EVALUATION REPORT
THESE PLANS AND PRtOPOSED)NORK
ARE SUBJECT `i O AIjdY CORRECTIONS
REOUIREI) DY FIELD INSPECTORS THAT
MAY DE NECESSARY IN ORDER TO
comPLY WITH ALL A 11LICA,ULC CODE$'
EXTERIOR RESEARCH & DESIGN, LLC.
�, Certificate of Authorization#9503
SCANNED
�y 353 Christian Street
BY oxford, Cr 06478
Ct LUCIE) COU11 / (263) 26-2-9245
Polyglass USA, Inc. Evaluation Report P9290.-02-08-R20
150 Lyon Drive F1.1654-1122
Fernley, NV 89408 Date of Issuance: 02/11/2008
(576) 384-1230 Revision 20: 09/12/2017
SCOPE:
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th'Edition (2017) Florida. Building Code sections noted herein.
DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems
LABELING: Labeling shall be in, accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named products) changes, the referenced
Quality Assurance documentation changes, or.provisions of the Code that -relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the, referenced Quality Assurance documentation changes: Trinity ERD requires a complete review of this
Evaluation Report relative to updated ,Code requirements with each Code Cycle:.
ADVERTISEMENT: The Evaluation Report number preceded by the words. `Trinity I ERD Evaluated" may be displayed in
advertising -literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this .entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and, shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6, plus a 58-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
'��o�^v, aL The facsimile seal appearing was authorized by Robert Nieminen,
:.Jb4nnsn�
P.E. on 09/12/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research, & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will. it acquire; a financial interest
in any company manufacturing or- distributing products it evaluates.
Z. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
B. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert.Nieminen, P:E. does not have, nor will acquire; a financial Interest in any other entityInvolved In the approval process of the
product.
S. This -is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are; In any way, the Designer of Record for any
project on which; this Evaluation Report, or previous versions thereof, is/was used for permitting Or design guidance unless retained
specifically for that purpose.
CONCEALED FASTEN�AS OR ATf ACHMENTS
AAE THE PESPONSI91LIfY OF THE
CONTflACTOA OF fl�fAAA I
L FLC.
I
Q� TRINITY I ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category.: Modified Bitumen Roof Systems
Compliance Staterrient: Polyglass SBS and, APP Modified Bitumen Roof Systems, as produced by Polyglass USA,
Inc., have demonstrated compliance with the following sections of the 6ei Edition (2017) Florida Building Code
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind
FM 4474
2011
1504.3.1
Wind
UL 1897
'2012
1504.7
Impact
FM 4470
2612
1507.11.2
Physical Properties
ASTM D6162
2008
1507.11.2
Physical Properties
ASTM I)6163
2008
1507.11.2
Physical Properties
ASTM D6164
2011
1507.11.2
Physical Properties
ASTM D6222
2011
1507.11.2
Physical Properties
ASTM D6509
2009
3. REFERENCES:
Entity
Examination
Reference
Date
ERD (TST6049)
Physical Properties
P10490.10.08-2
10/30/2008
ERD (TST6049)
FM 4470/4474
P13760.09.09
09/10/2009
ERD (TST6049)
FM 4470/4474
P13770.09.09
09/10/2009
ERD (TST6049)
FM 4470/4474
P30540.11.09-111
11/30/2009
ERD (TST6049)
FM 4470/4474
P30550.12.09
12/02/2009
ERD (TST6049)
Physical Properties
P33960.12.30
12/30/2010
ERD (TST6049)
FM 4470/4474
P33970.03.11
03/15/2011
ERD (TST6049)
Physical Properties
P37590.03.13-3A
03/06/2013
ERD (TST6049)
FM 4470/4474
P39680.03:13
03/04/2013
ERD (TST6049)
Physical Properties
P37590.03.13-1-R1
06/26/2013
ERD (TST6049)
Physical Properties
P37590.03.13-2-R1
07/01/2013
ERD (TST6049)
Physical Properties
P37590.07.13-2
07/01/2013
ERD (TST6049)
Physical Properties
P37590.03.13-5-R1
07/01/2013
ERD (TST6049)
Physical Properties
P37590.07.13-1
07/02/2013
ERD (TST6049)
FNI4470/4474
P4.1630.08.13
08/06/2013
ERD (TST6049)
Physical Properties
P45940.09.13
09/04/2013'
ERD (T5T6049)
Physical Properties
P44370.10.13
10/04/2013
ERD (TST6049)
Physical Properties
P39520.09.14-2
09/11/2014
ERD (TST6049)
FM 4470/4474,
SC6160.11.14.
