HomeMy WebLinkAboutENERGY EFFICENCY CODESCANNED
FORM R405-201'4 BYE.- �� ;' `1 4:',,,'�� ��
FLORIDA ENERGY EFFIMBNO ��; l FOR BUILD V� N R X SON
\
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Grendine Club eClassic MDW 50
Builder Name: GHO Homes
Street: 2680 Conifer Dr.
Permit Office:
City, State, Zip: Ft. Pierce , FL , 34951
Permit Number:
Owner: GHO Homes
Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1607.3 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block- Int Insul, Ekteidor
R=4.t 1608.40"ft'
b. Frame - Steel, Adjacent
R=11.0 199A 1 ft'
3. Number of units, if multiple family 1
c. N/A
R= ff
4. Number of Bedrooms 2
d. N/A
R= ft'
5. Is this a worst case? No
10. Ceiling Types (1832.0 sqft.)
Insulation Area
a. Under Attic: (Vented)
R=30.0 1832.00 ft
6. Conditioned floor area.above grade (W) 1832
b. N/A
R= ft'
Conditioned floor area: below grade (ft!) 0
c. NIA
R= ft2
11. Ducts
R ft'
7. Windows(259:0 sqft.) Description Area
a. Sup: Attic, Ret: Attic,,AH: Main
6 366.4
a. U-Factor: Dbl, U=0.62 151.00 ft'
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.51 96.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
36.0 SEER:16.00
c. U-Factor: Dbl, U=0.40 12.00 ft'
SHGC: SHGC=0.26
13: Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft=
a. Electric Strip Heat
36.0 COP:1.00
SHGC:
Area Weighted Average Overhang' Depth: 6.745 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems.
a. Electric-
Cap: 50 gallons
8. Floor Types (1832.0 sgft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1832.00 ft�
b. Conservation features
b.,N/A R= ft'
None
c. N/A R= ft'
15. Credits
Pstat
Glass/Floor Area: 0.141 Total Proposed Modified Loads- 59.80
PASS
Total Baseline Loads: 60.30
I hereby certify that the plans and specifications covered by
Review of the plans and
TRi; sTAT�
this calculation are in compliance with the Florida Energy
specifications covered by this
o�
�`. V.
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Ryan McCracken /
Before construction is.completed
DATE: 4130/201A
this buiid(ng.will be inspected for
compliance with Section 553.608
* c r
1 hereby certify th is bui 1 , as esign s in. ompliance
Florida Statutes:
with the Florida nerg C,
Opu
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certif%ation by the air handlerunit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2A.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
ALL PROJECTS require an envelope leakage test report with envelope leakage no greater than 7 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn. requires a Duct Leakage Test Report confirming duct leakage to outdo,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. ;, h t
4/30/2018 9:54 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software ✓Page 1 of 4
FORM R405-2014
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment
Grendlne Club_eClassic MD Bedrooms: 2
User Conditioned Area: 1832
OHO Homes Total Stories: 1
1 Worst Case: No
GHO Homes Rotate Angle: 180
Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/SubDlvision:
PlatBook:
Street: 2680 Conifer Dr.
