HomeMy WebLinkAboutEVALUATION REPORTa� SCANNED BY St Lucia; Coin* EVALUATION REPORT OF METAL SALES MANUFACTURING COI '26 GA. 5V-CRIMP PANEL' ST, LUCIE COUNTY BUILDING DIVISION PfIeQ90E4"rf�� FOR C®65 PLBns-' , REVIEWED BY DATE 6—( LANS AND P RMIT �TpJ i BE KEPT ON JOB OR —NCO INSPECTION WILL 13E. MADE FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVALTHHE I iLIANS AND ALi_'PR0p 0SED 11v0R;{ FL 14645.4-R3 AR[: S11, JFC7- TO) AN)V ROOFING RF0UIF1EI) E"I 1:1E,LEI !HE)P;Crojdq Tl!AT METAL ROOFING WAy b COfr;�'Ia VVIPH AU, �,Pi Jjjofq,&l . MAR 0 5 2018 ST. Lucie County, Permitting C Prepared For: .Metal Sales Manufacturing Corporation 545 South 3rd Street, Suite 200 Louisville, KY 40202 CONCFALED FASTENERS OR ATTACHMENTS Telephone: (502)'8554300 ARE THE RESPONSIBILITY OF THE F Fax-' (502) 8554290 - " CONTRACTOR OF RECORD Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 i216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: ' (918)-493-3568 ' This report consists of Evaluation'Report (3 Pages including cover) Installation Details (1 Page) +o%%%'.S0GKAt jN-f�i,� Load Span Table (1 Page) .+Q�,Q;.*G E N S.•.�•'-9, •�� Report No. C21824 Date:' 9.9.17 No 62240 STATE OF :I ' O ` 0 R 10 ��� S •... ALA, `�++ ,q. 2p1-7 %f t Manufacturer: Product Name: Panel Description: Materials: -' FL 14645.4-R3 C2182-4 9.9.1.7 Page 2 of 3 Metal Sales Manufacturing Corporation 5V-Crimp 24" wide coverage with (5) 1/2" high ribs 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or plume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 7/16" thick OSB or min. 15/32" thick plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) inl the plywood field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC-2017 Section 1507.4.5.1. Slope: 1/112 or greater in accordance, with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c. (Factor of Safety = 2) 172 �5 psf @ fastener spacing of 6" o.c. Fastener Pattern: �: Type: 0-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient, length to penetrate, through the deck a minimum of 3/81 and installed as.per Metal Sales current installation procedure. " `At panel ends @ 6" a�.c. across panel width :At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering Systems,''. Test Equivalency: The test procedures in UL 1897-04 comply with test procedures nrescribeld in UL 1897-12. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4. Product Limitations: Design w.' d loads shall be determined for each project in accordance with FBCF2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be r FL 14645.443 C2182-4 9.9.17 Page 3 of 3 computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM EI08/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: UL580 & 1897 Test Reports PRI Construction Materials Technologies MSMC-017-02-01, Reporting Date 9/20/13 . q I PANEL OVERLAP Im Im `"EM= u" 5V-CRIMP PLOTI DAM�I10 --SEE DETAIL 2 � -SEE DETAIL 1 / FASTENER AT PANEL FLAT REQUIRED FOR PANEL ENDS ONLY. lz MINIMUM ATTACHMENT: PANEL FASTENER PER UPLIFT LOAD TABLE UNDERLAYMENT SHALL BE INSTALLED 8d x 2.5" LONG RING SHANK NAIL OR #8 x 2" LONG WOOD SCREWS AS PER MANUFACTURER'S NSTALLATION GUIDELINES SPACED ®6" O.C. IN THE FIELD $ & AT EDGES MIN. 2X- WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. n TYPICAL PANEL INSTALLATION X-SECTION a W DC-4O 0 N9-16 OR #10-14 WOODSCREWS fXI SELF SEALING WASHER`AT - Ln MAXIMUM SPACING OF 36" O.C. M Ln ` 5V-CRIMP h�0' MIN 26 GA. GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE �' a Jx UNDERLAYMENT WITH THE FLORIDA BUILDING CODE (FBC). -a -=—"-,i a j$ DETAIL 1 OSB 7/16" THICK (MIN.) OR PLYWOOD 15/32" THICK (MIN.) 2. ROOF PANELS SHALL BE MIN-26-GA.-(t-= O;019 .EFFECTIVE COVERING = WIDTH-OF-PANEL-24"- 1P 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS 89 SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS i #9-16 OR #10-14 WOODSCREWS _WITH-SELF'SEALING—WASHER AT PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON THIS DRAWING. x vi MAXIMUM SPACING OF 36" D.C. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM - REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 5V-CRIMP 6 RAFTERS/JOISTS/TRUSSESIGNTO WITHSTAND WIND LOADS AS THE MIN 26 GA. REQUIRED FOR EACHAPPLICATION AND RESPONSIBILITY OF OTHERS. UNDERLAYMENT — OSB 7/16" THICK (MIN.) OR DETAIL 2 PLYWOOD 15/32" THICK (MIN.) OF 1 METAL SALES MANUFACTURING CORPORATION 5V-Crimp Uplift Loads (Min. 26 ga.) Description Fastener Spacing along panel length (in) Allowable Uplift Load (psfl Coverage width: 24" Panel Fasteners #9-16 or #10-14 hex head wood screws with sealed washer 6 172.5 120.0 _ -_-_- _ 90.0 72.0 9 12 - 15 _ 18 60.0 51.4 21 24 _ 45.0 40.0 -- - -- 27 30 36.0 � 32.7 33 36 30.0 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 14645A and Metal Sales current installation procedure. 3. Three or more spans condition. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 918 492 5992 a�,111111I//III gOCKg4�°�i�i %% p.•• i No 62240 v -D : •: Q STATE OF <U: Ole 0 GI 9,-Q 2 k-7 Bala Sockalingam, Ph.D., P.E. FL 62240