HomeMy WebLinkAboutPRODUCT APPROVAL MODIFIED BITUMENT ROOF SYSTEM1/24/2018 Florida Building Code Online
10
Regulation
..
SCANNED
Y
BCIS Home Log In I User Registrati n I Hot Topics I Submit sue
I rct0i gLdsi�I� �'blirations I FBC Staff I BCIS Site Map j Links I Search
a.
Product Approval
SERE Public User
b
Product Approval Menu > Product or A Ilcation Search > Application Ust > iI
•� RECEIVED
FL # FL16027-R2
Application Type Revision
Code Version 2017 JAN 3 2018
Application Status Approved
ST. Lucia County, Permitting
Comments �.��
? Archived 7R�EVnE�WED
CIE COUNTY
ING DIVISION
V9E�"dl� 0
Product Manufacturer Tri-Built Materials Group, LLO�,gP LIA
Address/Phone/Email PO Box 70
Rutherford, NJ 07070 DATE
(800) 516-1485 PLANS AND PERMIT
david.ruiz@tribuiltmg.com MUST BE KEPT ON JOB OR
NO INSPECTION WILL EE. MA.l7E
Authorized Signature David Ruiz
david.ruiz@tribuiltmg.com
Technical Representative David Ruiz THESE PLANS AND ALL PROPOSED WORK
Address/Phone/Email 250 Route 17 North ARE SUOJECT TO ANY CORRECTIONS
East Rutherford, N] 07073 (201)842-2449 REQUIRED BY FIELD IMPECTORS THAT
david.ruiz@tribuiltmaterialsgrWtggODNECESSARY IN ORDER TO
COMPLY WITH ALL P.I"PUCAW CODES,
Quality Assurance RepresentE Jve C Richard Schurman --
Address/Phone/Email 9050 Louisiana Street 'OF�C��LED FASTENERS OR ATTACHMENTS
Merrillville, IN 46410 r
rich.schurman@alliedbuilding.com ARE THE RESPONSIBILTY OF THE
Category Roofing CONTRACTOR OF RECORD
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect IJame who developed Robert Nieminen
the Evaluation Report CU
Florida License � PE-59166 I1Quality Assurance Entity UL LLC _PY
Quality Assurance Contract piration Date 10/06/2018
' Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL16027 R2 COI 2017 01 COI Nieminen odf
Referenced Standard and Ye (of Standard) Standard Year
ASTM D6163 2008
ASTM D6164 2011
ASTM D6222 2011
FM 4470 2012
FM 4474 2011
Equivalence of Product Standi rds -
ftps:/twww.floridi.building.org/prlpr_app_00.aspx?pa m--wGEVXQwtDgtFPmdYiNDWrxtft9YUwv%2fLXRbpak6f2jJGiyowhtbu4Q%p3d%3d 1/2
1 /24/2018
Certified By
Florida Building Code Online
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
09/30/2017
10/08/2017
12/12/2017
FL #
M
el, Number or Name
Description
16027.1
T
BUILT Modified Bitumen Roof
SBS and APP modified bitumen roof systems
Sy
ems
Limits of Use
Installation Instructions
Approved for use in HVH
No
FL16027 R2 II 2017 09 FINAL Al ER TRI-
Approved for use outside
VHZ: Yes
BUILT MODBIT FL16027-R2.Ddf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-6
2.5
Created by Independent Third Party: Yes
Other: 1.) The Design Press
ire noted in this application
Evaluation Reports
refers to one system. Refer t
ER Appendix for all systems and
FL16027 R2 AE 2017 09 FINAL ER TRI-
max. design pressures. 2.) Refer
to ER Section 5 for Limits of
BUILT MODBIT FL16027-R2.pdf
Use.
Created by Independent Third Party: Yes
Back Next
q Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/`dlflTc�n' employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses i
mall to this entity. Instead, con
455.275(1), Florida Statutes, effect
one. The emails provided may be usi
address, please provide the Departr
public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
ct the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have
for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
nt with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S.,
please click here .
Product Approval Accepts:
2/2
Table
Deck
Application
Type
Description
Page
1A-1
IA-2
Wood
Wood
New or Reroof (Tear -Off)
New, Reroof (Tear -Off) or Recover
A-2
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
4
5
1B
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
5
1C
Wood
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
6
1D
Wood
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
6
1E-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
7
, lE-2
Wood
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
s;
Wood New or Reroof
F Non -Insulated, Bonded Roof Cover
7
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
9
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
9
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover
10
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
11-14
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
14
4A
LWIC
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
15-16
48
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
16
4C
_ LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
17-19
5A
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
20
5B
CWF
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
21
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22
51)
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
22
5E
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
22
6A
Gypsum
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
23
613
Gypsum
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
24
6C
Gypsum
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
24
61)
Gypsum
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
24
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
25-26
Various
Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
26
The following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above -deck roof components.
Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall
be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-inch penetration.
➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the CIA
requirements of F.A.C. Rule 61G20-3 and is documented as meeting. FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, U.C. d/b/a Trinity ) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 6T"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26
"f 'INITY ERC
4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016).
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions.
➢ HA (HA): Full coverage at 25-30 Ibs/square.
➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced.
➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons,12-inch o.c.
➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing.
➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
➢ OMG OlyBond 500 (OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL)
➢ OMG OlyBond 500 (08500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick)
8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
l I
ii. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC
Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches.
For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC. d/b/a Trinity ) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/2S/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
1!0
Bil[LT RfJiiF CCIVERS
.
Reference
Layer
Material
Application
BP -AA
Base Ply
FBC Approved ASTM D4601, Type II
(Base and Ply sheets, Asphalt -Applied)
HA at 20-40 Ibs/square
Ply
FBC Approved ASTM D2178, Type IV or VI
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
TriBuilt SBS Granular
HA at 20-40 Ibs/square
SBS-TA
(SBS, Torch -Applied)
Cap Ply
TriBuilt SBS Granular
Torch -Applied
SBS-SA
Base Ply
TriBuilt SA SBS Base
(SBS, Self -Adhering)
Self Adhering
5*7
Cap Ply
TriBuilt SA SBS Cap
APP-TA
Base Ply or Ply
TriBuilt APP Smooth
(APP, Torch -Applied)
Torch -Applied
Cap Ply
TriBuilt APP Smooth, TriBuilt APP Granular
APP-SA
(APP, Self -Adhering)
Cap Ply
TriBuilt SA APP Cap
Self -Adhering
16. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
HARKJRBpaRrtR,Ctrrlerrrs•StRUCTURAtCoracRErEOE" '__w.Q "-. ,.. �i..
Option #
... ... ,.f ..-.no
Primer
- ,..t. ,.y >.I,R..E.. ttfN,stiu. UaT.„i'?.P.<E. Fr 6T.A.-8[E3A';a :P.i.... ., .. -:::, .:+n« �. ,.., .,., " ...
Vapor Barrier
...., ,i. . °s,_.,,,, r ,« �•,
. a $,"
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
Millennium One Step Foamable Adhesive, 12-inch o.c.
-157.5
VB-4.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-5.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20,12-inch o.c.
-290.0
-17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017
Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26
�•s
�PEE�NfiR1=iN5Ut.ki'�'E[3 NlECH1�N1 AL'GY
, �_ ya�':SXSTEi41`=
�rr��x�neA��sHar�ec��ai'��uo>=co�ER �- ,
r
System
Deck (Note i)
Base Sheet
Roof Cover (Note 15)
MDP
No.
Base
Fasteners
Attach
Base Ply
Cap Ply
(psf)
Min. 19/32-inch
Polyglass Elastobase, Polyglass Elastobase
Poly, Polyglass G2 Base, CertainTeed
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch
(Optional) One or
W-1
plywood at max.
Glasbase, Firestone MB Base, JM Perma-
Roofgrip #14, Dekfast Hex with Dekfast #14
o.c. in two, equally spaced, staggered
more BP -AA or
SBS-AA, SBS-
-52.5
24-inch spans
Ply 28, Tamko Glass Base or GAFGLAS #75
or TruFast MP-3 with TruFast HD
center rows
APP-TA
TA, APP TA
Min. 19/32-inch
Polyglass Elastobase or Polyglass
Dekfast Hex with Dekfast #14 or TruFast MP-
12-inch o.c. in 4-inch lap and 12-inch
One or more SBS-
SBS-SA, APP-
W-2
plywood at max.
Elastobase Poly with poly top surface
3 with TruFast HD
o.c. in two, equally spaced, staggered
ered
SA
SA, SBS-TA or
-52.5 *
24-inch spans
center rows
APP-TA
Min. 19/32-inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch
(Optional) One or
SBS-AA, SBS-
W-3
plywood at max.
Elastobase Poly
Roofgrip Roof ri #12
o.c. in two, equally spaced, staggered
more BP -AA or
-60.0
24-inch spans
center rows
APP-TA
TA, APP-TA
Min. 19/32-inch
Polyglass Elastobase or Polyglass
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-inch=SA
SBS-SA, APP-
W-4
plywood at max.
P Yw
Elastobase Poly with poly top surface
Roofgrip #12
o.c. in two, equally spaced, staggeredSA,
SBS-TA or
-60.0 *
24-inch spans
p
center rows
APP-TA
iol
e
:.
.:
TA64E �F' WOOU= 'ELKS— NE1Al,CO1ti15TRUCTION R° ER ' F'` T F
P $ OO
y
a "
£ Q {ERR
c-_
+
, c
SYSTEMi*@ F: tVO CNSUI 1tTIrLt St2' bED:RfJOF CU1l,
System
Roof Cover (Note 15)
MDP
No.
Deck Primer
Joint Treatment Base Ply
Ply
Cap Ply
(psf)
W_5
Min. 15/32-inch plywood
(Optional) ASTM D41
None
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
at max. 24-inch spans
SBS-SA
APP-TA
or APP-TA
-90.0
Min. 15/32-inch plywood
Plywood joints are covered with 4-inch wide strips of TriBuilt SA
(Optional) SBS-SA or
SBS-SA, APP-SA, SBS-TA
W 6
at max. 24-inch spans
(Optional) ASTM D41
SBS Base, rolled into place to create continuous bond.
TriBuilt SA SBS Base
APP-TA
or APP-TA
97.5
Exterior Research and Design, U.C. d/b/a Trinity ) ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
e" EDITION (2017) FBC NON-HVHZ EVALUATION
TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485
Evaluation Report A42970.10.12-R2 for FL16027-112