County: St. Lucie
City, State, Mp: Ft. Pierce ,
FL. 34951
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE CO_INTL FL VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
1832 17092.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main
1832 17092.6 Yes 3
2
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 189.33 ft 0
1832 ft'
---- 0.8 0 0.2
ROOF
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emift Emitt Deck Pitch
Tested Tested Insui. (deg)
1
Hip
Concrete 2049112 0 Its Medium
0.75
No 0.9 No 0 26.6
ATTIC
/
v #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 1832 ft'
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Mein 30 Blown
1832 ft° 0.11 Wood
4/3012018 9:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
0:
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
1
S=>N Exterior
Concrete Block - Int Insul
Main
4.1 12
4
9 4
115.1 ft'
0 0.600000
0
2
W=>E Exterior
Concrete Block - Int Insul
Main
4.1 2
8
9 4
24.9 ft°
0 0.600000
0
3
S=>N Exterior
Concrete Block - Int Insul
Main
4.1 6
4
10 8
67.6 ft°
0 0.600000
0
_ 4
E=>W Exterior
Concrete Block - Int Insul
Main
4.1 2
8
9 4
24.9 ft°
0 0.600000
0
_ 5
S=>N Garage
Frame - Steel
Main
11 21
4
9 4
199.1 fP
0.23 0.01
0
6
W=>E Exterior
Concrete Block - Int Insul
Main
4.1 51
10
9 4
483.8 ft'
0 0.600000
0
7
N-S Exterior
Concrete Block - Int Insul
Main
4.1 16
2
9 4
150.9 ft'
0 0.600000
0
8
E=>W Exterior
Concrete Block - Int Insul
Main
4.1 10
0
9 4
93.3 ft=
0 0.600000
0
9
N=>S Exterior
Concrete Block - Int Insul
Main
4.1 23
10
10 8
254.2 ft°
0 0.600000
0
10
E=>W Exterior
Concrete Block - Int Insul
Main
4.1 42
2
9 4
393.6 ft'
0 0.600000
0
DOORS
# Omt
Door Type Space
Storms U-Value
Width
Height Area
Ft
In
Ft In
1 S=>N
Insulated Main
None
.14
1
3
8 10 ft'
2 S=>N
Wood Main
None
.14
2
8
8 21.3 ft'
WINDOWS
Orientation shown Is the entered orientation => changed to As Built rotated 180 de roes .
Wall
Overhang
# Omt ID
Frame Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade Screening
1 S=>N 1
Metal Low-E Double
Yes
0.62 0.25
24.0 ft°
8 It 0 in
1 ft 0 In '
Drapes/blinds
None
2 W=>E 6
Metal Low-E Double
Yes
0.62 0.25
20.0 ft°
1 It 0 in
0 It 9 In
Drapes/blinds
None
3 W=>E 6
Metal Low-E Double
Yes
0.62 0.25
6.0 ft=
1 ft 0 In
0 ft9 In
Drapes/blinds
None
4 W=>E 6
Metal low-E Double
Yes
0.4 0.26
12.0 ft'
1 ft 0 in
0 ft9 in
Drapesiblinds
None
5 N=>S 7
Metal Low-E Double
Yes
0.62 0.25
30.0 ft'
1 ft 0 in
1 ft 0 In
Drapes/blinds
None
8 N=>S 9
Metal Low-E Double
Yes
0.51 0.22
96.0 IF
11 ft 0 in
2 It 5 in
Drapes/blinds
None
7 N=>S 9
Metal Low-E Double
Yes
0.62 0.25
36.0 ft'
11 ft 0 In
2 ft 2 In
Drapes/blinds
None
8 E=>W 10
Metal Low-E Double
Yes
0.62 0.25
20.0 ft'
1 ft 0 In
2 ft 6 in
Drapes/blinds
None
9 E=>W 10
Metal Low-E Double
Yes
0.62 0.25
15.0 ft'
1 ft 0 In
0 It 8 In
Drapes/bllnds
None
GARAGE
# Floor Area Calling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 562.9489 ft2 582.9489 ft
68 ft
9.33 It
0
INFILTRATION
#
Scope Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000415
1994.1 109AS
205.88
.3112
7
4130/2018 9:54 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R4t15-2014
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Strip Heat
None
COP:1
36 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Spllt
SEER: 16
36 kStu/hr
1080 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 50 gal
120 deg
None
_
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft°
DUCTS
— Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1 Attic 6 366.4 ft Attic
91.6 ft' Proposed On
Main
— cfm
91.6 cfm 0.05
0.50
1 1
TEMPERATURES
Programable Thermostat; Y
Ceiling Fans:
Coolin r[ j, Jan [[ ]] Feb [[ �Mar
Heating Jan (X] Feb (Xj Mer
A r
Ma Jun [[XX]] Jul
Jun [) Jul
([X Au
L Aug
[[X Se
I Sep
j
L1
Oct
Oct
Nov
Nov
Nov
Dec
Dec
Venting [ ] Jan [ 1 Feb [Xl Mar
l J
Apr
May Jun [[ ]] Jul
[t Aug
[[ Sep
l�l
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) PM 68
68 68
68 688 68
68
68
68
68
66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
4/30/2018 9:54 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The,lower the EnergyPerformance Index, the more efficient the home.
