HomeMy WebLinkAboutMETAL CARPORT INSTALLATION PLAN & DETAILFBC APPROVED PRODUt LIST
METAL CARPORT INSTALLATION PLANS AND DETAILS
MAXIMUM
APPROVAL... AND
PRODUCT.CATEGORY SUB CATEGORY MANUFACTURER ALLOWABLE FRAMING I
No. RAM G DATE P%:L7
WIND SPEED - AND FASTENER SPECIFICATIONS
STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS; INC. FL6596.1-R5 180 SCANNED
26 Gauge AG Panel 1.0/10/17 BY FOR.CONSTRUCTION IN THE
��yy STATE OF FLORIDA
STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.1-R5 180 m Lucie. COuney
26 Gauge AG Panel 10/10/17 PREPARED FOR. -
STRUCTURAL COMPONENTS FLOOD VENT FLOOD FLAPS, LLC FL17381.1-R2 NA CAROLINA CARPORTS; INC.
8x16 Flood Flap 10/03/17 P.O. BOX.1263
'f'HatNI' AND ALL PROPOSED WORk DOBSON, NORTH CAROLINA 270:17
EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.3 139 h:SE.SUNh4rT TO rQ.P�Gf?C�h dlrl�
Series 402-14 09l07/15 PREPARED BY.•
REQUIRED BY FIELD INSPECTOR'S THAT BECHTOL_ENGINEERINGAND TESTING, INC.
EXTERIOR DOORS SWINGING ELIXIR DOOR.AND METAL COMPANY FL17996.5 170 `�i`t+ BE ��'lrCSSA'n TO
605 WEST. NEW YORK.AVENUE
Series 407 09/07/15: _
C01plikV M11 I.4 ALL APPI4 ABLE CODES. DELAND., FLORIDA 32720
EXTERIOR DOORS ROLL -UP ASTA RIES INC. FL8888A-R5 180 Certificate of Authorization No: 00005492
203 10/06/17
WINDOWS SINGLE HUNG POCAHONTAS'ALUMINUM COMPANY, INC. FL12940.2-R4 139
Model 100 VS 01/07/16
WINDOWS
SINGLE HUNG
MI WINDOWS AND DOORS
FL17499.3-R2
180
Model -185 SH
. 12/29/17
TABLE 1 .
RAFTER FRAME, END POST, GROUND ANCHORAND'PANEL FASTENER SPACING SPECIFICATIONS
AVERAGE FASTENER SPACING
ON -CENTERS ALONG RAFTERS OR
MAXIMUM
PUR. LINS, AND POSTS. OR GIRTS.
(INCHES) .
WIND
ULTIMATE
NOMINAL
POST / RAFTER
..
RISK
EXPOSURE
WIND. SPEED
WIND SPEED
SPACING
INTERIOR
END
CATEGORY
_ cAtEGORY
(MPH)
(MPH)
(FEET)
POSTS/RAFTERS
POSTS/RAFTERS
110 TO 1.50
89 TO 116
5.0
6
6
C
151 TO. 180
117 TO 139
46
6
6
GROUND -ANCHOR SCHEDULE
ULTIMATE WLND SPEED.(r' ph): .
1.10.:120'. 130:.140' 1'50' .160 170 180
a
12.
14.F
D
=
181-
:
(9,
0
' 20
22
24
48"
Detail
Anchor
1
C .
OD
26
28
3Q
�60 Anchor
Detail :1 C -
gG2.vogg
ST. LUCIE COUNTY
BUILDING DIVISION
:REVIEWED
FOR COMPLI
REVIEWED BY
DATE 3-
PLRNS AND. PE IT .
MUST SE KEPT-OOB OR
NO INSPECTIOIU MV L BE PJfADE
NOTES:
DETAILS 1 C'AND I D SHOWN ON SHEET 4 OF 5.
THIS IS TO CERTIFY THAT -THE CALCULATIONS AND
1. Specifications applicable
to 26 gauge metal roof and wall panels
fasteneddirectly to 12 or 14 gauge steel tube framing, or 18 gauge hat
channel roof purlins.
SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE
2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7" to 27° (175:12 to 6:12 pitch). Spacing
UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN
requirements for other roof heights and/or slopes may, vary. •
ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF
THE FLORIDA, BUILDING CODE, SIXTH EDITION 201 THE PLANS,
GENERAL' NOTES: -
ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING
1.
THESE PLANS PERTAIN ONLY TO TFIE STRUCTURE, INCLUDING' MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN.ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING,
CODE.
ELECTRICAL; INGRESS/EGRESS, PROPERTY SET -BACKS; OR OTHER LOCAL ZONING REQUIREMENTS.ARE THE RESPONSIBILITY OF.OTHERS.
2.
THESE: STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS_(RISK:CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS -NOT
TECH [A� R N�%A�I�� TING, INC.
SPECIFICALLY ADDRESSED HEREIN WHICH EXERT ADDITIONAL LOADS ON THE STRUCTURE, AND INSTALLATION OF DOORS, WINDOWS OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED PRODUCTS LIST ON THIS SHEET, AND NOT
'INC.
605HWV��ST RKAy�pU
PROVIDED AND INSTALLED BY CAROLINA'CARPORTS, SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAM_ AGE OR FAILURE DUE TO THE APPLICATION OF'
DELAtJI); F J�6�SIA 3272@"�t
C6ffl1z96d1Atft0r.hMtI0 �`.'
"
'ADDITIONAL LOADS OF NON -APPROVED COMPONENTS.
•, y �.
3.
ALL STEEL TUBING SHALL BE 50, KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL.
4.
FASTEN METAL ROOF AND WALL PANELS TO -FRAMING WITH #12-14 x 3/4" SELF DRILLING FASTENERS WITH CONTROL SEAL WASHER @ 6" O.C. AVERAGE.
ThI; P
Rodd Anse o.38538
5.
ALL FIELD. FRAMING CONNECTIONS, SHALL BE #12-14 x W4^ SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.
.
A Op
6•
CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40..CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 WELDED WIRE
�ORIDA
FABRIC COMPLYING WITH ASTM-A 185; OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM C1116:
/S�i'.
. .
Oj' 4G\�\\
7.
BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR
E
CONCRETE SLAB CONSTRUCTION; EXCEPT AS SHOWN ON DETAIL 1 E, SHEET 4 OF 5, WHERE BASE RAIL IS FLUSH WITH EDGE OF SLAB. SEE GROUND.ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS.
e•
/+
CAROLIN//�
'1 CARPORTS, I:NC.
CONCRETE EXPANSION ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT.
9•
POST/RAFTER BRACING: BRACE ON EVERY POSTIRAFTER CONNECTION, EXCEPT FOR END WALLS AND GABLE ENDS.
GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
10.
SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017) (FBC FE 2017) - RESIDENTIAL, AND SECTION 1816.1
MV
01/02118 =
OF THE FBC FE 2017 - BUILDING.
BECHTOL ENGINEERING
O1" MKB
"" NTS -
11.
14 GA FRAMING IS 2-1/2" x 2-1/2" TUBE STEEL (TS), NIPPLES ARE 2-1/4" x 2-1/4" 12 GA TS FOR 14 GA FRAMING. 12 GA FRAMING IS 2-1/4" x 2-1/4" TS. NIPPLES ARE 2" x 2" 12 GA TS FOR 12 GA FRAMING.
AND 7E97WG, /ec.
OaaniOio mmri tucu eavRoaltular. "M UMMS T.MTM olaXEM
RR
"n"d 018001
C�ldMA Ib 01 0=
�TB
SHEET 1 OF 5
BOW FRAME RAFTER - .-E'EN CARPORT - HORIZONTAL ROb.- BOW FRAME RAFTER .ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER UTILITY 136iL'ING - HORIZONTAL ROOF
- S ROLL UP DOOR WINGING DOOR ROLL -UP DOOR SWINGING DOOR
(As applicable) (As applicable) (As applicable) (As applicable)
6' --
6'
u ENCLOSED LENGTH VARIES
TYPICAL SIDE ELEVATION , TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE -ELEVATION. TYPICAL END ELEVATION
NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE '
BOX EAVE FRAME RAFTER. OPEN CARPORT -.HORIZONTAL ROOF BOX EAVE FRAME.RAFTER ENCLOSED BLDG -HORIZONTAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF
ROLL -
UP DOOR SWINGING DOOR
ROLL -UP DOOR SWINGING DOOR
(As applicable) (As applicable) (As applicable) (As applicable)
6•
ENCLOSED TH VARIE
TYPICAL SIDE ELEVATION TYPICAL END. ELEVATION .. TYPICAL SIDE. ELEVATION' - .. TYPICAL END ELEVATION TYPICAL END, ELEVATION .
