOSE TO THE SAVANNAS PRESERVE STATE PARK. PER THE EXPOSURE CATEGORIES LISTED IN SECTION
1609.4.3 OF THE FLORIDA BUILDING CODE THIS ENCLOSURE SHALL CONSERVATIVELY BE CALLED AN EXPOSURE 'C'.
ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF 'APPLIED TECHNOLOGY
COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY I ENCLOSURE IN THIS LOCATION IS
DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND
LOAD, EXPOSURE 'C', RISK CATEGORY I.
THE NEW POLY ROOF SCREEN ROOM IS BEING INSTALLED ON AN EXISTING NOMINAL 4" SLAB THAT IS IN GOOD
CONDITION. THIS FOUNDATION IS ACCEPTABLE FOR THIS SCREEN ENCLOSURE. THE FRONT IS 7'-10" HIGH AND THE
REAR IS 8'-4" HIGH; WITH A RUN OF 10 FEET GIVES A SLOPE OF ABOUT 0.50 INCHES PER FOOT. THE POLY ROOF THE
DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF CONNECTION DRAWINGS ARE SHOWN ON SHEETS 3.
ADDITIONAL CONNECTION DRAWINGS ARE SHOWN ON SHEET 4. SEE KNEE BRACE CONNECTION SKETCH BELOW.
COUNTYST :
: -
0) ALL rhUf UaMU vywnr%
R1
R1
SPECIFICATION NOTES AND DESIGN; -�ARAMETERS:
THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE 2017 FLORIDA BUILDING CODE, SIXTH
EDITION, BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A. THE
AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR THE TABLES ARE APPLIKE
A DESIGN BASICS: THIS POLY ROOF SCREEN ROOM IS A RISK CATEGORY I STRUCTL HEIGHT 7'-10", 150 MPH, EXP. 'C'
B THE BUILDING CLASSIFICATION RISK CATEGORIES ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED PER
FBC, FIGURE 1609C. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10.
•C DESIGN PRESSURE: SCREEN WALL(18114) WW @ 32.54 PSF, LW @ 25.73 PSF; SOLID ROOF @ 30.96 PSF PER TABLE 2002.4.
D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD.
E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC.
F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES.
2 MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD):
A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE.
B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR
300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF
DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESE SECTIONS.
ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY
INSTALLATIONS UTILIZING THE SUBJECT METHODS.
C SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58% OPEN MINIMUM.
OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION.
D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL FBC AND AAF GUIDELINES.
E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME.
F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBER, RESPECTIVELY.
G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT
SCREENING OR KICKPLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER.
H ALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER.
I IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE COLUMNS ARE NOT DISTURBED.
3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS,
COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS,
ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE
IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL CONNECTIONS SHALL MEET THE
FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR.
4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING, EAVE RAILS AND CHAIR RAILS, ALONG WITH
ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SITE SPECIFIC DRAWING".
5 ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED FOR SUFFICIENT HOLD DOWN
CAPABILITY TO MEET THE CODE REQUIREMENTS. ALSO, ALL TAPCONS, WEDGE ANCHORS (OR EQUAL) SHALL BE 24" O.C.
(MIN.), BE 3" FROM THE EDGE OF THE SLAB AND HAVE A MINIMUM EMBEDMENT OF 2" INTO THE CONCRETE SURFACE.
6 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN
ANY TWO BEAMS MUST BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE
AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C.
7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS:
A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH.
B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2".
8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS,
B 4" NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS,
C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE,
D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE.
9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM:
A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, MANNIE J
B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTERS. By
10 ALL NEW PERIMETER FOOTER POURED WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS: 7- Lucie Caux
A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED,
B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE.
11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING.
12 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL,
PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT.
OLY ROOF SCREEN ROOM
WG. # RVC-2018-202, REV.1
February 20, 2018
SHEET 1 OF 4
.2
v GEC C DESIGN DATA
150 MPH. EXP. 'C'
33fq)POLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
LOCATION:
NAME:
WESCOTT RESIDENCE
ADDRESS:
7716 WHITE EGRET LANE
CITY/STATE:
PORT ST. LUCIE FL 34952
COUNTY:
ST. LUCIE
REVISION UPDATED THE PRODUCT
20VAL FOR THE POLY ROOF
:LS. SEE SHADED AREA. ONLY
:T 1 IS AFFECTED.
