HomeMy WebLinkAboutLIMITED WARRANTY�4 ��' 9O
7-30
LISADEn SYN ETIC F'�`
UNDERLAYMENT „�;�,iLYEARil'`'ii`''
- 30 YEAR LIMITED WARRANTY
OWNER: NAME ADDRESS
PHONE EMAIL
ADDRESS OF BUILDING
•-------------•------•-••--------•--•-•--•-.......-•--•--••.--...-----.......-•---•----•-...................--............
ROOFING APPLICATOR: NAME ADDRESS
PHONE EMAIL
DEALER: NAME ADDRESS
PHONE EMAIL
DATE OF UNDERLAYMENT INSTALLATION: PRODUCT PRODUCTION DATE CODE (PRINTED ON SURFACE)
LIMITED WARRANTY
SDP Advanced Polymer Products Inc (the manufacturer) warrants to you, the original ownerthat SOP will reimburseyou in accordance with this warranty U PALISADER'
(the product) falls to shed water as a result of a product manufacturing defect
This warranty extends for the 30 years from the data of product installation. THIS WARRANTY IS NOT TRANSFERABLE OR ASSIGNABLE The warranty period starts at the
completion of installation of the product and terminates ft either the product or the overlying roofing materials are replaced or if the building Is sold or transferred.
The above warranty does not apply H the product has been installed and left uncovered for a more than six (6) months, or 9 any par of the product is exposed to UV after
primary roof installation. The wami* does not cover leaks or damage caused by severe weather conditions prior to primary root installations, nor to leaks through any
penetrations, Including fasteners.
This warranty shall become VOID, If anyone not expressly authorized by manufacturer performs arty repairs or alterations within the period of this warranty or U owner fails
to give notice of defect within the period set out above.
EXCLUSIVE REMEDIES
Forany portion of the pmductffat fails to shed wateras a result of a manufacturing defect, the manufacturer Will provide you with replacement product or refund original
purchase price, excluding labor and any costs Involved with repairing or replacing substrate, overlying roofing materials, or any other roofing system related product
Decisions as to the extent of repair or replacement required will be made solely by the manufacturer. The remedy under this warranty is available onlyfor that portion of
your product exhibiting defects at the time of settlemerflL The replacement material as well as any remaining original product will be warranted only for the original warranty
period.
LIMITATIONS ON COVERAGE
The manufacturer will NOT be gable for and this warranty does NOT apply to:
1. Damage to the product or roof or leaking to the interior of your building resulting from anything other than an Inherent manufacturing defect in the product, such as:
a) Leaks through any penetrations or fasteners.
b) Subsequent structural changes or alterations to your roof, such as installation of equipment on your roof (for example, solar heating or air conditioning
equipment or TV antennas).
c) Settlement, movement or defects in the building, walls, foundation, roof deck, or materials used as a roof base over which the leak barrier was applied.
2) Damage to the product or leaking to the interior of your building resulting from causes such as:
a) Acts of nature, such as hail, storms, or winds or
b) Improper storage or handling of the product.
3) Damage resulting from the application of overlying roofing materials.
4) Laboi costs
5) Third party testing or transportation costs.
WHAT YOU MUST DO
To file a claim under this Warranty, you must send a notice of claim in writing, togetherwith proof of purchase to establish that you are the original owner, pproof of applicaton
!in
llatiDhre ft in accordance vnth the terms of thfs warranty. You should have this wanamy certiflcate signed and dated by your contractor or dealer te help establish proof of
In.rchase and minted intotmadon. You should retain this certrficate for your records in the event you need to file a claim.
SOLE AND EXCLUSIVE WARRANTY
THIS WARRANTY IS EXCLUSIVE AND REPLACES ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE This written warranty is your exclusive warranty from the manufacturer and represents the SOLE REMEDY available to any
owner of the product The manufacturer makes NO OTHER REPRESENTATIONS OR WARRANTY of any kind other then that stated herein. The manufacturer WILL NOT BE
LIABLE IN ANY EVENT FOR'CONSEOUENTIAL, INDIRECT OR INCIDENTAL DAMAGES OF ANY KIND, including DAMAGE TO THE INTERIOR OR EXTEHIOR OF ANY BUILDING
whether for breach of this warranty, negligence, strict ilability In tort, or for anyother cause. Some slates do not allow the exclusion or limitation of incidental or consequemiai
damages so the above exclusions or limitations may not apply to you.