NOT TO SCALE NOT TO SCALE NOT TO.SCALE NOT TO SCALE NOT NOT T
TYPICAL SIDE ELEVATION .
TO SCALE ALE,
BOX EAVE FRAME 'RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE 'FRAME. RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF
ROLL -UP DOOR - SWINGING DOOR ROLL -UP DOOR SWINGING DOOR
(As applicable) (As applicable) "1.
(As applicable) - (As applicable)
- ENC OSED LENGTH VARIES ,
TYPICAL SIDE ELEVATION' TYPICAL END ELEVATION. TYPICAL.SIDE ELEVATION.: TYPICAL END ELEVATION
TYPICAL SIDE ELEVATION , TYPICAL END ELEVATION
NOT TO SCALE NOT TO SCALE NOT TO.SCALE' - NOT TO SCALE NOT TO SCALE NOT TO SCALE
BECHTQ)E EEE I� Q 1 i, INC.
605 WEsr_NEW YOPk AVENUE ' C` �
DELAND,, ORIDA 32720I�I i
Ceorizadon t� 53$
Thomas e
+ Ji n pem J. jiju i ai./j' Il lg. i~N Florida LlEn .38535!A7 OF
. �- R ZI tjL.IECT ,1 V Y I+ITi 6:vifi9EC" GO INS
`20 BY HELD 1�4SPEGTORS THE
0
P"I
� ���St�RY M. OR i C CAROLINA CARR �3, INC.
C:liV11 !". ALA APPUC04BLE corm. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA
TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION 01/02/18
NOT TO SCALE NOT TO SCALE NOT TO SCALE BECHTOL ENGINEERING � MKB WAM . NTSmU�
AND 7ESflNG, /am
misuimio cformairu, arreraNVatra. um Wimws nsnNc W 'rnm RR ^m'"-� - G18001
°i�`°�OpppQ1p� AF'° � TB I SHEET 2 OF 5 .
26 GA. GALVANIZED METAL ROOF R (a FASTENED
TO PURLINS WITH #12-14 x 3/4' SDFs �. CONTROL
SEAL WASHER @ AVERAGE 6' D.C. SPACING
26 GA. GALVANI1 ETAL ROOF PANELS FASTENED
TO RAFTERS Wll. ,, _ 1 1-14 x 3/4' SDFs WITH. CONTROL
SEAL WASHER @ AVERAGE 6' O.C. SPACING1
`24" 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
_
(2) #12-14 x 3/4' SDFs AT
9
EACH END (4 PER BRACE)
Ig
24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER
c
'24'TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER
O
AS SHOWN ON THIS SHEET
TYPICAL
INTERIOR.RAFTEWPOST FRAME. SECTION - BOW FRAME
NOT TO SCALE
LENGTH VARIES DEPENDING ON
JMBER AND SPACING OF RAFTERS
SEE
TABLE 1
SHEET
1OF5
TYPICAL RAFTER/POST FRAMING PLAN -
NOT TO SCALE
12' MAX. OPENING
FOR ROLL -UP DOOR
WITH STRUCTURAL
(TYPICAL)
`% 26 GA. GALVANIZED METAL ROOF PANELS FASTENED
\ ' TO RAFTERS WITH #12-14 x 3/4' SDFs WITH CONTROL
SEAL HER @ AVERAGE 6' O.C. SPACING
12
24" 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4' SDFs AT
EACH END (4 PER BRACE)
24' MAximum RAFTER SPAN ON SINGLE RAFTER
,24'TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER
AS SHOWN ON'THIS SHEET