2680 Conifer Dr. , Ft. Pierce, FL, 34951
1.. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.62
SHGC: SHGC=0.25
b. U-Factor. Dbl, U=0:51
SHGC: SHGC=0.22
c. U-Factor: Dbl, U=0.40
SHGC: SHGC=0.26
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8, Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. N/A
I certify that this home has complie
Construction through the above en
4n this home before final inspection
based on installed Code compliant
Builder Signature:
Address of New Home:
New (From Plans)
9. Wall Types_
Insulation
Area
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1
1608.20 ft2
b. Framer Steel,, Adjacent.
R=11.0
199.11 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
No
a. Under Attic (Vented)
R=30.0
1832.00 ft2
1832
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
151.00 it2
11. Ducts
R f12
a. Sup: Attic, Re(: Attic, AK Main
6 366.4
96.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
12.00 ft2
a. Central Unit
36.0 SEER:16.00
112
6.745 ft.
0.239
Insulation Area
R=0.0 1832.00 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
with the Florida Energy Efficiency Code for Building t1
gy saving features which will be installed (or exceeded)
Otherwise, a new EPL Display'Card will be completed
=P r
Date
f
City/FL Zip: J�l �/G P/-
�y�s,
kBtu/hr Efficiency
36.0 COP:1.00
Cap:50 gallons
EF: 0.95
•Notes This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge. Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified' Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code,'Energy Conservation, if not DEFAULT.
1/18/2018 3:11 PM EnergyGaugeS USA - FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
0
Buildin AnaIVSI$ Job: Grenadine Lot 50
g 7 Date: 10-31-17
Entire House By: Skyetec
For: GHO Homes
2680 Conifer Drive, Fort Pierce, FL 34951
Location:
Indoor:
Heating
Cooling
St Lucie Co Intl, FL, US
Indoor temperature (°F)
70
75
Elevation: 26 ft
Design TD (°F)
29
15
Latitude: 28°N
Relative humlddlty�(%)
50
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
24.4
56.9
Dry bulb (°F) 41
90
Infiltration:
Daily range °F) -
15 (L )
Method
Simplified
Wet bulb (°F-
�
77
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Component
Btuh/ftz
Btuh
% of load
Walls
4.0
6047
19.4
Glazing
16.5
4274
13.7
Doors
11.3
528
1.7
Ceilings
0.9
1698
5.5
Floors
3.1
5715
18.4
Infiltration
2.2
3638
11.7
Ducts
6364
20.4
Piping
0
0
Humidification
0
0
Ventilation
2868
9.2
Adjustments
0
Total
31132
100.0
Component
Btuh/ft2
Btuh
% of load
Walls
2.4
3715
15.0
Glazing
15.4
3981
16.0
Doors
11.4
533
2.1
Ceilings
1.0
1921
7.7
Floors
0
0
0
Infiltration
0.6
1017
4.1
Ducts
6123
24.7
Ventilation
1523
6.1
Internal gains
6010
24.2
Blower
0
0
Adjustments
0
Total
1
1 24823
100.0
Latent Cooling Load = 9620 Btuh
Overall U-value = 0.115 Btuh/ftz-°F
Data entries checked.