MODIFICATION OF WARRANTY
This Limited Warranty may not be changed or modified except in writing signed by an officer of the manufacturer. No one, Including any representative or employee of the
manufacturer, has authority to assume any additional liability or responsibility for the manufacturer in connection with the product except as described In this Warranty.
This Warranty gives you specific legal fights, and you may have other rights, which vary from state to state.
EFFECTIVE DATE
This Limited Warranty is effective for product installed within the continental United States and Hawaii after January 1,
V] r3D P SDP Inc. 410-130 Br idgelend Ave., Toronto, Ontario, Canada M6A 1Z4
ADVANCED POLYMER PNODUCfS Office: 866-747-4035 • Fax: 866-747-4035 • info@sdp-products.com •. scip-products.com
PALISADE TM synthetic roofing underlayment must be installed above properly ventilated spaces,
as the underlayment is considered a vapor barrier (follow all applicable building codes). The deck
surface must be 2:12 slope or greater, dry, and free of dust, dirt, voids, loose nails and other
protrusions. Damaged sheathing must be replaced. The use of a rosin paper slip -sheet is not
required underneath metal roofing systems. Installation is limited to use with roof coverings that
do not involve hot asphalt or coal -tar pitch.
PALISADETm is installed horizontally with the printed side up, and with 3-inch horizontal laps and
6-inch vertical laps. Overlaps must run with the flow of the water in a shingle pattern. The
underlayment is only attached to the roof deck with roofing nails having 1-inch minimum diameter
plastic or steel caps. USE NO STAPLES. Cap nails are spaced at 6 inches on center at vertical
laps, and at 11 inches on center at horizontal laps. In the field area, apply fasteners at 13 inches
spaced vertically and 22 inches on center horizontally. All caps (including nails) must be fully flush
with the underlayment surface. Do not install fasteners over. unsupported areas/voids. Repair
all tears, holes, or damage to the underlayment.
In coastal areas, high wind conditions, or prolonged exposure, double the fastener schedule at
minimum. (For Florida Miami-Dade/Broward High Velocity Hurricane Zones (HVHZ), see FL-
5325.1 (HVHZ) code approval). In addition, secure laps by folding all laps over before nailing,
or taping securely across lap seams using exterior grade sheathing tape, or using sealants such
as roofing cement (asbestos free meeting ASTM D4586), EPDM, or Butyl to seal laps.
For batten secured installations, use only adequate length ring shanked nails or screws. USE
NO STAPLES to secure battens to the roof deck. When battens are installed over PALISADET'",
the underlayment need only be preliminarily attached with cap nails pending attachment of the
battens or counter -battens. Layout underlayment such that cap nails will not interfere with batten
installation.
For slopes less than 4:12, use a full 20" half lap over the underlying course. Apply underlayment
up all abutments at least 6 inches.
Depending on roof pitch and surface conditions, blocking may be required to support roofing
materials. Use caution when walking on underlayment that has not been fastened to the deck.
PALISADETm is not designed to replace the primary roof covering material, or for indefinite
outdoor exposure. Final roofing must be installed within 6 months.
AS WITH ANY ROOFING PRODUCT, OBSERVE ALL SAFE ROOFING CODES & PRACTICES (OSHA Regulations, Fall Protection Systems
Criteria and Practices-1926.502). USE CAUTION WHEN WALKING OR STANDING ON PALISADE'"', AS SKID RESISTANCE MAY CHANGE
WITH WET, DUST OR FROST CONDITIONS, AND ROOF PITCH. FAILURE TO USE PROPER SAFETY GEAR AND FOOTWEAR CAN RESULT
IN SERIOUS INJURY.
