Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PRODUCT APPROVAL MODIFIED BITUMEN ROOF SYSTEM
1/11/2018 Florida Building Code Online BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search Florida Product Approval USER: Public User Product Aooroval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email FL1654-R22 Revision 2017 Approved 0 POLYGLASS USA 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 Ext 242 jakins@polyglass.com James Akins jakins@polyglass.com Maury Alpert 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAIpert@polyglass.com Ariel Lender 1111 W. Newport Center Drive Deerfield Beach, FL 33442 ST. LUCIE C61JNT � SUILDING CIVISIo lam,VI-�;�E- FOR C )FJIPLII e REVIEVJEED E3`r' DATE Z-05-/ .ANS AND PE I' -MIT Musy E3E KEPT ON, J©E on I NO 11 5bECTl0N V/!LL EE KaC) f THESE PWIS AND AL,L PTOPOSED jymn { AR SUBJECT TO ANY CORFIE" IONS MAYBE NECESSAA,Y 1-4 0,90 COi'uFLY WITH AUA, CONCFALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD z ® M 4F hftps://www.floddabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhdKjvCZfSdk%2fxn%2fYWFx5rxA%3d%3d 1/4 1/11/2018 Florida Building Code Online (954)233-1230 ALender@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer © Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE I] Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL1654 R22 COI 2017 01 COI Nieminen.odf Standard Year ASTM D6162 2008 ASTM D6163 2008 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 2009 FM 4470 2012 FM 4474 2011 UL1897 2012 https://www.floddabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhdKjvCZfSdk%2fxn%2fYWFx5rxA%3d%3d 2/4 1/11/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/14/2017 09/15/2017 09/22/2017 12/12/2017 FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R22 -II 2017 09 FINAL Al ER POLYGLASS MODBIT FL1654- R22.1?df Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete FL1654 R22 AE 2017 09 FINAL ER POLYGLASS MODBIT FL1654- R22.12df deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits Created by Independent Third Party: Yes of Use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S, must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® ECfFcE https://www.floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhdKjvCZfSdk%2fxn%2fYWFx5rxA%3d%3d 3/4 1/11/2018 Florida Building Code Online -r r fa securitymETRICS https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAhdKjvCZfSdk%2fxn%2fYWFx5rxA%3d%3d 4/4 EVALUATION REPORT Polyglass USA, Inc. 150 Lyon Drive Fernley, NV 89408 (570) 384-1230 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203)262-9245 Evaluation Report P9290.02.08-1120 FL1654-R22 Date of Issuance:02/11/2008 Revision 20: 09/12/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6:h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Polyglass SBS and APP Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6, plus a 58-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/12/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. el TRINITY I ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: Polyglass SBS and APP Modified Bitumen Roof Systems, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the I th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.3.1 Wind UL 1897 2012 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6162 2008 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 1507.11.2 Physical Properties ASTM D6509 2009 3. REFERENCES: kattl Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-Ri 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) FM 4470/4474 P41630.08.13 08/06/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 ERD (TST6049) Physical Properties P39520.09.14-2 09/11/2014 ERD (TST6049) FM 4470/4474 SC6160.11.14 11/10/2014 ERD (TST6049) Physical Properties PLYG-P45440SC.03.15-1 03/31/2015 ERD (TST6049) Physical Properties SC5170.05.15 05/08/2015 ERD (TST6049) FM 4474 SC8085.05.15 05/19/2015 ERD (TST6049) Physical Properties SC5170.12.15 12/29/2015 ERD (TST6049) FM 4470/4474 SC9455.15 04/01/2016 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-1 05/17/2016 ERD (TST6049) FM 4470/4474 PLYG-SC8905.05.16-2 05/17/2016 ERD (TST6049) FM 4470/4474 