12" Coverage 31e
Striations (standard)
12"
12" Coverage 31e"
Minor Ribs (available in select locations)
16"
16" Coverage
Striations (standard)
16"
ZL n :Dn
I W Coverage 3/en
Minor Ribs (available in select locations)
ARCHITECTURAL -127 OR 16" MINIMUM.
RESIDENTIAL CONCEALED COVERAGE SLOPE, SOLID WOOD
FASTENED SUBSTRATE
PANEL . 3:12,
SCANNED
PANEL. OVERVIEW• , B St LucCounty
► Finishes: MS Colorfast45® and Acrylic -Coated Galvalume®
► Corrosion Protection: AZ55 per ASTM A 792 for unpainted Galvalume®
AZ50 per ASTM A 792 for painted Galvalume®
G90 per ASTM A 653 for Galvanized
► Gauges: 26 ga standard, 24 ga optional
► 12" or 16" panel coverage, 1" rib height
10- Panel Length: Minimum: 4 ; Maximum: 30' recommended (available up to 43)
► Architectural, concealed direct fastened, integral standing rib roof system
► Minimum roof slope: 3:12
► Applies over plywood with minimum 30# felt underlayment
With Striations
with Minor Ms (available In select locations)
TESTING AND APPROVALS
► UL 2218 Impact Resistance - Class 4
► UL 790 Fire Resistance Rating - Class A, per building code
► UL 263 Fire Resistance Rating - per assembly
► UL 580 Uplift Resistance - Class 90 Construction: #529
► Texas Windstorm - Evaluation RC-162 and RC-399
► 20144FBC_Aunrovals - FL11560.4, FL11560.5 and FL14645.1
�► Miami=Dade County, Florida NOA 140107.04 expires 8/8/2018 ,
► I v uahon Report - ESR 2385
Lr1
MIMI®DIADE
•
BUILDING DIVISION
F, ., comp
omp
REVIEWED BY
DATE
PLANS AND PERMIT
MUSTBE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
DEPARTMENT OF REG>ff0-1 Y AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
THESE PPS o ' 10.1',Li 71"OP OSED WORK
ARE SUI-�
HEQUIREi?"r'I�iP;..t►IPI;"f"rlc)P157N�f�T
MAYBE NE 0'a-68A,i i'i k 0f10C-R TO
0014FLY WiTh ALL fii�ri.lc p y
COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamidade.eov/economv
Metal Sales Manufacturing Corporation UVNUf ALED FASTENERS ON ATfACMMrtI;
545 South 3"' Street, Suite 200 ARE THE RESPONSIRILIN OF THE
Louisville, KY 40202 CONTRACTOR OF RRCORO
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Image H Metal Roofing System
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 13-0813.17 and consists of pages 1 through 5.
The submitted documentation was reviewed by Alex Tigera.
"too,, NOA No.: 14-0107.04
Expiration Date: 08/08/18
Approval Date: 02/20/14
.may Page 1 of 5
L1 L-= L_-1
ROOFING SYSTEM APPROVAL:
Cateeory
Roofing
Sub-Cateeorv:
Metal, Panels (Non -Structural)
Material•
.
Steel
Deck e:
Wood
Maximum Design Pressure 427.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Test Product
Product Dimensions Specifications Description
Image II Metal Roof L = varies' TAS 110 Corrosion resistant, galvanized, preformed,
W = I T' and 16" coated, prefinished, metal panels.
H =1"
Min. Thickness 0.019 inch
Min Yield Strength: 64 ksi.
Trim Pieces L = varies
W = varies
Min. Thickness 0.019 inch.
MANUFACTURING LOCATION:
1. Jacksonville, FL
EVIDENCE SUBMITTED:
TAS 110 Standard flashing and trim pieces.
Manufactured for each panel width.
