Loading...
HomeMy WebLinkAboutEVALUATION REPORT 2-28-18IT z 1Lf oe SCANNED BY St Lucie C®u EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. 5V-CRIMP PANEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 14645.3-R3 1,06 1 -o-? 63 ROOFING ST. LUCIE COUNTY BUILD IVISION METAL ROOFING REVIEWED FOR COMP REVIEWED BY DATE Z( PLANS AND PERMIT MU T BE KEPT ON JO OR NO INSPECTION WILL BE MADE. Prepared For: :Lucie Metal Sales Manufacturigg Corporation 545South 3rd Street, Suite 200 Louisville, KY 40202 2013 Telephone: (502) 855-4300 Faz: (502) 855-4200 ST.unty, Permitting Prepared BY: Bala Sockalingam, Ph.D., g'•E' Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK92-5992 74106 Telephone (91366-1543 FAX: (866) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPWCMA 000154 CONCEUD FASTENERS ORAi1ACHMENIS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD This report consists of cover) Evaluation Report (3 Pages including Installation Details (1 gage) Report No. C2182-3 Date: 9.9.17 e`ee`oeee�eeaedoss1 SOCKAL/NU' j� �� P .;GE N 3 •.'9 'tee 0 No 62249 .cam P • Qj �� `• gTpTE OF � y •• • S. .00 O N M-� a'a e Manufacturer: Product Name: Panel Description: Materials: FL 14645.3-R3 C2182-3 9.9.17 Page 2 of 3 Metal. Sales Manufacturing Corporation 5 V-Crimp 24" wide coverage with (5) 1/2" high ribs Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 1/4" thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c. 196.75 psf @ fastener spacing of 8" o.c. Fastener Patter: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be.of sufficient length to penetrate through the deck a minimum of 3/8".. At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance -with TAS, 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing. Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/l/09 EXISTING SHINGLES (OPTIONAL) NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) SEE DETAIL 2 SEE DETAIL j NEW UNDERLAYMENT(REQUIRED ONLY FASTENER AT PANEL FLAT 5V-CRIMP (PANEL OVERLAP) NEW CONSTRUCTION)R� ` ENDSIRED ONLY.OR PANEL EXISTING UNDERLAYMENT (OPTIONAL) MINIMUM ATTACHMENT: 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED @ 6" O.C. IN THE FIELD & MIN. 2X_ WOOD RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X—SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. �— PLYWOOD DETAIL 1 19/32" THICK (MIN.) ((9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. `— PLYWOOD DETAIL 2 19/32 THICK (MIN.) PANEL FASTENER PER ALLOWABLE PRESSURE TABLE ON THIS SHEET. ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 36 41.5 16 74.8 8 196.75 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. U wN Z �-O Eno 'Zr O M LE En I zd w u� MJ� 7 N »c No