HomeMy WebLinkAboutINSULATION INSTALLATION CERTIFICATESSty Lucie Couniy
INSULATION INSTALLATION CERTIFICATE
L&C Construction LOT BLOCK: SECTION:
JOB#: 113712 JOB NAME: Gruber Res
JOB ADDRESS: 10725 S Ocean Drive
The undersigned hereby certifies that insulation has been installed at the above described property as -0
follows: (0) (DD
1. Exterior CBS walls have been insulated with ............................Check one ( ) Spray on cellulose 3
to a thickness of N/A inches, which thickness, according to the () Fiberglass blankets r: cn
manufacturer, FiFoil & CFI ()o Aluminum Foil _n, m
Density N/A will yield an "R" value of 4.1 & 9 Or) Block Fill CD L0 -n ?
Exterior Frame walls have been insulated with ............... ...Check one () Spray on cellulose 0 (D D
to a thickness of 6.25 inches. which thickness, according to the (� Fiberglass blankets � -0 o �` �r��a
manufacturer, Certainteed ( ) Aluminum Foil co `-
Density N/A will yield an "R" value of 19 ( ) Other Spray Foam `<
3
2. Main Ceilings have been insulated with .........................Check one ( ) Fiberglass blanketsfD
to a thickness of 5.25 inches, which thickness, according to the ( ) Fiberglass loose fill
manufacturer, SES Sucraseal ( ) Aluminum Foil
Density N/A will yield an "R" value of 20 OpSpray. Foam
Ceilings Cathedral have been insulated with .........................Check one () Fiberglass blankets
to a thickness of inches, which thickness, according to the () Fiberglass loose fill
manufacturer, () Aluminum Foil
Density N/A will yield an "R" value of () Other cellulose
3. Interior knee walls have been insulated with.................................Check one () Fiberglass blankets
to a thickness of 5.25 inches, which thickness, according to the () Polyurethane
manufacturer, SES Sucraeal () Spray on cellulose
Density N/A will yield an "R" value of 20 00 Other Spray Foam
4. Garage partition walls of conditioned living areas have been
insulated with ...... .......................... ..:.... - Fiberglass blankets
to a thickness of3.5 & 6.25mches, which thickness, according to the ( ) Spray on cellulose
manufacturer, Certainteed ( ) Polyurethane
Density N/A will yield an "R" value of 11 & 19 ( ) Other Aluminum Foil
MULTI FAMILY RESIDENTIAL CONSTRUCTION ONLY: The common (party) walls separating
different tenants shall be insulated as follows - Frame/Metal stud walls R-11 (Min.); CBS or Concrete walls
R-3 (Min.); by Energy Code requirements. See Energy Code Rev. I/87, paragraph 903.2(b), on page 9-17,
latest edition. These "minimums levels of insulation" are not included in the Energy Calculations, but shall
be installed in the field.
NOTE: Densities of sprayed on, loose fill, or any other composed -on site insulation shall be the P.C.F.
(lb/ft3) average of three (3) "DRY SAMPLES" of actual installation. ,
MER Entepprises, LLC
_ i' _��1C, , J y
Insulation Contractor-
Insulation Contractor Signature
_MCIN6231
8/18/18.'-
Insulation Contractors CC#
_
Date of Certification m
Builder's Name - Builder's CC#
Nmary Publ is I