WrlghtSoft� 2017-Oct-3117:04:14
RlghtSuite® Universal 2017 17.0.04 RS000269 Page 1
..d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
Component Constructions
Entire House
For: GHO Homes
2680 Conifer Drive, Fort Pierce, FL 34951
Job: Grenadine Lot 50
Date: 10-31-17
By: Skyetec
Location:
Indoor:
Heating
Cooling
St Lucie Co Intl, FL, US
Indoor temperature (°F)
70
75
Elevation: 26 ft
Design TD (°F)
29
15
Latitude: 28°N
Relative humidity (°/a)
50
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
24.4
56.9
Dry bulb (OF) 41
90
Infiltration:
Daily range (°F) -
15 ( L )
Method
Simplified
Wet bulb (OF) -
77
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptions
Or
Area
U-value
Insul R
Htg HTM
Loss
Clg HTM
Gain
ft,
Btuh/W °F
W T/Bluh
Btuh/ft'
Btuh
Btuh/ft'
Btuh
Walls
13A-4ocs: Blk wall, stucco ext, r-4 ext bd ins, 8" thk, 1/2" gypsum
n
138
0.143
4.0
4.15
571
2.59
356
board int fnsh
a
470
0.143
4.0
4.15
1947
2.59
1215
s
248
0.143
4.0
4.15
1027
2.59
641
w
492
0.143
4.0
4.15
2041
2.59
1274
all
1347
0.143
4.0
4.15
5586
2.59
3486
Partitions
12C-Osw: Frm wall, stucco ext, r-13 cav ins, 2"x4" wood frm, 16" o.c.
stud
Windows
2glazing, clr low-e outr, argon gas, mtl no brk frm mat, cir innr, 1/4" n
gap, 1/4" thk: 2 glazing, cir low-e outr, argon gas, mtl no brk frm mat,
cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°,
medium; 50% outdoor insect screen; 3 ft overhang (6 ft window ht, 1 ft s
sep.); 6.67 ft head ht
all
2 glazing, cir low-e outr, argon gas, mtl no brk frm mat, clr innr, 1/4" e
gap, 1/4" thk: 2 glazing, cir low-e outr, argon gas, mtl no brk frm mat,
cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°,
medium; 50% outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1
ft sep.); 6.67 It head ht
2 glazing, cir low-e outr, argon gas, mtl no brk frm mat, cir innr, 1/4" e
gap, 1/4" thk: 2 glazing, clr low-e outr, argon gas, mtl no brk frm mat,
clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°,
medium; 50% outdoor insect screen; 1.5 it overhang (3 ft window ht, 1
ft sep.): 6.67 ft head ht
2 glazing, clr low-e outr, argon gas, mtl no brk frm mat, clr innr, 1/4" e
gap, 1/4" thk: 2 glazing, clr low-e outr, argon gas, mtl no brk frm mat, s
clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, w
medium; 50% outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 w
ft sep.); 6.67 ft head ht
all
175
0.091
13.0 -
2.64
461
1.31
229
24
0.620
0
18.0
432
12.2
292
18
0.620
0
18.0
324
12.2
219
42
0.620
0
18.0
755
12.2
511
12
0.400
0
11.6
139
23.2
278
6 0.620 0 18.0 108 26.2 157
20
0.620
0
18.0
360
26.7
534
30
0.620
0
18.0
539
12.2
365
20
0.620
0
18.0
360
26.7
534
15
0.620
0
18.0
270
26.7
400
85
0.620
0
18.0
1528
21.6
1833
- wri htsoft® 2017-Oct-31 17:04:14
9 RightSuite® Universal 2017 17,0.04 RS000269 Page 1
...d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
2 glazing, cir low-e outr, argon gas, mtl no brk frm mat, clr innr, 1/4" s 96 0.510 0
gap, 1/4" thk: 2 glazing, clr low-e outr, argon gas, mtl no brk frm mat,
cir innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.22); 50% blinds 45",
medium; 50% outdoor insect screen; 11 ft overhang (8 ft window ht, 1
ft sep.); 6.67 ft head ht
