Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING TILES1/30/2018 Florida Building Code Online SCANNED BYnumbs St Lucie. �6/ - BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts Publications I FBC Staff I BCIS Site Map I Links I Search Florida pr i Product Approval j USER: Public User b�ivxxlupr..� G*.tlF'�„�AGb7 Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL7473-R8 Im Revision 2017 Approved 0 EAGLE ROOFING PRODUCTS FLORIDA LLC 1575 East CR 470 Sumterville, FL 33858 (800)400-3245 annettes@eagieroofing.com Annette Sindar annettes@eagleroofing.com Tyler Allwood 1575 East Country Road 470 Sumterville, FL 33585 (941)302-7826 tylera@eagleroofing.com Roofing Roofing Tiles /,fU/- : '7C6 ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM L CE REVIEWED BY DATE PLANS AND PER IT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 Architectural Testing, Inc. 12/31/2020 John W. Knezevich, PE O Validation Checklist - Hardcopy Received FL7473 R8 COI 2017 01 COI Nieminen.pdf Standard Year ASTM C1492 2009 FRSA/TRI April 2012 2012 SSTD 11 1997 Sections from the Code https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt8Bwwt9vllPtVBTji°/`2f7gT7a%2fuMUFZfllM%3d 1/2 x 1/30/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 10/16/2017 10/18/2017 10/19/2017 12/12/2017 FL # Model, Number or Name Description 7473.1 Eagle Roof Tiles Low (flat), medium and high profile concrete roof tiles Limits of Use Installation Instructions Approved for use in HVHZ: No FL7473 R8 II 2017 10 FINAL ER EAGLE NON - Approved for use outside HVHZ: Yes HVHZ FL7473-R8.Ddf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: See Section 5 of Evaluation Report for Limits of Use. Evaluation Reports Tile roofs are analyzed for wind resistance through overturning FL7473 R8 AE 2017 10 FINAL ER EAGLE NON - HVHZ FL7473-R8.pdf moment. Refer to FRSA/TRI 07320 for overturning moment limitations of mechanically attached tile systems and the tile Created by Independent Third Party: Yes adhesive manufacturers' Product Approvals for adhesive set tile systems. Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1F 3 ® RE Cfedit 9 Safe securit��;`irmics• I hfps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt8Bwwt9vllPtVBTji%2f7gT7a%2fuMUFZfl1M%3d 2/2 �! I KINIIY ERD EVALUATION REPORT Eagle Roofing Products Florida LLC. 1575 East Country Road 470 Sumterville, FL 33585 (800) 400-3245 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203) 262-9245 Evaluation Report E1322.09.06-R5 FL7473-R8 Date of Issuance: 02/24/2009 Revision 5:10/16/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6ch Edition (2017) Florida Building Code (NON-HVHZ) sections noted herein. DESCRIPTION: Eagle Roof Tiles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Evaluated by Robert Nieminen, P.E." may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 20/16/2017. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinity lERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. F)(D TRINITY ERA ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Eagle Roof Tiles, as produced by Eagle Roofing Products Florida LLC, have demonstrated compliance with the following sections of the I th Edition (2017) Florida Building Code (NON-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5, R905.3.5 Physical Properties ASTM C1492 2003(2009) 1507.3.7, R905.3.7 Attachment Requirements FRSA/TRI April 2012 (04-12) 2012 1504.2.1.1 Overturning Moment SSTD 11 1997 3. REFERENCES: Entity Examination Reference Date ATL (TST 3782) ASTM C1492 RT0310.01-17, 02-17, 03-17 03/15/2017 ATL (TST 3782) ASTM C1492 — Freeze/thaw RT0706.01-17, 02-17, 03-17 09/25/2017 Tile Roof Institute SSTD 11 Membership Letter 11/29/2005 ATI (QUA 1844) Quality Assurance Inspection Report 06/07/2017 4. PRODUCT DESCRIPTION: 4.1 ASTM C1492, Type. III (Low Profile): BEL AIR, Exterior Research and Design, I.I.C. a EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-R5 Certificate ofAuthori:ation N9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-118 Revision 5:10/16/2017 Page 2 of 5 4.2 4.3 I. ASTM C1492, Type I NAIL HOLE !): I CAPISTRANO F)o I ERD S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck) or listing by an approved testing agency for fire rating of this product. Underlayment shall be that which holds Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set the roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 5.5 "Color -Bonded" or "Slurry -Coated" files are limited to use on projects in areas subjected to weathering indices of 50 or less (negligible weathering), as outlined in Figure 1 of ASTM C1492-03(2009)', reproduced below for reference. This limitation does not apply to the "Color -Through" product offering. 50 50 50 X. WEATHERING REGIONS � 'NEGLIGIBLE WEATHERING 177-1 MODERATE WEATHERING SEVERE WEATHERING 5.6 All products in the roof assembly shall have quality assurance audit in accordance with FAC Rule 61G20-3. Exterior Research and Design, I.I.C. C' EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-RS CertijicateojAuthorirotion #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8 Revision 5: 10/16/2017 Page 3 of 5 • I TRINITY I ERD 6. INSTALLATION: 6.1 Eagle Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual. 6.2 Underlayment shall be installed in accordance with FRSA/TRI April 2012 (04-12) or the underlayment manufacturer's current Product Approval. For mortar -set or adhesive -set tile roofing applications, the underlayment current Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 6.3 Tile Attachment: 6.3.1 Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 213 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3. 6.3.2 Mortar -Set Tile: Wind load resistance shall be in accordance with Table 2A or 26 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the mortar manufacturer's Product Approval. 6.3.3 Adhesive -Set Tile: Wind load resistance shall be in accordance with Table 2A or 213 of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current version of the referenced Florida Product Approval for paddy -placement details and performance data. TILE ADHESIVES FOR ADHESIVE -SET TILE SYSTEMS Manufacturer Products Florida Product Approval DAP Foam, Inc. "Touch N' Seal Storm Bond" FL14506 'Touch N' Seal Storm Bond 2" FL21374 Dow Chemical `TILE BONDTM" FL22525 ICP Adhesives & Sealants, Inc. "Polyset® AH-160" FL6332 "Polyset® RTA-1" FL6276 6.3.4 Hip and Ridge Tile: Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installations atop hip and ridge metal, refer to the hip and ridge metal manufacturer's current Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12). Exterior Research and Design, I.I.C. 6' EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-115 Certificate of Authorization #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-RS Revision 5: 20/16/2017 Page 4 of 5 @i a C)o '-1 TRINITY I ERD 7. LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. EAGLLE,�' FLORIDA EAGLE FL (LOCATED O\ UNMERSIDE OF ME) (LOCATED ON FRONTSIDE OF TILE) 7.2 Tile not tested for freeze -thaw shall state clearly that the lot has not been tested for freeze -thaw acceptance on all lot tags or certification. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Sumterville, FL 10. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc. — QUA1844; (717) 764-7700 - END OF EVALUATION REPORT - ' ASTM C1492-03, Standard Specification for Concrete Roof Tile,© ASTM International Exterior Research and Design, I.I.C. 6' EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-R5 Certificate of Authorization #9503 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-R8 Revision 5:10/16/2017 Page 5 of 5