Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL GENERATOR
16/20/22 kW INCLUDES: FILE COPY C�Cafri-, �- • True Power'"' Electrical Technology • Two Line LCD Multilingual Digital Evolution'"" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. • Electronic Governor GENERAC° GUARDIAN° SERIES Residential Standby Generators Air -Cooled Gas Engine 1 � nk)V1 Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) -16 kW 60 Hz Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ST LUCIE COUNTI PLAN REVIEW • System Status & Maintenance Interval LED BLDG:, Indicators DATE: + • Sound Attenuated Enclosure E 1 DATF_PLUMB. • Flexible Fuel Line Connector • Direct -To -Dirt Composite Mounting Pad DATE -- • Natural Gas or LP Gas Operation MECii; • 5 Year Limited Warranty DATE__ • Capability to be installed within 18" (457 mm) of a building* FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. CLIS EDus QUIEf " Note: CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. it provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at -tI& SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are d PROTOTYPE TESTED V NEMA MGi-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC tiat'•3ss ,���, .. _ �®W *©�� Mobile,, ' PROMISE Llnk `eTONEP 4�0 h4BHA� ru • BuOnn lfla BSA.4 e—fi6 and r-1.10 pafM. 16/20/22 kW Engine • Generac G-Force design • "Spiny-lok" cast iron cylinder walls • Electronic ignition/spark advance • Full pressure lubrication system • Low oil pressure shutdown system • High temperature shutdown Generator • Revolving field • Skewed stator • Displaced phase excitation • Automatic voltage regulation • UL 2200 listed Maximizes engine "breathing".for it run cooler, reducing oil consumpti Rigid construction and added dun These features combine to assure Pressurized lubrication to all vital ing up to a 2 year/200 hour oil ch Shutdown protection prevents cat. Prevents damage due to overheati Allows for a smaller, light weight Produces a smooth output wavef Maximizes motor starting capabil Regulates the output voltage to = For your safety. GENERAC" features and benefits PEp�&Ijoned cylinder walls and plasma moly rings helps the engine )th, quick starting every time. igs means better performance, less maintenance and longer engine life. Now featur- interval. rhic engine damage due to low oil. that operates 25°% more efficiently than a revolving armature generator. for compatibility with electronic equipment. 1 % prevents damaging voltage spikes. Transfer Switch (if applicable) ` , ' _ '__".. ' • Fully automatic Transfers your vital electrical loa s to the energized, source of power. 6 NEMA 3R Can be installed inside or outsid for•maximiim sflexibility. • �;-.r • Remote mounting Mounts near your existing distn ution-panel-for simple, low-cost installation. Evolution'" Controls __...._. • `' ' • Auto/Manual/Off illuminated buttons Selects the operating mode and provides..easy;'at'-a`glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs.-of-history,'maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for pfogfaroming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints-65°A dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator Voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately minute. • Programmable exercise Operates engine to prevent oillseal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. inly • Smart battery charger Delivers charge to the battery when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and IAGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking rorif panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epo4, paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler Is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appialing installation, as close as 18" away from a building. Installation System • 1 It (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life 16/20/22 kW GENERAL° specifications Generator Model G007035-0, G007036-0, 13007038-0, G007039.0 6007042-1, G007043-1 G007037-0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19,500 Rated Maximum Continuous Load Current— 240 Volts (LP/NG) 66.6/66.6 83.3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5°% Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 00 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12Volts, Group 26R 540 CCA Mi6imum or Group 35AGM 650 CCA Minimum Unit Weight (lb/kg) 406/186 448/203 466/211 Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 638 u 732 --� Sound output in dB(A) at 23 0 (7 m) with generator operating at normal load** 66 66 67 Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test- low -speed exercise mode" 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Slid -state w/ Magneto Solid-state w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 � Starter r 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter Approx.1.9 gt/1.8 L Approx.1.9 qt/1.8 L Approx.1.9 gt/1.8 L Operating rpm 3,600 3,600 3,600 Natural Gas ft3/hr (m3/hr) 1/2 Load 218 (6.17) 204 (5.78) 228 (6.46) Full Load 309 (8.75) 301 (8.52) 327 (9.26) Liquid Propane 113/hr (gal/hr) [I/hr] 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8.99] 92 (2.53) [9.57] Full Load 106.8 (2.94) [11.11] 129.6 (3.56) [13_48] 142 (3.90) [14i77] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7" water column (7-13 mm mercury) for natural gas,10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply 10/hr x 2500 (LP) or ft3/br x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons:Aeto Automatic Start on Utility failure. 