2 glazing, cir low-e outr, argon gas, mtl no brk frm mat, clr innr, 1/4" s 18 0.620 0
gap, 1/4" thk: 2 glazing, cir low-e outr, argon gas, mtl no brk frm mat,
clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°,
medium; 50% outdoor insect screen; 8 ft overhang (6 ft window ht, 1 ft
sep.); 6.67 ft head ht
Doors
11 DO: Door, wd sc type n 24 0.390 0
Ceilings
16D-30td:Attic ceiling, tile, slate, concrete roof mat, r-30 cell ins, 1/2"
gypsum board int fnsh
Floors
22A-cpm: Bg floor, heavy dry or light damp soil, on grade depth, carpet
fir fnsh
22A-tpm: Bg floor, heavy dry or light damp soil, on grade depth, tile fir
fnsh
n 23 0.390 0
all 47 0.390 0
1830 0.032 30.0
65 1.180 0
102 1.180 0
14.8 1420 10.2 981
18.0 324 12.2 219
11.3
271
11.4
274
11.3
256
11.4
259
11.3
528
11.4
533
0.93
1698
1.05
1921
34.2
2224
0
0
34.2
3490
0
0
wri htsoft® 2017-Oct-3117:04:14
9 RightSuite® Universal 2017 17.0.04 RS000269 Page 2
...d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
Pro ect Summa Job: Grenadine Lot 50
J � Date: 10-31-17
Entire House By: Skyetec
Project Information
For: GHO Homes
2680 Conifer Drive, Fort Pierce, FL 34951
Notes:
Design Information
Weather: St Lucie Co Intl, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 41 °F Outside db 90 °F
Inside db 70 °F Inside db 75 °F
Design TD 29 °F Design TD 15 °F
Daily range L
Relative humidity 50 %
Moisture difference 57 gr/lb
Heating Summary
Structure
24768
Btuh
Ducts
6364
Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
31132
Btuh
Infiltration
Method
Simplified
Construction quality
Average
Fireplaces
0
Heating Coolingg
Area (ftZ
1830
1830
Volume (ft')
18023
18023
Air changes/hour
0.38
0.20
Equiv. AVF (cfm)
114
60
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 AFU E
41975 Btuh
419755 BFtuh
764 cfm
0.025 cfm/Btuh
0.50 in H2O
Sensible Cooling Equipment Load Sizing
Structure 18700 Btuh
Ducts 6123 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 23681 Btuh
Latent Cooling Equipment Load Sizing
Structure
7199
Btuh
Ducts
2421
Btuh
Central vent (0 cfm)
0
Btuh
Equipment latent load
9620
Btuh
Equipment total load
33301
Btuh
Req. total capacity at 0.80 SHR
2.5
ton
Cooling Equipment Summary
Make Rheem
Trade RHEEM; RUUD
Cond RA1636AJ1
Coil RH 1T3621 MTAN
AHRI ref 7942208
Efficiency 13.0 EER,
16 SEER
Sensible cooling
28800
Btuh
Latent cooling
7200
Btuh
Total cooling
36000
Btuh
Actual air flow
1200
cfm
Air flow factor
0.048
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Z_ + wrightsoftm RightSuite® Universal 2017 17.0.04 RSUD0269
.4
..d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
2017-Oct-31 17:04:14
Page 1
Grenadine
3.0 Ton
Job M Grenadine Lot 50
Performed by Skyetec for:
GHO Homes
2680 Conifer Drive
Fort Pierce, FL 34951
Schedule
F
Exhaust Fan
R
Range Vent
D
Dryer Vent
Rheem Equipment AR17942208
AHU
3.0 Ton 16 SEER RA1636
Cond
3.0 Ton 16 SEER RMT36
Scale: 1 : 121
Page 1
Right -Suite@ Universal 2017
17.0.04 RS000269
2017-Oct-31 17:04:17
...Skytec\Grenadine Lot 50 GL N.rup
Duct System Summary
Entire House
For: GHO Homes
2680 Conifer Drive, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0.18
in H2O
0.32
in H2O