11/10/2014
ERD (TST6049)
Physical Properties
PLYG-P45440SC.03.15-1
03/31/2015
ERD (TST6049)
Physical Properties
SC5170.05.15
05/08/2015
ERD (TST6049)
FM 4474
SC8085.05.15
05/19/2015
ERD (TST6049)
Physical Properties
SC5170:12.15
12/29/2015
ERD (TST6049)
FM 4470/4474
SC9455.15
04/01/2016
ERD (TST6049)
FM 4410/4474
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST6049)
FM 4470/4474
PLYG-5C8905.05.16-2
05/17/2016
ERD (TST6049)
FM 4470/4474
PLYG-SC10815.07.16-R1
09/23/2016
ERD (TST6049)
UL1897
PLYG-SC12025.10.16
10/12/2016
ERD (TST6049)
FM 4470%4474
PLYG-SC11475.16
11/17/2016
ERD (TST6049).
FM 4470/4414/UL1897
PLYG-SC13235.01.17
01/17/2017.
ERD (TST6049)
FM 4474/UL1897/TA4 114
PLYG-SC13926.05.17
05/30/2017
ERD(TST11294)
FM 4474/ULla97/TAS 114
PLYG CTL13945.05.17-1
05/30/2017
Exterior Research and Design,,.LLC.
Evaluation Report P9290.02.08-R20
Certificate ofAuthoriradon N9503
67H EDITION (2017) FBC NON-HVHZ EVALUATION
FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Revision 20: 09/12/2017
Page 2 of 6
`J TRINITY I ERD
Entity
Examination
Reference
Date
ERD (W11294)
FM 4474/UL1897/TAS 114
PLYG-CTL13945.05:17.-3
05/30/2017
ERD (TST6049)
FM 4474/uL1897'
PLYG-SC13945.05.17
05/30/2017
ERD (7Sf6049)
FM 4474/TAS 114
PLYG-SC15760.09.17
09/11/2017
W.Approvals (TST1867)
FM 4470
2W7A7.AM
08/04/1994
FM Approvals (TST1867)
FM 4470
OD3A3.AM
04/04/1997
FM Approvals (TST1867)
FM 4470
2DOAO.AM
12/23/1998
FM Approvals (TST3867)
F.M 447.0
2D5A9.AM
05/22/1999
FM Approvals (TST1867)
FM 4470
3006646
01/04/2000
FM Approvals (TST1867)
FM-4470
30.01334
01/25/2000
FM Approvals (TST1867)
FM 4470
3001334
'02/15/2000
FM:Approvals (TST1867)
FM 4470
3000857
03/12/2000
FM Approvals (TST1867)
FIVI 4470:
3004091
01/12/2000
FM Approvals (TST1867)
FM 4470
3006115'
05/02/2001
FM Approvals (TST1867)
FM 4470
3012321
07/29/2002
FM Approvals (TST186
F4470•
08/05/2003
FM.Approvals (TST1867)
FW4470
3.014751
08/27/2001
FM Approvals (TST1867)
FM 4476'
3007170
01/13/2064
FM Approvals (TST1867)
FM 4470
30i9317
06/30/2004
FIVI.Approvals (TST1867)
FM 4470
3020703
07/30/2004
FM Approvals (TST1867)
FM 4470/4474
3018332
01/31/2006
FM Approvals (TST1867)
FIVI,447.0/4474
3023368.