THIS DRAWING IS ONLY ACCEPTABLE
FOR BUILDING PERMITS & ONLY WHEN IT
HAS THE ENGINEER OF RECORD'S RAISED
SEAL. COPIES ARE NOT DEEMED VALID.
THIS DOCUMENT IS THE PROPERTY OF
R. A. DUNLEA, P.E. AND SHALL NOT BE
REPRODUCED IN WHOLE OR IN PART
WITHOUT THE WRITTEN CONSENT OF
R. A. DUNLEA.
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunlea(c-centurVlink.net
FLORIDA P.E. Lic. No. 42835
_.aTHOArt,
SITE SPECIFIC DRAWING
� POLY ROOF SCREEN ROOM
MODULAR HOME
I8'-4" I
rr
3'-0"
3'-1.5"
10'-0"
3'-1.5"
7'-10"
LEFT SIDE ELEVATION VIEW
NOTE: THE BACK ELEVATION
VIEW, MEMBERS AND SPACING, IS Fs -
EXACTLY THE SAME AS THEFRONT ELEVATION VIEW EXCEPT
THE HEIGHT IS 6" HIGHER. "
NOTE: THE BACK COLUMNS I
WILL BE DESIGNATED AS 7'-10"
CIA & AND C2A ON SHEET 1,
TABLE 2.
MODULAR HOME
NOTE: THERE WILL BE KNEE BRACE;
(KB) BETWEEN THE FRONT AND BACI
COLUMNS AND THE EDGE BEAMS
AND THE MID BEAMS, (MB)THE SAME
AS SHOWN ON THE SIDE ELEVATION
VIEWS. THE 2x3 EDGE BEAMS AND
MID BEAMS SHALL BE ATTACHED TO
THE UNDERSIDE OF THE POLY ROOF
WITH #12 SMS, 3" LONG, STARTING
6" FROM EACH EDGE AND EVERY 24"
O.C. FROM THE FRONT TO THE BACK
COLUMNS: THE EDGE AND MID
BEAMS SHALL ALSO BE SECURED
TO THE COLUMNS, SIMILAR TO THE
KNEE BRACE CONNECTIONS.
3"- 1 LB. POLY ROOF
MODULAR HOME
NOTE: THERE SHALL BE NO
STRUCTURAL ATTACHMENT
BETWEEN THE COLUMNS AND
THE MODULAR HOME AND
BETWEEN THE POLY ROOF
AND THE MODULAR HOME. IT
IS ACCEPTABLE TO INSTALL
FLASHING BETWEEN THE
MODULAR HOME ROOF AND
THE POLY ROOF OR CARRIER
BEAM TO KEEP THE RAIN OUT.
E: THERE ARE A TOTAL OF
(10) KNEE BRACES USED
E; ONE BETWEEN EACH
JMN AND ASSOCIATED
E BEAM OR MID BEAM.
12"
NOTE: THE KB SHALL BE
2x3x0.070 MEMBERS, CUT ON A
450 ANGLE AT EACH END WITH
THE SHORTER SIDES AT 16"
LONG AND THE LONGER SIDES
AT ABOUT 18" LONG. SEE
SKETCH TO RIGHT. AN
ALUMINUM CHANNEL, 2 x 2.25 x
2 x 0.125" THICK, SHALL BE
ATTACHED TO THE COLUMNS,
EB OR MB, MEMBERS AT EACH
END OF THE KNEE BRACE AND
SECURED TO THE COLUMN AND
EB OR MB SIX (6) #12 SMS. THE
KB WILL BE INSERTED INTO THE
CHANNEL AND SECURED WITH
SIX (6) #12 SMS, THREE (3) ON
EACH SIDE OF THE CHANNEL.
I 32'-0"
PLAN VIEW
MODULAR HOME
(CONT.):
CHANNELS SHALL BE 3" LONG
AND THE NEARER EDGE SHALL
BE -12" FROM THE CORNERS.
. 18"
\ KNEE �B�RACE /
3" -1 LB. POLY ROOF
...I A AY L. @V-
II I1 11 11 it
2" -- 7'-10" 2" 6'-10" 2" 7'-3- 2" 7'-3" 2"
FRONT ELEVATION VIEW
MODULAR HOME
10'-0"
3'-1"
5'-8"
7'-10"
RIGHT SIDE ELEVATION VIEW
NOTE: SCREEN DOORS MAY BE ADDED
AND OR RELOCATED USING DOOR
JAMS AT ANY TIME PROVIDING THE
COLUMNS ARE NOT DISTURBED.
