Loading...
HomeMy WebLinkAboutEVALUATION REPORTI lk SCANNED BY 1p9a colintv EVALUATION KLrUXt OF METAL. SALES MANUFACTURING. CORPORATION '26GA. 5V=CRIMP PANEL FLORIDA BUILDING CODE 6TH EDITION (.2017) FLORIDA PRODUCT APPROVAL FL 14645.3-,R3 ROOFING METAL ROOFING JAN 3 12919 sT. Lucie County, Pemlldng Prepared For: Metal Sales Manufacturing. Corporation 545 south 3rd Street; suite 200 '.Louisville,. !CV 40202 - Telpphonp-: (W),:855-4300 Fax: (502) 855-4200 Prepared By: :Bala. Sockilingainft.O.,.P.E. Florida Professional, Engineer #62240 12-16 N Lansing Ave., Suite C Tulsa; OK 74106 Telephone: (018) 492-5.992 FAX: (866) 366-1543 ST. LUCIE COUNTY I BUILDING DIVISION R E V I FOR 00 APL REVIEWED BY DATE 2-z.>-/& PLANS AND PEYMIT mus'r BE KEPT W( JOB OR 1 140 INSPECTION V-11L BE MADE THESE PLANS ANC ,ALL PROPOSED WORK ARE SUOJECTio ANY CORRECiTIONS REQUIRED BY FIELD INSPECTIONS THAT MAY BE NECESSMy IN ORDER TO COP11PLY WITH ALL APPLVb---1"' coDES. ""'411 FASTENERS ORA ITA CHMEM ARE THE RESPONSIBILRy OF THE CONTRACTOR OFRECORD F11 This report consists of Evaluation Report (3 Pages including cover) *0111110:1't Installation Details (I Page) % SOCK 5 N :N 6 6-2240 % -33- STATE OF Report No. C2182-3 ..A, Z, Date: 9.9.17 .0 Manufacturer: Product Name: Panel Description Materials: Metal Sales Manufacturing 5V-Crimp 24" wide coverage with (5) 1/2" ribs FL 14645.3-R3 9.9.17 Page 2 of 3 Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. 3/a" thick wood plank (min SG of 0.42) . for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1. Required for new construction L� optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" O.C. (Factor of Safety = 2) 74.8 psf @ fastener spacing of 16'I O.C. 196.75 psf @ fastener spacing of " o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accoi Requirements for Metal Roofing Code Compliance: The product described herein has 2017 Section 1507.4. Product Limitations: Design wind loads shall be determ with FBC 2017 Section 1609 or design. The maximum support s exceeded. This evaluation report with TAS 125-03 `Standard _1 compliance with FBC ined for each project in accordance ASCE 7-10 using allowable stress pacing listed herein shall not be is not applicable in High Velocity {. Itr FL 14645.3-R3 C2182-3 9.9.17 Page 3 of 3 Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report . from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests 41 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/l/09 EXISTING SHINGLES SEE DETAIL 2 SEE DETAIL 1 NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP (OPTIONAL) / �(pANEL OVERLAP) (REQUIRED CONSTRUCTION) ENDS `ENDSI ONLY. RED OR PANEL NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) NEW UNDERLAYMENT- (REQUIRED ONLY FOR NEW CONSTRUCTION) EXISTING SHINGLES (OPTIONAL) EXISTING UNDERLAYMENT (OPTIONAL) MINIMUM ATTACHMENT: Sd x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS SPACED ® 6" O.C. IN THE FIELD & MIN. 2X_ WOOD RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES TRUSS AT MAX. 24" O.C. TYPICAL PANEL ---INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. DETAIL 1 19/32 THICK (MIN #9-16 OR #10-14 WOODSCREWS WITH SELF SEALING WASHER AT MAXIMUM SPACING OF 36" O.C. 5V-CRIMP MIN 26 GA. EXISTING UNDERLAYMENT V PLYWOOD (OPTIONAL) 19/32" THICK (MIN.) DETAIL 2 PANEL FASTENER PER ALLOWABLE PRESSURE TABLE ON THIS SHEET, ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE SPACING (PSF) (IN) 36 j 41.6 16 74.8 8 196.75 d Ir-.p-- V N 0 w N Z ~p a. pNp NO�p M tnYI V) o u.i � � MCI jN to o0 sa a I� u0 s� Wa l a w GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE v FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS iN SPECIFIED ON. THIS DRAWING. - 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS - PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS c N ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE. DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.