TYPICAL INTERIOR RAFTER/POST
FRAME SECTION - BOX EAVE - HORIZONTAL ROOF
NOT TO SCALE
LENGTH VARIES DEPENDING ON
NUMBER AND SPACING OF RAFTERS
SEE
TABLE 1
SHEET
3-
1 OF 5
4
TYPICAL RAFTERIPOST FRAMING PLAN - BOX EAVE
NOT TO SCALE
OPENING FOR SWINGING
DOOR WITH NONSTRUCTURAL
HEADER
NONSTRUCTURAL HEADER
TYPICAL SIDE WALL OPENINGS FRAMING PLAN. AND1Nwo0w RAIL
(Also appliea6le to End Walls)
NOT TO SCALE
ROOF EXTENSION OPTION
24' 16 GA U-CHANNEL BRACE
FASTENED TO RAFTER WITH
(2) #12-14 x 3/4" SELF -DRILLING
SCREWS AT EACH END
(4 PER BRACE)
MAIN STRUCTURE
LEAN-TO
SEE
TABLE 1
SHEET
1-1/2' 18 GAUGE FURRING
CHANNEL (PURLIN)
�24' 16 GA U-CHANNEL BRACE
=
c�
FASTENED TO RAFTER WITH
(2) #12-14 x.3/4' SDFs AT
EACH END (4 PER BRACE)
O
W
J
24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER
.�-
>24' TO 3V RAFTER SPAN REQUIRES ATRUSSED RAFTER
O
AS SHOWN ON THIS SHEET
F
TYPICAL INTERIOR
RAFTER/POST FRAME SECTION - VERTICAL ROOF
NOT TO SCALE
1-1/2" 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING
FASTENER SPACED NOT MORE THAN 48' O.C.
SEE
TABLE 1
SHEET
1 OF 5
I VARIES DEPENDING ON NUMBER
AND SPACING OF RAFTERS
TYPICAL
POST/RAFTER FRAMING PLAN - VERTICAL ROOF
NOT TO SCALE
LFE C 0 p
TYPICAL
END WALL OPENINGS POST/RAFTER FRAMING PLAN
NOT TO SCALE
TYPICAL LEAN-TO OPTIONS FRAMING PLAN (BOTH OPTIONS SHOWN)
NOT TO SCALE (BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS APPLICABLE TO BOW FRAME RAFTER)
TYPICAL BOW RR, „ LE END FRAMING PLAN
NOT TO SCALE I :, - Q f' 4w'ilAND ALL ppop r r
,
k' �. �
�'-GT TO ANY Cop jC:C';
tsZzCUEaS::-:6 Sy R—FLE) Itrj, ya�y�,
q �rcCTI��-. � 1 i7.4•i
n lI AY 8Er t,jECEvL� r Eft: (���j 0 pg J
11 �C.[IIOEa���/E(i7�AsE.� �({{rrr}s�r+,r-p��t-1 )�✓
5 /•'.Y 1' uC. E Cta1Ee.Si.
SEE
TABLE 1
SHEET
1OF5-
TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN
NOT TO SCALE
nf
FULL 6" WELD
BOTH SIDES
OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOW
NOT TO SCALE
FULL 6" WELD
BOTH SIDES
OPTIONAL 24'-1" TO 30' TRUSSED RAFTER - BOX EAVE
NOT TO SCALE
1-1/2' 18 GAUGE FURRING CHANNEL FASTENED
TO EACH RAFTER WITH (2) #12-14 x 3/4' SDF
SPACED NOT MORE THAN 48' O.C.
26 GA. METAL ROOF
PANEL
RAFTER
ROOF PANEL ATTACHMENT
(ALTERNATE FOR VERTICAL ROOF PANELS)
Not To Scal\\\�,1
aoOS R
2-1/4" FOR Thomas
12 GA FRAMING Flodde Ucefjs 89 OF �-
2-112" FOR % i�=�---� n _ \
14 GA FRAMING
16 GAUGE U-CHANNEL BRACE
FASTENED TO THE POST AND
RAFTER WITH (2) #12-14 x 3/4' SDF'S
AT EACH END (4 PER BRACE)
BRACE SECTION