7 day exerciser. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Olt Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safely Fused/Fuse Problem Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' MaAmum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megaloule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F7 above 16 °C (60 T). 16/20/22 kW Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticki • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and AFCI breakers fr Siemens, Murray, Eaton and Square D for the most flexible and Cost eff tive install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0 - #14 2/0 - #14 2/0 - #14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connec • Rated for all classes of load,100% equipment rated, both inductive and tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and stick • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor ing flexibility. Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Width Hi H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 176.4 m GENERAC® switch options Model G007036-0 (16kW) No. of Pales 2 Current Rating (Amps) 100 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)` -Pick-up -Dropout 80°% 65°% Return to Utility* approx. 15 sec Exercises bi-weekly for 5 minutes*t Standard UL Listed Standard Total Circuits Available 24 Tandem Breaker Capabilities 8 tandems Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 *Function of Evolution Controller Exercise can be set to weekly or monthly Model 6007037-0 (16 kW)/0007039-0 (20 kW)/ G007043-0 (22 kW) No. of Poles 2 Current Rating (Amps) 200 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)* Pick-up -Dropout 60% 65% Return to Utility* approx.13 sec ^� Exercises bi-weekly for 5 minutes* Standard UL Listed Standard Enclosure Type NEMA/UL 3R Circuit Breaker Protected 22,000 Lug Range 250 MCM - #6 *Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH 16/20/22 kW GENERAC available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G007005-0 Wi-Fi LP Fuel Level Monitor itoring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & LIM Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. LEFT SIDE VIEW [4E3 ho FROM VIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENERAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000000194-F5/3/17 .Mad manag6ment GENERAL` DESCRIPTION Gerterao's Smart Power Management system Is designed to optimize the performance of a standby generator. Smart Management Modules sly. Unlike other load management systems that depend on another control aware and operate autonomously. GENERAC° ACCESSORIES Model G00w73.0 O&B USTO The system can consist of up to 8 individual device, the SMM modules are actually self - Frequency IS the true measure of generator engine performance and does not need to factor In Increased ambient temperatures, elevation changes or generator fuel type. The modules monitor the frequency (Hz) of the power being produced by Qenerac's standby generators and If It falls below a certain threshold, the module will automalloally foilowa power management algorithm to ensure that the generator Is not overloaded. The modules can be set to a load priority between 1-8 or be Sol in a lock out only mode for loads that just simply do not need to run In an oolage, therefol'e reducing the necessary size of the generator for a more cost ellective solution. $�V9N SPECIFICATIO-NS - fowerSuppliy y Source ........................................ .............................. Contactor Coll Voltage......................................................-.... ,.....,,........................................".......,..,.....,...........,..,.... _.................- ...............� ,........,. 240 VAC (from Urte input) Supported sgesour . CollVA lonish.. ................................................................................._.......,.....,.........._.,.............n......................................240 VAC CoilVA Sealed ..............................-...,...........................................................................,., .,,.-.......,,.., .......I .......... — ..... .......,..,..........................240 VAC poles.....................................................................1,........,............................................................................. 80 ................................................„.,,.,.,,...,.........................:. 6.5 Reslsllve Amps ................ ...........6.................................................. ........ F/LInductive Amps ........................ ......,.......................................................6.................. ..,.....,...,.........,................ -._......,.....................,......,..,., 2 LookedRotorAmps...................................................................................................................................................... ........,.........................................,.................,.................40 11150..............,................................................... .........-..... ........ QO EnclosureRating.....................................-........................................................6.................................................................. �...................,....,,.,........................,240Q24es .................................... ............ .......,..,..... Yes ............................... .......................................... NEMA SR "n"" GEEVERAC" s Modules GE ERAGo -.cam �m� NAM Controls (located behind the haver of tho module) C LED ONa LOAD COIMTJD PRIORITY LOokDUT LEO FLASH119 -LOAD SHED e LOADBN GENL9RATOD LED RAsHBs=somNLoOKon I ri 7 LWFLAWSSes GENLOADLOOKOUT A ®i ' I LBD OFFa ND MODULEPGWER (0 0 O rrxaicmir TEST Pdo*Dtal (1)— Sels module pr(odfy. Lockout Svhtd (B) — Praverds load IUom operating When system Is operegng under generatorpoWer Test Button (C) — Disables eanlLlor ouipul for a specified Ume. LED (D) — Provides module slalus with easy viewing through the exlemal viewing window lomled in Meupperdglit comer module. l �������, GBNerac Powei SYStems, W. o 846 W29290 HWY. 59, Walitwha, WI 53189 a gewmc.Dom �1016QencraapoweriySiems,lno Mahtsmserved.A4specfieaUomamsuh)eetbchangBvalhmdnogmBaeunOL16o0�4OS/IB/16 now UPC I SIte Selection and Preparation auction 3,,,, Sitesele di and Preparation Site Selection figure 3-9. Installeflon CleaMetces ID Description Comments EA Top of generator — t3 Front and end clearance Wrilmum oteardlstances cannot Include shrubs, bushes, ortrees. C Rear clearance 1s in (46.7 cm) minimum clearance per Shrubs, t(Murig, labeling, and flaunt, unless state or local codes dlciate otherwise. D windows and openings No operable wtndo4vs, doors, or openings in the vilall are permitted within s tt (1.62 m) from any point of the geneMW r. iin9 Weil One-hourated wafts allow closer placement of the generator set. Confirm before inatallatlon. F Removable fence Removable fence panels for senticing cannot be Piz less than 3 ft (U.9f m) In front of the generator, G overhead clearance 6 ft (f .62 m) Nnf lum distance from any structure, overhang; orpro)ections from the wall. DO NOT lnstalrunder wooden decks or structures unless this distance is matntalned. ---------------- -Installation Guidelines For 60 Hz Air-cooled Generators �� Site Selection and Preparation Install the generator set, in its protective encl( outdoors where adequate cooling and ventilating always available ; -), consider these facto ° The installation of the generator must cc strictly with ICC JFGC, NFPA 37; NFPA 54, t 68, and NFPA 70 standards, install the unit where air inlet and outlet oiler will not become obstructed by leaves, grass, si etc. If prevailing winds will cause blowing drifting, consider using a windbreak to protect unit. ° Install the generator on high ground where w,, levels will.not rise and endanger it. This unit sho not operate in or be subjected to standing water. Allow suffrclent room on all sides of the genera; for maintenance and servlcing. This unit must I Installed In accordance with any local, state, natlonai codes fat minimum distances tom othl structures. ° Clearance from the ends and front of the $eneratc must be 3 ft (0.91 m), This includes shrub. bushes, and trees. Clearance .from the back of thi generator must be a minimum of 18 in (457 mm) Clearance at the top should be a minimum of S h (1,52 m) from any structure, overhang, or projections from the wall. DO NOT install under wooden decks or structures .unless there is at least 5 ft (1.52 rn) Of clearance above the generator, Install the unit where rain gutter down spouts, roof run -Off, landscape Irrigation, water sprinklers, or SUMP pump discharge does not flood the unit or spray the enclosure, including any air inlet or outlet openings. ° Install the unit where services will not be affected or obstructed, including concealed, underground, or covered services such as electrical, fuel, phone, air conditioning, or Irrigation. This could affect warranty coverage. ° Where strong prevailing winds blow from one direction, face the generator air Inlet openings to the prevailing winds. install the generator as close as possible to the fuel supply to reduce the length of piping, R15MEMBER THAT LAWS OR CODES MAY REGULATE THE r DISTANCE AND LOCATION., in the absence of local codes regarding placement or clearance, we c recommend following these guidelines: 7 Install the generator as close as posslble to the transfer switch. RSUGMSER THAT LAWS OR k' CODES MAY REGULATE THE DISTANCE AND 71 LOCATION. in T_ The generator