Loading...
HomeMy WebLinkAboutENGINEERING SUBMMITALrt SCANNED ._, B St Lucie CouE�NGINEERING SUBMITTALS January 11, 2018 WIND LOAD CERTIFICATION: CODE FBC 2017 6TH ADDITION/ FRC 2017/ ASCE 7-10 WIND SPEED: 170 mph, 3 SEC. GUST EXPOSURE: "D" IMPORTANCE FACTOR: 1.0 INTERNAL PRESSURE COEFF.: 0.00 JOB: OLSEN RESIDENCE 1217 NETTLES BLVD - --.ivcV I FEB 0 8 2018 E• Lucie Count y, Permitting I ST LUCIE COUNTY BUILDING DIVISIO FOR GOMPL REVIEWED BY DATE PLANS AND PERMIT MUST ®E KEPT ON JOB OR NO IN$PECTjo1j Va/iL.L CE MADE THESE PLANS V0 All PP0rjO? yrr WORI- ARE SUBJECT 0 ANY 0,01='f'.�f : i 101t8 REQUIRED RY rlrl,0 INSPrC tca S THAT MAY BE iVECESSkjy Ii�J ORDrR p COMPLY 1!VI`ili XLLAP► ix4us ;=ISO Sr JENSEN BEACH, FL cogFj��I�l{ili,�rla���riliwu�� ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#1.14 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email — nwelchinc@aol.com Paul Welch, P.E. Fla Reg. No. 29945 0�1 Jensen Bel i �r 0 N r1 T UW _jw11' ZJ� ti�� JF- W`�J wOJ��Oz w � (LLD,�w�z�oc W CO -0 O a OLSEN ; ' - Jerner & Associates, Inc. SHEET 9 !- - Marine & Environmental Consulting Date: 116118 1217 NETTLES BLVD ` - 2537SEAlfonso Ave 2950 Poor � ciFL34952 JENSEN BEACH �(a` }-,T=, JERNERNELLSOUTH.NET 0�1 LADDER AFFIXED W (4)%' x 5" SS LAG BOLT EXACT LOCATION TO BE DETERMINED ONSITE MANMADE CAI 48' WIDE OLSEN 1217 NETTLES BLVD JENSEN BEACH r { LINE oF-0 E 'S ISLAND INC, A CONDO- 'TION II PARCEL 1217 1E ?ILINE _ _ _ 1 " = 10' - ,—� Jerner & Associates, Inc. Marine & Environmental Consulting Date: 116118 —i f'-- 2537SEAifonsoAve- Port St. Lucie, FL34952 Ph(772)283-2950 JERNERNELLSOLITftNET qtr CD .z�M T U w -, Uj n- zJwa:,ac", UVWwC)0 U U-DwUj wU �w--D� m¢ °'w00~�U- 2mIr r0 a SHEET 2 Dock Section Thru SGL Bolts, Nut s Washers 518 S.S. (3C w Nut Fully Threade 10, f 2" x 6" SYP Decking w � Minimimalplank spacing Fasten w #10 3" SS (304 + 11 : • Screws, 2 per Stringer t 2" x 8" P. T. SYP, .4 ACQ treated stringer, _. _.._.._.._.._.._.._. _..' .._.MH1K_.. be buttjointed, but joints to be staggere �I 2"x 8"P.T. SYP, .4 ACQ treated DBL be, Pilings jetted to a minimum depth of 6' and as necessary to provide adequate bearing and stability OLSEN 1217 NETTLES BLVD JENSEN BEACH Min. 8" Dia. 2.5 CCA treated piles Dock Plan View 10, Center Stringers) toe Nailed w (2) #16 SS (304) Ring Shank Nails @ Each Bent Outside Stringers Face Nailed w #16 SS (304) Ring Shank Nails, Inside or Outside Stringers — -- -:—: —i Jerner & Associates, Inc. Marine & Environmental Consulting 25375EAlfonso Ave Port St.Lucie, FL34952 G — I Ph.(772)283-2950 JERNER@BELLSOLITH.NET Date: 116118 110* co z '— M .tA UW Jwv ZJ1-�U-a:,a U�? �rUO J12 Jz WUO?w W .mow a�JC �r(n UOF-- SHtET 3