NOTE: CHAIR RAIL MAY BE RAISED TO
3'-0" OR LOWERED TO 1'-4", IF DESIRED.
DWG. # RVC-2018-202, REV. 0
January22, 2018
SHEET 2 OF 4
SITE DESIGN DRAWING
HEIGHT 7'-10",150 MPH, EXP. 'C'
R V CONSTRUCTION
3318 COLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
LOCATION:
NAME:
WESCOTT RESIDENCE
ADDRESS:
7716 WHITE EGRET LANE
CITY/STATE:
PORT ST. LUCIE, FL 34952
COUNTY:
ST. LUCIE
DRAWINGS NOT TO SCALE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunlea(a-)-centurvlink.net
FLORIDA P.E. Lic. No. 42835
�PN_.••NY
pff-_�
*; 4 :*:
• TATE F
eX
RO r AI rDNNEZ7l-I0i\#_
_ - ARING
y� SECTION AT BE
STR-UCTURE. F I C.LEVA I _O N °
:_ e R :0-�[:c:R rF � �..__ ... COLUMN
;~ 3w •"c�:am'3° 'iPieN1SJ.�"ffE5FEAESGGEINEL'A:SI �(OE+t S':10A. �r-pF•E-RN;ElD(N;>TIQAitGN ' .SEj;10]LO4(n1VrC ° : ' -'
M-M ACOE T V4' FER
JGLSOU(DA°AX Z _ .
fbO-A-
:' ctpG; 3+W'. Gam. k7 ArSrHPFG
i3G5;CFTERS�EIIS(JRE;±':Mi(l PEPIei`(tA'CN_' CNCRETE : SF1�LE�J,wQ
I
PRE=DFc�f! , FiOL= T4 4Y/0 SPIlTFING WALL-
OR Pi _ L, r., p)
`.1'ki q.• 3
isr - MASONRY*, J N
ELri E
OK7>RL/9SR9 SR WX1T/4' EMBED ... /EP'23
TAPCON @ 2% "• )
r & 4%` FROM ° EN"DS SAL @ 18•
_ i \ MAX.
2' NOMINAL STRUCrURALC(A MINIMUM `imum `
MEP-23 �
1 7 13,G• (8) PEP 4' PANEL TOP R/YY *NOTE: USE �a°x13/a EMSED
dx? SMS ' TAPCONS, 235' & 41h' FROM ENDS;
SO ENCLOSURE
UR (N SMS 2' & 4° O EACH 14" MAX D.C. TO NOLLrO.W BLOCK
ENCLOSURE ENO TOP &.BOTTOM. HEAVY
ADHESIVE CAULK TOP $. BOTTOM CONTINUOUS
t_NCLOSURc TO CONCRETE DECK
H'4CHI iRING DETAIL
*SEE GENERAL NOTE #10 FOR ATION
COLUMN:PF.It'TAf14 5 OCR 3°13'x3--%' ANGLE WITH (2) V/d's1�4' EMBED.
SEALED.'_-sPEEC3FIC TAPCWSW/Si(e'MIN. WASHERDIAMETER TO
DRAWINGS/+ f+{ �LATIDNS SLAB, 2%1 APART & 3' FROM SLAB EDGE & (6)
414 SMS TR CQLOMN, %' FROM ANGLE EDG-S,
ONE EACH SIDE OF COLUMN
O
a
NEy/7EXiSTIPaG:GONatETE SLA5 & FOOTING. SEE SITE SPECIFIC
BETA%=aR.ADD17RONAL TOOTING ENGINEERING SHEEP
E SEAM CONNECTION @ WALL
L�NEi'-AL NOTE10 FDR LIMIT TI13
EPS POLY - (USED AS R2gURIED WHEN
ROOF CONNECTING TO WALL)
'j4• THRLSOLTTHR000H
a <•,:'. 2"z3° ° ANGLETO ROOF,
ANGLE FASTENED TO INSIDE B.
BOTrotOF CARRY BEAM W/ (Z) W
j i'c'a;•.'. ='':: 3 :i.. L7--•I THar.%OLiS EIDE, (5) #14sMS BOT TOM,
Y_ SF?M PER Fts FINEDTO CBS WALL W/ (2) i'i'X131,
1 iA2L EMBED Ofl. EAtEO ED TAPCONS OR TO WOOD (MIN 72(,
:. 'SPE F3C rNTrEGRM BY OTHERS) WITH {3)a14x1'/i°
SECTION ..4 �E IRING
COLUMN aP l
100:5
?0 3
is 5
/Sims.