Test Agency
Test Identifier
Test Name/Report
Date
Akzo Nobel Coatings
ASTM B 117
01/24/11
ASTM G23
01/24/12
PRI Construction Materials
VLS-005-02-01
ASTM-B 117
02/22/13
VLS-004-02-01
ASTM G 26
02/22/13
PRI Construction Materials
MSMS-006-02-01
Sealant Weathering
09/12/07
MSMS-006-02-02
11/14/07
Architectural Testing
01-43798.01
TAS 100
03/05/03
PRI Construction Materials
MSMC-005-02-01
TAS 100
06/06/07
MSMC-014-02-02
TAS 125
12/03/13
Farabaugh Engineer & Testing,
T183-05
TAS 125
08/09/05
Inc.
T241-07
TAS 125
07/23/07
E NOA No.:14-0107.04
- APPROVED Expiration Date: 08/08/18
Approval Date: 02/20/14
Page 2 of 5
APPROVED ASSEMBLIES:
System A: IMAGE II Metal Roof Panel 12" or 16" wide panel
Deck Type: Wood, Non -insulated
Deck Description: New Construction 19/32" or greater plywood or wood plank.
Maximum Uplift See Table A below.
Pressure:
Deck Attachment: In accordance with applicable Building Code, but in no case shall it be less than 8d ring
shank nails spaced 6" o.c. In reroofing, where the deck is less than 19/32" thick (Minimum
is/32") the above attachment method must be in addition to existing attachment.
Underlayment: Minimum underlayment shall be -AS�enewl
tailed with a minimum 4" side -
lap and 6" end -laps. Underlayment shalosion resistant tin -caps and 12
gauge 1 %4" annular ring -shank nails, spaced 6" o.c. at all laps and two staWK
ws 12"
o.c. in the field of the roll. Or, any approved underlayment having a curre
Fire Barrier. Any approved fire barrier having a current NOA. Refer to a current fire directory listing for
fire ratings of this roofing system assembly as well as the location of the fire barrier within
the assembly. See Limitation # 1.
Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 and
with Metal Sales Manufacturing Corporation's current published installation instructions.
Metal Panels and Install the "IMAGE II Panels" and accessories in compliance with Metal Sales
Accessories: Manufacturing Corporation's current, published installation instructions and details.
Flashing, penetrations, valley construction and other details shall be constructed in
compliance with the minimum requirements provided in Roofing Application Standards RAS
133.
Panels shall be fastened to substrate at the male end with one corrosion resistant #10 PHWS
fasteners sufficient length (but not less than 1 ") to penetrate through the sheathing a
minimum of_3/3/ib" aat a spacing not exceed 6"o.c. (See detail herein). Fasteners shall be
placed parallel to the roof slope.
TABLE A
Field
Perimeter and Corner'
Maximum Design Pressure
-102.7 psf
427.5 psf
Enhanced Fastening
None
3/8" bead of Schnee -Morehead
SM7108 adhesive in the sidejoint.
See detail herein
L lation shall not be allowed
NOA No.: 14-0107.04
Expiration Date: 08/08/18
Approval Date: 02/20/14
Page 3 of 5
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones (i.e. field, perimeters,
and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced
pressure zones (i.e. perimeters, extended corners and corners).
3. Panel shall be roll formed in continuous lengths from eave to ridge. Maximum lengths shall be described in the
Roofing Application Standard RAS 133.
4. All panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement:
"Miami -Dade County Product Control Approved" or with the Miami -Dade County Product Control Seal as seen
below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 14-0107.04
MAMI-oewe coun�rr Expiration Date: 08/08/18
Approval Date: 02/20/14
Page 4of5
PROFILE DRAWING:
IMAGE H METAL ROOF PANEL
12" or 16"
DETAIL A
#10 PHWS fasteners
16" Wide Panel
Field Condition Details
318' Bead of Schnee-
orehead SM7108
#10 PHWS fasteners
16" Wide Panel
Perimeter and Comer Condition Details
END OF THIS ACCEPTANCE
MIAMFOADE COUNTY
IIJ
NOA No.: 14-0107.04
Expiration Date: 08/08/18
Approval Date: 02/20/14
Page 5 of 5