must be installed on a level Sur. face. The generator must be level within a 0.5 in (13 mm) all around. — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete Pad. Check local codes to see what type Is .required.1f a -concrete pad is required, all appli. cable codes should be followed, Installation Guidelines for Stationary Air -Cooled Generators NFPA 37 Is the The National Fire Protection Association's standard for the installation and use of statlonary combustion engines.. its requirements limit the spacing of an enclosed generator set from a structure or wall (!":tij17t a ""'«%). NFPA 37, Sectlon 4,1,4, Engines LoCated Outdoors: Engines, and their Weatherproof housings i6 provided, that are installed outdoors shall be located at Least 5 it (1•52 m) from openings In walls and at least 5#t (1.52 m) from structures having combustible walls. A minimum separation shall not be required where the following . conditions exist: 1. The adjacent wall of the structure has a fire resistance rating of at least one hour. 2, The weatherproof enclosure is constructed of noncombustible materials and It has been demonstrated that a fire within the enclosure will not Ignite combustible enclosure. materials outside the Annex A — Explanatory Material A41A (2) Means of demonstrating compliance are by means of full scale fire test or by calculation procedures. Because of the limited spaces that are frequently available for installation, it has become apparent the exception (2) would be beneficial for many residential and commercial Installations, UUtth that to mind, the manufacturer contracted with an Independent testing laboratory to run fUii scale fire tests to assure that the enclosure will not ignite combustible materials .outside 'he enclosure. TE: Southwest Research Institute testing approves in (457 mm) Installation minimum from structure u�a -"-*,* 0). Southwest Research Institute Is a icy. >rtally recognized third party testing and listing criteria was to determine the worst case fire scenario n the generator and to determine the Jgnitebliity of outside the engine enclosure at various distances. enclosure is constructed of non-combustible dais, and the results and conclusions from the endent testing lab Indicated that any fire within the 12 Installation G3uldeline<s Site Selection and Preparation generator enclosure would not pose any ignition risk to nearby combustibles or structures, with or without fire service personnel response. 16aa 7 btasaute snn %% Tam �"'�'� hbie 1 lso � "•,�, H E a IM a MM41oMMM%.� MMatoMRu•�. M M 8 in CfiAR R4 m Figure 3-2 Southwest Research Institute MarMng Based on this testing and the requirements of NFPA 37, Sec 4.1:4; the guidelines for installation of the generators listed above are changed to 15 in (457 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and ainjow, clearance, the area above the generator should be at leas# 6 fi (1,52 m) with a minimum of 3 it (0.91 m) at the front and ends buof the enclosure. This includes trees, shrubs, and shes. Vegetation not In compliance 'with these clearance parameters could. obstruct air flow. In addition, exhaust fumes from the generator could Inhibit .plant growth` See aura &Y and the Installation drawing within the ofter's manual for details. f e Automatic start-up. Disconnect utility power and render unit Inoperable before working on unit. Failure to do so will result In death or serious injury. (000191) a Asphyxiatlon. Running engines produce carbon monoxide, a colorless, odorless, poisonous as. Carbon monoxid if ° Site Preparation ° Locate the mounting area as close as possible t the transfer switch and fuel supply. ° Leave adequate room arourid the area for servlct access ,(check focal code), and place high enougf to keep rising water from reaching the generator. e Choose an open space that will provide adequate and unobstructed airflow G Place the unit so air vents won't become Clogged with leaves, grass, snow, or debris. Verify that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air Intakes (see x[a 83;r Select the type of base, such as ---but not limited to —compacted soil, gravel, or concrete, as desired or as required by local laws or codes. Verify, your local requirements before selecting. Mafierlai Sufficlent for Level installation Prepare a rectangular area approximately 5 In (127 mm) deep (A) and approximately B In (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted Is compacted, leveled, and vvi11 not erode over time. A concrete pad can be Poured if desired or required. i` �1 f l 1/.ram.._ „'�f ✓ Figure 3-3 Compacted Soil or Gravel Pad avoided, wil[ result In death or seerlous IoOnjary NOTE: If a concrete pad Is required, follow all applicable ( 00103) federal, state, or local codes. NOTE: if the generator is not set to OFF, ;tt can crank and start as soon as the battery cables are connected. if the Utility power supply Is not turned off, sparking can occur at the battery posts and cause an explosion. --�--- InsfallaHnn nld.J..uw__ r.....,, .. i u r14,wf--vooiea venerators is