TYP•..TOP & 3101 , OM
gu
150 i
r rz
_ l v �•
t i
GIJCf2-F�1
N —
RL=
a
(OPT.)• ° °p �'°° °a°.a °°
°
°
OF 1011 1: USE W LAG BOLTS
W/ 1°' MIIN. •WASHER OIAMEFEP,.
1° MIN. LONGER. THAN PANEL
THICKNESS SPACED PER LAG
SPACIA(G TABLE THIS OET•4IL
OmIOIN 2: L4" THkIBOLTS 10
ROOF, #- FROM ENDS & 17-
a.c- To 2-%V)de' ANGLES
(EITHER SIDE IF R:QLIIREO BY
BUIL3)ING OEM.
O.0 �-1V Q.[.
�; silty' VIA &
a, O.r, 10' O.C.
PER (c` PER
s - ANFLs- ANEL
- CARRY BEAM PEATABLES OR
SEALED -SITE SPECIFIC
• -13RAwuv�rr�,LaILATIaNs
BOTH OPTIONS: (2) W THRUBOLTS,
n o C'AR -, BEAM TOmLUmN
a O N0TCF COLUMN N9 CarFERTO FIT
U CARRY HEAT SNUG
IW H OPTIONS: 3R-n :6le FHGL`, (6)
#14 SMS EA L13',, `EA 413E OF COLIMN
COLUMN PER iii OR SEALED 51l c
SPECIFIC DRAWING/CALcILAXlQNS
SECTION_ AT SIDE -OF ROOF PANEL
i -
. -Fk t: :f # .S TOP(F,YP am -To
F7 rz D97° r SEETABL2•BELOW F120.sx.IISTUB�E
OVEfk COLU1TlNi. s, iH.sFmI7_N T fP.
�j''4.1_ '-JSE, " X
A3NC-�t2 X 3 SIDE Cl) ��'LAG BOLTI�f3
HETrr. 15 i CARRY BW4 Z 140,'
J BOX (SEE 1• hUN LONGER TliA '.'••
TriFfl°,i]jr,i.5`s?EGIFIEo BEAM T aLc - {5) z14 SMS 'q - -TOE OF PLATE
PANE1 T Ii9dE55
LNc" °d i;%F�Ik I)JPIS I a BE I a ' BELOW) ,n _
161in:9LJ9llll: J o 2 X VAR ��. 2• X 2" v-sue—f
_ •':ir; LAP SE&A �•i• S(4t5 0.04,i & 3" X 'O ° ' _
^ rd=NGS? 3'XO.O93'^ °Tea° ° <'°
:c"`` _•. ,• 2.a" , a 24" D.C. [NQi SHOYVMj ' =5=,°" a: ,-a
MAX. TOP °� _°__ , �< • _��,
EiOTTOM
a.
Z X 3 - - - a" 'AlIGE X.fa,"
SNAP BEAl4 TOP �SiGc JiJM ?Il.l c•ON 1H '
1I.
• "�:' ,� 3EPI4 _ , ..l `� I oeFrrT r5 SIGEOFCA%«Lf'o??I�'.::
5 L•r,.P ".^:' C 11 ZY.4
:Z)BE 3 L I �4'I.t75Q°I N MIN.) _-_au_jMN ?Eri
lu
Nt-�i:'ari0?/4lFi' I .. �.0 �fQ°�.a7e ��2' OR
�— — s _ 2 _
Zx10 .39.
�• LAGS, 4' FROM cTH35 & Z4° MAX. Q.L, 1° MIN
LONER THAN PANELTHIC TO SECURE ROOF
�1-''•�-�a To NOi�-PRIMARY WALLS ONLY- G1ULK ALL�5CR�hf
sMs ld� HEADS'
TYP, TOP &
• ° ° , ° ° ['sTE ROOF
° < a
< a ° ° PANEL '
EL1Tc � —2'ri Z BOX
EPI13 Cr7P hiLPl.
OR -
VALANC� Z°�Z".c�1e' ANGLE, (3) T14 EMS EA,
a O LEIa, E4 SILTE OF BEAM .-.
ELITE TYPE 'E•
GUTTER OPTIONAL
USE 4" LAG BOLTS W/ 1" MIN..
WASHER DIAMETER, 1" MIN. LONGER .
THAN PANEL THICKNESS SPACED PER
LAG SPACING TABLE 2.