03/20/2006
FM Approvals (TST1867)
FM 4470/4474
30,24594
05/23/2006
FM Approvals (TST1867)
FM 4470/,4474
3023458
67/18/2006
FM Approvals (TST1867)
FM 4470/4474
3030668
09/12/2007
FM Approvals (TST1867)
FM 4470/4474
30A2172
06/12/2009
F.M Approvals (TST1867)
FM 4470/4474
3049631
64/21/2014
FM Approvals (TST1867)
FM 4470/4474
3057029
02/02/2017
PRI (TST5878)
Physical Properties
PUSA-062=02-01
12/04/2007
PRI (TST5878)
Physical Properties
PUSA-061-02=02
01/28/2008
PRI,(TST5878),
Physical Properties
PUSA-064-02-02
02/27/2008
PRI (TST5878)
Physical Properties
PUSA-062-OM2
12/04/2008
PRI (TST5878)
TAS 214
PUSA-188-02-01
02/08/2017
;PRI (TST$878)
TAS 114
PLIM488-02-02
02/08/2017
PRI (TST5878)
TAS 114.
PUSA7188-02-03
02/08/2017
PRI (TST5878)
TAS 114
PUSA-202-02-01
05/171201.7
PRI (TST5878)
TAS 114
PUSA-201-02-02
65/17/2017
Miami -Dade (CER1592)
HVHZ Compliance
Various NOAs
Various
Miami=Dade (CER1592).
Proposal for Review
10-0823
10/12/2010
uL LLC (C1UA9625);
Quality Control,
Service Confirmation, R14571
Exp.10/06/2018
4. PRODUCT DESCRIPTION:
This Evaluation Report covers. Polyglass Modified Bitumen Roof Systems installed1n accordance,With Polyglass USA,
Inc, publishedr installation instructions and the Limitations / Conditions, of Use 'herein: The following Polyglass
membranes make up the subject.systems.
TABLE 1: ROLL -GOODS FOR PQLYGLASS`MOOIFIED BITUMEN,ROOF SYSTEMS
Type
Product
Specification
Reference
Grade
Type.
Base Sheets
Polyglass G2 Base
ASTM D4601
N/A
II
' Polyflex SA Base
ASTM D4601
N/A
II
Polyglass APP Base
ASTM"D6509
N/A
N/A
Exterior Research and Design; LLC. EYaluation.Report P9290.02.08-1120
Certi leate.of Authorization 49503 e" EDITION (2017),FBC NON-HVHZ EVALUATION FL36541122
Polyglass Modified Bitumen Roof Systems; (570)3844230 Revision20:69/12/2011
Pagel of 6
FYD
,I TRINiII'�ERD
TABLE 1,(OONTINUED): ROLL-GOODSFOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS
Type
Product
Specification
Reference
Grade
Type
SBS Membranes
Polyglass HT Base 650
ASTM D6162
S
III:
Elastobase
ASTM D6163
S
I.
ASTM D6163
S
I:
MMiP���
ASTM D6163, Table 2
S
1'
ASTM D6163, Table 2
S.
ElastoflekSA V Plus
ASTM D6163
S.
1
Elastoflex SA V Plus FR
ASTIVI D6163
S
I
Elastobase Poly.
ASTIVI D6164
5
1' .
Elastoflex S6,
ASTM D6164
S
Elastoflex S6 Type II
ASTM D6164
5
II
Elastoflex VG
ASTM'D6163
G
i
Elastoflex VG FR
ASTM D6163
G
I. _
SBS Membranes-
Elastoflex S6 G
ASTM D6164
G
Elastoflex S6.G FR
ASTM D6164
G
I
Polyfresko G SBS (sand or poly -film backed)
ASTM D6164-
G
1
Polyfresko G SBS FR,(sand or poly -film backed)
ASTM D6164
G
I
Elastoshield:TS G
ASTM D6164
G
Elasto'shield TS'G FR
ASTM D6164
G
I
Elastoflex SA P
ASTM D6164
G
Elastoflex SA P FR
ASTM D6164
G
I
Polyreflect
ASTM D6164
S
I
APO Membranes
Polyflex
ASTM D6222
S'
Polyflex G
ASTM D6222
G
I
PolyflexG FR
ASTM D6222
G
Polyfresko G
ASTM D6222
G
1
Polyfresko G FR .