0.214 / 0.106
in H2O
0.116
in/100ft
764
cfm
Job: Grenadine Lot 50
Date: 10-31-17
By: Skyetec
Cooling
0.50 in H2O
0.18 in H2O
0.32 in H2O
0.214 / 0.106 in H2O
0.116 in/100ft
1200 cfm
275 ft
Name
Design
(Btuh)
Htg
(cfm)
Cig
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat[
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath 2
c 108
2
5
0.155
4.0
Ox 0
VIFx
13.2
125.0
st2
Bedroom 2
c 3121
83
151
0.151
7.0
Ox 0
V[Fx
16.6
125.0
st2
Den
c 2596
118
125
0.142
7.0
Ox 0
VIFx
16.3
135.0
st1
Dining
c 2892
119
140
0.130
7.0
Ox 0
VIFx
29.9
135.0
st1
Foyer
c 591
23
29
0,139
4.0
Ox0
V[Fx
19.4
135.0
st1
Great Room
c 2095
51
101
0.118
6.0
Ox 0
VIFx
32.0
150.0
st3
Great Room -A
c 2095
51
101
0.148
6.0
Ox 0
VIFx
20.4
125.0
st2
Kitchen
c 4277
60
207
0.138
8.0
Ox 0
V[Fx
20.9
135.0
st1
M Bath
c 939
34
45
0.119
4.0
Ox0
VIFx
29.9
150.0
st3
Master BR -A
c 3986
158
193
0.116
8.0
Ox 0
VIFx
34.2
150.0
st3
Utility
c 1309
25
63
0.200
4.0
Ox 0
VIFx
7.0
100.0
we
c 403
14
19
0.153
4.0
Ox 0
V[Fx
15.6
125.0
st2
wic
h 1076
26
20
0.119
4.0
Ox 0
VIFx
30.0
150.0
st3
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fp'm)
(in)
(in)
Material
Trunk
st3
Peak AVF
270
359
0.116
457
12.0
0 x 0
VinlFlx
st2
SO
Peak AVF
320
501
0.130
637
12.0
0 x 0
VinlFlx
st2
Peak AVF
419
636
0.116
456
16.0
0 x 0
VinlFlx
Bold/italic values have been manually overridden
htsoft® 2017-Oct-31 17:age 1
Wrl
9 Right -Suite® Universal 2017 17.0.04 RS000269 Page 1
d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
Name
Grill
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb12
Ox0
764
1200
90.6
0.116
859
16.0
Ox 0
VIFx
+ wrightsoft® RightSuite® Universal 2017 17.0.04 RS000269
d Calculations\Skytec\Grenadine Lot 50 GL N.rup Calc = MJ8 Front Door faces: N
2017-Oct-31 17:04:14
Page 2
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Building Permit # 1 BOL - 0S qq Owners Name QL >0 ea do 4)oo 4 Applicant: � H--D GY7"o
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+31.9 / -34.7
+/-55
MI WINDOWS
FL 17499.1
MPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 10" O/C
Mullions
37.7
+/-54
MI WINDOWS
FL 16353.3 1 FL 15353.4
IMPACT
1/4" TAPCONS W/ 1-1/4" MIN. EMBED
Fixed Glass
+33.4 / -36.3
+/- 55
MI WINDOWS
FL 15349.5
IMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED EQ. SPACING
Block Glass
Skylights
Sliding Glass Doors
+28.4 / -31.2
+/-55 .
MI WINDOWS
12080
FL-22401.3
IMPACT
3/16" TAPCONS W/ 1-1/4" MIN. EMBED @ 12" O/C
Swing Type Doors
+31.9 / -34.7
+/-50
THERMA TRU
3080
FL-7630.1
IMPACT
1/4" TAPCONS W/ 1-1/4" MIN. EMBED 14" O/C
French Doors
Garage Doors
+28.4 / -34.7
+39.2 / -43.7
WAYNE DALLTTO"N
i 9100
FL-9174 R11
N/A
(2)38 TITEN SCREWS AT EA. JAMB BRACKET W/1-1/4-WASHER 82-mr EMBED/2-V4- MIN. EDGE DISTANCE
Hurricane Protection
Z
Roof Ventilation^
v
Roofing Material
_83.4 PSF
-172PSF
EAGLE O2b
eF IRCONC.TILE
NOANO.17-0822.13
N/A
2 10d RING SHANK NAILS
Revised 07/22/2014
I have reviewed the above components or cladding and I h"droved their use ' this str cture. The products provide adequa se .y ce4o-the
wind loads and forces specified by current code provisions. }6-100
Name: ��((�� �(�/�..�G(/i-� Signature:
Design Prof: � Cert. No. Date: l