I
B BUY BOT OX METALS
Rooting That Lasts
TM
M
.PAW -SAD E
SYNTHETIC ,U NDERLAYM ENT
.Palisade Synthetic Underlayment is made of iooO/6
synthetic lightweight, high-strengt h polymer.
Palisade comes in i000 sq. ft. rolls, so it covers much
more area per roll than 30 1 felt. It is 6X lighter and
delivers 30X greater tear strength than 3o lb felt.
Palisade" features Stonghold' Add resistant
technology, utilizing a highly engineered raised
surface pattern of soft resilient rubberized polymer
dots which act as grip points delivering skid resistant
- performance in wet/dusty conditions.
Toll Free 1-800-728-4010
Phone 423-479-6382
Fax 423-728-3066
www. b e stbu yrfiiiiii.i6ivi
Palisade' carries a 30 year warranty. The
underlayment you choose for your roof is like a
second layer of protection. 30 1 felt is basically
heavy paper dipped in oil. After a few years the
suns UV rays will dry this oil up and it will no
longer function as a water -barrier. Does it 'Make
sense to install a metal roof system that will
virtually last a lifetime with afelt underlayment
that may last afraction of that time?
Palisade' is part of a collection of
Industry leading Stonghold— accessories recommended for metal
Skid -Resistant Technology roofing from Best Buy Metals.
(9 A
4 UV
5
Unverified drawings often produce imperfect material quotes.
This may result in the need to purchase additional material or
higher field modification.
Measurements, slopes, pipes, chimneys, and skylights should
be verified prior to ordering.
Precise measurements are more important for cut to length
metal panels vs. metal shingles.
a
0
muul1[Dr- [King 1.0%11.1b
PIPE BOOT FEATURES - RETROFI'T
The retrofit pipe boot is designed to seal existing pipes/vents where a standard pull over flashing cannot be
assembled. The split design allows for an easy wrap around installation. Snap rivets and cable tie included.
FEATURES:
•'' WEATHER RESISTANCE
Designed to withstand the damaging effects of
ultraviolet light and ozone.
' �' MALLEABLE BASE
Designed to conform to most panel configurations
and roof pitches regardless of pipe location.
ADVANCED OZONE RESISTANCE tested to...
HIGH TEMPERATURE RESISTANCE
Tested to Intermittent
Continuous
MODIFICATIONS MADE SIMPLE
Easy to see pipe diameters make for painless on site
customization.
410 EASILY INSTALLED FASTENER
SNAPS INCLUDED
EPDM
70 hours @ 500 pphm
+2750F
+212°F
SILICONE
70 hours @ 500 pphm
+500°F
+4370F
LOW TEMPERATURE RESISTANCE tested to... -670F -101OF
COMPRESSION SET minimum... 25% 50%
*We only stock EPDM Retro-Fit boots.
Silicone Retro-Fit boots are available via special order.
(800) 728-4010
vw wbestb etals.com/st®re
Installation
9'
1.
SELECT and TRIM...
Choose appropriate Ret-
ro Fit. If necessary trim
opening to pipe diame-
ter.
3.
FORM...
Press Pipe Boot down,
bending it to conform to
roof profile or roof ir-
regularities. A blunt
tool will help press
flashing into tight roof
angles.
5.
FASTEN...
Use fasteners to com-
plete sealing. For UPC
installation, fastener
spacing should not.ex-
ceed 1-1/2" (38mm).
2.
VVR"...
Wrap Retro-Fit around
pipe and install all snap
rivets to seal flange.
4.
SEAL...
Apply sealant between
base and roof.
6.
INSTALL CABLI
TIE...
Install supplied cabl
at uppermost part of
Retro-Fit and apply
ant to any gaps.
(800,) 728-4010 wwwbestbu etals.com/store
s
Outlook Mail
.. . Search Mail and People 0 '- ' D New 1 Y- ,: `h. Reply 1 , ® Delete ' ® Archive Junk 1 Y Sweep
n Folders
Inbox
3
Junk Email
1
Drafts
1
Sent Items
Deleted Items
238
Archive
Conversation History
Upgrade to Premium
M r G
Re: roofing materials for David Dowling
RG Raven Gates <raven@ bestbuymetals.com >
® *7 Reply I v
Today, 3:52 PM
You
David,
Sorry I failed to address those questions.