PLYG-SC10815.07.16-RI 09/23/2016 ERD (TST6049) UL1897 PLYG-SC12025.10.16 10/12/2016 ERD (TST6049) FM 4470/4474 PLYG-SC11475.16 11/17/2016 ERD (TST6049) FM 4470/4474/UL1897 PLYG-SC13235.01.17 01/17/2017 ERD (TST6049) FM 4474/UL1897/TAS 114 PLYG-SC13920.05.17 05/30/2017 ERD (TST11294) FM 4474/UL1897/TAS 114 PLYG-CTL13945.05.17-1 05/30/2017 Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 2 of 6 Entint ERD (TST11294) ERD (TST6049) ERD (TST6049) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) FM Approvals (TST1867) PRI(TST5878) PRI(TST5878) PRI (TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) PRI(TST5878) Miami -Dade (CER1592) Miami -Dade (CER1592) UL LLC (QUA9625) 4. PRODUCT DESCRIPTION: Examination FM 4474/UL1897/TAS 114 FM 4474/UL1897 FM 4474/TAS 114 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 FM 4470/4474 Physical Properties Physical Properties Physical Properties Physical Properties TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 HVHZ Compliance Proposal for Review Quality Control Reference PLYG-CrL13945.05.17-3 PLYG-SC13945.05.17 PLYG-SC15760.09.17 2W7A7.AM OD3A3.AM 2DOAO.AM 2D5A9.AM 3006646 3001334 3001334 3000857 3004091 3006115 3012321 3014692 3014751 3007170 3019317 3020703 3018332 3023368 3024594 3023458 3030668 3032172 3049631 3057029 PUSA-062-02-01 PUSA-061-02-02 PUSA-064-02-02 PUSA-062-02-02 PUSA-188-02-01 PUSA-188-02-02 PUSA-188-02-03 PUSA-202-02-01 PUSA-202-02-02 Various NOAs 10-0823 Service Confirmation, R14571 �I 1 RINITYIERD Date 05/30/2017 05/30/2017 09/11/2017 08/04/1994 04/04/1997 12/23/1998 06/22/1999 01/04/2000 01/25/2000 02/15/2000 01/12/2000 01/12/2000 05/02/2001 07/29/2002 08/05/2003 08/27/2003 01/13/2004 06/30/2004 07/30/2004 O1/31/2006 03/20/2006 05/23/2006 07/18/2006 09/12/2007 06/12/2009 04/21/2014 02/02/2017 12/04/2007 O1/28/2008 02/27/2008 12/04/2008 02/08/2017 02/08/2017 02/08/2017 05/17/2017 05/17/2017 Various 10/12/2010 Exp. 10/06/2018 This Evaluation Report covers Polyglass Modified Bitumen Roof Systems installed in accordance with Polyglass USA, Inc. published installation instructions and the Limitations / Conditions of Use herein. The following Polyglass membranes make up the subject systems. TABLE 1:'ROLL=GOODS FOR POLYGLASS' MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Grade Type Base Sheets Polyglass G2 Base ASTM D4601 N/A II Polyflex SA Base ASTM D4601 N/A II Polyglass APP Base ASTM D6509 N/A N/A Exterior Research and Design, U.C. Evaluation Report 139290.02.08-1120 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-R22 Polyglass Modified Bitumen Roof Systems, (570) 384-1230 Revision 20: 09/12/2017 Page 3 of 6 TABLE 1, (CONTINUEDI: ROLL -GOODS FOR POLYGLASS MODIFIEWBITUMEN ROOF,; SYSTEMS Type Product Specification Reference Grade Type SBS Membranes Polyglass HT Base 650 ASTM D6162 S III Elastobase ASTM D6163 S I Elastoflex V ASTM D6163 S I Elastoflex SA V Base ASTM D6163, Table 2 S I Elastoflex SA V FR Base ASTM D6163, Table 2 S I Elastoflex SA V Plus ASTM D6163 S I Elastoflex SA V Plus FR ASTM D6163 S I Elastobase Poly ASTM D6164 S I Elastoflex S6 ASTM D6164 S I Elastoflex S6 Type II ASTM D6164 S II Elastoflex VG ASTM D6163 G I Elastoflex VG FR ASTM D6163 G I SBS Membranes Elastoflex S6 G ASTM D6164 G I Elastoflex S6 G FR ASTM D6164 G I Polyfresko G SBS (sand or poly -film backed) ASTM D6164 G I Polyfresko G SBS FR (sand or poly -film backed) ASTM D6164 G I Elastoshield TS G ASTM D6164 G I Elastoshield TS G FR ASTM D6164 G I Elastoflex SA P ASTM D6164 G I Elastoflex SA P FR ASTM D6164 G I Polyreflect ASTM D6164 S I APP Membranes Polyflex ASTM D6222 S I Polyflex G ASTM D6222 G I Polyflex G FR ASTM D6222 G I Polyfresko G ASTM D6222 G I Polyfresko G FR ASTM D6222 G I Polybond ASTM D6222 S I Polybond G ASTM D6222 G I Polyflex SA P ASTM D6222 G I Polyflex SA P FR ASTM D6222 G I Polyfresko G SA ASTM D6222 G I Polykool ASTM D6222 S I S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. Exterior Research and Design, U.C. Evaluation Report P9290.02.08-R20 Certificate of Authorization #9503 6m EDITION (2017) FBC NON-HVHZ EVALUATION FL3654-R22 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 4 of 6 l ' TRINITY 1 ER® 