#12) 4" SMS @
16" TYP. TOP &
BOTTOM
0
0 00 0 o EPS POLY
0 0 0 o ROOF
�Y,/12
SLOPE
ADAPTOR
SHOWN
CARRY BEAM PER TABLES
2.5 X 1.5 MIN. @ SIDE
(NON-LOADBEARIN G)WALLS
'YM't3tiJ-A51 ENlNG TO
iALUMNUFA USE TRUF —HII"x
I -
(-r : 314) AT W O.G. r EIP
1 FOR -COMPOSITE -ROOFS:
TO130-MPWY AND SPEED
! #10x (L+12°,6;m s:•wit
LXPOSUR'iE'O.E.-FOF,
; 1-1/4'0FENDER.WASHERS
ABOVL 130 MPI-IA' AND UP iO
I}
.1.5(3 MPH WNSPEED
PANEL TrIICkCAI
E 'POSORf'D°
` @ ROOF BEARING ELE
C,aUL'n' ALL DGaOSEO.RLy
plpl~I $FKRING ELEIFF (SIDE
:HEADS k-WASIJERS
WALLS)
FOR PAN ROOFS:
PER 1'_PPII{=Lf13/4�
_
'ALtltAftdU&l:PA 14-_ ASHER
• _ _ ... -
=
R{DOFPANEL
a SCJPPORTING'BEANI
RM R00F_PA9EL Tb BEANI.EASTENI G:DE�`At
2- x 3' COLUMN SHOWN
SCREEN
2-x 2'x111i-ANGLE EACH SIDE
_
3-#14 SMS EACH SIDE
DO CONCRETE ANCHOR
1^O.C. MIN.
(IAPCON OR EQUAL). w/
(T
2^ EMBEDMENT MIN
1) THIS DETAIL MAY NOT BE USED
FOR COLUMNS LARGER THAN 2- x 3', 2• MIN.-a'� „r. 4) CONCRETE FASTENER SPECIFICATIONS:
2) TWO (2) 313- DIA. BOLTS MAY BE CONCRETE FASTENERS MUST HAVE A
SUBSTITUTED FOR THE 3- R74 SMS (2 _ _ (MIN.) ULTIMATE TENSION CAPACITY OF
BOLTS REPLACE 6 SCREWS) 2,566 $ OR A WORKNG (MINIMUM) TENSION
3) THIS CONNECTION CAN BE USED IN ' ., CAPACITY OF 6409, AND, A (MINIMUM)
WOOD BY USING SIMILAR SIZE i"
F `-�" WORKING SHEAR CAPACITY OF 3DI&. (DO
SCREWS IN THE HEADER NOT SUBSTITUTE 3111- DIAL CONCRETE
`• - ' ANCHORS FOR LARGER SIZE ANCHORS.) .
COLUMN / FOUNDATION FASTENER FOR 2x2 AND 2x3
LOAD CONDITIONS: CONNECTION UPLIFT CAPACITY =1.1006, SHEAR CAPACITY = 228#.
POLY ROOF SCREEN ROOM
DWG. # RVC-2018-202, REV. 0
January 22, 2018
SHEET 3 OF 4
POLY ROOF CONNECTIONS
HEIGHT 7'-10", 150 MPH, EXP. 'C'
R V CONSTRUCTION
3318 COLUMBRINA CIRCLE
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
. .. LOCATION:
NAME:
WESCOTT RESIDENCE
ADDRESS:
7716 WHITE EGRET LANE
CITY/STATE:
PORT ST. LUCIE, FL 34952
COUNTY:
ST. LUCIE
THIS "CIRCLED" CONNECTIONS
ON THIS SHEET ARE BEING
USED FOR THIS PROJECT.
1 2 3
4 5 6
7 8 9
10 11
NOTE: DRAWINGS ARE
NOT TO SCALE
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunlea0lcenturviink.net
FLORIDA P.E. Lic. No. 42835
TAT F [V
�O,c�'•••FCOR�pA: • N
400,
ON AL
I
TERNATE CONNECTION: (2) # 10 x 2"
LNG S.M.S. THRU SPLINES GROOVES
EDGE
1" x 2" OPEN BACK
'
ATTACHED TO FRONT,
i
SIDE WALL HEADER
POST w/ #10 x 2" LONG
;
ATTACHED TO I" x 2"
S.M.S. MAX. 6" FROM
;
OPEN BACK w/MIN.
EACH END OF POST
TWO (2) #10 S.M.S.