On the corners, the gable rake, you'll make a flange using the top leg of
material like this:
On the area going over the back porch, if you provide photos I can
provide a better idea on how that should work If it's dropped down
16" and doesn't hit the main roof it may work completely
independently from the main roof.
Thanks,
Mrs. Raven Gates, Project Estimator / Sales Consultant
Best Buy Metals
0006. e .
Phone: (800)v28-aaio CXL 212
Fax: (42s) 728-so66
Knvw.bestbMetals.com
On Fri, Jan 12, 2018 at 3.25 PM, David Dowling <dwdow123(@hotmail.com> wrote:
Raven I have received ur estimate and really appreciate ur.quick response.
Watching all ur videos and such I am still unsure how the corners of the house are
1 to be finished with the trim and still unsure how the lower part of the panels are
going to be fastened going over the back porch. give me until Monday to go over
i this and pick a color.
Thank You So Much David Dowling
David Dowling
Remove ads
J
12" 16"
- /-CC
12" Coverage ale 16" Coverage 3�8„
Striations (standard) Striations (standard)
12" 16"
n C C
i
IJ Iai �1n
12" 'Coverage 31811 16" Coverage 3�a
Minor Ribs (available in select locations) Minor Ribs (available in select locations)
ARCHITECTURAL
-12" OR 16"
MINIMUM
RE$IDENTIAL
CO NCEALED
COVERAGE
SLOPE
PANEL
FASTENED
12°
PANEL 01%ERVIEVN
Finishes: MS Colorfast45® and Acrylic -Coated Galvalume®
Corrosion Protection: AZ55_per ASTM A 792 for unpainted Galvalume®
AZ50 per ASTM A 792 for painted Galvalume®
G90 per ASTM A 653 for Galvanized
Gauges: 26 :ga standard; 24 ga optional
12" or 16" panel coverage; V rib height
Panel Length: Minimum: 4 ; Maximum: 30' recommended (available up to 43)
Architectural, concealed direct fastened, integral standing rib roof system
Minimum roof slope: 3:12
Applies over plywood with minimum 30# felt underlayment
With Striations
TESTING AND APPROVALS „
UL 2218 Impact Resistance - Class 4
► UL 790 Fire Resistance Rating - Class A, per building code
UL 263 Fire Resistance Rating - per assembly
UL 580 Uplift Resistance - Class 90 Construction: #529
1 Texas Windstorm - Evaluation RC-162.and RC-399
2014 FBC Approvals - FL11560.4, FL11560.5 and FL14645.11
Miami -Dade County, Florida NOA 14-0107.04 expires 8/8/2018
ICC Evaluation Report - ESR-2385
With Minor Ribs (available in select locations)
.ATTACHMENT bETA1L
Image II Panel
panel Fastener
FASTEMfNG PATTERN';
SECTION PROPERTIES
Width
Yield Weight
Top In Compresslon Bottom In Compressi
Ga
in
ksi psf
lot
Smc
bot
Spot
in°/ft
in3lft
in°/ft
in3/ft
26 16
50 0.92
0.0165
0.0174
0.0165
0.0177
24 16
50 1.19
0,0210
0.0226
0.0210
0.0226
Outward Load
0.5'
1'
1.5'
2'
103
96
90
84
103
96
90
84
1, Theoretical section properties have been calculated per AM 2012 North American Specification for the Design of Cold -Formed Steel Structural Member.
Ixx and Sxx are effective section properties for deflection and bending.
s'
2. Allowable load is calculated in accordance with AISI 2012 specifications considering bending, shear, combined bending and shear, deflection and UL 580
uplift test using #10-12 Pancake Wood Screws into 5/8" plywood. Allowable load considers the 3 or more equal spans condition. Allowable load does
not address web crippling, or support material. Panel weight is not considered
3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.
4. Allowable loads do not include a 1/3 stress increase for wind