ASTM D6222
G
Polybond
ASTM D6222
S
I
Palvbond G
ASTM D6222
G
I
Polvflex SA P
ASTM D6222
G
Polyflex SA PTR
,ASTM D6222
G
I
Polyfre'sko G SA
ASTM D6222
G
I
Polykool
ASTM D6222
S
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity-JERD nor Robert Nieminen, 'P.'E. are, in any way, the
Designer of Record for any project on ,which this Evaluation Report,. or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5:2 This Evaluation Report is not for use in FBC HVHZ jurisdictions..
5.3 Refer to a current Approved Roofing Materials Directory for fire ratings.of this product.
5:4 For steel deck installations, foam plastic insulation shall beseparated- from..the building interior in accordance
with FBC 2603.4 unless the exceptiorts.stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The; roof system evaluation herein pertains to above=deck roof components. Roof decks ,and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction: Load resistance of the roof deck shall be docurn6fited through proper codified and/or FBC
Approval documentation.
5.6 For recover installations, the existing roof shall be -examined in accordance with FBC 1511.
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-1120
Ceitif7cgte of, Authoriration #9503, 6EDITION (2017) FOC NON-HVH2 EVALUATION 01.1654-R22
Polyglass Modified Bitumen Roof Systems; (570)_3N-1230 Revision 20: 09/12/2017
Page 4 of 6
QQ
TRINITY I ERD
5.7 For mechanically attached insulation or:membrane or strip -bonded insulation, the maximum design pressure
for the selected assembly shall. meet or exceed the Zone 1 design pressure. determined in accordance with
FBC Chapter' 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSi/SPRI WDl, FM Loss
Prevention Data Sheet:1-29, Roofing Application Standard RAS 117• and Roofing Application'Standard RAS
131. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1. of FM Loss -
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5A For assemblies .with all components fully ,bonded in place, the maximum. design pressure for the selected
assembly shall meet or exceed critical d'esign,pressure determined In accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be -tested in the
existing deck for withdrawal resistance: Xqualified design professional shall review the data for comparison'
to the minimum requirements for the system: Testing and analysis shall be in accordance with ANSI/SPRI
11-1 or Testing Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off)* or recover installation, the
existing deck or existing roof surface shall be examined for compatibility with the adhesive;to be installed. If
any surface conditions exist that bring rsystem performance'into question, field uplift testing. in accordance
with ANSI/SPRI IA-1, ASTM E9071 FM -Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS
124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane ,over existing substrates in,.a recover installation, the existing roof
system shall be capable of resisting project design pressures on Its own merit to the satisfaction of the
Authority Having Jurisdiction; as documented through field uplift testing in accordance with ASTM E907, FM
Loss. Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5:12 Metal edge attachment (except gutters),, shall be designed and installed for wind loads in accordance with
FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-T or Roofing Application Standard
RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2), or
1609.3(3).
5.13 All ,products in the roof assembly shall have qualityassurance in accordance with FAC Rule 61020-3.
6. INSTALLATION:
6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
61 System attachment requirements for wind load resistance are set forth in. Appendix 1. "MDP" = Maxirnum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure, divided by 2 (the 2. to, 1 margin of safety per FBC 1504.9 has already been.
applied). Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, LLC. Evaluation Report P9290.02.08-1120
Certijlcate of Authorizadon #9503 6P EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof.Systems; (570) 384-1230 Revision 20; 09/12/2017
Page 5 of 6
VFW
TRINITY + ERD
6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect
on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated
with coating usage.
PG200 Non-Fibered Roof Coating;
➢ PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating;
➢ PG700 High'Quality Elastomeric Roof Coating or KM Acryl 25;
➢ PG700QS (Quick -'Set) High Quality Elastomeric Roof Coating, or KM Acryl 25-QS (over granule -surfaced
APP or SBS only);
PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Non-Fibered Aluminumn Roof Coating;
➢ Polyplus 65 Premium fibered`Aluminum Roof Coating;
➢ Polybrite 70 Premium. Grade Elastomeric Roof Coating or KM•Acryl 15;
➢ 'Polybrite70QS.(Quick-Set) Premium Grade Elastomeric Roof Coating or KM Acryt15-QS (over granule -
surfaced APP or SBS only);.