AND 24" O.C.4�
U
NOTE: THIS CONNECTION
SIDE WALL GIRT ATTACHED
IS ALSO GOOD FOR.1x3
,
TO 1" x 2" OPEN BACK w/
OPEN BACK MEMBERS,
MIN. THREE (3) #10 x 1-1/2"
2x2H AND 2x3H MEMBERS.
,
S.M.S. IN SCREW BOSSES
FRONT WALL GIRT—>
;
V x 2' OPEh
ATTACHED TO
POSTw/#10x2'
S.M.S. MAX. 6'
EACH END OI
AND 2
3OTTOM RAILS
NCRETE w/ 1'4" x 2-1/4"
INRY ANCHORS @ 6"
'AND 24" O.C. MAX. AND
)M EDGE OF CONCRETE.
TAPCON (OR =)
ROOF
RISER PANELS
POLY ROOF SCREEN ROOM
DWG. # RVC-2018.202, REV. 0
January 22, 2018
SHEET 4 OF 4
CONNECTION DRAWINGS
FOUR (4) 1/4" x 4"
LAG BOLTS wl 1-114"
HEIGHT 7'-10",150 MPH, EXP. 'C'
FENDER WASHERS
BEAM OR=HEADER
PER 4'-0" PANEL
R V CONSTRUCTION
ACROSS THE FRONT
3318 COLUMBRINA CIRCLE
8� ALONG THE SIDES
_ _ _ _
_ -----------------
PORT ST. LUCIE, FL 34952
OFFICE (772) 380-8253
LICENSE # CRC 1330965
HEADER ATTACHED TO POST
2x2 OR 2x3
ANGLE CLIPS MAY
w/ THREE (3) #10 x 2" LONG
HOLLOW
BE SUBSTITUTED FOR
S.M.S. INTO SCREW BOSS
INTERNAL SCREW SYSTEM
LOCATION:
NAME:
WESCOTT RESIDENCE
ANCHOR 1" x 2"
POST ATTACHED TO
ADDRESS:
EXTRUSION TO
BOTTOM W/ MIN THREE
7716 WHITE EGRET LANE
CONCRETE w/ 1/4" x
(3) #10 x 2" LONG S.M.S.
CITY/STATE:
3-114" CONCRETE
INTO SCREW BOSS
PORT ST. LUCIE, FL 34952
ANCHORS WITHIN 4" OF
4" MAX
4" MAX.
COUNTY:
BACK
ST. LUCIE
POSTACH AND 214' O.C. MAX.
RAI
BOTTOM RAIL
NOMINAL 4" SLAB �' ``tLz
gyp `` VAPOR BARRIER
3000 PSI GONG, 6 UNDER CONCRETE
x 6 -10 x 10 W.W.M.B,.IF NEEDED
OR
OR FIBER MESH
TYPICAL UPRIGHT DETAIL
CONCRETE DECK ANCHORING DETAI
The detail to the left shall be secured with two
(2) 2" X 2" X 2" x 1/S" thick angle (Capri'Clip)
w/ two (2) #14 SMS securing the angle to the
upright and two (2) securing the angle to the
-base plate. The base plate shall be secured to
::the slab w/ one (1) 1/4" Tapcon, erribedded.a
-- _� min. of 2 'in the slab w/ 5/8" min. washer dia.
Ta p co n must be within 6" of the upright.
4- ##10 S.M.S. FROM
INSIDE FACE OF POST
INTO SCREW SPLINES
OF HOLLOW GIRT
(2" SCREWS MIN.)
GIRT OR CHAIR RAIL
SELF MATING POST ->
ANGLE (CAPRI) CLIPS MAY
BE SUBSTITUTED FOR
INTERNAL SCREW SYSTEM
CONNECTION W/ CONCEALED FASTENERS
PARTIAL. ELEVATIONS / GIRT TO POST CONNECTIONS
THE "CIRCLED" CONNECTIONS
ON THIS SHEET ARE BEING
USED FOR THIS PROJECT.
1 2
3 4
DRAWINGS NOT TO SCALE
THE CONNECTIONS ON THIS
SHEET ARE OPTIONAL.
R. A DUNLEA, P.E.
1513 CERVANTES PLACE
THE VILLAGES, FLORIDA 32159
(772) 285-6444, (352) 750-6207
bobdunleaCaD-centurVlink.net
FLORIDA P.E. Lic. No. 42835
•G �
j
0:• STATE F .'
�0* •"Seen•••
"is�OIdA1. — �•••