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDi, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6. INSTALLATION: 6.1 Polyglass Modified Bitumen Roof Systems shall be installed in accordance with Polyglass USA, Inc. published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. Evaluation Report P9290.02.08-R20 Certificate of Autharization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 394-1230 Revision 20: 09/12/2017 Page 5 of 6 C)o TRINITY I ERD 6.3 Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. Refer to current Roofing Materials Directory for fire ratings associated with coating usage. ➢ PG200 Non-Fibered Roof Coating; ➢ PG300 Fibered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; ➢ PG650 Fibered Aluminum Roof Coating; ➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; ➢ PG700QS (Quick -Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (over granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Fibered Aluminum Roof Coating; ➢ Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; ➢ Polybrite 70QS (Quick -Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (over granule - surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating; ➢ Polybrite 95 Silicone Roof Coating. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com - THE 58-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report P9290.02.08-1120 Certificate of Authorization N9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL1654-1122 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Revision 20: 09/12/2017 Page 6 of 6 �INITYI ERD TABLE F-2: WOODDECKS—NEW,CONSTRUCTION,:REROOF(TEAR-OFF)oRRECOVER SYSTEM TYPE E:: NON-INSULATED;,MECHANICALLYATTACHED BASE SHEET (SCREW & PLATES) BONDED ROOF _ _ COVER System 1) Base Sheet Roof Cover (Note 15) MOP No. Deck (Note Type Fasten Attach Base Ply Cap (psf) SELFADHERING WE PLY:, Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. In 4-inch lap and 12-inch o.c. in two SBS-SA, APP-SA, SBS- W-136 Inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows SBS-SA TA, APP-TA -52.5* W-137 Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-Inch lap and 12-Inch o.c. in two Polyflex SA Base APP-TA -52.5* inch plywood (poly -film top) or Trufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows W-138 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-Inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- -60.0* inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA W-139 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-Inch lap and 12-Inch o.c. in two polyflex SA Base APP-TA 60.0* inch plywood (poly -film top) (2), equally spaced, staggered center rows TABLE IG: WOOD DECKS — NEW CONSTRUCTION it REROOF (TE!AR-OFF) i :. . • = SYSTEM TYPE F NON INSULATED; BONDEDROOF'COVER + System Roof Cover (Note 1S) No. Deck (Note 1) Primer MDP (psf) Joint Treatment Base Ply Ply Cap Ply l Noe Mara p -90.0ne TAA APP-TA W-141 Min. 15/32- (Optional) PG100 None Polyflex SA Base (Optional) APP-TA APP-TA -90.0 Inch plywood W-142 Min. 15/32- PG100 None SBS-SA (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97 5 inch plywood TA, APP-TA TA, APP-TA W-143 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Base or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- 97 5 Inch plywood place to create continuous bond. Elastoflex SA V FR Base TA, APP-TA TA, APP-TA W 144 Min. 15/32- WB-3000 None SBS-SA (Optional) SBS-SA, APP-SA, SBS- _105.0 Inch plywood TA, APP-TA W-145 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Elastoflex SA V Plus or (Optional) SBS-SA, SBS- SBS-SA, APP-SA, SBS- inch plywood place to create continuous bond. Elastoflex SA V Plus FR TA, APP-TA TA, APP-TA -135.0 W-146 Min. 15/32- (Optional) PG100 Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into Polyflex SA Base (Optional) APP-TA APP-TA -135.0 inch plywood place to create continuous bond. Exterior Research and Design, U.C. d/b/a Trinity ) ERD Evaluation Report P9290.02.08-R20 for FL3654-R22 Certificate of Authorization #9503 6P EDITION (2017) FBC NON-HVHZ EVALUATION Revision 20: 09/12/2017 Prepared by: Robert Nieminen, PE-59166 Polygiass Modified Bitumen Roof Systems; (570) 394-1230 Appendix 1, Page 21 of 58