➢ Polybrite 90 High Solids Silicone Roof Coating;
➢ Polybrite 95 Silicone Roof Coating.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building. Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
B. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA
requirements
9. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com
- THE 58-PAGES THAT FOLLOW FORM PART OF THIS -EVALUATION REPORT -
Exterior Research and -Design; U.C. Evaluation Report P9290.02.08-820
eert#7cate.ofAuthorization #9503 6P EDITION (2017) F.BC NON*VHZ EVALUATION FL1654-R22
Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017
Page 5 of 6
I
IN N-1
,-J TRINITY I ERD
TABLE 1F-2: WOOD DECK 5=NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER
SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER
Base Sheet
Roof -Cover.
(Note 15).
MOP
System
No.
Deck (Note 1)
(psf)'
Type Fasten Attach
Base Ply Cap
SELF -ADHERING BASE PLY:
---
Min.'19/32-
_
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8 with Dekfast #14
)
12-inch o.c. in 4-Inch lap and 12-Inch o.c. in two
SBS-SA
SBS-SA, AP,P=SA, SBS-
-52.5
W.-136
inch plywood
(poly -film top)
orTrufast 3" Metal insulation Plate with'Trufast HD
(2),,equally spaced, staggered center rows
TA, APP TA'
'Min.19/32-
Elastobase; Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14
124nch o:c. in 4-Inch lap and'12-inch o.c-,In two
Poly flex SA Base
APP TA
-52.5•
-W-137
Inch plywood
(poly -film top)
or Trufast 3° Metal Insulation Plate with Trufast HD
�(2);equallyspaced staggered center rows
W-138
Min.19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip #12
;2-inch o.c. In 4-Inch lap and 127inch o.C.In two
staggered center rows
SBS-SA
TA, AAPP-TA , APP-SA, SBS-.-60.0•
T A,
Inch plywood
(poly -film top)
(2), equally spaced;
W-139
Min.19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates.(sguare) with Roofgrip t{12
12-inch o.c. In 4-Inch lap and 12-Inch o.c. In two
(2), equally.-spaced,'staggered center rows
-
pof ex SA Base
APP TA
-60.0•
Inch plywood
'(poly-filmtop)
TABLE 16: WOOD DECKS" NEW CONSTRUCTION OR REROOF (TEAR -OFF)'
SYSTEM TYPE F: NON -INSULATED; BONDED ROOF COVER
System
,Roof Cover (Note 15)
MOP
Joint Treatment,
Base Ply -
Ply
Cap Ply(psf)
Deck (Note 1)
Primer
Min.
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-g0.0
W440
Inch plywood
Inch
None
None
TA, AP.P-TA'
TA, APR TA
W-141
Min.15/32-
(Optional) PGS00
None
Polyflex SA Base
(Optional) APP-tA
OP -TA
-90.0
inch plywood
Min..15/32-
SBS-SA
(Optional) SBSFSA; SBS-
SBS-SA, APP-SA, SBS-
.-91.5
W-142
inch plywood
PG100
'•None
TA,APP-TA
TA,APP-TA
Min. 35/32-
Plywood joints are covered with 47Inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-S PP-S SBS-
97.5
W-143
Inch plywood
(Optiohal).PG100
place to create continuous bond.
Elastof ex SA Base
TA, APP-TA
TA, APP-TA
W-144
MIn.15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA,APP-SA;SBS-
TA,'APP-TA
_305.0
Inch plywood
Min.15/32-
Plywood joints'are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled Into
Elastoflex SA V Plus or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-135.0
W-145.
Inch plywood
(Optional) PGlI)0
place to create continuous bond.
Elastoflex SAV Plus FR
TA, APP-TA.
TA, APP TA
Min..l5/32-
Plywood Joints are covered with 4-Inch wide strips of Elastoflex SA V Plus, rolled into
poly0ex SA Base
(Optional) APP TA
APP-TA
135.0'
W-146
Inch plywood
(Optional) PG100
place to create continuous bond.
Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R20for FL3064,1122
Certificate of Authorization #9503 bin EDITION (2017) FBC NON-HVHL EVALUATION Revision 20: 09/12/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1, Page 21 of 58